An Experiment on Performance Evaluation of Energy Consumption of an Exhaust Air Heat Recovery Type Air Washer for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 배기 열회수식 에어와셔의 에너지 소비량 성능평가 실험)

  • Song, Gen-Soo;Yoo, Kyung-Hoon;Shin, Dae-Kun;Son, Seung-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.844-849
    • /
    • 2008
  • In recent semiconductor manufacturing clean rooms, in order to improve clean room air quality, air washers are used to remove airborne gaseous contaminants such as $NH_3$, SOx and organic gases from outdoor air introduced into clean room. Meanwhile, there is a large quantity of exhaust air from clean room. From the energy saving point of view, heat recovery is useful for the reduction of air conditioning energy consumption for clean room. Therefore it is desirable to recover heat from the exhaust air and use it to reheat the outdoor air. However, so far there have not been sufficient studies of analyzing the comparison of the amounts of energy consumption and saving. In the present study, an experiment was conducted to investigate the energy consumption and heat recovery of a fin-coil type air washer system for semiconductor manufacturing clean rooms.

  • PDF

Evaluation of Thermal Comfort during Sleeping in Summer - Part I : On Results of Questionnaire Before and After Sleep - (여름철 수면시 온열쾌적감 평가 - 제1보 : 수면 전후 설문에 관하여 -)

  • Kim Dong-Gyu;Kum Jong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.404-409
    • /
    • 2005
  • This study is to investigate effects of thermal conditions on sleep. Five female university students participated in the sleep experiment. Three temperature levels (22, 26, and $30^{\circ}C$) were given, and relative humidity was maintained to $50\%$. When as subject arrived in the chamber at 9 o'clock in the evening, questionnaire was given to check physical and psychological conditions. After checking conditions, subjects went to bed till 07 : 30 in the morning. Body movement was checked during sleeping. After sleep in the chamber, questionnaire was given to the subject in order to check sleep quality. Subjects evaluated sleep quality by themselves by answering the time they fall asleep and wake up, frequency of wake during sleep, causes of each waking, and feeling after sleep. Sleep quality was rated with 7-point scale. At $30^{\circ}C$ condition, body movement was significantly higher than of other thermal conditions. The best sleep quality was obtained at the $26^{\circ}C$ condition, while the worst sleep was taken at the $30^{\circ}C$ condition.

Evaluation of the Effect of Traffic Control Program on the Ambient Air Quality in Seoul Metropolitan Area Using the Lower Level Stability Index of Atmosphere (하층대기의 연직 안정도 지표를 이용한 차량 2부제의 수도권 대기오염도 저감효과 분석)

  • Kim C.-H.;Park 1.-S.;Lee S.-J.;Kim J.-S.;Hong Y.-D.;Han J.-S.;Jin H.-A.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.243-257
    • /
    • 2005
  • The effects of Traffic Control Program (TCP) on the ambient urban air quality of SO$_{2}$, NO$_{2}$, O$_{3}$, and PM$_{10}$ were evaluated in Seoul metropolitan area by using the lower atmospheric vertical stability index and daily mean wind speeds. The vertical stability index; temperature lapse rate between 1000 hPa and 850 hPa geopotential height fields, were used to identify daily vertical stability index during the 2002 World Cup period where traffic amount was reportedly reduced to half the number of vehicles. The indicated air quality levels of TCP days were then compared with those of the cases observed with analogous vertical stability during the recent 3 years from 2000 to 2002. The result indicates that the effect of TCP on the primary air pollutants are found to be approximately 39$\%$, 23$\%$ and 20$\%$ lower for SO$_{2}$, NO$_{2}$ and PM$_{10}$, respectively. The secondary air pollutant; ozone, showed relatively smaller decreasing rate (13$\%$) of daily mean concentrations (even increased during the night time). The comparison of daily maximum or peak concentrations reveals that the pronounced decreasing effects of TCP on the ambient air quality for both primary and secondary air pollutants, suggesting that TCP is one of the effective strategies to control peak or higher concentrations for most urban scale air pollutants in and around the Seoul metropolitan area.

The Impact of Job Stress of the Cabin Crew on the Service Quality During COVID-19 era

  • Ri-Hyun SHIN;Ki-Woong KIM;Suk-Hoon CHUNG
    • Journal of Distribution Science
    • /
    • v.22 no.5
    • /
    • pp.117-129
    • /
    • 2024
  • Purpose: This research aims to explore the ramifications of job stress on cabin crews within the air service distribution sector, specifically examining its impact on service quality through mediating variables such as job satisfaction and engagement during the pandemic era. Research design, data and methodology: The study is based on a sample size of 312 individuals, exclusively comprising cabin crews employed in the airline industry. Methodologically, Confirmatory Factor Analysis (CFA) and Structural Equation Modeling (SEM) were employed for statistical analysis. Results: The findings reveal that both performance evaluation and job responsibility exerted a significant impact on both job satisfaction and job engagement. Furthermore, job engagement demonstrated a substantial influence on service quality. However, in contrast, factors like unstable employment and the working environment showed no significant impact on either job satisfaction or engagement. Additionally, job satisfaction did not exert a significant influence on service quality. Conclusions: These insights will offer the valuable guidance to the airline industry in preparing for unforeseen external environments that may affect the industry. As the aviation sector navigates the challenges posed by the pandemic, understanding and addressing the intricate relationships among job stress, satisfaction, engagement, and service quality will be crucial for effective industry resilience and adaptation.

The Effect of the Cabin Service Quality on Customer Loyalty and Airline Image (고객 충성도 및 항공사 이미지 형성에 기내 서비스품질이 미치는 영향)

  • Wang, Soo-Myung;Park, Hye-Yoon
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.24 no.2
    • /
    • pp.47-58
    • /
    • 2016
  • The cabin service quality expected by customers during the air travel can be the top priority to choose an airline. Customers' perception about cabin service quality evaluation are important for developing differentiated cabin service strategies of airlines, so this study aims to analyze the effect of the cabin service quality on airline image and customer loyalty. For achieving this purpose, literature study and empirical study on cabin service, customer loyalty and airline image were performed together. As a results of research, a high level of the cabin service quality provided by airlines significantly influenced positive images of airlines and customer loyalty. And customers' positive image towards airlines practically had a substantial influence on the improvement of customer loyalty. These study results would help in creating positive images of airlines and securing customer loyalty by developing differentiated and improved cabin service quality strategies of each airline in the limitless competition of the aviation service industry.

Evaluation of the Performance and the Energy Consumption Characteristics of Heat Recovery Ventilators in Apartments (공동주택 열교환기의 성능 및 에너지소비 특성 평가)

  • Kim Sang-Min;Park Byung-Yoon;Sohn Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.496-504
    • /
    • 2005
  • Heat recovery ventilators (HRV) are developed in order to satisfy both energy conservation and the improvement of indoor air quality as an alternative for current natural ventilation systems and local mechanical ventilation systems in kitchens and bathrooms. However, the performance of HRV system and the consequent effect on heating and cooling energy saving have not been sufficiently validated quantitatively in case of the application of HRVs in real residences. In this study, field measurement and computer simulation were conducted in both summer and winter period to assess the performance and validate energy conservation effect of HRVs. Under the Korea weather condition, average total heat recovery efficiency was $27\%$ in summer and $46\%$ in winter. According to the field measurement, HRV system can save the energy by $10\%$ in summer and 15$\%$ in winter. Furthermore, according to the simulation assessment, HRV system can save the energy by $17\%$ in summer and $17\%$ in winter.

Exceedance probability as a tool to evaluate the wind environment of urban areas

  • Bady, Mahmoud;Kato, Shinsuke;Ishida, Yoshihiro;Huang, Hong;Takahashi, Takeo
    • Wind and Structures
    • /
    • v.11 no.6
    • /
    • pp.455-478
    • /
    • 2008
  • The present study aims to estimate the wind ventilation performance for pedestrian level domains from the air quality point of view. Three typical models of a dense urban area were considered and numerically simulated in order to examine the effects of the geometry of such models on wind flow characteristics, which in turn affect the air quality, within the pedestrian domain of a street canyon located within this area. The calculated flow fields were employed to estimate the exceedance probabilities within the study domain using a new approach: air exchange rate within the domain. The study has been applied to nine cities in Japan: Tokyo, Osaka, Sapporo, Niigata, Fukuoka, Nagoya, Sendai, Yokohama, and Kyoto, based on their mean wind velocity data. The results demonstrated that the exceedance probability analysis of the pedestrian wind environment could be a valuable tool during the design stage of inhabited areas for the evaluation of pollutant-removal efficiency by the applied wind. Also, the calculated probabilities demonstrated substantial dependence on both the geometry of building arrays and the wind conditions of the nine cities.

Changes in Flavor Characteristics and Shelf-life of Roasted Coffee in Different Packaging Conditions during Storage (포장 조건에 따른 저장 중 커피의 향미 특성의 변화와 보존 기간)

  • Moon, Jun-Woong;Cho, Jae-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.441-447
    • /
    • 1999
  • Changes in flavor characteristics of roasted coffee in 6 package models during storage were investigated by GC/MS analysis and sensory evaluation to establish the criteria of the shelf-life of the roasted coffee in three flavor quality-'fresh', 'satisfying' and 'minimally acceptable' levels. In direct headspace method of GC/MS, 47 volatile compounds were analyzed and the light volatile compounds were reduced sharply at initial stage of storage and faster in the package with air. The correlation between % retention of 2,3-butanedione and overall aroma of roasted coffee showed good linear-relation, of which correlation coefficient (R) were from 0.999 to 0.904 depending on package models, indicating that 2,3-butanedione would be an index chemical for evaluating the freshness of roasted coffee. In sensory evaluation of 6 package models during storage, roasted whole beans (RB) and roasted and ground (RG) coffee in air-package were preserved in 'fresh quality' for $0.5{\sim}1$ week, 'satisfying quality' for $2{\sim}3$ weeks and 'minimally acceptable quality' for 12 weeks, while roasted whole beans in valve-package and roasted and ground coffees in vacuum-package, nitrogen-package and oxygen absorbent-package were preserved in 'fresh quality' for $2{\sim}4$ weeks, 'satisfying quality' for $12{\sim}24$ weeks and 'minimally acceptable quality' for 52 weeks. The oxygen absorbent-package was slightly less effective than other three methods.

  • PDF

Development of a Prototype Continuous Flow Dryer using For Infrared Ray and Heated -air for White Ginseng (열풍과 원적외선 겸용 연속식 백삼 건조기의 개발)

  • 박승제;김성민;김명호;김철수;이종호
    • Journal of Biosystems Engineering
    • /
    • v.25 no.2
    • /
    • pp.115-122
    • /
    • 2000
  • This study was performed to develop a prototype continuous flow ginseng dryer with which better product quality and lower drying energy consumption could be achieved compared with conventional ginseng dryers. A dryer having both far infrared ray (IR) and heated-air as the drying energy sources was designed and fabricated . Dryer performance was studied by examining energy efficiencies and dryer performance evaluation indices (DPEI) during the drying tests of medium-sized four year ginseng roots with IR radiating plate temperature and drying air temperature in the range of 80-12$0^{\circ}C$ and 22-5$0^{\circ}C$, respectively. The DPEI of IR /heated -air combined drying was 1/3 of that of the conventional heated-air drying when ginseng were dried to the same final moisture ratio. When ginsengs were dried for 12 hours in the prototype IR/heated-air combination dryer, a linear relationship was found to exist between final moisture ratio and ginseng temperature. As the drying progressed, drying air temperature inside the dryer was nearly constant but ginseng temperature was drastically increased during the first two hours and gradually increased thereafter until the end of drying. With the prototype Ir/heated-air combination dryer, the drying rate changed little but the energy efficiency increased proportionally when the amount of ginseng to be dried increased. Drying capacity, energy efficiency, and DPEI of the prototype IR/heated-air combination ginseng dryer were estimated to 1.500 roots, 65% and 3.800kJ/kg-water , respectively.

  • PDF

Performance Evaluation of Multidrop Chamber Ventilation System in Apartment (공동주택 적용을 위한 다분기챔버 환기 시스템의 성능평가에 관한 연구)

  • Kim, Sung Soo;Sohn, Jang yeul
    • KIEAE Journal
    • /
    • v.9 no.4
    • /
    • pp.17-22
    • /
    • 2009
  • It is common to design the duct branches where to supply the required air flow for individual room in residential apartment house. However it is difficult to adjust the air volume adequately in small air duct branches in residential ventilation system. The purpose of this study is to figure out the performance of Multidrop chamber coupling system for the residential ventilation system. The experiments were designed to simulate apartment of $84m^2$ and established multidrop chamber duct and general duct on the ceiling of the apartment. Distribution performance of air supply rate were evaluated in this experiments. As a result, distribution performance of air supply rate in the general duct is different from designed air supply rate by about 35% ~ 50% and about 10% in the multidrop chamber system. In additional the sound insulation performance of the multidrop chamber system decreased about 20% compared with general duct system. Therefore, the multidrop chamber system is considered to satisfy proper air supply rate of each room and to improve the sound insulation performance in apartment Houses.