• Title/Summary/Keyword: air flow

Search Result 6,984, Processing Time 0.041 seconds

A Study on the Heat Transfer Characteristics Around a Surface-Mounted Air-Cooled Module for the Flow Angle-of-Attack (흐름 영각에 따른 강제공랭 모듈 주위의 열전달 특성에 관한 연구)

  • Park, Sang-Hui;Sin, Dae-Jong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.9
    • /
    • pp.1267-1275
    • /
    • 2002
  • An experimental study was performed to investigate adiabatic wall temperature and heat transfer coefficient around a module cooled by forced air flow. The flow angle of attack to the module were 0$^{\circ}$and 45$^{\circ}$. In the first method, inlet air flow(1~7m/s) and input power.(3, 5, 7W) were varied after a heated module was placed on an adiabatic floor(320$\times$550$\times$1㎣). An adiabatic wall temperature was determinated to use liquid crystal film. In the second method to determinate heat transfer coefficient, inlet air flow(1~7m/s) and the heat flux of rubber heater(0.031~0.062W/$m^2$) were varied after an adiabatic module was placed on rubber heater covering up an adiabatic floor. Additional information is visualized by an oil-film method of the surface flow on the floor and the module. Plots of $T_{ad}$ and $h_{ad}$ show marked effects of flow development from the module and dispersion of thermal wake near the module. Certain key features of the data set obtained by this investigation may serve as a benchmark for thermal-design codes based on CFD.

Flow Visualizations and Hot-Wire Measurements on Air Flow in Two Different Neonate Incubators

  • Kim, Young-Ho;Yoo, Seoung-Chool;Kwon, Chi-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.1051-1060
    • /
    • 2001
  • Flow visualizations and hot-wire measurements on the inside flows of two different incubators are presented in this paper. An anatomically-correct neonate model was fabricated using the rapid prototyping machine, based on the 3-D scanned data. The result showed that air flow in the incubator was affected not only by the air circulation system but also by the design of incubator chamber. Large rotating motions were located around the corners of free space. A number of small eddies were found in regions of high shear flow, in areas such as that between the air inlet and the neonate. But, these small eddies were found to be stationary at that locations. Those small eddies might interfere with convective and evaporative heat transfers from the neonate. This study has led to a better understanding of flow mechanism in an incubator chamber and provided the guidance needed for the advancement of improved computational fluid dynamic models.

  • PDF

Air-Water Two-Phase Flow Test Facility of a Single Stage Closed-type Centrifugal Pump (단단 밀폐형 원심펌프의 기액이상류 성능시험 설비)

  • Kim, S. Y.;Lee, S. L.;Kim, Y. T.;Kim, S. D.;Lee, Y. S.;Lee, Y. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.49-53
    • /
    • 2004
  • LabVIEW is mostly preferred to use in experiment, measurement and control as one of the useful thing in America and Europe. So, We tried performance experiment of a single-stage closed-type centrifugal pump by using the LabVIEW. The pump rpm and the shaft torque are measured by rpm sensor and torque sensor The test pump's maximum rpm, head, kW are 1,750, 13m, and 1.5kW, respectively The casing is made up with transparency acrylic for confirmation the flow patterns. We installed experimental equipment for air water two phase flow. This paper tries to analyze the single-phase flow characteristics through this air water two phase flow experimental apparatus. The performance results of a single-stage closed-type centrifugal pump satisfied reappearance and coincide well with head and coefficients according to the change of rpm.

  • PDF

Experimental investigations on the resistance performance of a high-speed partial air cushion supported catamaran

  • Yang, Jinglei;Lin, Zhuang;Li, Ping;Guo, Zhiqun;Sun, Hanbing;Yang, Dongmei
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.38-47
    • /
    • 2020
  • The partial air cushion supported catamaran (PACSCAT) is a novel Surface Effect Ship (SES) and possesses distinctive resistance performance due to the presence of planing bottom. In this paper, the design of PACSCAT and air cushion system are described in detail. Model tests were carried out for Froude numbers ranging from 0.1 to 1.11, the focus is on the influence of air cushion system on resistance characteristics. Drag-reducing effect of air cushion system was proved by means of contrast tests in cuhionborne and non-cushionborne mode. Wave-making characteristics reflect that the PACSCAT would eventually enter planing regime, in which the air could just escape under the seals and the hull body could operate in a steady state. To acquire different air cushion pressure, air flow rate and leakage height were adjusted during tests. Experimental results show that the resistance performance in planing regime would decrease evidently as the increased air flow rate, however, the scheme with medium leakage height presents the best resistance performance in the hump region.

Characteristics of Wind Flow Variation with Wing Development of Space-Reduced Damper (공간축소형 댐퍼의 날개개도에 따른 풍량변화 특성평가)

  • Baek, Geun-Uk;Baek, Nam-Do;Lee, Myung-Won;Kang, Myungchang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.7
    • /
    • pp.113-120
    • /
    • 2021
  • An experimental device was designed to control the opening of a damper via operating the folding blade drive of the device and to control the amount of air flowing through the damper. In addition, an inverter was installed in the blower to control its fan rotation speed and hence the amount of air flowing through the damper. An experimental study was conducted on the opening of the folding blade damper and changes in the rotational speed of the blower. From the results, the theoretical air volume of the folding blade damper and experimental air volume were observed to be in good agreement within an error range of ±3%. As the mass flow rate of the air passing through the folding blade damper increases proportionally with the changes in damper opening and fan rotation speed, the performance of the damper can be controlled proportionally. The mass flow rate was also observed to increase linearly; therefore, the mass flow rate of the air passing through the folding blade damper increases proportionally with changes in the rotation speed of the blower, such that the performance of the damper is proportional to a constant air volume even with varying rotation speeds of the blower.

Nano Particle Charging Characteristics of Aerosol Charge Neutralizers (에어로졸 중화기의 나노 입자 하전 특성)

  • Ji, Jun-Ho;Bae, Swi-Nam;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1489-1497
    • /
    • 2003
  • Aerosol charge neutralizers with various radioactive sources have been used to apply an equilibrium charge distribution to aerosols of unknown charge distribution. However, the performance of aerosol charge neutralizers is not well known, especially for highly charged particles. Measurements of highly charged particles are needed in air cleaning devices, e.g. electrostatic precipitator, bag filter with a pre-charger, and electrical cyclone. In this study, the particle charging characteristics of two different aerosol charge neutralizers were experimentally investigated for singly charged monodisperse particles and highly charged polydisperse particles. One has radioactive source of $^{85}$ Kr (beta source, 2 mCi) and the other has $^{210}$ Po (alpha source, 0,5 mCi). The air flow rate passing through each aerosol charge neutralizer was changed from 0.2 to 2.5 L/min. The results show that the charge distribution of singly charged monodisperse particles passing through the $^{85}$ Kr aerosol charge neutralizer is well agreed with the Boltzmann equilibrium charge distribution at an air flow rate of 0.3 L/min, However, it deviates from the equilibrium charge distribution when the air flow rates are 0.6, 1,0, and 1,5 L/min, On the other hands, the effect of air flow rate is insignificant for the $^{210}$ Po aerosol charge neutralizer. The non-equilibrium character in charge distribution of highly charged polydisperse particles passing through the $^{85}$ Kr aerosol charge neutralizer greatly depends on the air flow rate, however it is insensitive to the air flow rate for the $^{210}$ Po aerosol charge neutralizer.

Enhanced diffusion by using pulsating flow (왕복유동을 이용한 확산증대 효과에 대한 연구)

  • Hwang, Yong-Sheen;Lee, Dae-Young;Kim, Seo-Young;Choi, Hoon;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.538-541
    • /
    • 2008
  • This study considers the feasibility of the concentration control of the feul and air by oscillating flow in the channel of Fuel Cells. Fuel Cell Stack performance is largely influenced by the fuel and air concentration. If the fuel and air concentration is lower than stoichiometry 1.25 of the fuel and 2.5 of the air, its performance deteriorates seriously because of the fuel and air starvation. In this respect the optimization of the fuel and air concentration is crucially important to maximize fuel cell stack performance. In this work, the effects of oscillating actuation are studied to control the concentration. Two important nondimensional parameters are introduced, each of which represents either the oscillating frequency or the oscillating amplitude. It is shown how these factors affect the stack performance and the efficiency of the fuel cell stack stack.

  • PDF

Characteristics of Intraoral Air Pressure, Airflow in Relation to Phonatory Efficiency in Cleft Palate Speakers

  • Baek, Jin-A;Shin, Hyo-Keun
    • Proceedings of the KSLP Conference
    • /
    • 2003.11a
    • /
    • pp.147-147
    • /
    • 2003
  • Recent aerodynamic and acoustic studies of VPI(velopharyngeal insufficiency) are non-invasive and safety, therefore, many researchers have used it to diagnose the hyper/hyponasality and articulation disorders of cleft palate patients. The purpose of this study was to estimate mainly the oropharyngeal air pressure and over all air flow in cleft lip and palate patients. The pressure-collecting catheter was positioned in the oropharyngel cavity around tongue base. Twelve adult control group and three cleft lip & palate patients were participated to this experimentation. Aerophone II was used to measure peak air flow, mean air flow, phonatory airflow, phonatory efficiency and resistance. The results were as follows: 1) Airflow of cleft lip & palate patients group were higher than those of control group. Fricative sounds /s/ and /s'/ showed the statistic significance of mean airflow and volume data. 2) Intraoral air pressure of cleft lip & palate patients was lower than those of control group.

  • PDF

3-Dimensional Calculation on Cold Air Flow Characteristics in a Refrigerator (냉장고 내부의 냉기 유동특성에 관한 3차원 해석(I))

  • Oh, Min-Jung;Lee, Jae-Heon;Oh, Myung-Do
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.382-395
    • /
    • 1995
  • A numerical study has been performed on flow characteristics in a domestic refrigerator whose size is $540mm{\times}1,530mm{\times}680mm$, considering existence of a fan and evaporator. The flow field has been simulated with the low Reynolds number $k-\bar{\varepsilon}$ turbulent model and SIMPLE algorithm based on the finite volume method. The region of fan which makes driving force for cold air distribution was modeled as a region in which momentum sources are generated uniformly. The concept of the distributed pressure resistance was applied to describe the momentum loss from evaporator. The result showed that the rate of cold air distribution into freezing room and cold storage room was almost 7 : 3.

  • PDF

A Field Test on the Steady State Thermal Performance for the Forced Convection of Large Size Electric Air Heater (대형 전기온풍기 정상상태 열적성능의 현장시험에 관한 연구)

  • 최창용;김홍건
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.99-103
    • /
    • 2002
  • A field test was peformed to estimate the thermal performance of the forced convection electric air heater by the experiment. Air temperature, flow rate and electrical power input were measured with the related measurement sensors, and acquisition methods for the measured data were studied to effectively estimate the thermal performance of the tested air heater. To determine the mean air temperature at the flow cross-section, measuring positions were chosen by considering the flow velocity profile and the equally divided cross-sectional area. From the experimental results, thermal efficiency is obtained as an indication of the tested electric air heater performance.

  • PDF