• Title/Summary/Keyword: air mass

Search Result 2,615, Processing Time 0.034 seconds

Effect of inlet air humidity on the combustion process of the spark-ignition engine (흡입습도가 스파아크 점화기관의 연소과정에 미치는 영향)

  • 김문헌;이성열
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.5 no.2
    • /
    • pp.41-47
    • /
    • 1983
  • The analysis shows that the variation of maximum pressure of the cycle, rate of hear release, rate of mass burned, and combustion delay are influenced by the inlet air humidity in the spark-ignition engine. The quantitative combustion delay can be obtained from the rate of mass burned. Also, the variation of time loss and effective compression ratio with the change of inlet air humidity are dominated by the development of rate of heat release.

  • PDF

The Size-Oriented Particulate Mass Ratios and Their Characteristics on the Seoul Metropolitan Subway Lines

  • Lee, Eun-Sun;Lee, Tae-Jung;Park, Min-Bin;Park, Duckshin;Kim, Shin-Do;Kim, Dong-Sool
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.217-225
    • /
    • 2016
  • The purpose of the study was to initially investigate the concentration patterns of $PM_1$, $PM_{2.5}$ and $PM_{10}$ in the Seoul subway lines, and then to figure out the PM behaviors of internal and external sources inside subway tunnels. The PMs were monitored by a light scattering real-time monitor during winter (Jan. 8-26 in 2015) and summer (July 2-Aug. 7 in 2015) in tunnel air, in passenger cabin air, and in the ambient air. The daily average $PM_{10}$, $PM_{2.5}$, and $PM_1$ concentrations on these object lines were $101.3{\pm}38.4$, $81.5{\pm}30.2$, and $59.7{\pm}19.9{\mu}g/m^3$, respectively. On an average, the PM concentration was about 1.2 times higher in winter than in summer and about 1.5 times higher in underground tunnel sections than in ground sections. In this study, we also calculated extensively the average PM mass ratios for $PM_{2.5}/PM_{10}$, $PM_1/PM_{10}$, and $PM_1/PM_{2.5}$; for example, the range of $PM_{2.5}/PM_{10}$ ratio in tunnel air was 0.82-0.86 in underground tunnel air, while that was 0.48-0.68 in outdoor ground air. The ratio was much higher in tunnel air than in outdoor air and was always higher in summer than in winter in case of outdoor air. It seemed from the results that the in/out air quality as well as a proper amount of subway ventilation must be significant influence factors in terms of fine PM management and control for the tunnel air quality improvement.

Distribution of Air-Water Two-Phase Flow in a Flat Tube Heat Exchanger (평판관 열교환기 내 공기-물 2상류 분지)

  • Kim, Nae-Hyun;Park, Tae-Gyun;Han, Sung-Pil;Shin, Tae-Ryong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.9
    • /
    • pp.687-697
    • /
    • 2006
  • The air and water flow distribution are experimentally studied for a heat exchanger composed of round headers and 10 flat tubes. The effects of tube protrusion depth as well as mass flux, and quality are investigated, and the results are compared with the previous 30 channel results. The flow at the header inlet is annular. For the downward flow configuration, the water flow distribution is significantly affected by the tube protrusion depth. For flush-mounted geometry, significant portion of the water flows through frontal part of the header. As the protrusion depth increases, more water is forced to the rear part of the header. The effect of mass flux or quality is qualitatively the same as that of the protrusion depth. Increase of the mass flux or quality forces the water to rear part of the header. For the upward flow configuration, different from the downward configuration, significant portion of the water flows through the rear part of the header. The effect of the protrusion depth is the same as that of the downward flow. As the protrusion depth increases, more water is forced to the rear part of the header. However, the effect of mass flux or quality is opposite to the downward flow case. As the mass flux or quality increases, more water flows through the frontal part of the header. Compared with the previous thirty channel configuration, the present ten channel configuration yields better flow distribution. Possible explanation is provided from the flow visualization results.

Variations of Trace Gases Concentrations and Their Relationship with the Air Mass Characteristic at Gosan, Korea (제주도 고산에서의 미량기체 농도변화와 공기괴 특성과의 관계)

  • Kim, In-Ae;Li, Shan-Lan;Kim, Kyung-Ryul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.5
    • /
    • pp.584-593
    • /
    • 2008
  • The surface $O_3,\;CO,\;NO_x,\;and\;SO_2$ were measured at Gosan in Jeju Island from May 2004 to April 2005. Over this period, the mean concentrations $({\pm}s.d.)$ of each gas was 40.06 $({\pm}16.01)$ ppbv for $O_3,\;264.92({\pm}115.73)ppbv\;for\;CO,\;1.98({\pm}2.73)ppbv\;for\;SO)_2,\;and\;4.64 ({\pm}3.24) ppbv\;for\;NO_x$. The monthly variations and the diurnal variations of these gases show that the Gosan site is situated in a relatively clean region. However, there were episodic simultaneous peaks in CO and $SO_2$, especially in winter and early spring. Using cluster analysis with air mass back- ward trajectory analysis, we suggest that these episodes are due to the influence of transportation of polluted air mass from polluted regions. In the cluster, which was under the dominant influence of clean maritime air mass, low levels of $O_3,\;CO,\;and\;SO_2$ were observed. The levels of these species were elevated in the other two clusters which had the air mass influenced by polluted continental regions. In addition, ratios of the chemical species such as $CO/NO_x,\;SO_2/NO_x,\;and\;CO/SO_2$ revealed the somewhat different characteristics of emission sources influencing each cluster. The differences in concentration of trace gases among clusters with different origin and transport pathways imply that Gosan is under the effect of pollution transported from other regions.

Observation of Water Consumption in Zn-air Secondary Batteries

  • Yang, Soyoung;Kim, Ketack
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.381-386
    • /
    • 2019
  • Zn-air battery uses oxygen from the air, and hence, air holes in it are kept open for cell operation. Therefore, loss of water by evaporation through the holes is inevitable. When the water is depleted, the battery ceases to operate. There are two water consumption routes in Zn-air batteries, namely, active path (electrolysis) and passive path (evaporation and corrosion). Water loss by the active path (electrolysis) is much faster than that by the passive path during the early stage of the cycles. The mass change by the active path slows after 10 h. In contrast, the passive path is largely constant, becoming the main mass loss path after 10 h. The active path contributes to two-thirds of the electrolyte consumption in 24 h of cell operation in 4.0 M KOH. Although water is an important component for the cell, water vapor does not influence the cell operation unless the water is nearly depleted. However, high oxygen concentration favors the discharge reaction at the cathode.

Study on the Effect of Performance Factors on the Evaporator Using Liquid Desiccant Falling Flim for Dehumidification (습식건조제 이용 제습에서의 증발기 성능인자 영향 연구)

  • Park, M.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.512-520
    • /
    • 1995
  • This study investigates the simultanceous heat and mass transfer between a falling desiccant film and air in cross flow at the interface. The application of this work is the optimization of falling film evaporators for use in potential hybrid air conditioning systems. The specific geometry considered is liquid TEG films falling along the vertical cooled surfaces of a channel with air in cross flow. The equations to describe the coupled heat and mass transfer between a falling desiccant film and air in cross flow for a falling film evaporator have been presented and solved numerically. The effects of important design and operating variables on the evaporator performance predicted by the parametric numerical analysis and suggestions for performance improvements of the evaporator are presented.

  • PDF

Precise Air-Fuel Ratio Control on Transient Conditions with the PC-ECU in SI Engine (PC-ECU를 이용한 SI 기관의 비정상상태 정밀공연비 제어)

  • Yoon, S.H.
    • Journal of ILASS-Korea
    • /
    • v.5 no.3
    • /
    • pp.9-16
    • /
    • 2000
  • In a SI engine, three-way catalyst converter has the best efficiency when A/F ratio is near the stoichiometry. The feedback control using oxygen sensors in the commercial engine has limits caused by the system delays. So it is necessary to control fuel quantity in accordance with intake air amount in order to reduce exhaust emission and improve the specific fuel consumption. Precise A/F ratio control requires measurement of air amount with respect to the cylinder and injection fuel according to the air amount In this paper, we applied nonlinear fuel injection model and developed the algorithm of A/F ratio control. This algorithm includes the methods of measurement of transient air mass flowing into each cylinder, of calculation of injection pulse width for measured air mass, and the method of feedback and engine control by using lambda sensor. Also we developed control program for IBM-PC by using C++ Builder, and tested it in the commercial engine.

  • PDF

Preprocessing Miscanthus sacchariflorus with Combination System of Cone Grinder and Air Classifier

  • LEE, Hyoung-Woo;EOM, Chang-Deuk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.49 no.4
    • /
    • pp.328-335
    • /
    • 2021
  • Considerable differences exist in the characteristics of size reduction and classification because of biomass species. Miscanthus sacchariflorus (M. sacchariflorus) Goedae-Uksae 1 is not used efficiently because of the imperfections of the processing technology for this biomass. Therefore, for the best use of specific biomass, improvement in the feedstock preparation of the biomass for processing, such as pellet manufacturing, is necessary. In this study, a laboratory-scale cone grinder and air classifier were designed and combined to investigate the performance of the combination system for M. sacchariflorus. The average equivalent spherical diameter of particles showed a close relationship with air velocity for air classification. The air velocity range to classify proper particles for pelletization was determined to be 6.0-6.8 m/s. The mass ratios of the collected particles to feed mass for four lengths of chopped M. sacchariflorus were 45.1%:46.1%, 39.1%:46.6%, and 44.1%:52.8% at the first, second, and third steps in simulating the multistep combination system, respectively.

Refinement of GRACE Gravity Model Including Earth's Mean Mass Variations (지구 평균 질량 변화를 포함한 GRACE 중력 모델 보정)

  • Seo, Ki-Weon;Eom, Jooyoung;Kwon, Byung-Doo
    • Journal of the Korean earth science society
    • /
    • v.35 no.7
    • /
    • pp.537-542
    • /
    • 2014
  • The Gravity Recovery and Climate Experiment (GRACE) has observed the Earth's mass redistribution mainly caused by the variations of groundwater, ice sheet, and sea level since its launch in April 2002. The global gravity model estimated by the GRACE observation is corrected by barometric pressure, and thus represents the change of Earth mass on the Earth's surface and below Earth's surface excluding air mass. However, the total air mass varies due to the water exchange between the Earth's surface and the atmosphere. As a result, the nominal GRACE gravity model should include the Earth's gravity spectrum associated with the total air mass variations, degree 0 and order 0 coefficients of spherical harmonics ($C_{00}$). Because the water vapor content varies mainly on a seasonal time scale, a change of $C_{00}$ (${\delta}C_{00}$) is particularly important to seasonal variations of sea level, and mass balance between northern and southern hemisphere. This result implies that ${\delta}C_{00}$ coefficients should be accounted for the examination of continental scale mass change possibly associated with the climate variations.

Heat and Mass Transfer Characteristics of LiCl Aqueous Solution for a Plate Heat Exchanger Type Dehumidifier (판형 열교환기식 제습기에서 LiCl 수용액의 열 및 물질전달 특성)

  • Jeon, Dong-Soon;Lee, Hae-Seung;Kim, Seon-Chang;Kim, Young-Lyoul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.1
    • /
    • pp.16-22
    • /
    • 2012
  • Experimental investigations were carried out to examine the heat and mass transfer characteristics of LiCl aqueous solution for a plate heat exchanger type dehumidifier. Cooling dehumidification was adopted vertical type heat exchanger. Also non woven fabric is attached surface of the heat exchanger for spreadability of LiCl aqueous solution. Mass flow-rate of LiCl aqueous solution and concentration were selected as experimental conditions. Also, In this study, the effects of relative humidity of process air and velocity were investigated experimentally. As a result of heat transfer coefficient and mass transfer coefficient of were increased film reynolds number increased. heat transfer coefficient and mass transfer coefficient of LiCl aqueous solution were 0.14~0.24 kW/$m2^{\circ}C$ and $1.3{\times}10-63{\sim}6.2{\times}10-6$ m/s respectively.