• Title/Summary/Keyword: air quality evaluation

Search Result 607, Processing Time 0.034 seconds

Measurement and Evaluation of Indoor Air Quality in Small-scale apartments in Daegu (대구지역의 신축 소규모 공동주택에 있어서 실내공기질 측정 및 평가)

  • Park, Hyun-Sik;Kim, Hyun-Tae;Hong, Won-Hwa
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.217-223
    • /
    • 2019
  • The purpose of this study was to measure the indoor air quality of small-scale apartments and then proposed a method to improve the indoor air quality of the small-scale apartments by comparing with the result of indoor air quality in the Clean-Healthy House. In case of formaldehyde, a highly volatile organic compound, the concentrations of indoor measured both in small-scale apartments and the Clean Healthy houses did not exceed- the guideline of Korea. The guideline of Korea for acetaldehyde was not available, so the guidelines of Japan and the World Health Organization were used to measure the concentration of acetaldehyde. The study results demonstrated that three out of seven small-scale apartments investigated exceeded the guideline of Japan; and the preliminary research on the Clean-Health Houses was low at about 30-60% of the guideline of Japan. The result of the VOCs measurement showed that toluene, ethylbenzene, and styrene in some small-scale apartments exceeded the guideline of Korea. However, the Clean-Healthy Houses in the previous studies did not exceed the guideline of Korea with regard to all the pollutants. Therefore, this study suggests the application of the construction standards of the Clean-Healthy house in order to improve the indoor air quality of small-scale apartments. In addition, the current study anticipates that improvement of the indoor air quality in the residential environments should be universally applied, not limited to the type and size of the residence.

Changes in the Comfort and Image Quality of the Patient According to the Application of Air Mattresses in the Computed Tomography Table (전산화단층촬영 테이블의 에어 매트리스 적용에 따른 환자의 편안함과 화질 변화)

  • Young-Hee, Lee;Yong-Ki, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.889-896
    • /
    • 2022
  • This study attempted to evaluate the usefulness of the air mattress by analyzing the subjective comfort of the patient due to the application of the air mattress to the table of computed tomography through a questionnaire and analyzing the change in image quality through quantitative and qualitative evaluation of the patient's clinical images. The subjects who participated in the study were 221 men and 229 women, and the age range was from 18 to 86. To evaluate the change in image quality, a total of 150 patients, 50 patients per group, were selected for quantitative evaluation, and 20 patients per group, a total of 60 patients were selected for qualitative evaluation. As a result of this study, the subjective comfort of patients increased due to air mattresses, and there was no difference in image quality as a result of quantitative and qualitative evaluation of clinical images. From the above results, it is believed that the air mattress can be usefully applied in a way that can increase the subjective comfort of the patient without any harm to the diagnostic image.

Evaluation of the Outdoors side Air-conditioner Sound using Time Signal Analysis (Time signal 분석을 통한 에어컨 실외기의 소음 평가에 대한 연구)

  • 한형석;구형모;모진용;박득용;김주환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.330-332
    • /
    • 2003
  • In this paper, It is introduced new sound quality method, FI(Fluctuation Index) and the example applied Outdoors side Air-conditioner noise evaluation. Because FI is applied with very simple algebraic calculation algorithm, it can be applied some other application without spending high time and cost.

  • PDF

Evaluations of a Commercial CLEANBOLUS-WHITE for Clinical Application

  • Geum Bong Yu;Jung-in Kim;Jaeman Son
    • Progress in Medical Physics
    • /
    • v.35 no.1
    • /
    • pp.10-15
    • /
    • 2024
  • Purpose: This study aimed to comprehensively investigate the diverse characteristics of a novel commercial bolus, CLEANBOLUS-WHITE (CBW), to ascertain its suitability for clinical application. Methods: The evaluation of CBW encompassed both physical and biological assessments. Physical parameters such as mass density and shore hardness were measured alongside analyses of element composition. Biological evaluations included assessments for skin irritation and cytotoxicity. Dosimetric properties were examined by calculating surface dose and beam quality using a treatment planning system (TPS). Additionally, doses were measured at maximum and reference depths, and the results were compared with those obtained using a solid water phantom. The effect of air gap on dose measurement was also investigated by comparing measured doses on the RANDO phantom, under the bolus, with doses calculated from the TPS. Results: Biological evaluation confirmed that CBW is non-cytotoxic, nonirritant, and non-sensitizing. The bolus exhibited a mass density of 1.02 g/cm3 and 14 shore 00. Dosimetric evaluations revealed that using the 0.5 cm CBW resulted in less than a 1% difference compared to using the solid water phantom. Furthermore, beam quality calculations in the TPS indicated increased surface dose with the bolus. The air gap effect on dose measurement was deemed negligible, with a difference of approximately 1% between calculated and measured doses, aligning with measurement uncertainty. Conclusions: CBW demonstrates outstanding properties for clinical utilization. The dosimetric evaluation underscores a strong agreement between calculated and measured doses, validating its reliability in both planning and clinical settings.

Properties of Water-based Paint mixed with Photocatalyst for Indoor Air Quality Improvement (실내 공기질 개선을 위한 광촉매를 혼입한 수성도료의 특성)

  • Choi, Byung-Cheol;Park, Chae-Wool;Kyoung, In-Su;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.29-30
    • /
    • 2020
  • As the modern society enters, the building becomes sealed and the public's interest in the environment increases, so the interest in indoor air pollution increases and the environmental pollution is raised as an important issue not only outdoors but also indoors. In addition, the emergence of sick house syndrome (SHS) has increased the interest in formaldehyde and is a cause of deteriorating indoor air quality. Accordingly, this study prepared a functional paint by incorporating a photocatalyst in an aqueous paint, and conducted formaldehyde adsorption experiments and functional evaluation. As a result of the experiment, as the photocatalyst was added, the formaldehyde adsorption performance tended to increase. In addition, as a result of measuring the impact resistance and alkali resistance according to the KS standard, there is no difference in residual cracks and cracks between the water-based paint without the photocatalyst and the water-based paint with the photocatalyst added. Therefore, it is considered that the water-based paint added with a photocatalyst can improve the indoor air quality by adsorbing formaldehyde and can be used as a functional paint because the functionality is not different from that of a general water-based paint.

  • PDF

Impacts of Urban Green Spaces on Air Quality (도심지역 녹지의 국지적 대기환경영향에 관한 연구)

  • Joo, Hyun Soo;Kim, Seogcheol
    • Korean Chemical Engineering Research
    • /
    • v.47 no.3
    • /
    • pp.386-393
    • /
    • 2009
  • This study was to find out the quantitative relation between urban treed area(neighborhood parks) and the atmosphere environment in real condition, focusing the gas-phase non-reacting air pollutants(SOx and NOx) decreasing function of trees in urban area. It also developed a quantitative analysis method for evaluation of the atmosphere influence in the type of treed areas. We set up the Pagoda Park in Seoul and its neighbourhood as a modelling area to analyse air quality impacts by urban neighbourhood park trees. From the modelling result of the Pagoda Park case study, it is concluded that urban neighbourhood park has an important meaning to suppress construction of emission sources which drive the urban polluted air quality worse, even though park's trees have relatively small air purifying function. Especially in the urban area severely contaminated by air pollutants, the first considered air quality management policy is conservation of green spaces in neighborhood park.

Simulation and Health Risk Evaluation of Indoor Air Quality Changes by Ventilation System in New Apartment (신축아파트 환기방식에 따른 실내공기질 변화와 이에 대한 시뮬레이션 및 건강 위해성 평가)

  • Bao, Wei;Jung, Jaeyoun;Jeong, Insoo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.23 no.4
    • /
    • pp.38-45
    • /
    • 2021
  • In this study, air quality conditions were identified and analyzed in real time, at the same time, living habits and ventilation methods were maintained in the daily life of residents, and thus, this present study focuses on the lifestyles of residents. Previous studies showed a difference from this study, focusing on the study on the effects of changes in indoor air quality on human health according to the indoor air quality process test standards of the Ministry of Environment. Formaldehyde concentrations exceeded all ventilation standards, but satisfied the organic standards of the Ministry of Environment when ventilation devices and air purifiers were activated. As such, it was investigated that a large amount of formaldehyde emission in the condo is initially ventilated, but a certain concentration is maintained. The change in PM2.5 concentration according to the ventilation method showed a clear difference. As a result of simulating indoor air flow during natural ventilation, the effects of wind speed and wind direction affect the flow rate of indoor air, and indoor polluted air is stagnant even in the presence of wind and is not completely discharged. When the risk assessment results are averaged on the day of measurement, the trends of change between adults and children are almost equivalent, but the results address that children are more sensitive to risk than adults.

Long-term Trend Analysis of Key Criteria Air Pollutants over Air Quality Control Regions in South Korea using Observation Data and Air Quality Simulation (관측자료와 대기질 모사를 이용한 주요 기준성 대기오염물질의 권역별 장기변화 분석)

  • Ju, Hyeji;Kim, Hyun Cheol;Kim, Byeong-Uk;Ghim, Young Sung;Shin, Hye Jung;Kim, Soontae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.101-119
    • /
    • 2018
  • In this study, we analyzed long-term measurements and air quality simulation results of four criteria air pollutants ($PM_{10}$, $O_3$, $NO_2$, and $SO_2$) for 10 years, from 2006 to 2015, with emphasis on trends of annual variabilities. With the observation data, we conducted spatial interpolation using the Kriging method to estimate spatial distribution of pollutant concentrations. We also performed air quality simulations using the CMAQ model to consider the nonlinearity of the secondary air pollutants such as $O_3$ and the influence of long-range transport. In addition, these simulations are used to deduce the effect of long-term meteorological variations on trends of air quality changes because we fixed the emissions inventory while changing meteorological inputs. The nation-wide inter-annual variability of modeled $PM_{10}$ concentrations was $-0.11{\mu}g/m^3/yr$, while that of observed concentrations was $-0.84{\mu}g/m^3/yr$. For the Seoul Metropolitan Area, the inter-annual variability of observed $PM_{10}$ concentrations was $-1.64{\mu}g/m^3/yr$ that is two times rapid improvement compared to other regions. On the other hand, the inter-annual variability of observed $O_3$ concentrations is 0.62 ppb/yr which is larger than the simulated result of 0.13 ppb/yr. Magnitudes of differences between the modeled and observed inter-annual variabilities indicated that decreasing trend of $PM_{10}$ and increasing trend of $O_3$ are more influenced by emissions and oxidation states than meteorological conditions. We also found similar patterns in $NO_2$. However, $NO_2$ trends showed greater regional and seasonal differences than other pollutants. The analytic approach used in this study can be applicable to estimate changes in factors determining air quality such as emissions, weather, and surrounding conditions over a long term. Then analysis results can be used as important data for air quality management planning and evaluation of the chronic impact of air quality.

Evaluation of sampling and analytical method for emission experiment of pollutants in building materials using small chamber (소형챔버를 이용한 건축자재 오염물질 방출시험방법 평가)

  • Lee, Suk-Jo;Jang, Seong-Ki;Kim, Mi-Hyun;Lee, Hong-Suk;Lim, Jun-Ho;Jang, Mee;Seo, Soo-Yun
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.344-354
    • /
    • 2005
  • This study was carried out to evaluate the performance of a small chamber sampling and analytical method for the measurement of total volatile organic compounds (TVOC) and formaldehyde (HCHO) emission from building materials. While VOC was determined by the adsorbent tube sampling and sequential thermal desorption coupled with GC/MSD analysis, formaldehyde sampled with DNPH-silica cartridge was analyzed by HPLC. Wide-range performance criteria such as repeatability, desorption efficiency, emission chamber recovery test, duplicate precision, breakthrough volume and method detection limits were investigated for the evaluation of small chamber method. The overall precision of the small chamber sampling and analytical methods was estimated within 20~30% for target compounds. In conclusion, this study demonstrated that the small chamber sampling and analytical method can be reliably applied for the measurement of building materials pollutants.

Determination of Egg Freshness and Internal Quality Measurement Using Image Analysis (계란의 신선도 결정과 영상분석을 이용한 내부품질 측정)

  • Kim, Hyeon-T.;Ko, Han-J.;Kim, Ki-Y.;Kato, K.;Kita, Y.;Nishizu, T.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.3
    • /
    • pp.166-172
    • /
    • 2007
  • Egg quality indices are related with freshness, size of air chamber, loss of weight, and viscosity of the yolk and the protein. However, since the described quality parameters require measured in a destructive way, it is not suitable to inspect the egg quality with complete enumeration. Therefore, this study was performed to investigate the potential of image analysis method for evaluation of internal egg quality. Samples of 90 fresh eggs were collected immediately after laying and stored up to 24 days. Five eggs were randomly drawn from each storage condition (packing vs unpacking) at a regular interval and loss of weight, specific gravity and size of air chamber were measured. The image analysis for nondestructive measurement of size of air chamber was also studied. Results showed that the egg weight and gravity gradually decreased with increasing of storage days, while the size of air chamber linear increased caused by evaporation of water through the shell. A relationship a between conventional method and the image analysis method for measuring the size of air chamber was developed with the correlation coefficient of 0.928. The new finding implied that image analysis might provide a useful nondestructive tool to assess internal egg quality.