• Title/Summary/Keyword: air flow

Search Result 6,984, Processing Time 0.033 seconds

A Numerical Analysis of Turbulent Flow Field and Contamination Particles Movements in Rectangular Chambers (장방형 공간내 난류유동및 오염물질 거동의 수치해석)

  • Shim, W.S.;Song, K.C.;Hwang, T.Y.;Shin, Y.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.5
    • /
    • pp.350-364
    • /
    • 1991
  • The movements of small particles distributed uniformly in a steady flow in rectangular chambers having inlets and outlets were simulated numerically. Low Reynolds number turbulent model with a two-equation ($k-{\varepsilon}$) which describes the turbulent characteristics was applied to predict the air flow pattern and particles movements under the condition of the various locations and size of ducts. The calculation results show that the prediction of recirculation zone and stagnation point of flow is important to determine the particles behavior according to the design change. These results will be useful in designing the rectangular chambers for collective protection.

  • PDF

Flow Distribution in Manifold Using Modified Equal Pressure Method (수정된 등압법을 이용한 매니폴드의 유량분배)

  • Ye, Huee-Youl;Kim, Doo-Hwan;Lee, Kwan-Soo;Cha, Woo-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.176-185
    • /
    • 2009
  • A general flow distribution model and a simple process of numerical analysis, which can be applied to multi-pass systems with manifolds, are presented. A numerical procedure, namely a modified equal pressure method based on the discrete model, was developed to predict flow rates at branch tubes. The predicted pressure distribution agreed well with the previous research with the average error less than 11%. A parametric study was performed to demonstrate the effect on the flow distribution.

The optimal parameters in series-series counterflow chillers system within air conditioning (공조장치내의 직렬-직렬 대향류 냉각기에서 최적 변수)

  • Phu, Nguyen Minh;Hung, Bui Ngoc;Lee, Geun-Sik
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1332-1336
    • /
    • 2009
  • If water-chillers are arranged in series-series counterflow, compressor lift of each chiller will be decreased in comparison with water-chillers in parallel. That means that compressor power of the chillers in series will be lower than that of chillers in parallel. However, the pressure drop of the water flow through the chillers in series will increase, and thus increase the power of water pumps. This disadvantage will be made good by increasing the temperature difference of water flow through evaporator and condenser, but the water flow rates will decrease. This paper explores the optimal parameters in system of series-series counterflow for central chilled water plants such as the leaving chilled water temperature, the leaving condenser water temperature, condenser water flow rate and number of chillers in series.

  • PDF

A Flow Quantity Distribution Characteristics of the Hot Water Header for Individual Room Control System (실별제어 온수분배기의 유량분배 특성)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.3
    • /
    • pp.175-180
    • /
    • 2008
  • Flow quantity to supply to a coil in floor heating system is important to achieve comfortable indoor air condition in the winter season. The hot water header is used to distribute the water into the coil. Experimental study has been performed using the water header that have 5 branches consisted of flow control valves and automatic shut-off valves. Each branch line connected it with X-L pipe. Experimental tests accomplished it to investigate the flow distribution characteristics of the hot water header. Experimental results show that the selection of the pump head and differential pressure are very important to save running energy of the system, and high differential pressure needs more friction loss in the case of suitable differential pressure for balancing of the header.

Study on Noise Reduction of An Axial Flow Fan According to the System Characteristics (시스템 특성을 고려한 축류팬 저소음화에 대한 연구)

  • Yoon, Hong-Yeol;Kim, Chang-Jun;Song, Sung-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1381-1385
    • /
    • 2000
  • In this paper, a guideline of axial flow fan design for noise reduction of refrigerators is p resented. Refrigerators have components which have a role to screen particular frequency air borne-noise which is generated by an axial flow fan set in them. Effective ways to use the particular characteristic of refrigerators are shown in this study. As a result of application of the methods, we reduced the noise of the target systems by more than 3 dB(A) from the viewpoint of air-borne noise produced by the axial flow fan set.

  • PDF

Numerical Simulation of Spray Behavior and Its Interaction with Air Flow in Oil Burner (오일 버너에 있어서 분무거동과 공기유동의 상호작용에 관한 수치해석)

  • 나가지마
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.320-330
    • /
    • 1999
  • A numerical study was performed to investigate spray behavior and its interaction with air flow in a flame holding region of an oil burner(0.1MW) using the KIVA3 code. The numerical results in shape of the recirculating flow and size of the recirculation zone under different conditions were compared to those experimental results. The numerical results in fuel droplet trajectory show that a droplet under 30${\mu}m$ can follow the air flow but a droplet over 50${\mu}m$ penetrates the recirculation zone due to large momentum and a droplet of 30-50${\mu}m$ can follow the recirculating flow or pene-trates the recirculation zone.

  • PDF

Numerical Analysis of Nonequilibrium Chemically Reacting Inviscid flow over Blunt-bodies Using Upwind Method (Upwind 방법을 이용한 무딘물체 주위의 화학적 비평형 비점성 유동장의 수치 해석)

  • Seo Jeong Il;Song Dong Joo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.99-105
    • /
    • 1997
  • A finite-difference method based on conservative supra characteristic method type upwind flux difference splitting has been developed to study the nonequilibrium chemically reacting inviscid flow. For nonequilibrium air, NS-1 species equations were strongly coupled with flowfield equations through convection and species production terms. Inviscid nonequilibrium chemically reacting air mixture flows over Blunt-body were solved to demonstrate the capability of the current method. At low altitude flight conditions the nonequilibrium air models predicted almost the same temperature, density and pressure behind the shock as equilibrium flow: however, at high altitudes they showed substantial differences due to nonequilibrium chemistry effect. The new nonequilibrium chemically reacting upwind flux difference splitting mettled can be extended to viscous flow and multi-dimensional flow conditions.

  • PDF

Flow Analysis due to the Angle of the Front Wing on an Airplane (비행기에서의 앞날개의 각도에 따른 유동해석)

  • Han, Moonsik;Cho, Jaeung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.12
    • /
    • pp.22-27
    • /
    • 2019
  • In this study, the flow rate and air resistance pressure were analyzed on models a, b, and c due to the front wing angle of the airplanes. Models a, b, and c have front wing angles of 120°, 100°, and 160°, respectively. The results of the flow analyses showed that the flow rate and air resistance pressure of model c were observed to be higher than models a and b. The airplane model with a larger angle to the front wing is thought to be the best model for flight. This result can be applied to development of the best in-flight airplane.

Analysis of Mixed Convection Heat Transfer in Arbitrarily Shaped Flat Tubes (임의형상을 갖는 납작관에서의 혼합대류 열전달 해석)

  • 박희용;박경우;이상철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.398-410
    • /
    • 2001
  • The flow and heat transfer characteristics for three-dimensional mixed convection flows in a radiator flat tube with U--shaped grooves are analyzed numerically. The flow and temperature fields are calculated by using the modified SIMPLE algorithm for irregular geometry. One tube specification among the various flat tube exchangers is recommended by considering the heat transfer and pressure drop. The effects of variation of coolant flow conditions and external air conditions on the flow and the thermal characteristics for the selected tube are investigated. the results show that inlet velocity of coolant flow is the very important factor in heat transfer and pressure drop, and top side is better position than the others as fin cleave to tube.

  • PDF

Experimental and Numerical Analyses of Unsteady Tunnel Flow in Subway Equiped with Platform Screen Door System (스크린도어가 설치된 지하철에서 열차운행에 의한 비정상유동의 실험 및 수치적 해석)

  • Kim Jung-Yup;Kim Kwang-Yong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.103-111
    • /
    • 2006
  • To optimize the ventilation and smoke control systems in subway equipped with platform screen door, the technology to analyze the unsteady tunnel flow caused by running of train should be developed. The development of model experiment and numerical analysis technique with relation to unsteady flow of subway were presented. The pressure and air velocity changes in 1/20-scaling experiment unit were measured and results were comparied to those of 3-D unsteady numerical analysis applied with sharp interface method. The experimental and numerical results were quantitatively similar and it would be reasonable to apply sharp interface method to analyze the unsteady flow in subway equipped with platform screen door.