• Title/Summary/Keyword: air circulation

Search Result 542, Processing Time 0.025 seconds

Study on Field Experiment of Stack Effect Reduction in Stairwell of Building (건축물 계단에서의 연돌효과 저감방안에 대한 현장실험 연구)

  • Kim, Jung-Yup;Kim, Ji-Seok;Lee, Su-Gak
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.484-490
    • /
    • 2015
  • The winter stack effect that occurs in vertical construction passages such as the stairwell or elevator shaft of a high-rise building negatively affects living environments, energy usage, and personal safety; therefore, a mitigation of the stack effect is required to improve building conditions. Recently, circulation-type facilities that comprise the usage of air blowers and vertical ducts were proposed as part of a mechanical approach to quantitatively control the stack effect. In this study, these circulation-type facilities were installed in a building stairwell and the performance of the device was evaluated during its operation. A numerical-analysis result was obtained under the test conditions using a network-model-based, numerical-analysis method, and the result was then used for a comparison with the test result.

A Study on the Design Qualification of an Isolation Hospital According to Circulation System (동선계획에 따른 격리병동의 설계검증에 관한 연구)

  • Park, Hyun-Jin;Jung, Chung-Soo;Hong, Jin-Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.7
    • /
    • pp.520-527
    • /
    • 2011
  • Recently, Influenza(AI, PI) patients have been increasing rapidly. But, there is a lack of isolation hospitals. In particular, according to increase the rate of patients with airborne infection, in order to prevent the spread of pathogens, design of layout plan and air conditioning system of isolation hospitals becomes more important to maintain patient's room as negative pressure. In this study, the spread of pathogens are analyzed as room differential pressure, moving time of medical staff and patients, and moving way in isolation hospitals by multizone simulation; CONTAM 2.4. Through the analysis, the ways to improve isolation hospital considered at the design step are reached to prevent the spread of pathogens effectively. Also, it verifies that HVAC system for isolation hospital is suitably designed as standard.

Dynamic Characteristics of Thermal Stratification Build-up by Unsteady Natural Convection (비정상 자연대류에 의한 온도성층화의 동특성에 관한 연구)

  • Kang, B.S.;Lee, J.S.;Lee, T.S.;Ro, S.T.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.382-394
    • /
    • 1988
  • Dynamic characteristics of thermally-forced stratification process in a square enclosure with a linear temperature profile at the side walls have been investigated through flow visualization experiment and numerical analysis. The experiment was performed on air with the Rayleigh numbers of order $10^5$. A particle tracer method is used for the flow visualization and to obtain a sudden linear temperature profile at the side walls copper blocks which already have a linear temperature profile are come into contact with the thin copper plates of the test section. Immediately a meridional circulation is developed and heat transfer takes place from the wall to the interior region by circulation of fluid and finally a thermal stratification is achieved. In the numerical study, QUICK scheme for convective terms, SIMPLE algorithm for pressure correction, and the implicit method for the time marching are adopted for the integration of conservation equations. Comparison of flow visualization and numerical results shows that the developing flow patterns are very similar in dynamic nature even though there is a time lag due to the inevitable time delay in setting up a linear temperature profile. For high Rayleigh numbers, the oscillatory motion is likely to take place and stratified region is extended. However, initial temperature adjustment process is much slower than that for low Rayleigh numbers.

  • PDF

Study on the Control of Leaf Mold, Powdery Mildew and Gray Mold for Organic Tomato Cultivation (유기농 토마토 재배시 발생하는 잎곰팡이병, 흰가루병, 잿빛곰팡이병의 방제연구)

  • Hong, Sung-Jun;Park, Jong-Ho;Kim, Yong-Ki;Jee, Hyeong-Jin;Han, Eun-Jung;Shim, Chang-Ki;Kim, Min-Jeong;Kim, Jung-Hyun;Kim, Seung-Hyun
    • Korean Journal of Organic Agriculture
    • /
    • v.20 no.4
    • /
    • pp.655-668
    • /
    • 2012
  • Foliar diseases are major constraints to profitable organic tomato production. Especially, powdery mildew, leaf mold and gray mold of tomato occur severely on organic cultured tomatoes in Korea. This study was conducted to develop organic tomato cultivation technology using environmental-friendly disease control methods (resistance cultivar planting, air circulation fan installation, oil-egg yolk mixtures, and microbial agents). When tomatoes were cultivated in plastic film house installed with air circulation fan, daily range of temperature was decreased by $2{\sim}7^{\circ}C$, average relative humidity was decreased by 1~5% compared to those in plastic house without air circulation fan. Consequently, incidence of tomato leaf mold and tomato gray mold was reduced by 55.0% and 24.4%, respectively. Control effect of microbial agents and oil-egg yolk mixtures against major tomato diseases was examined in plastic house. As a result, the control value of microbial agents against tomato gray mold and tomato leaf mold showed at the range of 49.0~55.9 %(gray mold) and 39.2~58.2%(leaf mold), respectively. The control value of oilegg yolk mixtures against tomato powdery mildew showed 97.6%. Fifteen tomato cultivars were evaluated for disease resistance against leaf mold and powdery mildew in organically cultivated tomato field. Among 15 tomato cultivars, seven cultivars including 'Super-top' were found to be high resistant to tomato leaf mold. Also 'Powerking', one of fifteen tomato cultivars, showed to be high resistant to tomato powdery mildew.

Analysis of Air Temperature and Humidity Distributions and Energy Consumptions according to Use of Air Circulation Fans in a Single-span Greenhouse (단동온실 내 공기순환팬 사용에 따른 온습도 및 에너지소비량 비교 분석)

  • Lee, Tae Seok;Kang, Geum Choon;Kim, Hyung Kweon;Moon, Jong Pil;Oh, Sung Sik;Kwon, Jin Kyung
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.276-282
    • /
    • 2017
  • The aim of this study was to compare and analyze air temperature and humidity distribution and energy consumptions according to using air circulation fans in single-span greenhouses. The greenhouses located in Cheongnam-myeon, Cheongyang-gun, Chungcheongnam-do, Korea. There were cherry tomatoes in the greenhouses and the size of greenhouses was as follows;ridge height : 3.2 m, wide : 6 m, length : 95 m. The heating system was composed of a hot-water boiler and 6 FCUs(Fan Coil Unit)-4 FCUs were on bottom with duct and 2 FCUs were installed at 2.0 m. A total of 18 air circulation fans(impeller's diameter : 230 mm) were bilaterally arranged in 2 rows in the experimental greenhouse. The sensors for measuring air temperature and humidity were located at a quarter and three quarters of a length. The height of sensors were 0.8 m, 1.8 m. To calculate energy consumption in greenhouses, water temperature at inlet and outlet in a water pump, volume of water were measured. Form February 3rd to March 23th, temperature, humidity and energy consumptions were measured during heating time(6pm~7am). In a greenhouse without fans, the average differences of temperature and humidity were $0.75^{\circ}C$, 2.31%, respectively. The operation of fans showed their differences to $0.42^{\circ}C$, 1.8%. The standard deviation of temperature and humidity between measuring points in the greenhouse with fans was lower than the greenhouse without fans. Total energy consumptions in a greenhouse without fans were 4,673 kWh. In the greenhouse with fans, the total energy consumptions were 4,009 kWh. The energy consumptions in a greenhouse with fans 14.2% were less than the greenhouse without fans. Therefore, air circulation makes temperature and humidity uniform and saves energy consumptions for heating.

Performance Improvement of Precooling Process and Cold Box in Hydrogen Liquefaction Process Using LNG Cold Energy (LNG 냉열이용 액체수소 제조공정의 예냉 및 Cold box의 성능 개선 연구)

  • Yun, Sang-Kook;Yoon, Na-Eun
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.56-61
    • /
    • 2020
  • For the hydrogen liquefaction, the large amount of energy is consumed, due to precooling, liquefaction and o-p conversion processes. The aim of this work is to improve the performance of hydrogen liquefaction process by introducing the new energy saving processes, that are the liquid nitrogen precooling process by using LNG cold energy, and the new design of cold box insulation using cold air circulation. The results show that the indirect use of LNG cold energy in precooling process enables not only to get energy saving, but to make safer operation of liquefaction plant. In new cold box, the energy loss of equipments could be reduced by nearly 35%~50% compared to the present perlite insulation, if insulation structure is organised as 3mm steel wall/20cm PUF/5cm air/20cm PUF/equipment. Additionally the equipments installed in cold box can get cooling effect, if the temperature is higher than the temperature of cold air. The application of this results can gives to increase the liquid yield of about 50% substantially in industrial hydrogen liquefaction plant.

A Study on Anti-Icing Technique for Ballast Water of Icebreaking Vessels Operating in Ice-Covered Water (극지운항용 빙해선박의 밸러스트 수 결빙방지 기법 연구)

  • Jeong, Seong-Yeob;Lee, Chun-Ju;Cho, Seong-Rak
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.1
    • /
    • pp.93-97
    • /
    • 2011
  • When freezing is present on ballast water, it can impose additional loads on the hull and effect on stabilization of ship. The anti-icing techniques of ballast water, therefore, are key criteria for ship safety. The existing anti-icing techniques of ballast tank are hull heating, water circulation and air bubble system etc. In this research, anti-icing performance tests for the ballast water using micro-bubble system and sea water circulation system have been carried out at two temperature conditions($-10^{\circ}C$ and $-25^{\circ}C$). Ambient temperature, sea water temperature and temperature of the inner parts of the ballast tank are measured and also ballast water conditions are checked during the model test. The applied anti-icing techniques of ballast water, such as micro-bubble system and sea water circulation system show good performance in the low temperature conditions.

Characteristic analysis and condenser design of gas helium circulation system for zero-boil-off storage tank

  • Jangdon Kim;Youngjun Choi;Keuntae Lee;Jiho Park;Dongmin Kim;Seokho Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.65-69
    • /
    • 2023
  • Hydrogen is an eco-friendly energy source and is being actively researched in various fields around the world, including mobility and aerospace. In order to effectively utilize hydrogen energy, it should be used in a liquid state with high energy storage density, but when hydrogen is stored in a liquid state, BOG (boil-off gas) is generated due to the temperature difference with the atmosphere. This should be re-condensed when considering storage efficiency and economy. In particular, large-capacity liquid hydrogen storage tank is required a gaseous helium circulation cooling system that cools by circulating cryogenic refrigerant due to the increase in heat intrusion from external air as the heat transfer area increases and the wide distribution of the gas layer inside the tank. In order to effectively apply the system, thermo-hydraulic analysis through process analysis is required. In this study, the condenser design and system characteristics of a gaseous helium circulation cooling system for BOG recondensation of a liquefied hydrogen storage tank were compared.

Finite Element Analysis of Swaging Process for Manufacturing of Automotive Air-Conditioning Hose (자동차용 에어콘 호스 제조를 위한 스웨이징 공정 유한요소해석)

  • Min, Kyu-Young;Kim, Tae-Beom;Park, Yong-Bok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1102-1106
    • /
    • 2008
  • It's necessary to invent a measure to deal with expected counter results when observing mechanical behaviors under the various operations and it can be done by measuring the stress and deformation characteristics of the Automotive Air-Conditioner Hose, which is a hose made up of a rubber hose, an aluminum sleeve and pipe. In this paper, characteristics of the stress and deformation characteristics of the Automotive Air-Conditioner Hose which plays an important role in circulation of refrigerant of an air conditioner in an automobile are analyzed using the finite element method.

Air Pollution by Automobiles and Ways of Reduction (자동차가 대기오염에 미치는 영향과 저감방안)

  • 김대식
    • Journal of the Korean Professional Engineers Association
    • /
    • v.34 no.4
    • /
    • pp.69-73
    • /
    • 2001
  • Due to the rapid increase of automobiles and daily driving distances, air pollution by automobiles is still dominant problem of large city in spite of strict emission refutation and development of reduction technologies. Among the air pollution resources of automobile , industry. electricity generation and heating. automobile keeps 51% of total nationwide air pollution in 1998 and this proportion Is increasing in large cities from 65% to 85%. To reduce these air pollution. catalytic converter and electronic engine control, exhaust gas re-circulation and evaporative emission control system have continuously developed and applied to automobiles since 1987. Also strong emission standards and emission durability warranty have enforced and monitored annually by sampling several vehicle models. But technologies and regulations are incomplete, driver should participate in reducing air pollution for himself by planning driving, avoiding unnecessary idle and air conditioning, keeping periodic maintenance and using mass transportation.

  • PDF