Evaluation of Drought Indices using the Drought Records (관측 자료를 이용한 가뭄지수의 평가)

  • Kim, Gwang-Seob;Lee, Jun-Won
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.8
    • /
    • pp.639-652
    • /
    • 2011
  • In this study, the suitability of drought indices was analyzed using the quantified drought records from official reports, newspapers and drought indices estimated using precipitation and air temperature data of 69 weather stations from 1973 to 2009. Test statistics of the suitability of meteorological drought indices were evaluated using the ROC analysis. Results demonstrated that PN shows the best relationships with drought records. SPI3 and Deciles Distribution Ratio also show good relationships with drought records and their variability according to the administrative divisions is relatively small. Results of the analysis of the spatial and temporal variability of drought and the accuracy of the drought indices can be used to evaluate the accuracy of drought indices in drought monitoring and prediction, and to select the best index in drought management.

A Basic Study on Physical Method for Preventing Recombination of Gas Product from the Decomposition of Ammonium Carbamate (암모니움 카바메이트 분해 시 생성된 가스의 재결합 방지를 위한 물리적 방법의 기초연구)

  • Chun, Minwoo;Yoon, Cheon Seog;Kim, Hongsuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.10
    • /
    • pp.639-647
    • /
    • 2017
  • This basic study is focused on the physically removal method of carbon dioxide from the decomposition of ammonium carbarmate to prevent the recombination of ammonium salts. A basic visual experimental set-up was designed and constructed to observe the recombination phenomena from the proper composition of ammonia gas, carbon dioxide gas, and compressed air dilution gas. To quantify the recombination phenomena, a simple device was designed to measure the weight change under severe cases for three different tube sizes. The temperature and pressure in the visual tube and the volumetric flow rates of the nitrogen dilution gas were studied and the conditions to avoid recombination were analyzed according to mean free path theory. Diffusivity values based on the Chapman-Enskog theory were calculated from the experimental data. These value may serve as an index for the prevention of recombination.

Measurements of 50 Non-polar Organic Compounds Including Polycyclic Aromatic Hydrocarbons, n-Alkanes and Phthalate Esters in Fine Particulate Matter (PM2.5) in an Industrial Area of Chiba Prefecture, Japan

  • Ichikawa, Yujiro;Watanabe, Takehisa;Horimoto, Yasuhide;Ishii, Katsumi;Naito, Suekazu
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.274-288
    • /
    • 2018
  • Quantitative data of 50 non-polar organic compounds constituting $PM_{2.5}$ were continuously collected and analyzed from June 2016 to October 2017 (approximately 17 months) at Ichihara, one of the largest industrial areas in Japan. Target non-polar organic compounds including 21 species of polycyclic aromatic hydrocarbons (PAHs), 24 species of n-alkanes and 5 species of phthalate esters(PAEs) were simultaneously measured by gas chromatography/mass spectrometry. Basically, the average concentrations of the total PAHs, n-alkanes and PAEs in each season remained nearly level, and seasonal variations were little throughout the study period. These results suggest that the emission sources, which are not influenced by the seasons, are the dominant inputs for the target organic compounds. Diagnostic ratios of PAHs, assessment of n-alkane homologue distributions, carbon preference index, and the contribution of wax n-alkanes from plants were used to estimate source apportionments. These results indicate that anthropogenic sources were the main contributor for most PAHs and n-alkanes throughout the study period. The concentrations of PAEs selected in this study were low because emission amounts of these chemicals were little within the source areas of the sampling site. To our knowledge, this study is the first attempt to simultaneously measure a high number of non-polar organic compounds in $PM_{2.5}$ collected from the ambient air of Japan, and the resultant data will provide valuable data and information for environmental researchers.

A Study on the Preparation and Growth Mechanism of Titanium Dioxide using Organic-Inorganic Hybrid Titanium Complex (유무기 하이브리드 티타늄 착화합물을 이용한 티타니아의 제조 방법 및 성장 거동에 대한 연구)

  • Kang, Yubin;Choi, Jin-Ju;Kwon, Nam Hun;Kim, Dae-Guen;Lee, Kun-Jae
    • Journal of Powder Materials
    • /
    • v.26 no.6
    • /
    • pp.487-492
    • /
    • 2019
  • Titanium dioxide (TiO2) is a typical inorganic material that has an excellent photocatalytic property and a high refractive index. It is used in water/air purifiers, solar cells, white pigments, refractory materials, semiconductors, etc.; its demand is continuously increasing. In this study, anatase and rutile phase titanium dioxide is prepared using hydroxyl and carboxyl; the titanium complex and its mechanism are investigated. As a result of analyzing the phase transition characteristics by a heat treatment temperature using a titanium complex having a hydroxyl group and a carboxyl group, it is confirmed that the material properties were different from each other and that the anatase and rutile phase contents can be controlled. The titanium complexes prepared in this study show different characteristics from the titania-formation temperatures of the known anatase and rutile phases. It is inferred that this is due to the change of electrostatic adsorption behavior due to the complexing function of the oxygen sharing point, which crystals of the TiO6 structure share.

Effect of Greenhouse Cooling and Transplant Quality Using Geothermal Heat Pump System (지열-열펌프 시스템의 온실냉방 및 육묘 효과)

  • Lee, Jae-Han;Lee, Yong-Beom;Kwon, Joon-Kook;Kang, Nam-Jun;Kim, Hak-Joo;Choi, Young-Hah;Park, Jin-Myeon;Rhee, Han-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.15 no.3
    • /
    • pp.211-216
    • /
    • 2006
  • This study was carried out to investigate the effect of greenhouse cooling by a geothermal heat pump system on greenhouse temperature and growth of vegetable transplants in summer season. Greenhouse air temperature in day time was $3-4^{\circ}C$ lower in fog plus shading system than in shading, while in night time that was $5-7^{\circ}C$ lower in geothermal heat pump (GHP) plus shading system compared to shading or fogplus shading. system. Plant height of cucumber, tomato and hot pepper transplants was shortened in GHP plus shading compared to shading or fog plus shading system. And Leaf area and dry weight were slightly decreased in GHP plus shading compared to the other systems. Therefore, healthy transplant index on cucumber, tomato and hot pepper was higher in GHP plusshading than in shading or fogplusshading system.

Study on the response surface optimization of online upgrading of bio-oil with MCM-41 and catalyst durability analysis

  • Liu, Sha;Cai, Yi-xi;Fan, Yong-sheng;Li, Xiao-hua;Wang, Jia-jun
    • Environmental Engineering Research
    • /
    • v.22 no.1
    • /
    • pp.19-30
    • /
    • 2017
  • Direct catalysis of vapors from vacuum pyrolysis of biomass was performed on MCM-41 to investigate the effects of operating parameters including catalyzing temperature, catalyzing bed height and system pressure on the organic yields. Optimization of organic phase yield was further conducted by employing response surface methodology. The statistical analysis showed that operating parameters have significant effects on the organic phase yield. The organic phase yield first increases and then decreases as catalyzing temperature and catalyzing bed height increase, and decreases as system pressure increases. The optimal conditions for the maximum organic phase yield were obtained at catalyzing temperature of $502.7^{\circ}C$, catalyzing bed height of 2.74 cm and system pressure of 6.83 kPa, the organic phase yield amounts to 15.84% which is quite close to the predicted value 16.19%. The H/C, O/C molar ratios (dry basis), density, pH value, kinematic viscosity and high heat value of the organic phase obtained at optimal conditions were 1.287, 0.174, $0.98g/cm^3$, 5.12, $5.87mm^2/s$ and 33.08 MJ/kg, respectively. Organic product compositions were examined using gas chromatography/mass spectrometry and the analysis showed that the content of oxygenated aromatics in organic phase had decreased and hydrocarbons had increased, and the hydrocarbons in organic phase were mainly aliphatic hydrocarbons. Besides, thermo-gravimetric analysis of the MCM-41 zeolite was conducted within air atmosphere and the results showed that when the catalyst continuously works over 100 min, the index of physicochemical properties of bio-oil decreases gradually from 1.15 to 0.45, suggesting that the refined bio-oil significantly deteriorates. Meanwhile, the coke deposition of catalyst increases from 4.97% to 14.81%, which suggests that the catalytic activity significantly decreases till the catalyst completely looses its activity.

An Analysis about Building-related Health Symptoms of Workers at Dental College Hospitals in Seoul (치과대학병원 종사자의 실내자각증상 관련요인 분석 -서울시내 소재 치과대학병원을 중심으로-)

  • Cho, Sung-Yeon;Yang, Ji-Yeon;Lim, Young-Yuk;Shin, Kyoung-Hee;Shin, Dong-Chun
    • Environmental Analysis Health and Toxicology
    • /
    • v.24 no.2
    • /
    • pp.149-157
    • /
    • 2009
  • In this study, recognized building-related health symptoms of various workers in dental college hospitals are surveyed and analyzed in order to improve indoor environment at dental college hospitals. We conducted a questionnaire survey for 682 workers in three dental college hospitals located in Seoul from Sep. 20 to Oct. 8, 2004. Most workers at dental hospitals complained about noise, poor ventilation, dusty environment, and air dryness. SBS symptoms score for subjects was 1.43${\pm}$0.74 (often feel) and major symptoms was throat, CNS, eye, and nose symptoms. Recognized Building-related health symptoms are significantly related to tasks, working experience, job-satisfaction, indoor environment recognition index, medical history, used to special material, and number of dental unit chair. Also working places and ventilation are significantly related to the symptom. Based on the results, it can be said that special dental treatment causes undesirable environment such as noise, dust, and bad odor. It is also related to recognized building related health symptoms reported by workers at dental hospitals. So managemental efforts are needed to improve indoor environment which is related by dental treatment.

Cardiac Response to Head-Out Water Immersion in Man

  • Choi, Jang-Kyu;Park, Won-Kun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.4 no.3
    • /
    • pp.253-261
    • /
    • 2000
  • Head-out water immersion induces marked increase in the cardiac stroke volume. The present study was undertaken to characterize the stroke volume change by analyzing the aortic blood flow and left ventricular systolic time intervals. Ten men rested on a siting position in the air and in the water at $34.5^{circ}C$ for 30 min each. Their stroke volume, heart rate, ventricular systolic time intervals, and aortic blood flow indices were assessed by impedance cardiography. During immersion, the stroke volume increased 56%, with a slight (4%) decrease in heart rate, thus cardiac output increased ${\sim}50%.$ The slight increase in R-R interval was due to an equivalent increase in the systolic and diastolic time intervals. The ventricular ejection time was 20% increased, and this was mainly due to a decrease in pre-ejection period (28%). The mean arterial pressure increased 5 mmHg, indicating that the cardiac afterload was slightly elevated by immersion. The left ventricular end-diastolic volume index increased 24%, indicating that the cardiac preload was markedly elevated during immersion. The mean velocity and the indices of peak velocity and peak acceleration of aortic blood flow were all increased by ${\sim}30%,$ indicating that the left ventricular contractile force was enhanced by immersion. These results suggest that the increase in stroke volume during immersion is characterized by an increase in ventricular ejection time and aortic blood flow velocity, which may be primarily attributed to the increased cardiac preload and the muscle length-dependent increase in myocardial contractile force.

  • PDF

Estimation of Areal Evapotranspiration Using NDVI and Temperature Data (NDVI와 기온자료를 이용한 광역증발산량의 추정)

  • Shin, Sha-Chul;An, Tae-Young
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.7 no.3
    • /
    • pp.79-89
    • /
    • 2004
  • Remote sensing technique is a probable means to estimate distribution of actual evapotranspiration in connection with regional characteristics of vegetation and landuse. The factors controlling evapotranspiration from ground surface are air temperature, humidity, wind, radiation, soil moisture and so on. Not only the vegetation influences directly the evapotranspiration, but also these factors strongly influences the vegetation growth at the area. Therefore, it can be expected that evapotranspiration is highly correlated to vegetation condition. The normalized difference vegetation index (NDVI) showed excellent ability to get the vegetation information. The NDVI is obtained using NOAA/AVHRR have been studied as a tool for vegetation monitoring. In this paper, a simple method to estimate actual avapotranspiration is proposed based on vegetation and meteorological data.

  • PDF

Features of Korean Rainfall Variability by Western Pacific Teleconnection Pattern (서태평양 원격패턴에 따른 한국 4월 강수량의 변동 특성)

  • Choi, Jae-Won;Park, Ki-Jun;Lee, Kyungmi;Kim, Jeoung-Yun;Kim, Baek-Jo
    • Journal of Environmental Science International
    • /
    • v.24 no.7
    • /
    • pp.893-905
    • /
    • 2015
  • This study analyzes the correlation between Western Pacific (WP) teleconnection pattern index (WPI) in April during 1954-2008 and rainfall amounts in the same month. Based on the results, it is identified that there have been strong positive correlations between central China, Korea and the southwestern part of Japan in the East Asian region. Through differences between 10 positive WP years and 10 negative WP years selected from the April WPI excluding ENSO years, it is found that rainfall amounts increase in April of positive WP years due to the following characteristics. Increases in rainfall amounts are evident in the East Asian middle latitudinal region where the positive correlation between the two variables is the highest and this is because anomalous southwesterlies are strengthened in the East Asian middle latitudinal region due to the spatial pattern of a south-low-north-high anomalous pressure system centered on this region that is made by anomalous anticyclones centered on the southeastern side of the region and other anomalous anticyclones centered on the northeastern side of the region. In addition, anomalous westerlies (jet) are strengthen in the upper troposphere of the East Asian middle latitudinal region and as a result, anomalous upward flows are strengthened in this region and thus anomalous warm air temperatures are formed in the entire level of the troposphere in the region. In addition to atmospheric environments, anomalous warm sea surface temperatures are formed in the seas in the East Asian middle latitudinal region to help the rainfall amount increases in the East Asian middle latitudinal region.