• Title/Summary/Keyword: air breathing

Search Result 277, Processing Time 0.025 seconds

A Study on the relation of voice and O-jang(五臟) (음성(音聲)과 오장(五臟)의 관계에 대한 고찰(考察))

  • Baik, You-Sang
    • Journal of Korean Medical classics
    • /
    • v.19 no.2 s.33
    • /
    • pp.97-107
    • /
    • 2006
  • From the study on the relation of voice and O-jang(五臟廳), the conclusion is as follows. The function of breathing out in larynx is involved with lung and kidney. Lung press out the air, at the same time, kidney supports that to maintenance the density of air constantly. So the person who has short breathing can not make strong voice, and also if having a weak kidney in upper Cho[下蕉], their voice will be changed so very softly to cannot make hard type of voice and lingering sounds. Opening and Closing of vocal cords are controled by liver and spleen. when vocal cords are contracted, liver makes tension, whereas spleen does in slackness. So liver is likely to make high-piched sounds in tension of vocal cords, and spleen is the same to do smoothy and husky sounds through relaxing the vocal cords. In the rising condition of liver function, the temp of speech become fast, and more the pronunciation is clearer, it means that the function of thinking by spleen is operated well. Otherwise, indistinct pronunciation means that in the body seup-sa(濕邪) spreads. Also depression of emotion in speech often makes Gi(氣) of heart weaker, whereas it means regular condition of heart including Simpo(心包) that expression of emotion looks happy.

  • PDF

A Study on Stability Improvement of Fuel Metering Unit for Air Breathing Engine (공기흡입식 추진기관용 연료조절밸브 시스템 안정성 향상에 관한 연구)

  • 이도윤;박종승;최현영;구자용
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.9
    • /
    • pp.76-81
    • /
    • 2006
  • This paper deals with a fuel metering unit (referred to as FMU) for air breathing engine. The proposed FMU consists of a constant pressure drop valve and a metering valve, both of which are controlled by servovalve. Linear analysis derived from a nonlinear mathematical model of FMU is carried out to find major parameters on the system performance. Numerical results using established model of FMU were in good agreement with the experimental results. It is also shown that the system stability is improved by reducing the constant pressure drop at metering valve and applying the triangular orifice to constant-pressure-drop valve through the simulation and experiments.

A Study on Fracture Behavior of Scaled Model for Ceramic Dome Port Cover (세라믹 돔포트 커버 상사모델의 파괴거동에 관한 연구)

  • Hwang, Kwon-Tae;Kim, Jae-Hoon;Lee, Young-Shin;Park, Jong-Ho;Song, Kee-Hyuck;Yoon, Soo-Jin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.4
    • /
    • pp.55-62
    • /
    • 2009
  • Fracture behavior of ceramic dome port cover on air breathing engine using liquid and solid fuel propulsion system was carried out in this study. Fracture characteristics was tested and estimated using scaled model of ceramic dome port cover by Shock tube. Fracture behavior was obtained by the fracture pressure from pressure sensor and observed the scattering phenomena of fracture specimen using high speed camera. Results obtained from this study can be used in the base data of dome port cover design for an air breathing engine.

A Measurement Study of a Dynamic Insulator Thermal Performance (동적 단열재의 열성능 측정에 관한 연구)

  • Ko, Seon-Mi;Kang, Eun-Chul;Lee, Euy-Joon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.361-368
    • /
    • 2010
  • Due to the insulation and the air-tightness requirement in modern buildings have resulted NBS(New Building Syndrome) and SBS(Sick Building Syndrome) of IAQ problems. Therefore, energy efficient way of solving such IAQ issues are of major concern in these days and building industries. This paper introduces a method to improve thermal performance with a DI(Dynamic Insulation) concept. The characteristic of the dynamic insulation is that the lower U-value as the higher air velocity through the DI in a micro level. A thermal performance monitoring study has been conducted to show the energy impact of porous DI over the static insulation material. The results show that up to 45% could be improved in the case with DI compared to the conventional insulation.

Case on the Death of Scuba Diver by Analyzing the Air in Nitrox Cylinder (Nitrox 공기통의 기체 분석에 의한 스쿠버다이버 사망원인 추정에 관한 사례연구)

  • Lee, Joon-Bae;You, Jae-Hoon;Shon, Shung-Kun;Sung, Tae-Myung;Paeng, Ki-Jung
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.2
    • /
    • pp.42-47
    • /
    • 2011
  • Going underwater is supposed to begin with the history of human beings. At first it was confined to relatively shallow level, less than several meters by holding breath. Recently, deep level diving has been necessary for such purpose as construction, maritime salvage, military operations, research and sports by using SCUBA(self-contained underwater breathing apparatus) equipment. As one goes down into water, the pressure on the diver is increased due to water pressure with depth, usually 1 atm for each 10 m water level. In deep water, mixed gas or nitrox(EAN, enriched air nitrox) could be applied for the divers lest they should get disease due to high pressure. Of these, the former is usually composed of oxygen and inert gas like helium or hydrogen, the latter contains higher oxygen content than that in normal air in which the oxygen concentration is designated by the character "EAN" followed by vol. % of oxygen, for example, "EAN 40" contains 40% of oxygen. In this case, a victim was found at the 39 m below the sea surface breathing air and nitrox in cylinder wrongly marked as EAN 36, which was analyzed to contain 63% of oxygen by GC/TCD. The cause of death could not be exactly related with the oxygen content in the nitrox cylinder, because the accurate depth for the victim to dive was not known, even though the victim was just found at the depth of 39 m. However, the wrongly marked nitrox could be believed to be the main cause of the death at the depth unless there happened any other accident except that during diving.

Air Sampling For Volatile Organics Using an Adsorbent (흡착제를 이용한 휘발성 유기물 채취)

  • ;L.R.Berrafato
    • Journal of Environmental Science International
    • /
    • v.1 no.1
    • /
    • pp.41-46
    • /
    • 1992
  • To perform a long-term ambient sampling study at a residential site, an air sampler was constructed to collect 24-hour integrated air samples suitable for the volatile organic compounds (VOCs) analysis. It includes an esthetically acceptance due to proximity to homes, as fell as providing the required sampling specifications. The VOCs sampler accomodates four 5/8 "stainless steel(SS) traps packed with adsorbent(Tenax) and is capable of four flow rates in the range of 5 to 50 cc/min. Sintered metal filters(10 micrometer) were directly connected to the inlet of the trap adapters. Additional specifications include: 1) constructed of organically inert materials, 2) weatherproof, 3) battery operated, 4) collecting of VOCs at a breathing zone level, and 5) quiet operation with micro diaphragm pumps wrapped by the sponge. The pump/battery system was separated from the sampling shelter. Sound levels measured for this system were below permissible sound levels (NJDEP) at a residential site. The sampler has been successfully operated at both ground level in a residential area and on the roof of a one story elementary school.hool.

  • PDF

Design of Respiratory Sensor System for polysomnography using Thermocouple (Polysomnography를 위한 열전대 호흡센서 시스템의 설계)

  • 우용규;정도언;박광석
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.121-123
    • /
    • 2000
  • Changes in breathing pattern and apnea both can be !he result of sleep disorders. The focus of this paper is to develop methodologies to monitor the breathing pattern and to detect apnea. An accurate recording of the respiratory phase can be carried out with different methods. One of these methods is the use of a thermocouple, which reacts to the variation in air temperature, placed in the nose and mouth of the patient. The K-type thermocouple was used because it has high reliability, thermo-stability, and good corrosion resistance. And also, it has a considerable long time constant that gives a low cut-off frequency, well below the respiratory frequency and thereby causing a large phase difference. The result showed that timing of respiration was accurately obtained with the AD595, amplifier for K-type thermocouple.

  • PDF

A Study on the Development of Fuel Metering Unit for Air Breathing Engine (공기흡입식 추진기관용 연료조절밸브시스템 개발에 관한 연구)

  • Lee, Do-Yun;Choi, Hyun-Young;Park, Jong-Seung;Koo, Ja-Yoeng
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.8 no.4 s.23
    • /
    • pp.152-158
    • /
    • 2005
  • In this paper, we have proposed a fuel metering unit of ai breathing engine. The proposed valve system consists of a constant pressure drop valve and a metering valve, which are controlled by servovalve. We carried out nonlinear and linear analysis, computer simulation and experimentation to find effects of some factors on system performance. Analysis and experimental results show a good agreement. It is also shown that the system stability is affected by pressure drop of metering valve and inlet pressure of injectors.

A Study on Ventilation Effectiveness Characteristics in a Apartment Housing (공동주택에서 환기효율 특성에 관한 수치적 연구)

  • Cha, Kwang-Suk;Lee, Dae-Woo;Yeom, Dong-Suk;Park, Myung-Sig
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.39-44
    • /
    • 2005
  • Recently according to the fashion of well-being, it is increasing that heat recovery ventilator is applied to the apartment housing, But the uniform locations of inlet and outlet in each room may provide better indoor air quality than ununiform locations of inlet and outlet. Proper design of air supply system requires information concerning the gas concentration difference between the ventilation effectiveness at the breathing line. This paper presents models to predict the gas concentration difference and the ventilation effectiveness, based on the two cases with proper number of outlets. As one of the results it is desirable to set the outlet location near the furniture which produce the contamination gas so much.

  • PDF

Estimation of Ventilation Rates in Korean Homes Using Time-activity Patterns and Carbon Dioxide (CO2) Concentration (시간활동양상 및 이산화탄소 농도를 이용한 한국 주택 환기량 추정)

  • Park, Jinhyeon;Ryu, Hyeonsu;Heo, Jung;Cho, Mansu;Yang, Wonho
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • Objectives: The purpose of this study was to estimate the ventilation rate of residential homes in Korea through tracer gas methods using indoor and outdoor concentrations of carbon dioxide ($CO_2$) and $CO_2$ generation rates from breathing. Methods: In this study, we calculated the number of occupants in a home by time through data on the average number of people per household from the Korean National Statistical Office and also measured the amount of $CO_2$ generation by breathing to estimate the indoor $CO_2$ generation rate. To estimate the ventilation rate, several factors such as the $CO_2$ generation rate and average volume of residential house provided by the Korean National Statistical Office, indoor $CO_2$ concentrations measured by sensors, and outdoor $CO_2$ concentrations provided by the Korea Meteorological Administration, were applied to a mass balance model for residential indoor environments. Results: The average number of people were 2.53 per household and Koreans spend 61.0% of their day at home. The $CO_2$ generation rate from breathing was $13.9{\pm}5.3L/h$ during sleep and $15.1{\pm}5.7L/h$ in a sedentary state. Indoor and outdoor $CO_2$ concentrations were 849 ppm and 407 ppm, respectively. The ventilation rate in Korean residential houses calculated by the mass balance model were $42.1m^3/h$ and 0.71 air change per hour. Conclusions: The estimated ventilation rate tended to increase with an increase in the number of occupants. Since sensor devices were used to collect data, sustainable data could be collected to estimate the ventilation rate of Korean residential homes, which enables further studies such as on changes in the ventilation rate by season resulting from the activities of occupants. The results of this study could be used as a basis for exposure and risk assessment modeling.