• Title/Summary/Keyword: air relative humidity

Search Result 941, Processing Time 0.036 seconds

Ecological Environment and Rhizosphere Microflora in the Native Soil of Purple-Bracted Plantain Lily for Wild Vegetables (비비추 나물의 자생지 생태환경과 근권미생물상)

  • Cho, Ja-Yong;Heo, Buk-Gu;Yang, Seung-Yul
    • Korean Journal of Organic Agriculture
    • /
    • v.13 no.4
    • /
    • pp.389-400
    • /
    • 2005
  • This study was conducted to investigate into the ecological environments and the soil microflora of purple-bracted plantain lily (Hosta longipes Matsumura) for wild vgetables. Native soil textures of purple-bracted plantain lily were in the order of sandy loam (SL) > loam (L) > clay loam (CL). pH in soil was relatively acid by 4.8, electric conductivity was 0.08mS/cm, and organic matter content was 0.08g/kg. CEC was measured by $100.8cmol^{(+)}kg^{-1}$ and available phosphate was 103.4mg/kg. Contents of exchangeable cations in terms of potassium, calcium, and magnesium were measured by $0.33cmol^{(+)}kg^{-1},\;2.26cmol^{(+)}kg^{-1},\;and\;0.87cmol^{(+)}kg^{-1}$, etc. Diurnal changes in the air temperature of the natives were 15 to $20^{\circ}C$, that temperature differential was relatively little compared with that in open field by 15 to $30^{\circ}C$. Relative humidity in the natives were much more humid by 60 to 80% compared with that in open feld by 35 to 85%. Light intensity in the natives and the open field at ten o'clock were $2,300{\mu}mol/m^2/sec.\;and\;1,750{\mu}mol/m^2/sec.$ Total number of soil microorganisms were $8.4{\times}10^7\;c.f.u./g$. Mycorrhizal spore densities over $500{\mu}m,\;355{\sim}500{\mu}m,\;251{\sim}354{\mu}m,\;107{\sim}250{\mu}m\;and\;45{\sim}106{\mu}m$ were 0.8, 1.3, 2.1, 38.1, and 110.0 respectively. Mycorrhizal root infections by vesicle and hyphae were 17% and 6%. However, arbuscules in the roots were not shown.

  • PDF

A Study on Quality Improvement of Exporting Wood Products (수출용 목재 가공품의 품질개선에 관한 연구)

  • Chung, Byung-Jae;Lee, Eun-Chol;Oh, Kwang-In;Kim, Jong-Yeung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.22-24
    • /
    • 1974
  • 1. Object and importance of the research. The exports of plywood are increasing annually and it has ranked first in the world market because of the high quality product developed and manufactured using modern techniques. However, it is known that the exports of the other wood products, except plywood, is inactive because of their low quality. Accordingly, to increase the exports of various wood products investigations were carried out on kiln drying techniques to improve the quality of the wood. 2. The details and scope of the research Wet wood should be kiln dried before use to prevent various drying defects such as distortion, shrinkage etc, which would develop after processing, and also wet wood is not suitable for cutting, gluing and finishing. Therefore, the kiln drying properties of lumber from such species as Persimmon, Oak, Ramin and Meranti which are used in large quantity for manufacturing exporting wood products have been studied. Also the real state of kiln drying industry in Korea was investigated. 3. Results and proposal for practical use of the research 3. 1 Results of the research 3.1.1 The end checks and the time for drying from intial moisture content of about 40 percent to 5 percent moisture content in ovendry were investigated as Table 1. 3.1.2 The kiln dried results, for 30mm stock, which are presented by using kiln schedule Table 2 are as Table 3. 3.1.3 The kiln schedule for Persimmon which has a normal drying properties is given in Table 4. However, the persimmon which has easy checking properties should be air dried under a relative humidity of above 85% until reaching about 25 percent moisture content. 3.1.4 The kiln schedules for ramin, meranti and oak are given respectively as follows. Ramin kiln schedule ............ Table 5 and Table 6 Meranti kiln schedule ............ Table 7 Oak kiln schedule ............ Table 8 3.2 Proposal for practical use of the research Firms using the above species should be informed the results of the research so they can be used to preventing drying defects and shortening drying time.

  • PDF

Long-term Climate Change Research Facility for Trees: CO2-Enriched Open Top Chamber System (수목의 장기 기후변화 연구시설: CO2 폭로용 상부 개방형 온실)

  • Lee, Jae-Cheon;Kim, Du-Hyun;Kim, Gil-Nam;Kim, Pan-Gi;Han, Sim-Hee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.14 no.1
    • /
    • pp.19-27
    • /
    • 2012
  • The open-top chamber (OTC) system is designed for long term studies on the climate change impact on the major tree species and their community in Korea. In Korea Forest Research Institute (KFRI), the modified OTC system has been operating since September 2009. The OTC facility consists of six decagon chambers (10 meters in diameter by 7 meters high) with controlled gas concentration. In each chamber, a series of vertical vent pipes are installed to disperse carbon dioxide or normal air into the center of the chamber. The OTC is equipped with remote controlled computer system in order to maintain a stable and elevated concentration of carbon dioxide in the chamber throughout the experimental period. The experiment consisted of 4 treatments: two elevated $CO_2$ levels ($1.4{\times}$ and $1.8{\times}$ ambient $CO_2$) and two controls (inside and outdoors of the OTC). Average operational rate was the lowest (94.2%) in June 2010 but increased to 98% in July 2010 and was 100% during January to December 2011. In 2010~2011, $CO_2$ concentrations inside the OTCs reached the target programmed values, and have been maintained stable in 2011. In 2011, $CO_2$ concentrations of 106%, 100% and 94% of target values has been recorded in control OTC, $1.4{\times}$ $CO_2$-enriched OTC and $1.8{\times}$ $CO_2$-enriched OTC, respectively. With all OTC chambers, the difference between outside and inside temperatures was the highest ($1.2{\sim}2.0^{\circ}C$) at 10 am to 2 pm. Temperature difference between six OTC chambers was not detected. The relative humidity inside and outside the chambers was the same, with minor variations (0~1%). The system required the highest amount of $CO_2$ for operation in June, and consumed 11.33 and 17.04 ton in June 2010 and 2011, respectively.

Effect of Shading Methods on Growth and Fruit Quality of Paprika in Summer Season (파프리카 여름재배시 차광방법이 생육과 과실특성에 미치는 영향)

  • Ha, Jun Bong;Lim, Chae Shin;Kang, Hyo Yong;Kang, Yang Su;Hwang, Seung Jae;Mun, Hyung Su;An, Chul Geon
    • Journal of Bio-Environment Control
    • /
    • v.21 no.4
    • /
    • pp.419-427
    • /
    • 2012
  • This study was carried out to investigate the effect of two shading methods, shading agent spray on the glasshouse and internal shading screen treatment, on the growth and fruit quality of paprika (Capsicum annuum L. 'Cupra' and 'Coletti') in summer season cultivation. In the shading agent treatment, a commercial shading agent diluted with water at a ratio of 1 : 4 was sprayed on the roof of a glasshouse. In the internal shading screen treatment, a 10~20% shaded screen was used during the day time when the sun radiation was greater than $700W{\cdot}m^{-2}$. Compared to the unshaded control, photosynthetic photon flux density (PPFD) decreased in the greenhouse in the shading agent (SA) and shading screen (SS) treatments by 20% and 30%, respectively. Lower air temperatures and higher relative humidities were observed in the SA than in both the control and the SS treatment. Time to reach the break point of humidity deficit $8g{\cdot}m^{-3}$ was 2 hours late in the SA than in both the control and the SS treatment. Compared to control, both the SA and the SS treatments showed lower instantaneous temperatures of leaf, fruit, and flower by $2^{\circ}C$, $5^{\circ}C$ and $3^{\circ}C$, respectively. There were no differences in number of branches, stem diameter, and leaf size among treatments although both shading treatments promoted plant height in both cultivars. Botrytis infection ratio declined with the SA treatment by 14.7% in 'Cupra' and 22.1% in 'Coletti' as compared to that in the control. Shading increased fruit size in both cultivars, whereas no differences were observed in the number of locules and thickness of fruit tissue among treatments. Shading treatment increased mean fruit weight by a range of 10 to 15 g per fruit, while it decreased soluble solids contents as compared to that in the control. Similar Hunter values were observed among treatments, while fruit firmness increased slightly in shading treatments. Compared to the control, shading treatments improved marketable fruits by 11.7~22.6% and increased the number of fruits per plant by 4~9.2 in both 'Cupra' and 'Coletti'. The results of this study indicate that shading agent application on the roof of glasshouse would be one of the most effective options to reduce heat stress imposed on the paprika crop in summer cultivation, resulting in improved crop growth and fruit yield.

Changes in Circulatory and Respiratory Activities Observed on Men in an Engine Room of a Navy Ship (함정 기관실내 활동의 순환 및 호흡 기능에 대한 영향)

  • Hyun, Kwang-Chul;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.1 no.2
    • /
    • pp.199-213
    • /
    • 1967
  • Circulatory and respiratory activities were observed in men exposed to the environment of engine room of a cruising Republic of Korea Navy ship and compared to the control values obtained in an ordinary laboratory room on land. The environment of an engine room of cruising navy ship was presumed to be a multiple stress acting on men. The environment of the engine room included high temperature $(35-42^{\circ}C)$, low relative humidity (20-38% saturation), vibration (about 7 cycles per second), rolling and pitching of ship and noises. Sixteen men were divided into two groups consisted of each 8 subjects. Subjects of sea duty group had experience of continuous on board duty averaging 3.5 years. Men of land duty group had no experience of on board activity. On land observations were made on one day prior to the boarding and leaving the port and four days after landing. In between observations in the engine room were made on the first, 5 th, 9 th, 12 th, and 14 th day of on board activity. The whole experimental period lasted for 20 days. Measurements on circulatory and respiratory parameters were at standing resting state (after 30 minutes standing in the case of on land study and 15 minutes in engine room study) and within one minute after cessation of on the spot running of which rhythm was 30/min. and lasted for 5 minutes. Oxygen consumption and pulmonary function test were done in the period of two minutes from the 3rd to 5th minutes of running. The following results were obtained. 1. Body temperature showed no change regardless of group difference or on land or on board measurements. 2. Pulse rate increased markedly after boarding the ship id both groups. Pulse rate increased from the first day on board at rest and after exercise as compared to the on land control value. This increase in pulse rate was more marked after exercise. Sea duty group showed less increase in pulse rate at rest than the land duty group. Standing and resting pulse rate of sea duty group on lam was 81 and increased to 87 at the 5th day on board and remained smaller than the land duty group throughout the period on board. Control standing and resting pulse rate of land duty group on land was 76 and reached 89 at the 9th day on board and thereafter decreased a little. Pulse rate of land duty group at rest on board remained greater than that of sea duty group throughout the period on board. 3. Systolic blood pressure of sea duty group increased after boarding the ship and remained higher than the control value on land. In the land duty group, however, systolic blood pressure decreased during the period on board the ship. Diastolic blood pressure decreased in both groups. 4. Resting breathing rate of land duty group increased and remained higher than the control value on land. In sea duty group, however, resting breathing rate showed a transient increase on the 1st day on board and decreased thereafter to the control value on land and kept the same level throughout the period of cruise. Absolute value of breathing rate in the sea duty group was greater than the land duty group both at rest and after exercise. 5. There was a lowering of breathing efficiency in both groups. Thus, increases in tidal volume and minute ventilation volume and decreases in maximum breathing capacity, vital capacity, capacity ratio and air velocity Index were observed after boarding the ship. An increase in ventilation equivalent was also observed in both groups. The lowering of breathing efficiency was more marked in the land duty group than the sea duty group. 6. Energy expediture increased in both groups during their stay on the ship and was more marked in the sea duty group. 7, Lactate concentration in venous blood at rest and after exercise increased after boarding the ship and no group difference was observed.

  • PDF

A Study on Seasonal Variation of Water Content under Highway Asphalt Pavements Using Neutron Moisture Meter (중성자 수분측정기를 이용한 고속도로 포장의 계절별 함수량 변화 측정에 관한 연구)

  • Song Kwan-Cheol;Lee Sang-Mo;Yoo Sun-Ho;Ryu Kwan-Sik;Park Moo-Eon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.2 no.4
    • /
    • pp.156-166
    • /
    • 2000
  • This study was carried out to provide the information on seasonal variations of water content under highway asphalt pavements which influence on the dynamic behaviour and durability of pavements, and to assess the correlation between water content and soil or meteorological factors. Total eight sites for water content measurement which included fives sites in Kyungbu, two sites in Honam, and one site in Youngdong Highway were selected considering the variations in geology, topology and meteorology factors over all the country. Water contents under asphalt pavements were measured up to 170 cm depth every two week for total 13 months of August 1992 through September 1993 using neutron moisture meter(CPN-503DR). The range of water content ($\theta$$_{w}$) at the upper soils of above 50 cm depth was 7~12% and was not quite different regardless of sites, except for Iseo site. However, soil water contents below 60 or 70 cm depth were significantly different between the measurement sites, that is, the lowest water content was 5% at Kyungsan site and the highest water content was 20% at Iseo site. For all the sites, seasonal variations in water content during the experimental period were little, their range was within only 1 to 4%. Seasonal variations of water content in original or cutting area, which were 4% more or less, were slightly larger than in bedding areas, which were below 2%. Water contents under asphalt pavements had statistically significant positive correlations with silt and clay content in soil, but there were little correlations between water content and meteorological factors such as precipitation, relative humidity, mean air temperature, and wind velocity.

  • PDF

Groundwater Recharge Evaluation on Yangok-ri Area of Hongseong Using a Distributed Hydrologic Model (VELAS) (분포형 수문모형(VELAS)을 이용한 홍성 양곡리 일대 지하수 함양량 평가)

  • Ha, Kyoochul;Park, Changhui;Kim, Sunghyun;Shin, Esther;Lee, Eunhee
    • Economic and Environmental Geology
    • /
    • v.54 no.2
    • /
    • pp.161-176
    • /
    • 2021
  • In this study, one of the distributed hydrologic models, VELAS, was used to analyze the variation of hydrologic elements based on water balance analysis to evaluate the groundwater recharge in more detail than the annual time scale for the past and future. The study area is located in Yanggok-ri, Seobu-myeon, Hongseong-gun, Chungnam-do, which is very vulnerable to drought. To implement the VELAS model, spatial characteristic data such as digital elevation model (DEM), vegetation, and slope were established, and GIS data were constructed through spatial interpolation on the daily air temperature, precipitation, average wind speed, and relative humidity of the Korea Meteorological Stations. The results of the analysis showed that annual precipitation was 799.1-1750.8 mm, average 1210.7 mm, groundwater recharge of 28.8-492.9 mm, and average 196.9 mm over the past 18 years from 2001 to 2018 in the study area. Annual groundwater recharge rate compared to annual precipitation was from 3.6 to 28.2% with a very large variation and average 14.9%. By the climate change RCP 8.5 scenario, the annual precipitation from 2019 to 2100 was 572.8-1996.5 mm (average 1078.4 mm) and groundwater recharge of 26.7-432.5 mm (average precipitation 16.2%). The annual groundwater recharge rates in the future were projected from 2.8% to 45.1%, 18.2% on average. The components that make up the water balance were well correlated with precipitation, especially in the annual data rather than the daily data. However, the amount of evapotranspiration seems to be more affected by other climatic factors such as temperature. Groundwater recharge in more detailed time scale rather than annual scale is expected to provide basic data that can be used for groundwater development and management if precipitation are severely varied by time, such as droughts or floods.

Graft-taking and Growth Characteristics of Grafted Cucumber(Cucumis sativus L.) Seedlings as Affected by Light Quality and Blink Cycle of LED Modules (LED 모듈의 광질 및 점멸주기에 따른 오이접목묘의 활착 및 생장 특성)

  • Kim, Hyeong Gon;Choi, Yu Hwa;Kim, Yong Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.2
    • /
    • pp.143-149
    • /
    • 2019
  • This study was conducted to investigate the graft-taking and growth of grafted cucumber seedlings as affected by light quality and blink cycle of LED modules. Four light quality treatments, namely blue, red, blue+red, white LED and four blink cycle levels of 5s/5s, 7s/3s, 9s/1s and control were provided to investigate the effect of lighting quality and blink cycle on the graft-taking and growth of grafted cucumber seedlings. Photoperiod for the control was 12/12 h. Photosynthetic photon flux, air temperature, and relative humidity for healing were maintained at $100{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, $25^{\circ}C$, and 90%, respectively. There was no significant difference in graft-taking of grafted cucumber seedlings according to light quality except the blue LED with the blink cycle of 5s/5s. Regardless of the blink cycle, there was no significant difference in graft-taking of cucumber seedlings healed under red, blue+red, and white LED modules. These results implied that the effects of light quality and blink cycle on the graft-taking were not significant. Differences in the leaf length, leaf area, and fresh weight of cucumber seedlings healed blue or red LED with the blink cycle of 9s/1s were found to be significant. There was no significant effect of the blink cycle on the growth of cucumber seedlings healed under white LED modules. The prices of white LED are gradually falling due to increased demand. Considering the manufacturing unit price of white LED modules, the cost savings of 10-15% are expected as compared to the conventional blue/red LED modules. Therefore, it was concluded that the use of white LED modules will be economical as an artificial lighting sources for healing of grafted seedlings.

Analysis of Thermal Environment Modification Effects of Street Trees Depending on Planting Types and Street Directions in Summertime Using ENVI-Met Simulation (ENVI-Met 시뮬레이션을 통한 도로 방향별 가로수 식재 형태에 따른 여름철 열환경 개선 효과 분석)

  • Lim, Hyeonwoo;Jo, Sangman;Park, Sookuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.2
    • /
    • pp.1-22
    • /
    • 2022
  • The modification effects of street trees on outdoor thermal comfort in summertime according to tree planting types and road direction were analyzed using a computer simulation program, ENVI-met. With trees, the air temperature and wind speed decreased, and the relative humidity increased. In the case of mean radiant temperature (Tmrt) and human thermal sensation, physiological equivalent temperature (PET) and universal thermal climate index (UTCI), there was a decrease during the daytime. The greatest change among the meteorological factors by trees happened in Tmrt, and PET and UTCI showed similar patterns with Tmrt·The most effective tree planting type on thermal comfort modification was low tree height, wide tree crown, high leaf area index, and narrow planting interval (LWDN). Tmrt, PET and UTCI showed a large difference depending on shadow patterns of buildings and trees according to solar altitude and azimuth angles, and building locations. When the building shade areas increased, the thermal modification effect by trees decreased. In particular, results on the east and west sidewalks showed a large deviation over time. When applying the LWDN, the northwest, west and southwest sidewalks showed a significant reduction of 8.6-12.3℃ PET and 4.2-4.5℃ UTCI at 10:00, and the northeast, east and southeast sidewalks showed 8.1-11.8℃ PET and 4.4-5.0℃ UTCI at 16:00. On the other hand, when the least effective type (high tree height, narrow tree crown, low leaf area index, and wide planting interval) was applied, the maximum reduction was up to 1.8℃ PET and 0.9℃ UTCI on the eastern sidewalks, and up to 3.0℃ PET and 0.9℃ UTCI on the western ones. In addition, the difference in modification effects on Tmrt, PET and UTCI between the tree planting types was not significant when the tree effects were reduced by the effects of buildings. These results can be used as basic data to make the most appropriate street tree planting model for thermal comfort improvement in urban areas in summer.

Pergola's Shading Effects on the Thermal Comfort Index in the Summer Middays (여름철 낮 그늘시렁의 차양이 온열쾌적 지표에 미치는 영향)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.52-61
    • /
    • 2013
  • This study was conducted to investigate the effects of pergola's shading on the thermal comfort index in the summer. The 3 type of pergolas($4m{\times}4m{\times}h2.7m$) which were screened overhead(I)/overhead west(II)/overhead west north(III) plane with reed blind for summer shading and winter wind break, were constructed on the 4th floor rooftop. Thereafter the meteorological variables(air temperature, humidity, radiation, and wind speed) of pergola I, III and rooftop were measured from 14 to 16 August 2013(1st experiment), those of pergola I, II and rooftop were measured from 26 to 28 August 2013(2nd experiment). The effects of pergola's shading on the radiation environment and mean radiant temperature($T_{mrt}$), standard effective temperature($SET^*$) were as follows. The maximum 1 h mean values of differences ${\Delta}$ of the sums of shortwave radiant flux densities absorbed by the human body (${\Delta}K_{abs,max}$) between pergola I, III and nearby sunny rooftop were $-119W/m^2$, $-158W/m^2$, those between pergola I, II and rooftop were $-145W/m^2$, $-159W/m^2$. The maximum 1 h mean values of differences ${\Delta}$ of the sums of long wave radiant flux densities absorbed by the human body (${\Delta}L_{abs,max}$) between pergola I, III and nearby sunny rooftop, were $-15W/m^2$, $-17W/m^2$, those between pergola I, II and nearby rooftop, were $-8W/m^2$, $-7W/m^2$. The response of the direction dependent long wave radiant flux densities $L_1$ on the pergola's shading turned out to be distinctly weaker as compared to shortwave radiant flux densities $K_1$. The pergola's shading leads to a lowering of $T_{mrt}$ and $SET^*$. The peak values of $T_{mrt}$ absorbed by the human body were decreased $16^{\circ}C$ and $21.4^{\circ}C$ under pergola I and III as compared to that of nearby rooftop in the 1st experiment. Those were decreased $18.8^{\circ}C$ and $20.8^{\circ}C$ under pergola I and II as compared to that of nearby rooftop in the 2nd experiment. The peak values of $SET^*$ absorbed by the human body were decreased $2.9^{\circ}C$ and $2.6^{\circ}C$ under pergola I and III as compared to that of nearby rooftop in the 1st experiment. Those were decreased $3.5^{\circ}C$ and $2.6^{\circ}C$ under pergola I and II as compared to that of nearby rooftop in the 2nd experiment. The relative $SET^*$ decrease in pergola II, III compared to nearby sunny rooftop $SET^*$ were lower than that in pergola I, revealing the influence of the wind speed. Therefore it is essential to design pergola to maximize wind speed and minimize solar radiation to achieve comfort in the hot summer. The $SET^*$ under pergola I, III were exceeded $28.7^{\circ}C$ and $30.4^{\circ}C$ which were the upper limit of thermal comfort and tolerable zone during all most daytimes in the 1st experiment(maximum air temperature $37.5^{\circ}C$). The $SET^*$ under pergola I was exceeded $28.7^{\circ}C$ which was the upper limit of thermal comfort zone at 13h, that under pergola II was exceeded $28.7^{\circ}C$ from 8h to 14h, meanwhile the $SET^*$ under pergola I, II were within thermal tolerable zone during most daytimes in the 2nd experiment(maximum air temperature $34.4^{\circ}C$). Therefore to ensure the thermal comfort of pergola for summer hottest days, pergola should be shaded with not only reed blind but also climbing and shade plants. $T_{mrt}$ and $SET^*$ were suitable index for the evaluation of pergola's shading effects and outdoors.