• Title/Summary/Keyword: air index

Search Result 1,088, Processing Time 0.028 seconds

A review on the effect of a floor heating system on the human body (기존문헌조사에 의한 바닥난방의 인체영향에 관한 연구)

  • 최영식
    • Journal of the Korean housing association
    • /
    • v.3 no.1
    • /
    • pp.85-92
    • /
    • 1992
  • A floor system have played a major part in the living in Korean house. It is an essential element in the residential houses. Uufortunately, a design method of the floor heating system for the human thereat comfort has not established in Korea system. This paper aims to review the previous researches to find the issue for the futher study of comfort floor heating design. The following results were obtained: 1) Nevins et at conducted experiments on the effect of the comfortable of floor and air temperatures on the psychological responses by a large number of subjects. Its objective was to find the combined condition to obtain thermal comfort for sedentary posture.7here has never been researches regarding a sitting Person on the heated floor. 2) Some investigation in Japan on the effect of floor heating system on a sitting person on the floor have been conducted for these years, but they are net based on the human heat balance but on only psychological responses. 3) Hirayama et al developed an indication method of the effect of heat conduction on the sedentary person.4) There are few researches on the human thermal comfort compared whth indoor environmental researches on mechanical controls in Korea. Thus, the further study on the followings in needed the estimaiing of heat conduction between tile hunman body and a floor, developing an index expressed the combined effect of convection, radiation and conduction and its associated experiments.

  • PDF

Life Cycle Assessment for the Business Activities of Green Company -1. Analysis of Process Flow and Basic Unit (녹색기업의 사업활동 전 과정에 대한 환경성 평가 -1. 공정 흐름 및 원단위 분석)

  • Shin, Choon-Hwan;Park, Do-Hyun
    • Journal of Environmental Science International
    • /
    • v.22 no.3
    • /
    • pp.269-279
    • /
    • 2013
  • In this paper, an environmental assessment was carried out on the whole process of industrial business activities to establish a basic plan for climate change mitigation and energy independency. The whole process was divided into each discharge process in terms of water, air, solid waste, green house gases and refractory organic compounds. The flowcharts and basic unit of process were analysed for three years (2008-2010), being utilized as basic information for the life cycle assessment. It was found that the unit loading for the whole process significantly depends on changes in the operation rate change and highly concentrated wastewater inflow. About 35% of solid waste production was reduced by improving the incineration method with co-combustion in coal boiler, generating about 57% of electricity used for the whole process, and consequently reducing the energy costs. As the eco-efficiency index was found to be more than 1, compared to the previous years, it can be said that improvement in general has taken place.

An Experimental Study on Hydration Heat Control in The Mass Concrete Using Oscillating Capillary Tube Heat Pipe (진동세관형 히트파이프(OCHP)를 이용한 매스콘크리트의 수화열 제어에 관한 실험적 연구)

  • Beak, Dong-Il;Kim, Myung-Sik;Lee, Moon-Sik;Kim, Kang-Min;Yum, Chi-Sun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.409-412
    • /
    • 2006
  • In process of reinforced concrete(RC) box structure, the heat of hydration may cause serious thermal cracking problems. In order to eliminate hydration heat of mass concrete, this paper reports results of hydration heat control in mass concrete using the OCHP(Oscillating Capillary tube Heat Pipe). Recently OCHP is drawn special attention from these points of low cost as well as short construction schedule for the manufacturing of heat exchanger, flexibility, simplification and high performance. There were three RC box molds$(1.2{\times}1.2{\times}1.2m)$ which shows a difference as compared with each other. One was not equipped with OCHP. While others were equipped with OCHP and these were cooled with air natural convection and spraying water respectively. The OCHP was composed of copper pipe with 12 turns(O.D : 4mm, I.D : 2.8mm). The working fluid was R-22 and its charging ratio was 30(Vol. %). In order to analyze the distribution of temperature and index figure of thermal crack in sequential placement of mass concrete, we used HYCON of computer program. As a result of the experiment, the peak temperature decreased about $15.6\sim23.4^{\circ}C$ than the general specimen and the probability of thermal crack generated in mass concrete decreased up to 0%.

  • PDF

A Study on Field Applications of Hydration Heat Control in the Mass Concrete Using Oscillating Capillary Tube Heat Pipe (OCHP를 이용한 매스콘크리트 수화열 제어의 현장적용에 관한 연구)

  • Yum, Chi-Sun;Bae, Won-Mahn;Kim, Myung-Sik;Beak, Dong-Il;Kim, Kang-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.413-416
    • /
    • 2006
  • In process of the mass concrete structure, the heat of hydration may cause serious thermal cracking. In order to eliminate hydration heat of mass concrete, this paper reports results of hydration heat control of mass concrete using the Oscillating Capillary tube Heat Pipe(OCHP). There were the several RC box molds which shows a difference as compared with each other. One was not equipped with OCHP. The others were equipped with OCHP. All of them were cooled with natural air convection. The OCHP was composed of copper pipe with 11 turns(outer diameter : 4mm, inner diameter : 2.8mm) and heat type was non-looped type. The working fluid was R-22 and its charging ratio was 40% by volume. The core of the concrete temperature was approximately $55^{\circ}C$ in the winter without OCHP. But the concrete temperature with OCHP was reduced its difference in temperature with the outdoor temperature to $12^{\circ}C$. Finally we saw the index figure of the thermal crack of the structures were varied from 0.75 to 1.47.

  • PDF

An Experimental Study on the Dispersion Effect of Hydration Heat in the Mass Concrete Using OCHP (OCHP를 이용한 매스콘크리트 수화열 분산효과에 관한 실험적 연구)

  • Kim, Myung-Sik;Baek, Dong-Il;Kim, Kang-Min;Yum, Chi-Sun;Bae, Won-Mahn
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.437-440
    • /
    • 2006
  • In process of the mass concrete structure, the heat of hydration may cause serious thermal cracking. In order to eliminate hydration heat of mass concrete, this paper results of hydration heat control of mass concrete using the Oscillating Capillary tube Heat Pipe(OCHP). There were the several molds which shows a difference as compared with each other. One was not equipped with OCHP. Other were laid with OCHP, and the other were laid in 100cm, and exposed out 50cm. All of them were cooled with natural air convection. The OCHP was composed of copper pipe(outer diameter : 4mm, inner diameter : 2.8mm) and heat type was non-looped type. The working fluid was R-22 and its charging ratio was 40% by volume. The core of the concrete temperature was approximately $53^{\circ}C$ without OCHP. But the concrete temperature with OCHP was reduced its difference in temperature with the outdoor temperature to $12{\sim}15^{\circ}C$. Finally we saw the index figure of the thermal crack of the structures were varied from 0.6 to 1.6.

  • PDF

Clinkering of Sewage Sludge Ash as Cement Raw Material (시멘트 원료로서 하수슬러지 소각재의 클링커링 반응 특성)

  • Ahn, Ji-Whan;You, Kwang-Suk;Cheon, Sung-Min;Han, Ki-Suk;Kim, Hwan
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.4
    • /
    • pp.323-327
    • /
    • 2004
  • This study has been carried out to use the municipal solid waste sewage sludge ash generated at sewage disposal field as the raw materials of Ordinary Portland Cement (OPC). Limestone, shale, converter slag, and fly ash were used as the main raw materials. After the raw materials were mixed, these were fired at 1,300, 1,350, 1,400, 1,450, and 1,500$^{\circ}C$ for 1 h and cooled rapidly in air. The properties of clinker synthesized were examined with XRD, SEM, and burnability index by polysius method.

Utilization of Waste Glass Micro-particles in Producing Self-Consolidating Concrete Mixtures

  • Sharifi, Yasser;Afshoon, Iman;Firoozjaei, Zeinab;Momeni, Amin
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.3
    • /
    • pp.337-353
    • /
    • 2016
  • The successful completion of the present research would be achieved using ground waste glass (GWG) microparticles in self-consolidating concrete (SCC). Here, the influences of GWG microparticles as cementing material on mechanical and durability response properties of SCC are investigated. The aim of this study is to investigate the hardened mechanical properties, percentage of water absorption, free drying shrinkage, unit weight and Alkali Silica Reaction (ASR) of binary blended concrete with partial replacement of cement by 5, 10, 15, 20, 25 and 30 wt% of GWG microparticles. Besides, slump flow, V-funnel, L-box, J-ring, GTM screen stability, visual stability index (VSI), setting time and air content tests were also performed as workability of fresh concrete indicators. The results show that the workability of fresh concrete was increased by increasing the content of GWG microparticles. The results showed that using GWG microparticles up to maximum replacement of 15 % produces concrete with improved hardened strengths. From the results, when the amount of GWG increased there was a gradual decrease in ASR expansion. Results showed that it is possible to successfully produce SCC with GWG as cementing material in terms of workability, durability and hardened properties.

Global warming and biodiversity model projections

  • Ihm, Byung-Sun;Lee, Jeom-Sook;Kim, Jong-Wook
    • Journal of Ecology and Environment
    • /
    • v.35 no.3
    • /
    • pp.157-166
    • /
    • 2012
  • Many models intending to explain the latitudinal gradient of increasing species diversity from the poles to the equator are presented, which are a formalisation of the species-energy hypothesis. The model predictions are consistent with patterns of increasing species number with increasing mean air or water temperatures for plants and animals. An increase in species richness is also correlated with net primary production or the Normalised Difference Vegetation Index. This implies that increased availability of resources favours increased diversity capacity. The explanatory variables included in the biodiversity prediction models represent measures of water, energy, water-energy, habitat, history/evolution and biological responses. Water variables tend to be the best predictors when the geographic scope of the data is restricted to tropical and subtropical areas, whereas water-energy variables dominate when colder areas are included. In major models, about 20-35% of species in the various global regions (European, Africa, etc.) will disappear from each grid cell by 2050 and >50% could be vulnerable or threatened by 2080. This study provides good explanations for predictive models and future changes in biodiversity depending on various scenarios.

A Study for Assessment of Track Accuracy of Phased Array Radar Associated with α-β Filter (α-β 필터를 사용한 위상배열 레이더의 실표적 추적 정확도 평가 알고리듬 연구)

  • Shin, Sang-Jin;Kim, Wan-Gyu
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.9
    • /
    • pp.828-836
    • /
    • 2015
  • In this paper, the assessment technique for track accuracy in the phased array radar is proposed. It is assumed that ${\alpha}-{\beta}$ tracking filter to track the target is established in the phased array radar. In order to assess the track accuracy strictly, we should use the real target position data acquired from the special instrument, ACMI(Air Combat Maneuvering Instrument) pod or DGPS(Differential Global Positioning System). However, this method leads to increase the experiment cost and test time. We derive the relationship between the residuals of tracking filter and the standard deviations of range and angle tracking errors which are assigned as track assessment index. The theory of sample variance is introduced in this assessment because track accuracy has to be calculated with many residual samples.

THERMOSPHERIC NEUTRAL WINDS WITHIN THE POLAR CAP IN RELATION TO SOLAR ACTIVITY

  • Won, Young-In;Killeen, T.L.;Niciejewski, R.J.
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • v.23 no.1
    • /
    • pp.1-11
    • /
    • 1995
  • Thermospheric neutral winds and temperatures have been collected from the ground-based Fabry-Perot interferometer (FPI) at Thule Air Base ($76.5^{\circ}N{\;}69.0^{\circ}W$), Greenland since 1985. The thermospheric observations are obtained by determining the Doppler characteristics f the [OI] 6300 ${\AA}$ emissions of atomic oxygen. The FPI operates routinely during the winter season, with a limitation in the observation by the existence of clouds. For this study, data acquired from 1985 to 1991 were analyzed. The neutral wind measurements from these long-term measurements are used to investigate the influence of solar cycle variation on the high-latitude thermospheric dynamics. These data provide experimental results of the geomagnetic polar cap are also compared with the predictions of two semiempirical models : the vector spherical harmonics (VSH) model of Killeen et al. (1987) and the horizontal wind model (HWM) of Hedin et al. (1991). The experimental results show a good positive correlation between solar activity and thermospheric wind speed over the geomagnetic polar cap. The calculated correlation coefficient indicates that an increase of 100 in F10.7 index corresponds to an increase in wind speed of about 100 m/s. The model predictions reveal similar trends of wind speed variation as a function of solar activity, with the VSH and HWM models tending to overestimate and underestimate the wind speed, respectively.