• Title/Summary/Keyword: air flow

Search Result 7,003, Processing Time 0.043 seconds

An Experimental Study on Blade Deformation of Coaxial Rotor System Using SPR(Stereo Pattern Recognition) Technique (SPR(Stereo Pattern Recognition) 기법을 이용한 동축 로터 블레이드의 변형에 대한 실험적 연구)

  • Yoo, Chanho;Yoon, Byung-Il;Chae, Sanghyun;Kim, Do-Hyung;Kim, Deog-Kwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.8
    • /
    • pp.597-609
    • /
    • 2020
  • These days, the coaxial rotor system is used for various purposes like UAVs, Mars exploration helicopters, and the next-generation high-speed rotorcraft. A number of research projects on aerodynamic performance of rotor systems, including the coaxial configuration have been made previously. On the contrary, research on rotor blade deformation has been mainly carried out regarding the single rotor system, where such effort has not been enough on the coaxial system. Nonetheless, in case of the coaxial system, blade deformation analysis is much more important because of the complex air flow around the rotors, and that the distance between the two rotors is a key factor affects aerodynamic performance of the entire system. For these reasons, an experimental study on rotor blade deformation of the coaxial system was conducted using the Stereo Pattern Recognition(SPR) technique, one of the state-of-the-art of photogrammetry method. In this research, a small-scale coaxial rotor test stand designed by Korea Aerospace Research Institute(KARI) was used. With the same test stand, performance of the coaxial configuration had been studied before the experimental study on blade deformation, in order to find the relation between performance and blade deformation of the rotor system. Results of the performance test and the deformation study are presented in this article.

Growth of Green Pepper(Capsicum annuum L.) in a Plastic Greenhouse Covered with Anti-dropping Plasma Film (방적성 Plasma 처리 필름으로 피복된 플라스틱온실의 풋고추 생육)

  • Chun, Hee;Kim, Kyung-Je;Kim, Jin-Young;Kim, Hyun-Hwan;Lee, Si-Young
    • Journal of Bio-Environment Control
    • /
    • v.9 no.3
    • /
    • pp.156-160
    • /
    • 2000
  • The Plasma film treated with a high electric voltage was developed to enhance flow down of condensation drops on inside plastic film. Arch type greenhouse framed with iron pipe of 25mm diameter defand 1.5mm thickness were covered with either the developed plasma film or surfactant film(control). Green pepper seedlings raised for 40 days in plug trays were transplanted at a density of 110cm by 30cm in each greenhouse. The mount of condensational water on film surface, generated by 7$0^{\circ}C$ water bath chimney systems and flew down, was collected and measured. The amount of collected water after 150 minutes was 2.56 mL.100c $m^{-2}$ and 0.94mL.100c $m^{-2}$ , respectively, in the plasma film and surfactant film-covered greenhouses. The amount of condensational water drops attached on the cover at 08:20 a.m. at 60 days filter covering was 0.34mL.100c $m^{02}$ and 0.32mL.100c $m^{-2}$ , respectively, in the plasma film- and surfactant film-covered greenhouses. Solar irradiance transmitted into greenhouse was 2.0% higher in the greenhouse covered with the plasma film tan that in the greenhouse covered with the surfactant film. Air temperature in the plasma film-covered greenhouse was higher than the surfactant film-covered greenhouse by 0.5$^{\circ}C$. However, there was no difference in relative humidity between the two greenhouse. Plant height, leaf area, dry weight and early yield showed no significant differences.s.

  • PDF

Estimation of THI Index to Evaluate Thermal Stress of Piglets in Summer Season (하절기 자돈 고온 스트레스 평가를 위한 THI 지수 모의)

  • Ha, Taehwan;Kwon, Kyeong-seok;Lee, In-bok;Kim, Rack-woo;Yeo, Uk-hyeon;Lee, Sangyeon;Choi, Hee-chul;Kim, Jong-bok;Lee, Jun-yeob;Jeon, Jung-hwan;Woo, Saemee;Yang, Ka-young
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.4
    • /
    • pp.113-122
    • /
    • 2018
  • Thermal stress of pigs causes decreased feed consumption and weight gain rate, immunosuppression, reproductive disorders, and increased mortality. The concept of the temperature-humidity index (THI) has been widely used to evaluate the degree of thermal stress of pigs. However, use of this concept is strongly restricted for animals living in the enclosed facilities. In this study, Building Energy Simulation (BES) technique was used to realize the energy flow among outside weather conditions, building materials, and animals. Especially, mechanisms of sensible and latent heat generation from pigs according to surrounding air temperature and their weight were designed to accurately evaluate the THI values inside the pig house. The THI values computed by the BES model were compared to those calculated by method of the report (NIAS, 2016), the model of this study predicted the start date of heat stress about 9~76 days earlier compared to the NIAS model. Results of the BES model also showed higher frequencies of the THI above the THI threshold for pigs, indicating that conventional model has a possibility of underestimating the degree of heat stress of pigs.

Simulation Model for Estimating Soil Temperature under Mulched Condition (멀칭에 따른 지온변화 모델의 작성 및 토양온도의 추정)

  • Cui RiXian;Lee Byun-Woo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.1 no.2
    • /
    • pp.119-126
    • /
    • 1999
  • A numerical model using soil surface energy balance and soil heat flow equations to estimate mulched soil temperature was developed. The required inputs data include weather data, such as global solar radiation, air temperature, wind speed, atmospheric water vapor pressure, the optical properties of mulching material, and soil physical properties. The observed average soil temperature at 50 cm depth was used as the initial value of soil temperature at each depth. Soil temperature was simulated starting at 0 hour at an interval of 10 minutes. The model reliably described the variation of soil temperature with time progress and soil depth. The correlation between the estimated and measured temperature yielded coefficient values of 0.961, 0.966 for 5cm and 10cm depth of the bare soil, respectively, 0.969, 0.965 for the paper mulched soil, and 0.915, 0.938 for the black polyethylene film mulched soil. The percentages of absolute differences less than 2$^{\circ}$C between soil temperatures measured and simulated at 10 minute interval were 97.4% and 98.5% for 5 cm and 10cm for the bare soil, respectively, and 95.8% and 97.4% for the paper mulched soil, and 70.1% and 92.5% for the polyethylene film mulched soil. The results indicated that the model was able to predict the soil temperature fairly well under mulched condition. However, in the night time, the model performance was a little poor as compared with day time due to the difficulty of accurate determination of the atmospheric long wave radiation.

  • PDF

In vitro Glutathione Production using Mixed Cells in an Aerated Slurry Bioreactor (혼합세포를 이용한 Aerated Slurry Bioreactor에서의 in vitro Glutathione 생산)

  • Go, Seong-Yeong;Gu, Yun-Mo
    • KSBB Journal
    • /
    • v.14 no.4
    • /
    • pp.445-451
    • /
    • 1999
  • Glutathione production was carried out using mixed cells of E. coli TG1/pDG7 $\alpha$ and bakers yeast in an Aerated Slurry Bioreactor. Glutathione-producing enzymes were stable for 34 hours, yielding 4.6 mM glutathione in suspension reaction. Glutahione production with high density mixed cells was studied as a function of flow rate in an Aereated Slurry Bioreactor. Glutathione concentration was higher than that in suspension reaction for 32 hours at the substrate feeding rate of 5.2 mL/hr with cell recycle in continuous Aerated Slurry Bioreactor. It was for 42 hours at 2.6 mL/hr and 22 hours at 5.2 mL/hr without cell recycle. Glutahione productivity was 25.7 mg/g wet $cell{\cdot}hr$ at the substrate feeding rate of 10.4 mL/hr with cell recycle, but 5.28 mg/g wet $cell{\cdot}hr$ at 5.2 mL/hr and 1.65 mg/g wet $cell{\cdot}hr$ at 2.6 mL/hr without cell recycle. Effective production time increased from 25 to 45 hours, by using a surfactant, tween 80. As a purfing gas, nitrogen was tested instead of air to avoid a possible oxidizing effect on glutathione-producing enzymes, resulting in the increase of effective production time to 40 hours.

  • PDF

Operating Characteristics of a Continuous Two-Stage Bubbling Fluidized-Bed Process (연속식 2단 기포 유동층 공정의 운전특성)

  • Youn, Pil-Sang;Choi, Jeong-Hoo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.1
    • /
    • pp.81-87
    • /
    • 2014
  • Flow characteristics and the operating range of gas velocity was investigated for a two-stage bubbling fluidized-bed (0.1 m-i.d., 1.2 m-high) that had continuous solids feed and discharge. Solids were fed in to the upper fluidized-bed and overflowed into the bed section of the lower fluidized-bed through a standpipe (0.025 m-i.d.). The standpipe was simply a dense solids bed with no mechanical or non-mechanical valves. The solids overflowed the lower bed for discharge. The fluidizing gas was fed to the lower fluidized-bed and the exit gas was also used to fluidize the upper bed. Air was used as fluidizing gas and mixture of coarse (< $1000{\mu}m$ in diameter and $3090kg/m^3$ in apparent density) and fine (< $100{\mu}m$ in diameter and $4400kg/m^3$ in apparent density) particles were used as bed materials. The proportion of fine particles was employed as the experimental variable. The gas velocity of the lower fluidized-bed was defined as collapse velocity in the condition that the standpipe was emptied by upflow gas bypassing from the lower fluidized-bed. It could be used as the maximum operating velocity of the present process. The collapse velocity decreased after an initial increase as the proportion of fine particles increased. The maximum took place at the proportion of fine particles 30%. The trend of the collapse velocity was similar with that of standpipe pressure drop. The collapse velocity was expressed as a function of bulk density of particles and voidage of static bed. It increased with an increase of bulk density, however, decreased with an increase of voidage of static bed.

A Study on the Temporal and Spatial Characteristics of Available Water Resources of Eastern Coastal Area, Korea (동해안지역 가용수자원의 시공간적 특성에 관한 연구)

  • Park, Sang-Deok;Sim, Jae-Hyeon
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.2
    • /
    • pp.165-175
    • /
    • 1997
  • This is to study the characteristics of available water resources (AWR) of the eastern coastal area in Korea. A rating curve was suggested at Yangyang water level station of the Yangyangnamdai river. Annual mean precipitation of this area is 1365.8mm. Annual mean precipitation in central and northern area of eastern coastal area is more than that of southern area because of orographic precipitation occurred by the north-easterly air flow from the East sea. By the correlation analysis of monthly rainfall depths between rainfall gauging stations it is presented that the rainfall gauging stations located in coastal region have the regional representativity, but the rainfall gauging stations located in the westward of mountains have a strong locality. AWR of eastern coastal area by the application of runoff coefficient 0.665 is 1134.5X106m3 and 28.6 percentage for total water resources. In each watershed AWR is 193.7X106m3 in the Yangyangnamdai river, 109X106m3 in the Kangnungnamdai river, and 146.0X106m3 in the Samcheokosip river. The seasonal changes of 30/3% in summer and 19.1% in water, and those of the AWR to total water resources are 86.3% in winter, 60.1% in spring, 50.1% in autumn, and 25.7% in summer. The results of this study may be used to establish the water resources planning of eastern coastal area.

  • PDF

A Study of the Formation of Carbon Monoxide in the Combustion of Anthracite Holed Briquettes (연탄이 연소할 때에 생성되는 일산화탄소에 대한 연구)

  • Han, Dong-Chin
    • Journal of the Korean Chemical Society
    • /
    • v.11 no.4
    • /
    • pp.150-158
    • /
    • 1967
  • When anthracite burns by natural draft the mole percent of carbon monoxide (CO%) contained in exhaust gas is approximately expressed as follows in the early stage of combustion. (CO%)=$\frac{2{\alpha}}{1+{\alpha}}(CO_2%)$ exp $[-\vec{k}(No_2-Nc)^{1/2}{\tau}]$ where ${\alpha}=\frac{-0.395K_p+\sqrt{0.156K^2_p+(0.83+0.21K_p)K_p}}{0.83+0.21K_p}$ and $logK_p =-\frac{8593}{T} + 2.45logT -1.08{\times}10^{-3}T + 1.12{\times}10^{-7}T^2+2.77\vec{k},\;No_2$ and $N_c$ are the rate constant for the reaction ($CO+\frac{1}{2}O_2{\to}CO_2$), mole fraction of oxygen and oxides of carbon contained in the exhaust gas, respectively. From experimental evidence obtained in this work with natural draft combustion of briquettes the percent of carbon monoxide to the total quantity of oxides of carbon produced and rate of air flow into the furnace were: 1.76% and 0.53 l/sec (When lid is used in the furnace) 12.35% and 2.4 l/sec (without use of a lid). is the rate constant for the reaction($CO+\frac{1}{2}O_2{\to}CO_2$) and $N_0,\;and\;N_c$ are respectively the molefraction of oxygen and oxide of carbon contained in the exhaust gas.

  • PDF

An Analysis of the Effect of Climate Change on Byeongseong Stream's Hydrologic and Water Quality Responses Using CGCM's Future Climate Information (CGCM 미래기후정보를 이용한 기후변화가 병성천 유역 수문 및 수질반응에 미치는 영향분석)

  • Choi, Dae-Gyu;Kim, Mun-Sung;Kim, Nam-Won;Kim, Sang-Dan
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.11
    • /
    • pp.921-931
    • /
    • 2009
  • For the assessment of climate change impacts for the Byeongseong stream, CGCM 3.1 T63 is selected as future climate information. The projections come from CGCM used to simulate the GHG emission scenario known as A2. Air temperature and precipitation information from the GCM simulations are converted to regional scale data using the statistical downscaling method known as MSPG. Downscaled climate data from GCM are then used as the input data for the SWAT model to generate regional runoff and water quality estimates in the Byeongseong stream. As a result of simple sensitivity analysis, the increase of CO2 concentration leads to increase water yield through reduction of evapotranspiration and increase of soil water. Hydrologic responses to climate change are in phase with precipitation change. Climate change is expected to reduce water yields in the period of 2021-2030. In the period of 2051-2060, stream flow is expected to be reduced in spring season and increased in summer season. While soil losses are also in phase with water yields, nutrient discharges (i.e., total nitrogen) are not always in phase with precipitation change. However, it should be noted that there are a lot of uncertainties in such multiple-step analysis used to convert climate information from GCM-based future climate projections into hydrologic information.

Separation of Sulfur Dioxide by Circulatory Porous Polymer Membrane Contactor (순환식 고분자 분리막 접촉기를 이용한 이산화황 분리)

  • Lee, Yong-Taek;Jeon, Hyun-Soo;Ahn, Hyo-Seong;Song, In-Ho;Jeong, Heon-Kyu;Lee, Hyung-Keun
    • Membrane Journal
    • /
    • v.17 no.4
    • /
    • pp.302-310
    • /
    • 2007
  • The effects of various system parameter on the absorption of sulfur dioxide into the absorbent liquid were investigated in a circulatory porous polymer membrane contactor. A feed gas and an absorbent used in the study were the gas mixture of air and $SO_2$ and the $Na_2SO_3$ aqueous solution, respectively. The separation of sulfur dioxide was measured in terms of the concentration of $Na_2SO_3$ absorbent, the concentration of sulfur dioxide, the feed flow rate, the absorbent velocity and the different membrane material. As the concentration of absorbent increased from 0.05 to 0.2 M, the removal efficiency increased from 74 to 100%. By increasing the concentration of sulfur dioxide from 700 to 2,500 ppm, the removal efficiency decreased from 100 to 75%. Also as the absorbent velocity increased from 2.5 to 15 mL/min, the removal efficiency increased from 85 to 100%. As the porosity of the membrane increased, the removal efficiency increased.