• 제목/요약/키워드: air kerma

검색결과 70건 처리시간 0.028초

RALS에 장착한 Ir-192 선원의 강도측정에 대한 고찰 (Calibration of an $^{192}Ir$ Source Used for High Dose Rate RALS.)

  • 문언철
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.56-60
    • /
    • 1994
  • In the past, brachytherapy was carried out mostly with radium or radon sources. Currently. use of artificially produced radionuclially produced radionuclides such as $^{137}Cs,\;^{192}Ir,\;^{198}Au,\;and\;^{125}I$ is rapidly increasing. Although electrons are often used as an alternative to interstitial implants, brachytherapy continues to remain an important mode of therapy, either alone or combined with external beam. The National Council on Radiation Protection and Measurements(NCRP) recommends that the strength of any ${\gamma}$ emitter should be specified directly in terms of exposure rate in air at a specified distance such as 1m. The air kerma strength is defined as the product of air kerma rate in 'free space' and the square of the disrance of the calibration point from the source center along the perpendicular bisector, i. e., $S_k=K_L{\times}L^2$. Where $S_K$ is the the air kerma strength and K is the air kerma rate at a specified distance L. (usually 1m). Recommended units for all kerma strength are ${\mu}Gym^{2}h^{-1}$.

  • PDF

Fast Low Dose C-arm CT와 DSA의 선량 비교 (Dose Comparison between Fast Low Dose C-arm CT and DSA)

  • 김찬우;김재석
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.613-618
    • /
    • 2020
  • 간동맥화학색전술 중 사용되고 있는 Fast Low Dose C-arm CT의 평균선량을 DSA의 평균선량과 비교해 보고, 전체 누적선량에서 검사기법별 평균선량 분석을 통해 피폭선량을 분석해 보았다. 본원에서 환자 50명을 임의로 선정하여 Fast Low Dose C-arm CT와 DSA의 DAP 및 Air Kerma를 조사하여 비교하였으며, 4가지 검사기법(DSA, Fast Low Dose C-arm CT, Roadmap, Fluoroscopy)의 누적선량(DAP, Air Kerma)이 차지하는 비율을 분석하였다. 통계적인 비교 분석을 위해 통계프로그램 SPSS 20.0을 이용하여 대응표본 T검정, ANOVA 검증(post hoc test : Tukey)하였다. Fast Low Dose C-arm CT가 DSA에 비해 평균선량(DAP, Air Kerma)이 통계적으로 유의하게 낮았다.(p<.001) 간동맥화학색전술에서 항암제 주입 전후로 Fast Low Dose C-arm CT를 적극 활용하여 DSA의 검사 횟수를 줄인다면 환자의 의료방사선 피폭을 감소시킬 수 있다.

Airborne HPGe spectrometer for monitoring of air dose rates and surface activities

  • Marcel Ohera;Lubomir Gryc;Irena Cespirova;Jan Helebrant;Lukas Skala
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4039-4047
    • /
    • 2023
  • This contribution describes the application of HPGe detector for the airborne quantitative analysis. The hardware of the airborne HPGe system was designed from the commercial components with only exception of the newly designed AirHPGeSpec special software to control, measure and process the data. The system was calibrated for the local air kerma rates measured on helicopter board and its conversion to the air kerma rates at 1 m above the ground was proposed. Two examples of the air kerma rates measured over the former uranium mining areas are presented and compared with the results of other airborne system on the board. This airborne HPGe system could be also used for measuring the surface activities in a radiation event. The nuclides of 131I, 132Te - 132I, 133I, 134I, 135I, 137Cs, 134Cs, 88Rb and 103Ru were selected from possible nuclear power plant emergency scenarios. The Monte Carlo simulation was used to calculate HPGe detector efficiencies for the flight altitudes from 25 to 300 m for the energies from 300 keV to 3 MeV of the nuclides in question. Also, the detection limits according to the Currie method as well as ISO 11929-2010 for selected nuclides are presented.

Ir-192 고선량률 선원에 대한 공기커마강도의 품질보증 (Quality Assurance of Air Kerma Strength for Ir-192 High Dose Rate Source)

  • 김종언;윤천실;김성현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권2호
    • /
    • pp.147-151
    • /
    • 2007
  • AAPM TG43 프로토콜에서 선원 강도의 측정은 공기커마강도로 권고하고 있다. 본 연구는 제조사에서 제공되는 공기커마강도의 정확성이 ${\pm}5%$ 범위 이내에 있는지 측정으로 검증하는데 목적이 있다. Standard imaging사의 MAX-4001 Electrometer와 HDR 1000 Plus, 그리고 6 french bronchial Applicator를 재료로 사용하여, 이온함의 중심축의 바닥으로부터 10 mm 지점에서 90 mm 지점까지 이온화 전류를 측정하였다. 측정된 이온화 전류 곡선에서 최대 이온화 전류를 나타내는 거리를 교정의 기준점으로 정하고, 이 이온화 전류 측정치로부터 공기커마강도를 구하였다. 이온화 전류 곡선의 정점인 최대 이온화 전류에 대응하는 거리는 50 mm이었다. 이 거리는 UW-ADCL의 교정 검증서의 선원의 기준점과 완전히 일치하였다. 측정으로 계산된 공기커마강도는 제조사에서 제공된 교정치보다 약 0.5% 더 높게 측정되었다. 제조사에서 제공되는 교정 검증서의 공기커마강도는 신뢰할 수 있는 정확성을 가졌다는 결과를 얻었다. 측정에서 우물형 이온함 안의 dead space의 길이와 선원의 dwell position으로 이동 오차 그리고 산란선의 영향 등을 고려하면, 정확한 측정과 교정의 결과를 얻을 수 있다고 생각된다.

  • PDF

진단용 DR 발생장치에서 IEC 표준규격과 상용부하의 공기커마 직선성에 대한 일관성 비교 (Consistent Comparison for The Linearity Air Kerma of IEC Standards and Commercial Load in Diagnosing DR Generators)

  • 한범희;김종일;이상호;한상현;유인규
    • 한국방사선학회논문지
    • /
    • 제6권5호
    • /
    • pp.389-394
    • /
    • 2012
  • 본 연구에서는 IEC 60601-2-54에서 제시한 표준을 근거로 부하조건에서의 제한된 간격으로 걸친 공기커마를 절대측정하여 X선의 직선성을 면밀히 평가하여 다음과 같은 결과를 얻었다. 10대를 대상으로 한 모든 진단용 X선 발생장치(DR)는 IEC 60601-2-54 표준에서 제시한 공기커마의 직선성이 부적합으로 나타났고, 일반적인 조사선량의 직선성 평가방법에서는 4대에서 최고 관전압의 50%와 80%의 두 개 측정 계열 모두 부적합으로 나타났으며, 나머지 6대에서는 최고 관전압의 50%와 80%의 두 개 측정 계열 모두에서 적합으로 나타났다. IEC 60601-2-54 표준에서 제시한 직선성 시험과 기존의 조사선량 직선성 시험이 많은 차이를 보였다. IEC 60601-2-54 표준+에서 제시한 공기커마의 직선성은 국제표준의 권고사항이므로 기존의 조사선량 직선성 보다 상당히 타당성이 있고, 방사선량을 정량화하기 위한 표준으로 IEC 60601-2-54 표준에서 제시한 공기커마의 직선성이 진단용 X선 영상장치 성능관리에 중요한 평가 요소라 사료된다.

MCNP 시뮬레이션을 통한 450 kVp 엑스레이 튜브의 콘크리트 차폐벽 두께 계산 및 반가층 방법을 이용한 계산과의 결과 비교 (Calculation of Concrete Shielding Wall Thickness for 450 kVp X-ray Tube with MCNP Simulation and Result Comparison with Half Value Layer Method Calculation)

  • 이상헌;허삼석;이은중;김찬규;조규성
    • 방사선산업학회지
    • /
    • 제10권1호
    • /
    • pp.29-35
    • /
    • 2016
  • Radiation generating devices must be properly shielded for their safe application. Although institutes such as US National Bureau of Standards and National Council on Radiation Protection and Measurements (NCRP) have provided guidelines for shielding X-ray tube of various purposes, industry people tend to rely on 'Half Value Layer (HVL) method' which requires relatively simple calculation compared to the case of those guidelines. The method is based on the fact that the intensity, dose, and air kerma of narrow beam incident on shielding wall decreases by about half as the beam penetrates the HVL thickness of the wall. One can adjust shielding wall thickness to satisfy outside wall dose or air kerma requirements with this calculation. However, this may not always be the case because 1) The strict definition of HVL deals with only Intensity, 2) The situation is different when the beam is not 'narrow'; the beam quality inside the wall is distorted and related changes on outside wall dose or air kerma such as buildup effect occurs. Therefore, sometimes more careful research should be done in order to verify the effect of shielding specific radiation generating device. High energy X-ray tubes which is operated at the voltage above 400 kV that are used for 'heavy' nondestructive inspection is an example. People have less experience in running and shielding such device than in the case of widely-used low energy X-ray tubes operated at the voltage below 300 kV. In this study, Air Kerma value per week, outside concrete shielding wall of various thickness surrounding 450 kVp X-ray tube were calculated using MCNP simulation with the aid of Geometry Splitting method which is a famous Variance Reduction technique. The comparison between simulated result, HVL method result, and NCRP Report 147 safety goal $0.02mGy\;wk^{-1}$ on Air Kerma for the place where the public are free to pass showed that concrete wall of thickness 80 cm is needed to achieve the safety goal. Essentially same result was obtained from the application of HVL method except that it suggest the need of additional 5 cm concrete wall thickness. Therefore, employing the result from HVL method calculation as an conservative upper limit of concrete shielding wall thickness was found to be useful; It would be easy, economic, and reasonable way to set shielding wall thickness.

방사선촬영에서 면적선량 및 새로운 실질면적선량 개념의 비교 평가 (Comparative Evaluation of Kerma Area Product and New Fundamental of Kerma Area Product on Radiography)

  • 최우철;김용민;김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.53-58
    • /
    • 2021
  • Kerma Area Product (KAP) is best indicator of radiation monitoring on radiographic examinations. KAP can be measured differently depending on the X-ray irradiation area, air kerma, souce-skin distance, type of equipment, etc. The major factors are exposure area and the air krema. The KAP currently used only considers the exposure area with X-rays and has a problem that KAP is always excessively overestimated from the dose received by an actual subject. Therefore, in this study, in order to measure the accurate KAP, a new area dose calculation that can be calculated by dividing the area where the actual X-ray is irradiated is presented, and the KAP is the real area. We compared and analyzed how much it was overestimated compared to the dose. The Skull AP projection and seven other projection were compared and analyzed, and the KAP was overestimated in each test by 52% to 60%. In this way, the effective KAP (EKAP) calculation developed through this study should be utilized to prevent extra calculation of the existing KAP, and only the accurate patient subject area should be calculated to derive the accurate area dose value. EKAP is helpful for control the patient's exposure dose more finely, and it is useful for the quality control of medical radiation exposure.

Experimental Measurement and Monte Carlo Simulation the Correction Factor for the Medium-Energy X-ray Free-air Ionization Chamber

  • Yu, Jili;Wu, Jinjie;Liao, Zhenyu;Zhou, Zhenjie
    • Journal of the Korean Physical Society
    • /
    • 제73권10호
    • /
    • pp.1466-1472
    • /
    • 2018
  • A key comparison has been made between the air-kerma standards of the National Institute of Metrology (NIM), China, and other Asia Pacific Metrology Programme (APMP) members in the medium-energy X-ray. This paper reviews the primary standard Free-air ionization chamber correction factor experimental method and Monte Carlo simulation method in the NIM. The experimental method and the Monte Carlo simulation method are adopted to obtain the correction factor for the medium-energy X-ray primary standard free-air ionization chamber at 100 kV, 135 kV, 180 kV, 250 kV four CCRI reference qualities. The correction factor has already been submitted to the APMP as key comparison data and the results are in good agreement with those obtained in previous studies. This study shows that the experimental method and the EGSnrc simulation method are usually used in the measurement of the correction factor. In particular, the application of the simulation methods is more common.

원통형 전리함을 이용한 Ir-192 선원에 대한 공기커마세기 측정 시 선질보정에 관한 연구 (Quality Correction for Ir-192 Gamma Rays in Air Kerma Strength Dosimetry Using Cylindrical Ionization Chambers)

  • 정동혁;김진기;김기환;오영기;김수곤;이강규;문성록
    • 한국의학물리학회지:의학물리
    • /
    • 제20권1호
    • /
    • pp.30-36
    • /
    • 2009
  • Co-60 선원에 대해 교정된 원통형 전리함 이용하여 Ir-192 선원에 대한 공기커마세기를 측정하는 경우에 선질 차이에 대한 보정이 필요하다. 본 연구에서는 측정학적 방법을 적용하여 PTW-N30001과 N23333 전리함에 대하여 Ir-192 감마선에 대한 선질 인자를 결정하였다. Ir-192 선원(microSelectron)의 에너지스펙트럼을 적용할 경우에 선질인자($k_u$)는 두 전리함에 대해 각각 $k_u$=1.016 (N30001)과 $k_u$=1.017 (N23333)으로 계산되었다. 치료용 microSelectron 선원에 대해 선질 인자를 적용하여 공기커마 세기를 측정하였으며 결과를 기준값과 비교하였다. 결과적으로 선질인자를 적용하는 경우에 기준 공기커마율과 약 -0.5% 이내의 차이를 보였으며 적용하지 않는 경우에는 약 -2.0%의 차이를 보였다.

  • PDF

교정용 단일에너지 형광 X-선장의 제작 (Establishment of the Monoenergetic Fluorescent X-ray Radiation Fields)

  • 김장렬;김봉환;장시영;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제23권1호
    • /
    • pp.33-47
    • /
    • 1998
  • 한국원자력연구소 교정시설에 설치되어 있는 MG325 X-선 발생장치와 ISO-4037에서 제시하고 있는 라디에이티 및 필터 8종을 조합하여 8.6 keV 부터 75 keV 까지의 단일에너지 형광 X-선을 제작하였다. 1차 X-선에 의하여 라디에이터에서 발생된 형광 X-선중 $K_{\beta}$를 필터를 사용하여 제거한 후 단지 $K_{\alpha}$만의 형광 X-선 스펙트럼을 고순도 평판형 반도체검출기와 휴대용 다중파고분석기로 분석하였으며 35 cc 전리함을 이용하여 이때의 선량률 (air kerma rates)를 측정하여 계산결과와 비교하였다. 또한 방사선장의 균일도분포를 전리함과 사진현상을 통하여 결정하였으며 산란 X-선의 영향도 측정하여 실제 적용가능성을 검토하였다. 실험결과 순도가 90 % 이상되는 8.6 keV부터 75 keV까지의 단일에너지 형광 X-선을 얻었으며 라디에이터 중심으로부터 43 cm 위치에서의 선량률은 1.91 mGy/h (라디에이터 : Au, 필터 : W)로부터 54.2mGy(라디에이터 : Mo, 필터 : Zr) 까지였다. 선량률 측정지점에서 방사선장의 유효면적은 12 cm ${\times}$ 12 cm로 계측기의 교정이나 개인선량계의 조사에 전혀 문제가 없음을 확인하였고 산란방사선의 영향도 3% 이하였다.

  • PDF