• 제목/요약/키워드: aerosol type

Search Result 137, Processing Time 0.031 seconds

Assessment of Bacterial and Fungal Aerosols in the Kitchens of Restaurants (일부 음식점 주방의 부유세균 및 부유진균 조사연구)

  • Kim, Jong-Gyu;Park, Jeong-Yeong;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.2
    • /
    • pp.98-104
    • /
    • 2014
  • Objectives: The purpose of this study was to determine airborne bioaerosols such as bacteria and fungi in the kitchens of restaurants, and to assess the effects of thermal factors on the levels of the bioaerosols. Methods: Air samples were taken from kitchens of nine restaurants. An Anderson type air sampler was used for sampling and measurements. Petri dishes filled with a microbiological culture medium (trypticase soy agar for bacteria and Sabouraud dextrose agar for fungi) were used as the sampling surface. Results: The levels of bacterial aerosol measured were $10-10^3CFU/m^3$ and fungal aerosol $10-10^2CFU/m^3$, respectively The mean values of air temperature and relative humidity in the kitchens were $24.6^{\circ}C$ and 46.4%, respectively. Overall, the levels of bacterial aerosol varied by the restaurant type, and fungal aerosol by the business period (p < 0.05). The main effect of air temperature and interaction effect of air temperature and relative humidity onto the bacterial level were significant (p < 0.05), whereas the effects were not significant onto the fungal level. Conclusions: The results indicate a wide variation in the levels of bioaerosols among different kitchens. The observed differences in bioaerosol levels in the kitchens reflect different periods of use. The interactions of air temperature and relative humidity onto the bacterial level suggest that constant attention should be paid to avoid peaks of contamination during the summer season.

Performance characteristics of simultaneous removal equipment for paint particulate matter and VOCs generated from a spraying paint booth (입자상물질과 VOCs 동시제거 실증장치에서 자동차 페인트 부스 발생 paint aerosol과 VOCs의 동시제거 성능 특성)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Kim, Kwang-Deuk;Park, Young-Ok
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.161-168
    • /
    • 2016
  • The purpose of this study is to determine the performance characteristics of the paint particulate and volatile organic compounds(VOCs) simultaneous removal from the spraying paint booth in the laboratory and real site by sticky paint particulate and VOCs simultaneous removal demonstration unit. The sticky paint particulate and VOCs simultaneous removal unit is composed of the horizontal type pleated filter modules and the zig-zag type granular activated carbon packing modules. The test conditions at the laboratory are $50.15g/m^3$ of average paint aerosol concentration and 300 ppm of VOCs concentration which were same as the working conditions of spraying paint booth in the real site. But, the demonstration conditions at the real site are varied according to the working condition of spraying paint booth for the kind of passenger car bodies. The test results at the laboratory obtained that 99% of total particulate collection efficiency at 0.62 m/min of filtration velocity and 84% at 1.77 m/min of filtration velocity. The VOCs removal efficiencies are 97% at $3500hr^{-1}$ of gas hour space velocity and 59% at $10,000hr^{-1}$ of gas hour space velocity. In the real site test, the average removal efficiency of PM10 was measured to be 99.65%, the average removal efficiency of PM2.5 was 99.38%, the average removal efficiency of PM1 was 98.52%, and the average removal efficiency of VOCs was 89%.

Validation of MODIS-derived Aerosol Optical Thickness Using SKYNET Measurements over East Asia (SKYNET 관측 자료를 이용한 동아시아 영역에서의 MODIS 에어로솔 광학 두께 산출물 검증)

  • Jang, Hyun-Sung;Song, Hwan-Jin;Chun, Hyoung-Wook;Sohn, Byung-Ju;Takamura, Tamio
    • Journal of the Korean earth science society
    • /
    • v.32 no.1
    • /
    • pp.21-32
    • /
    • 2011
  • Using six-year (2004-2009) SKYNET measurements, MODIS-derived AOTs were validated at five SKYNET sites (Seoul, Chiba, Etchujima, Fukuejima, and Hedomisaki), in addition to climatological analysis of MODIS-derived optical properties over the East Asian domain ($20-50^{\circ}N$, $90-150^{\circ}E$). In so doing MODIS-SKYNET collocated AOT data were constructed if two measurements are taken within 25 km distance and within 30 minute time difference. From the comparison of two measurements, it is demonstrated that aerosol type insignificantly affects the accuracy of MODIS AOT. It is because the aerosol model combining predefined fine aerosol model and coarse aerosol model is used for the retrieval. However, positive bias between MODIS and SKYNET increases as fraction of the coarse aerosol model increases. In addition, MODIS AOT appears to be overestimated in case of lower aerosol loading while the overestimation tends to decrease with increased aerosol loading. Regression analysis between MODIS AOT and SKYNET AOT for 550 nm band yields 0.86, 0.16, and 0.61 of regression slope, intercept, and coefficient of determination, respectively. Those statistical results may draw a conclusion that MODIS AOTs over East Asia carry a reasonable accuracy compared to ground-based SKYNET measurements.

Atmospheric Aerosol Monitoring Over Northeast Asia During 2001 from MODIS and TOMS data (MODIS와 TOMS자료를 이용한 2001년 동북아시아 지역의 대기 에어로졸 모니터링)

  • 이권호;홍천상;김영준
    • Korean Journal of Remote Sensing
    • /
    • v.20 no.2
    • /
    • pp.77-89
    • /
    • 2004
  • The spatial and temporal variations of aerosol optical depth (AOD) over Northeast Asia regions have special importance in the aerosol research for estimation of aerosol radiative forcing parameters and climate change. Aerosol optical and physical properties (AOD and ${\AA}$ngstrom parameter) have been investigated by using Moderate Resolution Imaging Spectroradiometer (MODIS) and Total Ozone Mapping Spectrometer (TOMS) Aerosol Index (AI) to estimate aerosol characteristics over the study region during 2001. Additionally, aerosol characteristics over the Korean peninsular during Aerosol Characteristic Experiment in Asia (ACE-Asia) Intensive Observation Period (IOP) have been investigated by using satellite observations. The results showed that the daily-observed aerosol data indicate seasonal variations with relatively higher aerosol loading in the spring and very low during the winter. The typical Asian dust case showed higher AOD (>0.7) with lower Angstrom exponent (<0.5) and higher AI (>0.5) that is mainly due to the composition of coarse particles in the springtime. Mean AOD for 2001 at 4 different places showed 0.65$\pm$0.37 at Beijing, 0.31$\pm$0.19 at Gosan, 0.54$\pm$0.26 at Seoul, and 0.38$\pm$0.19 at Kwangju, respectively. An interesting result was found in the present study that polluted aerosol events with small size dominated-aerosol loading around the Korean peninsular are sometimes observed. The origin of these polluted aerosols was thought to East China. Aerosol distribution from satellite images and trajectory results shows the proof of aerosol transport. Therefore, aerosol monitoring using satellite data is very useful.

An Experiment on Performance Evaluation of a Direct Atomization Type Air Washer System for Semiconductor Clean Rooms (반도체 클린룸용 직접분무식 에어와셔 시스템의 성능평가실험)

  • Yeo, Kuk-Hyun;Yoo, Kyung-Hoon;Tae, Kyung-Eung
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.988-992
    • /
    • 2006
  • In recent semiconductor manufacturing clean rooms, air washers are used to remove airborne gaseous contaminants such as $NH_3,\;SO_x$ and organic gases from outdoor air introduced into clean room. Meanwhile, there is a large quantity of exhaust air from clean room. It is desirable to recover heat from exhaust air and use it to reheat outdoor air. In the present study, an experiment was conducted to investigate the heat recovery and gas removal efficiencies of a direct atomization type heat recovery air washer.

  • PDF

A Study on the Improvement of Anti-Fire System of Temples (사찰 화재예방시스템의 개선방안에 관한 연구)

  • Kong, Ha-Sung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.87-90
    • /
    • 2008
  • This research is to study and analyze our country's management of disasters, the present condition of cultural heritages bases on the examples of temples, and Japan's safety management prevention of buddhist temple. As a result, this research aims to how to improve the temple fire prevention system. To improve the anti-fire system of temples, it is important to make new laws about fire lose to minimize cultural property lose. Secondly, to protect self-contained type fire alarm device, with aerosol type hand propelled fire extinguishers to prevent fire lose. Lastly, construction work of electric engineer is necessary to prevent temple fire loses.

A Study on the Characteristic and AOD Variation according to Aerosol Types Using AERONET Sunphotometer Data in Korea (AERONET 선포토미터 자료를 이용한 국내 에어로졸 유형별 특성과 광학적 두께 변화 연구)

  • Joo, Sohee;Dehkhoda, Naghmeh;Noh, Youngmin
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_1
    • /
    • pp.93-101
    • /
    • 2020
  • For the first time in Korea, aerosol type was separated as PD (Pure dust), DDM (Dust Dominant Mixed), PDM (Pollution Dominant Mixed), NA (Non-Absorbing), WA (Weakly Absorbing), MA (Moderately Absorbing), and SA (Strongly Absorbing) using depolarization ratio and single-scattering albedo based on AERONET sunphotometer data. Then, seasonal and annual occurrence frequency and AOD variation are analyzed. The proportion of pollution aerosols (NA, WA, MA, SA combined) was 58.9, 46.2, 59.5, and 67.1% at Anmyeon, Gosan, Gwangju, Seoul, respectively, with Seoul being the highest and the lowest at Gosan. Annual rate changestended to increase NA and decrease PD and DDM. The AOD by type showed the highest NA at all sites. In addition, the ratio of NA and AOD continued to increase.

A Study on Collecting Electrode Design for Developing Electrostatic Precipitator(ESP) of Urban Railway Underground Tunnels (도시철도 지하터널용 전기집진기 개발을 위한 집진극 형상에 대한 기초연구)

  • Koo, Tae Yong;Kim, Yong Min;Hong, Jung Hee;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.9 no.2
    • /
    • pp.79-87
    • /
    • 2013
  • In this study, the characteristics of turbulent flow and collection efficiency for an one-stage electrostatic precipitator(ESP) with slit type collecting electrode for urban railway underground tunnels were obtained using computational fluid dynamics(CFD) commercial code FLUENT 6.3 and lab-scale experiments. The electrostatic precipitator was operated under high gas velocity(3~12m/s). Five different designs of collecting electrode, flat plate-type and a slit-type of 3mm, 5mm, 7mm and 10mm slit width and four various gas velocity(3, 6, 9, and 12m/s) were used and applied. A standard k-${\varepsilon}$ model in CFD commercial code FLUENT 6.3 was used for flow simulation. The flow simulation results showed that the turbulent intensity of flat plate-type was higher than slit-type under all gas velocity conditions and also the turbulent intensity of flat plate-type was increased continuously, but in case of slit-type was maintained at constant range. And, the turbulent intensity was decreased according to increasing of slit width. The experimental results showed that the collection efficiency of slit-type was higher than flat plate-type under all gas velocity conditions. And, over 6m/s gas velocity condition, the collection efficiency of 5mm and 7mm was highest, when compared to 3mm and 10mm.

Development of Drying Systems for Accurate Measurement of Particulate Matter by means of Optical Particle Measuring Instruments (광산란 계측기의 미세먼지 측정 정확도 향상을 위한 수분제거 전처리 기술 개발)

  • Kang, Doo Soo;Oh, Jung Eun;Lee, Sang Yul;Shin, Hee Joon;Bong, Ha Kyung;Choi, Joohyun;Kim, Dae Seong
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.191-203
    • /
    • 2018
  • IIn this study, we have developed drying systems for reducing the error by humidity on measuring particulate matter (PM) in the ambient air with optical particle measuring instruments. Two types of drying systems were designed: drying systems using heating and dilution methods. In addition, 3 types of drying systems using a heating method were designed: Type A (1 hole), B (3 holes) and C (7 holes). After making them, the laboratory and field tests were carried out to evaluate the developed drying systems. As a result, it was shown that the PM concentrations obtained by PM monitoring devices with drying systems agree well with that of the reference devices. Therefore, it could be concluded that the drying systems can be applied to PM monitoring devices for real-time monitoring of the ambient aerosols.

Investigation of decontamination characteristics of a serial multiple pool scrubber system for consequence mitigation of severe accidents

  • Hyeon Ho Byun;Man-Sung Yim
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4585-4600
    • /
    • 2022
  • A pool scrubber is often used as a wet-type design to mitigate the consequence of a severe nuclear accident. While studies indicated higher decontamination performance of a deeper pool, utilizing a very tall pool can be problematic due to potential structural stability and water backflow issues. This study proposes, as an alternative to a single pool system, a pool scrubber system composed of serially connected multiple pools with lower heights. Since large fraction of aerosol removal takes place in the injection region, serially connected pool scrubber system is expected to enhance the overall decontamination capability of a pool scrubber system. To support the analysis of the proposed system's decontamination capability, a new computer model was developed in the study to describe the bubble size dependent effect on aerosol removal including the effect of pool residence time. The accuracy of the new model was examined against experimental data for its validation. The proposed scrubber system composed of serially connected multiple shorter pools is found to have much improved decontamination performance over the current single pool system design.