• Title/Summary/Keyword: air sampler

Search Result 386, Processing Time 0.029 seconds

A Survey on Management Status of Personal Air Sampler in Domestic Provider for Work Environment Monitoring Service (국내 작업환경측정기관들의 개인시료 채취기 운용현황 실태 조사)

  • Kim, Ki-Youn;Cho, Man-Su;Ma, Hye-Lan;Lee, Kwang-Young;Jeong, Jee-Yeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.3
    • /
    • pp.359-364
    • /
    • 2014
  • Objectives: The principal aim of this study is to provide fundamental data for suggesting substantial management plan of personal air sampler by investigating current situation of work environment monitoring service provider. Materials and Methods: The questionnaires regarding a personal air sampler were sent by electronic mail to 150 institutions, except for 22 institutions which are out of business or closed temporarily, among total 172 domestic work environment monitoring service providers designated by Ministry of Employment and Labor based on 2013. The institutions which did not reply to the questionnaire for 30 days were required directly by phone call. Finally 97 institutions gave an answer to the questionnaire and therefore the respondence rate was 65%. Results: The normal operation rate of personal air sampler exceeded 70% in all the types (particle, gas and both combination) in terms of purchased year. Furthermore the personal air sampler purchased recently showed a trend of high operation rate compared to the personal air sampler purchased previously. The distribution patterns of personal air sampler In terms of manufacturers were Gillian>MSA>SKC for particle, Gillian>SKC>AMETEK for gas and Gillian>MSA>Casella for both combination, respectively. As a result, it was found that the personal air sampler manufactured by Gillian company was utilized the most in domestic work environment monitoring service provider regardless of types of personal air sampler. Conclusions: Based on the results obtained from this study, the normal operation rate according to types of personal air sampler was as follows: 94% for personal air sampler for collecting particle only, 93% for personal air sampler for collecting gas only and 89% for collecting both particle and gas. Overall, the numbers of personal air sampler possessed and operated normally in domestic work environment monitoring service provider were 5,458 and 5,062, which indicates the normal operation rate of personal air sampler in total aspect is 93%.

Comparative Study on the Efficiency Test Using Remodeled Bubble Generating Pump for Aquarium Fish and Established Air Sampling Pump (관상어용 기포발생기를 개조한 시료채취 장치와 기존의 시료채취기와의 성능 비교)

  • Jang, Bong-Ki;Chun, Jae-Young;Son, Bu-Soon;Lee, Jong-Wha;Park, Jong-An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.183-191
    • /
    • 2005
  • This study is designed to compare the performance of established samplers (personal air sampler and MiniVOL portable air sampler) commonly used in the air environment or work environment with that of the sampler made by remodeling the air bubble generator for aquarium fishes. Sampling method used in this study is the filter collection method for PM10 and total suspended particles (TSP), the liquid collection method for sulfur dioxide ($SO_2$) and nitrogen dioxide ($NO_2$), and the solid collection method for toluene, respectively. There is not a significant difference in the average concentration of TSP between the Gilian personal air sampler (1st, $0.316{\pm}0.095$; 2nd $0.191{\pm}0.090$; 3rd, $0.185{\pm}0.073mg/m^3$) and the remodeled sampler (1st, $0.317{\pm}0.106$, 2nd $0.201{\pm}0.050$; 3rd $0.189{\pm}0.081mg/m^3$). There are also not significant differences in the average concentration of PM10 among the Gilian personal air sampler ($0.058{\pm}0.006mg/m^3$), the remodeled sampler ($0.052{\pm}0.008mg/m^3$) and the MiniVOL portable air sampler ($0.054{\pm}0.007mg/m^3$). The average concentration of the SO2 by the established sampler and the remodeled one is $3.79{\pm}0.21ppb$ and $3.45{\pm}0.15ppb$, respectively. In addition, there are not sigmficant differences in the average concentration of the NO2 between the Gilian personal air sampler (1st, $0.325{\pm}0.068$; 2nd $0.341{\pm}0.206$; 3rd, $2.971{\pm}0.078{\mu}g/m^3$) and the remodeled sampler (1st, $0.300{\pm}0.062$; 2nd $0.332{\pm}0.144$, 3rd, $2.968{\pm}0.085{\mu}g/m^3$). There are not significant differences in the average concentration of toluene between the Gilian personal air sampler (1st, $0.499{\pm}0.072$; 2nd $0.598{\pm}0.112$; 3rd $2.284{\pm}0.077{\mu}g/m^3$) and the remodeled sampler (1st, $0.463{\pm}0.133$; 2nd $0.603{\pm}0.082$; 3rd $2.353{\pm}0.115{\mu}g/m^3$). From these results, we can conclude that the performance of the remodeled sampler is not different from that of established samplers. There is possibility that the remodeled sampler can be used as a alternative device for Gilian personal air sampler in area and personal air sampling.

Evaluation of Passive Sampler as a Useful Tool for Environmental Education (환경교육의 도구로서 간이 측정기의 활용에 관한 연구)

  • 전의찬;송민종
    • Hwankyungkyoyuk
    • /
    • v.11 no.2
    • /
    • pp.252-261
    • /
    • 1998
  • Since 1980's during which environmental pollution became serious enough to urge various types of environmental educations in many areas. But, most emphasis has been put on theoretical education. Even field education training mostly focused on water pollution. Therefore, simple air pollution monitoring system was needed for better field education in air pollution. In this study, we evaluated Passive Sampler as an useful tool for teaching air pollution in field. Students have found passive sampler very effective tool. Recent comparative study of auto-monitoring and passive sampler networks suggested a potential use of passive sampler as an useful tool for environmental education. In this study, the correlation between two sets of values appears very high judging from the regression slope of 0.92 and correlation coefficient of 0.91 However, inexpensive Passive sampler with easy-to-operate colorimeter, has not been used in environmental education partially because large scale fluctuation in time and space characteristic to air pollution has been overlooked so that the sampler has not been tested for an effective educational tool. Passive sampler certainly deserves further in depth research as an effective air monitoring system, and better attention to its usefulness to teach students and public.

  • PDF

A Low-Cost Open-Source Air Sampler for the Sorbent Tube Sampling for TD-GC/MS Analysis

  • Jang, Hwa-yong;Oh, Han Bin
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.95-102
    • /
    • 2020
  • In this study, we provide full descriptions of how to make a low-cost and completely open-source laboratory-made air sampler that will be used for sample adsorption for thermal desorption-gas chromatography mass spectrometry (TD-GC/MS) analysis. It is well known that harmful gases cause bad effects on human bodies, so it is necessary to identify the types and amounts of gases in industrial sites. One of the most commonly used methods for gas sampling is to utilize a sorbent tube using an air sampler. Commercially available air samplers are expensive, typically priced between $1,000 and $2,000, and their design often cannot be modified to fit the experiment. To address these shortcomings, we have developed a do-it-yourself (DIY) air sampler that is not only cheap enough, but also completely open-source. Furthermore, the performance of the fabricated air sampler was validated in conjunction with TD-GC/MS for the analysis of volatile compounds.

A Comparison of Nicotine Diffusive Sampler and XAD-4 Tube for Determination of Nicotine in ETS (공기 중 니코틴 포집에 있어 국산 확산포집기와 능동포집기의 비교 평가)

  • Kim, Hyo-Cher;Paik, Nam-Won;Lee, Kyung-Suk;Kim, Kyung-Ran;Kim, Won
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.485-491
    • /
    • 2006
  • It is widely known that Environmental Tobacco Smoke(ETS) is not good for health. ETS is composed of a lot of chemicals. So indicators are needed to evaluate the risk of ETS in air. One of the indicators is Nicotine. Active sampler has been used to measure nicotine concentration in air. The experiments were conducted to compare the active sampler method with diffusive sampler in exposure chamber and smoking areas, respectively. Sampling rate was 40.5 ml/min in exposure chamber. Experimental sampling rate (40.5 ml/min) was more than theoretical sampling rate (33.52 ml/min). And the higher was the concentration in air, the higher was experimental sampling rate. The average desorption, rate was 113.6%. The overall precision was 7.31 %. The overall accuracy was 18.96%, which were under NIOSH criteria. The average(GM) concentrations of nicotine by two sampling methods were $8.29{\mu}g/m^{3}$ (active sampler), $7.54{\mu}/m^{3}$ (diffusive sampler) in smoking area and smoking room. There was no regression between active sampler and diffusive sampler ($R^{2}=0.2397$). But slope, coefficient of determination was 1.017, 0.9292, respectively after removing outliers. And the slope (1.017) was close to the theoretical slope (1). In conclusion, this study indicated that diffusive sampler can be used to evaluate concentration of nicotine in air instead of active sampler.

Comparative Evaluation of Gravimetric Measurement Samplers for Fine Particles by Sampling Flow Rates and Meteorological Conditions (샘플유량과 기상조건에 따른 미세먼지 중량 측정용 기구간의 농도 비교)

  • Yang Won Ho;Kim Dae Won;Kim Jin Kuk;Yoon Chung Sik;Heo Yong;Lee Bu Yong
    • Journal of Environmental Science International
    • /
    • v.14 no.1
    • /
    • pp.91-96
    • /
    • 2005
  • Several samplers using gravimetric methods such as high-volume air sampler, MiniVol portable sampler, personal environmental monitor(PEM) and cyclone were applied to determine the concentrations of fine particles in atmospheric condition. Comparative evaluation between high-volume air sampler and Minivol portable sampler for $PM_{10}$, and between Minivol portable sampler and PEM was undertaken from June, 2003 to January 2004. Simultaneously, meteorological conditions such as wind speed, wind direction, relative humidity and temperature was measured to check the factors affecting the concentrations of fine particles. In addition, particle concen­trations by cyclone with an aerodynamic diameter of $4{\mu}m$ were measured. Correlation coefficient between high­volume air sampler and portable air sampler for $PM_{10}$ was 0.79 (p<0.001). However, the mean concentration for $PM_{10}$ by high-volume air sampler was significantly higher than that by Minivol portable sampler (p=0.018). Correlation coefficient between Minivol portable sampler and PEM for $PM_{2.5}$ as 0.74 (p<0.001), and the measured mean concentrations for $PM_{2.5}$ did not show significant difference. Difference of the measured con­centrations of fine particle might be explained by wind speed and humidity among meteorological conditions. Particle concentration differences by measurement samplers were proportional to the wind speed, but inversely proportional to the relative humidity, though it was not a significant correlation.

Comparison of PM 10 concentration between Gent Sampler and High-volume air sampler (Gent sampler와 High-volume air sampler의 분진 농도 비교연구)

  • 임종명;이현석;장미숙;이진홍
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.275-276
    • /
    • 2003
  • 산업의 발달에 따른 환경 오염물질의 증가와 오염물질의 종류가 다양화됨에 따라 대기 중의 유해원소 및 미량원소에 의한 환경오염과 그로 인한 인체건강에 대한 영향은 인간생활에 심각한 문제가 되므로 대기 중의 농도를 정확히 측정하는 것은 매우 중요한 일이다. 특히 미세 입자는 오염된 도심지역 분진수의 90∼99%에 이르는 높은 비율을 보이고 있고, 폐 깊숙이 침투하여 폐암을 비롯한 폐질환을 일으킬 수 있다. (중략)

  • PDF

Estimation of PCBs Concentrations in Ambient Air Using Pine Needles as a Passive Air Sampler (PAS) (소나무잎을 Passive Air Sampler(PAS)로 이용하여 대기 중 PCBs 농도 추정)

  • Chun, Man-Young
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.4
    • /
    • pp.360-368
    • /
    • 2012
  • Objective: This study was carried out to use pine needles as a passive air sampler (PAS) of atmospheric Polychlorinated Biphenyls (PCBs). Methods: PCB concentrations in ambient air ($C_a$, ng/$m^3$) and deposited on pine needles ($C_p$, ng/g dry) were analyzed simultaneously from June 1 to December 31. Air samples were taken using a low volume PUF active air sampler and the overall average air volume was about 900-1,000 $m^3$. Pine needles were collected at the end of August and December near the air sampler. Results: $C_a$ were higher at higher air temperature and lower chlorinated PCB congeners, but $C_p$ showed irregular distribution. The average PCB sampling rates from air to pine needles were 0.116 (0.002-0.389) $m^3$/day - g dry. Conclusions: A poor correlation was shown between $C_a$ and $C_p$. However, a good correlation was shown between the logarithm of octanol-air partitioning coefficient ($logK_{oa}$) and log ($C_p/C_a$), and the interrelation was better with longer sampling time (June to December) than shorter sampling time (June to August). The average PCB sampling rates from air to pine needles were the lowest with respect to PUF disk, XAD-2 resin and semipermeable membrane devices (SPMDs) PAS. The average ratio ($C_{a-calc}/C_{a-meas}$) of calculated ($C_{a-calc}$) and measured ($C_{a-meas}$) PCB concentration was 0.69 with a shorter sampling time and 1.24 with a longer, so $C_{a-calc}$ was close to $C_{a-meas}$. It was found that pine needles can be used as PAS of atmospheric PCBs, and are especially suitable for long-time PAS.

Air Quality Evaluation with Passive Samplers for Large Cities (Passive Sampler를 이용한 대도시의 대기질 평가)

  • Jeon, Eui-Chan;Kim, Shin-Do;Choi, Kum-Chan
    • Journal of Environmental Impact Assessment
    • /
    • v.7 no.2
    • /
    • pp.83-88
    • /
    • 1998
  • Filter badge type sampler has not been widely used to evaluate air quality over large cities in Korea while it can be successfully used for multi-point sampling and analysis. We evaluated the passive sampler as a new tool to monitor air quality over large cities. We latticed Metropolitan Seoul into $2{\times}2Km$ to give 136 points. $NO_2$ concentrations were measured at all the points in the Spring and Summer of 1997. According to the passive sampler data, natural green zones generally recorded lower $NO_2$ concentrations than major streets and traffic congestion areas. Passive samplers with abundant 136 points gave more detailed picture of $NO_2$ distribution while auto-monitoring network did not clearly provide the characteristics of local land use. Also, passive samplers gave 15% higher values than auto-monitoring network. The correlation between the two values appears very high judging from the regression slope of 0.92 and correlation coefficient of 0.91. This study clearly demonstrates the effectiveness of the passive sampler as a tool to monitor air quality over large cities.

  • PDF

Estimation of PCDD/Fs Concentrations in Ambient Air Using Pine Needles as a Passive Air Sampler (PAS) (소나무 잎을 PAS로 이용하여 대기 중 PCDD/Fs 농도 추정)

  • Chun, Man-Young
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.2
    • /
    • pp.116-125
    • /
    • 2015
  • Objective: This study was carried out to use pine needles as a passive air sampler (PAS) for atmospheric polychlorinared dibenzo-p-dioxins/furans (PCDD/Fs). Methods: PCDD/Fs concentrations in ambient air ($C_a$, $pg/m^3$) and deposited pine needles ($C_p$, pg/g dry) were analyzed simultaneously from June 1 to December 31. Air samples were taken using two low volume PUF active air samplers with an overall average air volume of approximately $1,200Sm^3$. Pine needles were collected the end of December near the air sampler. PCDD/Fs was analyzed by HRGC/HRMs. Results: A good correlation was shown ($R^2=0.6357$, p=0.0001) between $C_a$ and $C_p$, but a better correlation ($R^2=0.7372$, p<0.0001) existed between the logarithm of octanol-air partitioning coefficient ($LogK_{oa}$) and Log($C_p/C_a$). The average PCDD/Fs sampling rates from air to pine needles were 0.045($0.018-0.185m^3/day-g\;dry$). Conclusion: It was found that pine needles can be used as PAS for atmospheric PCDD/Fs, and they are especially suitable for long time PAS compared to PUF disk PAS.