• 제목/요약/키워드: air exposure time

검색결과 338건 처리시간 0.043초

Indoor Exposure and Health Risk of Polycyclic Aromatic Hydrocarbons (PAHs) in Public Facilities, Korea

  • Kim, Ho-Hyun;Lim, Young-Wook;Jeon, Jun-Min;Kim, Tae-Hun;Lee, Geon-Woo;Lee, Woo-Seok;Lim, Jung-Yun;Shin, Dong-Chun;Yang, Ji-Yeon
    • Asian Journal of Atmospheric Environment
    • /
    • 제7권2호
    • /
    • pp.72-84
    • /
    • 2013
  • In the study, pollution levels of indoor polycyclic aromatic hydrocarbons (PAHs) in public facilities (vapor phase or particulate phase) were evaluated, and a health risk assessment (HRA) was carried out based on exposure scenarios. Public facilities in Korea covered by the law, including underground subway stations, funeral halls, child care facilities, internet cafes (PC-rooms), and exhibition facilities (6 locations for each type of facility, for a total of 48 locations), were investigated for indoor assessment. For the HRA, individual excess cancer risk (ECR) was estimated by applying main toxic equivalency factor (TEF) values suggested in previous studies. Among the eight public facilities, internet cafes showed the highest average $PM_{2.5}$ concentration at $110.0{\mu}g/m^3$ (range: $83.5-138.5{\mu}g/m^3$). When assuming a risk of facility exposure time based upon the results of the surveys for each public facility, the excess cancer risk using the benzo(a)pyrene indicator assessment method was estimated to be $10^{-7}-10^{-6}$ levels for each facility. Based on the risk associated with various TEF values, the excess cancer risk based upon the seven types cancer EPA (1993) and Malcolm & Dobson's (1994) assessment method was estimated to be $10^{-7}-10^{-5}$ for each facility. The excess cancer risk estimated from the TEF EPA (2010) assessment was the highest: $10^{-7}-10^{-4}$ for each facility. This is due to the 10-fold difference between the TEF of dibenzo(a,e)fluoranthene in 2010 and in 1994. The internet cafes where smoking was the clear pollutant showed the highest risk level of $10^{-4}$, which exceeded the World Health Organization's recommended risk of $1{\times}10^{-6}$. All facilities, with the exception of internet cafes, showed a $10^{-6}$ risk level. However, when the TEFs values of the US EPA (2010) were applied, the risk of most facilities in this study exceeded $1{\times}10^{-6}$.

실내.외 통합 모델링 및 인체 위해성 평가를 통한 실내 유해화학물질의 관리 전략 (Management Strategy of Indoor Hazardous Chemicals)

  • 신용승;임혜숙
    • 환경정책연구
    • /
    • 제7권2호
    • /
    • pp.67-90
    • /
    • 2008
  • 본 연구의 목적은 실내 공기내의 유해화학물질의 농도 수준에 영향을 줄 수 있는 요소들을 통합적으로 고려하여 실내 공기질의 관리 전략을 수립하는 것이다. 이러한 목적으로 서울대에서는 실내 공기내의 유해화학물질의 농도 예측을 위한 '통합적 실내 공기질 모델(IIAQ)'을 개발한 바 있다. 본 연구에서는 IIAQ 모델을 사용하여 실내 공기내 유해화학물질의 농도를 도출하고 이 결과를 바탕으로 연구에서 제시된 시나리오에 따른 인체 위해성 평가를 수행하였다. IIAQ 모델을 통해 예측된 톨루엔과 포름알데히드의 10년 평균 농도는 실내에서 207.3 $ug/m^3$, 36.4 $ug/m^3$, 실외에서의 측정값은 55.9 $ug/m^3$, 8.62 $ug/m^3$으로 현재 실내 공기질 기준에 이하인 것으로 나타났다. 그러나 위해성 평가 결과, 포름알데히드의 노출로 인해서 예상 가능한 발암 위해도가 성인 남성 그룹에서 최대 1.05E-03인 것으로 나타났으며, 모든 수용체 그룹에서 자연적인 암 발생률인 1E-06을 초과하는 것으로 나타났다. 반면, 톨루엔에 대한 비발암 위해도는 모든 수용체 그룹에 대해서 1보다 작은 것으로 나타나, 심각하게 우려할 만한 비 발암 위해성이 나타날 가능성은 낮은 것으로 생각된다. 한편 본 연구에서 수행된 신축 공동주택에서 신축 후 10년간의 관심 화학물질인 톨루엔 및 포름알데히드에 농도 변화에 대한 모델링 결과 실내 오염원이 실외 오염원에 비해 실내 공기 오염에 더 큰 비중을 차지하는 것으로 나타나, 유해물질 위해도를 저감하기 위해서는 우선적으로 주요 실내 공기 오염원을 감소시킬 수 있는 전략이 수립되어야 할 필요가 있는 것으로 생각된다. 그리고 위해성 평가 결과는 현재의 실내 공기오염 기준치에 준하게 노출되었을 경우에 발암 위해성이 있을 수 있으므로, 현재의 실내 공기오염 기준치는 실내 외 오염원으로부터의 모든 노출 경로에 대한 총 노출량을 감안하여 총 노출 및 위해성을 감소시킬 수 있는 적절한 기준치로 재정립 되어야 할 필요가 있는 것으로 생각된다.

  • PDF

수술에 사용하는 생리식염수의 오염수준 변화 (A Study on the Contamination of Saline Used in the Operation)

  • 윤혜상
    • 대한간호학회지
    • /
    • 제25권1호
    • /
    • pp.99-109
    • /
    • 1995
  • Post-operative wound infections have been the serious problems in nursing care in the operating room and appear to be strongly related to the infection occurring during the operation. The purpose of this study is to identify the level of contamination in saline used in the operation and also examine the correlation between the contaminated saline and the length of the operation, and unclean atmospheric factor. Subjects for this study include 13 cases of operation performed at the operative theatre of a hospital in Seoul area. Test samples and related data were collected from this medical facility between Oct. 6 through Dec. 10, 1994 by the author and anurse who worked in the operating room. For the study, multiple batches of saline sample were collected at the various time intervals duringthe operation and filtered through the membrane filters. Viable microorganisms retained on the filters were cultured on the appropriate culture media and the levels of existing cells in saline were enumerated according to Koch's method. In the analyses of the data, Pearson's correlation coefficient was obtained for the examination of relationship between the length of operation and numbers of microorganisms existing in saline and for the comparison of the differences in numbers if microrganisms in saline sample collected at the various operative stages, e. g. pre-incision, excision and skin suturing stages, ANOVA and Scheff Tests were performed. The results of this study are summarized as follows. 1) The lenth of the operation and numbers of microorganisms in the saline used in the operation appeared to be significantly correlated (r=0.5467, P<0,001). 2) In case of saline exposed to air, but not used in the operation, the length of exposure to the air and the numbers of microorganisms present in saline also showed an apparent correlation(r=0.5087, P<0. 001). 3) The frequencies of occurrence of microorganisms in saline used in the operation and in saline exposed only to the air in the given time showed significant differences(t=3.73, p=.0000). 4) In case of saline used in the operation, there is significant differences in its numbers of contained microorganisms between the operative stages ; pre-incision, excision, and skin suture (F=17.7500, p=.0000). 5) In case of saline exposed only to the air in the given time, there is significant differences in its numbers of contained microorganisms between the operative stages . pre-incision, excision, and skin suture(F=6.3807, p=.00031).

  • PDF

재난재해 현장의 지형인지를 위한 통합 센서 모듈 개발 (Development of an Integrated Sensor Module for Terrain Recognition at Disaster Sites)

  • 서명국;윤복중;신희영;이경준
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권3호
    • /
    • pp.9-14
    • /
    • 2020
  • A special purpose machine with two manipulators and quadruped crawler system is being developed to work at disaster sites where it is intended to quickly respond in the initial stages after the event. In this study, a terrain recognition module is developed so that the above special purpose machine can quickly obtain ground information to help choose its path while recognizing objects in its way, this is intended to enhance the remote driver's limited situational awareness. Terrain recognition modules were developed for two tasks (real-time path guidance, precision terrain measurements). The real-time path guidance analyzes terrain and obstacles while moving, while the precision terrain measurement feature provides more accurate terrain information by precisely measuring the ground in front of the vehicle while stationary. In this study, an air-cooled sensor protection module was developed so that the terrain recognition module can continue its vital tasks in the event of exposure to foreign substances, including scattered dust, mist and rainfall, as well as high temperatures.

주거환경 공기 중 호흡기 바이러스의 검출 (Detection of Airborne Respiratory Viruses in Residential Environments)

  • 박근태;문경환;김형태;박찬정;정호철;임영희
    • 한국환경보건학회지
    • /
    • 제37권4호
    • /
    • pp.306-314
    • /
    • 2011
  • Objectives: Respiratory virus infections are the most common disease among all ages in all parts of the world and occur through airborne transmission. The purpose of this study was to detect and quantitate human respiratory viruses in residential environments. Methods: Air samples were collected from the residential space of apartments in the Seoul/Gyeonggi-do area. The samples were collected from indoor and outdoor air. Among respiratory viruses, influenza A virus, influenza B virus, parainfluenza virus, metapneumovirus, respiratory syncytial virus, and adenovirus were investigated by multiplex polymerase chain reaction. Among the virus-positive samples, we performed adenovirus quantification by real-time polymerase chain reaction. Results: Virus detection rates were 44.0%, 3.8%, 3.4%, and 17.3% in spring, summer, autumn, and winter, respectively. The virus detection rate was higher in winter and spring than in summer and autumn. Adenovirus was most commonly detected, followed by influenza A virus and parainfluenza virus. Virus distribution was not significantly different between indoor and outdoor environments. Conclusions: Although virus concentrations were not high in residential environments, residents in houses with detected viruses may have an increased risk of exposure to airborne respiratory viruses, especially in winter and spring.

대기중(大氣中) 라돈 붕괴생성물(崩壞生成物)의 공기중(空氣中) 방사능(放射能) 농도(濃度)의 측정(測定) (The Measurement of Airborne Radon Daughter Concentrations in the Atmosphere)

  • 하정우;이재기;문석형;육종철
    • Journal of Radiation Protection and Research
    • /
    • 제4권1호
    • /
    • pp.5-13
    • /
    • 1979
  • 공기시료채칩 종료후 공기여과지에 채집된 시료중 방사능을 일정한 시간구간을 두어 계측함으로써 얻은 붕괴곡선을 이론적 방법에 의하여 분석할 수 있는 간단한 방법을 개발하였으며, 이 방법을 이용하여 라돈 붕괴생성물 각각의 공기중 방사능 농도를 결정하였다. 라돈 붕괴생성물 각 핵종의 방사능 농도는 알파붕괴, 시료채집시간, 그리고 수치계수의 함수로 표시된 방정식으로 부터 얻었다. 그리고 대기중 라돈 붕괴생성물 개개의 방사평형상태도 또한 조사하였다. TRIGA Mark-III 원자로실내에서 채집한 공기시료는 상당히 비평형상태에 있었다. 라돈 붕괴생성물들 간의 방사성 불평형의 정도는 공기와류조건과 관련된 공기시료 채집시간에 따라 상당히 달라지는 것같았다. 본 연구 결과에서 얻은 자료는 인체 내부방사선 피폭선량평가와 기체 방사성 물질 방출감시기 교정에 유용한 기초자료가될 것이 확실하다.

  • PDF

산소분위기의 상압플라즈마를 이용한 페로브스카이트 표면 처리 효과 (Effect of Perovskite Surface Treatment Using Oxygen Atmospheric Pressure Plasma)

  • 김경보;이종필;김무진
    • 융합정보논문지
    • /
    • 제11권6호
    • /
    • pp.146-153
    • /
    • 2021
  • 최근 페로브스카이트 반도체 물질에 대한 연구가 이루어지고 있고, 이 물질에 대한 표면 처리를 이용한 특성 평가는 후속 연구들의 기반이 된다. 따라서, 본 논문에서는 상압분위기에서 플라즈마가 형성되는 상압플라즈마 장비로 산소 플라즈마를 생성하여 공기중에 약 6개월정도 노출시킨 페로브스카이트 박막을 표면 처리한 결과에 대해 연구하였다. 6개월간 노출시킨 이유는 페로브스카이트 박막은 유기물과 무기물로 이루어져 있기 때문에 공기 중에 노출되면, 산소나 수증기와의 반응을 통해 표면이 변화된다. 따라서, 이러한 변화를 원래 막으로의 복원이 가능한지 알아보기 위함이다. 산소플라즈마 분위기에서 1초부터 1200초까지 공정 시간을 변화시켜 가면서 표면 형상과 원소들 비율을 분석하였다. 이러한 결과는 페로브스카이트 막이 시간에 따라 변화가 일어나더라도 플라즈마 처리를 통해 이를 해결하는 방안을 제공한다.

Inactivation influences on Escherichia coli DS5α by irradiation with 405 nm violet-light

  • Young-Sun Kim;Mun-Jin Choi;Dae-Young Lee;Sang-Ook Kang;Geung-Joo Lee
    • 농업과학연구
    • /
    • 제50권3호
    • /
    • pp.459-467
    • /
    • 2023
  • Because an irradiation of 405 nm violet light could have a strong energy, it was used to be sterilized against various microbes in the indoor air condition or fresh food. Escherichia coli is a representative bio-pollutant in the indoor air-borne bacteria, and a hygienic microbe in the horticultural food. This study evaluated the inactivation influences on E. coli DS5α after exposure to 405 nm violet-light (VL) by investigating irradiating time, and the vertical and horizonal distance from light source. The illumination of 405 nm VL was inversely proportional to the distance from the VL source. E. coli DS5α on nutrient agar (NA) was inactivated approximately 50% more than the control when irradiated at 65 cm from 405 nm VL for 3 hours. When compared to the control, E. coli DS5α was inactivated approximately 50% within 70 cm from 405 nm VL for 3 hours. As it was irradiated for 3 hours 70 cm away from 405 nm VL, the horizonal distance from the point was negatively correlated to the inactivation of E. coli DS5α. These results indicated that the inactivation of E. coli DS5α grown on NA medium needs to be irradiated with 405 nm within 70 cm from the light source for 3 hours.

루테늄촉매 활성정도에 따른 유리섬유/폴리다이사이클로펜타다이엔 복합재료의 기계 및 계면물성 변화 (The Change in Interfacial and Mechanical Properties for Glass Fiber/p-DCPD Composites with Degree of Ruthenium Catalyst Activation)

  • 신평수;김종현;백영민;박하승;권동준;박종만
    • 접착 및 계면
    • /
    • 제19권1호
    • /
    • pp.13-18
    • /
    • 2018
  • 루테늄촉매는 대기중에 노출되었을 때, 촉매활성정도가 떨어지게 된다. 루테늄 촉매의 촉매활성변화를 대기노출 일수에 따라 표면장력방법을 이용하여 정량적으로 확인하였다. 각 대기노출일수에 따른 루테늄 촉매를 이용하여 DCPD 중합 후 기계 및 계면물성변화를 확인하였다. 희석제와 10:1로 섞인 루테늄 촉매를 대기 중에 노출 시킨 후 각 일수에 따라 색깔 관찰하였다. 윌헴리 및 PTFE를 이용하여 표면장력을 구하고 이를 촉매활성 정도와 연관시켰다. 각 촉매를 이용하여 DCPD를 중합시키는 데 발열량을 실시간으로 측정하였다. 경화 후 p-DCPD에 대하여 인장강도를 측정하여 물성감소정도를 확인하였다. 또한, 유리섬유 간 마이크로드롭렛 풀 아웃 실험을 통하여 계면물성 또한 파악하였다. 표면장력방법을 통하여 촉매활성 정도를 확인하였을 때, 4일까지는 33 dyne/cm로 안정적이었지만, 6일 이후로 표면장력이 34 dyne/cm 이상 증가하는 것을 확인하였고, 이는 촉매의 산화와 연관시킬 수 있었다. 기계적 물성 확인하였을 때, 인장강도 및 계면강도 또한 6일 (인장강도: 38 MPa. 계면전단 강도: 26 MPa) 까지는 안정적이었지만 10일 (인장강도: 15 MP. 계면전단강도: 3 MPa) 이후로 물성이 급격하게 감소하는 것을 확인하였다.

공기 정복술을 시행 받은 소아 장중첩증 환자들의 치료 결과 및 성공률에 영향을 미치는 요인 (Clinical Features and Factors Affecting Success Rate of Air Reduction for Pediatric Intussusception)

  • 손일태;정규환;박태진;김현영;박귀원;정성은
    • Advances in pediatric surgery
    • /
    • 제16권2호
    • /
    • pp.108-116
    • /
    • 2010
  • Air reduction is a safe, effective, and fast initial treatment for pediatric intussusception. There is low dose radiation exposure. Factors affecting outcomes of air reduction were analyzed by reviewing the clinical features and results of treatment. A total of 399 out of 485 patients with pediatric intussusceptions were treated at the Seoul National University Children's Hospital from 1996 to 2009. All of the patients received air reduction as the first line of treatment. Clinical features such as gender, age, seasonal variation, symptoms, signs, types, pathologic leading point, and treatment results including success rate, complication, recurrence, NPO time, and duration of hospitalization were reviewed. The Pearson chi-square, student T-, and logistic regression tests were used for statistical analysis. P-value less than 0.05 was considered to be statistically significant. The prevalent clinical features were: male (65.4 %), under one-year of age (40.3 %), ileocolic type (71.9 %), abdominal pain (85.4 %), and accompanying mesentery lymph node enlargement (2.2 %). The overall success rate for air reduction was 78.4 % (313 of 399 patients), and the perforation rate during reduction was 1.5 %. There were 23 recurrent cases over 21.6 months. All were successfully treated with re-do air reduction. Reduction failures had longer overall NPO times (27.067hrs vs. 43.0588hrs; p=0.000) and hospitalization durations (1.738d vs. 6.975d; p=0.000) compared to the successful cases. The factors affecting success rates were fever (p=0.002), abdominal distension (p=0.000), lethargy (p=0.000) and symptom duration (p=0.000) on univariate analysis. Failure rates were higher in patients with symptom durations greater than 24 hours (p=0.023), and lethargy (p=0.003) on multivariate analysis. Air reduction showed high success rates and excellent treatment outcomes as the initial treatment for pediatric intussusception in this study. Symptom duration and lethargy were significantly associated with reduced success rates.

  • PDF