• 제목/요약/키워드: affected part

검색결과 1,538건 처리시간 0.024초

준설토의 농축 및 분리를 위한 Hydrocyclone의 적용가능성 평가

  • 오종민;조영민;노성혁
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 추계학술발표회
    • /
    • pp.216-219
    • /
    • 2001
  • In this study, a hydrocyclone operated by centrifugal force was examined as a part of dredge system of lake sediments. It does not help dehydration of the sediments, but also enables the classification of fine particles in the stable and sanitary treatment. Several experiments were performed focusing on the separation efficiency under the condition of room temperature with virtual sediment samples and simulated particles. As a result of the experiment, it was found that the apex size of the cyclone greatly affected the cut diameter(d$_{50}$), and high density particles were separated more effectively.y.

  • PDF

피삼에 의한 송아지 광과민증 1례 (Photosensitization due to the ingestion of Japanese millet (Echinochloa crusgalli) in a Holstein calf)

  • 장광호;이주명
    • 대한수의학회지
    • /
    • 제38권2호
    • /
    • pp.436-440
    • /
    • 1998
  • Photosensitization occurred in a 4-month old Holstein calf soon after going onto the pasture lush with green Japanese millet(Echinochloa crusgalli). Skin lesions were restricted to the unpigmented white area of skin. They were most pronounced on the dorsum of the body, diminishing in degree down the sides and were absent from the ventral part. The demarcation between lesions and normal skin was clearcut. There were edema, exudation and sloughing of affected skin on the left gluteal region, and erythema, edema and scab on right scapular region. Interception of the light, discontinuance of Japanese millet ingestion, and the administration of antihistamine and penicillin made the calf rapid recovery. This disease was considered photosensitization due to chlorphyll in ingested Japanese millet.

  • PDF

Properties of Urea-Formaldehyde Resin Adhesives with Different Formaldehyde to Urea Mole Ratios

  • Park, Byung-Dae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제35권5호
    • /
    • pp.67-75
    • /
    • 2007
  • As a part of abating the formaldehyde emission of urea-formaldehyde (UF) resin adhesive by lowering formaldehyde to urea (F/U) mole ratio, this study was conducted to investigate properties of UF resin adhesive with different F/U mole ratios. UF resin adhesives were synthesized at different F/U mole ratios of 1.6, 1.4, 1.2, and 1.0. Properties of UF resin adhesives measured were non-volatile solids content, pH level, viscosity, water tolerance, specific gravity, gel time and free formaldehyde content. In addition, a linear relationship between non-volatile solids content and sucrose concentration measured by a refractometer was established for a faster determination of the non-volatile solids content of UF resin. As F/U mole ratio was lowered, non-volatile solids content, pH, specific gravity, water tolerance, and gel time increased while free formaldehyde content and viscosity were decreased. These results suggested that the amount of free formaldehyde strongly affected the reactivity of UF resin. Lowering F/U mole ratio of UF resin as a way of abating formaldehyde emission consequently requires improving its reactivity.

Energy Transfer from Ethidium to Cationic Porphyrins Mediated by DNA and Synthetic Polynucleotides at Low Binding Densities

  • Jung, Jin-A;Jeon, Sun-Hee;Han, Sung-Wook;Lee, Gil-Jun;Bae, In-Ho;Kim, Seog-K.
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권8호
    • /
    • pp.2599-2606
    • /
    • 2011
  • The fluorescence of ethidium bound to DNA, poly[d(A-T)$_2$], and poly[d(G-C)$_2$] at a [ethidium]/[DNA] ratio of 0.005 was quenched by porphyrins when both ethidium and the porphyrins simultaneously bound to the same polynucleotide. The quenching was tested using the "inner sphere" and the "Forster resonance energy transfer" (FRET) models, with the latter found to contribute, at least in part, to the quenching. Meso-tetrakis(N-methylpyridinium-4-yl)porphyrin (TMPyP) exhibited a higher quenching and FRET efficiency than cis-bis(N-methylpyridinium-4-yl)porphyrin (BMPyP) for all of the tested DNA and polynucleotides, demonstrating that energy transfer efficiency is affected by the number of positive charges of porphyrins.

소아에서 발생한 직장구불결장의 분절확장에 대한 Laparoscopic-Assisted Transanal Endorectal Pull-Through 술식 (Laparoscopic-Assisted Transanal Endorectal Pull-Through for Segmental Dilatation of Rectosigmoid Colon in a Child)

  • 박지영;박진영
    • Advances in pediatric surgery
    • /
    • 제19권2호
    • /
    • pp.156-161
    • /
    • 2013
  • Congenital segmental dilatation of the colon is a very rare entity of unknown etiology, characterized by a localized dilatation of a bowel segment of the colon of variable length and an abrupt transition between the normal and dilated intestine. It can affect any part of the colon, with the rectosigmoid colon being the most commonly affected site. The clinical and radiological features may resemble that of Hirschsprung disease, but differ in that the normal ganglion cells are found in the dilated and normal segment of the colon. We performed laparoscopic-assisted transanal endorectal pull-through for segmental dilatation of rectosigmoid colon in an 8-year-old boy with chronic constipation since the age of 5 months.

타설형 콘크리트 중단열 벽체의 요구성능 분석 (Performance Requirement of Cast-in-place Concrete with Sandwich Insulation)

  • 박준호;유정호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.10-11
    • /
    • 2014
  • Energy load of building affected by insulation performance of building's exterior. and insulation system can be classify interior insulation, exterior insulation, sandwich insulation according to install place of insulation. but within interior insulation system, corner wall and the cross outer wall-slab insulation part may occur thermal bridges. And then, within exterior insulation system is more superior insulation performance than interior insulation, but it has difficult to apply, easily broken at high building because of strong wind load. And also difficult to maintenance exterior insulation system. So, in this study, to found requirement performance of cast-in-place sandwich insulation system that is superior insulation performance and easy construction and maintenance. requirement performance of cast-in-place sandwich insulation system is 1) To avoid thermal bridges in the insulation performance, 2) Both sides concrete wall can be composite action in the structural performance. Because of this study, can develops cast-in-place sandwich insulation system and this insulation system contribute to improve insulation performance of apartment-house and high building.

  • PDF

연성 효과를 고려한 마이크로스피커 왜율분석 (Analysis of total harmonic distortion in microspeaker considering coupling effect)

  • 권중학;김광석;방기창;황상문
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.236-241
    • /
    • 2008
  • With the advent of mobile phone, Digital multimedia broadcasting (DMB) service is to be realized for multimedia data communication. For an acoustic part, a smaller and lighter microspeaker is also soon to be realized as an MP3 song player and a speakerphone. Sound quality in the microspeaker is becoming more important in mobile phones. It is evaluated by total harmonic distortion (THD). THD is the proportion of higher order frequencies output response to sinusoidal input signal. It is affected by uneven magnetic distribution and nonlinear response of diaphragm. In this paper, harmonic distortion is analyzed by considering magnetic and mechanical coupling effects. Simulated results of THD are compared with experimental data. Results show that THD in lower frequency range is higher due to high displace on voice coil and high mechanical response of high order frequency.

  • PDF

Collaborative and Participatory Model for Urban Forest Management: Case study of Daejisan in Korea

  • Kim, Jae Hyun;Park, Mi Sun;Tae, Yoo Lee
    • 한국산림과학회지
    • /
    • 제95권2호
    • /
    • pp.149-154
    • /
    • 2006
  • Citizen's involvement in forest decision-making is recently acknowledged as a potential solution to forest management conflicts. Through participation, affected citizens become a part of the decision-making process. This paper focuses on the use of collaborative and participatory model(CPM) for urban forest management. The model, which is exemplified by the Daejisan case in Yongin-si, Gyeonggi-do, Korea, utilizes the collaborative decision-making structure and the gradual level of resident participation in urban forest management. As a result, the committee in the model contributed to building partnerships among different interest groups and then to constructing environmentally compatible urban park. Furthermore, an improvement in the levels of resident participation was manifested in the process. These characteristics of CPM can encourage participation and cooperation among stakeholders and ultimately contribute to realizing sustainable urban forest management.

Signal Analysis of Motor Current for End Point Detection in the Chemical Mechanical Polishing of Shallow Trench Isolation with Reverse Moat Structure

  • Park, Chang-Jun;Kim, Sang-Yong;Seo, Yong-Jin
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제2C권5호
    • /
    • pp.262-267
    • /
    • 2002
  • In this paper, we first studied the factors affecting the motor current (MC) signal, which was strongly affected by the systematic hardware noises depending on polishing such as pad conditioning and arm oscillation of platen and recipe, head motor. Next, we studied the end point detection (EPD) for the chemical mechanical polishing (CMP) process of shallow trench isolation (STI) with reverse moat structure. The MC signal showed a high amplitude peak in the fore part caused by the reverse meal. pattern. We also found that the EP could not be detected properly and reproducibly due to the pad conditioning effect, especially when conventional low selectivity slurry was used. Even when there was no pad conditioning effect, the EPD method could not be applied, since the measured end points were always the same due to the characteristics of the reverse moat structure with an open nitride layer.

쇄석 골재의 알칼리-실리카 반응에 관한 실험적 연구( 제 2보 : 첨가알칼리량 및 종류가 알칼리-실리카 반응에 미치는 영향) (A Experimental Study on the Alkali-Silica Reaction of Crushed Stones (Part 2 : The Influence of the Alkali Content and the Kind of Added Alkali to the Alkali-Silica Reaction))

  • 이영수;윤재환;정재동;노재호;이양수;조일호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 가을 학술발표회 논문집
    • /
    • pp.108-112
    • /
    • 1993
  • The term Alkali-Silica Reaction (ASR) is used to describe a reaction between certain siliceous aggregates and hydroxyl ions present in the pore fluid of a concrete. The ASR is affected by the content of alkali, the particle size and the content of reactive aggregate, water-cement ratio, humidity, temperature and so on. In this paper, the fluence of alkali content and kind of added alkali to the ASR was studied. As a result, the more the content of alkali was increased, the more the mortar-bar was expand and the expansion of mortar-bar was showed differently with the added alkali kinds, The reaction products by ASR were observed by SEM(Scanning Electron Microscope) and analyzed by EDXA(Energy Dispersive X-ray Analysis) also and showed a gel composed of alkali(Na+, K+), silica and calcium.

  • PDF