• 제목/요약/키워드: aerosol type

Search Result 137, Processing Time 0.037 seconds

Analysis of Aerosol Optical Properties for High Particulate Matters and Light Asian Dust in Seoul Using GOCI (GOCI 자료를 이용한 서울 지역 고농도 미세먼지와 옅은 황사 시 에어로졸 광학적 특성 분석)

  • Kim, Deok-Rae;Choi, Won-Jun;Choi, Myungje;Kim, Jiyoung;Cho, Ara;Kim, Sang-Kyun;Kim, Jhoon;Moon, Kyung-Jung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.3
    • /
    • pp.233-240
    • /
    • 2017
  • To distinguish between high particulate matter (HPM) and light Asian dust (LAD) events, aerosol optical properties from GOCI were investigated in Seoul from 2014 to 2016. The poor air quality case caused by fine atmospheric particulate matter (i.e., 80<$PM_{10}$<$400{\mu}g/m^3$) is clearly separated from the case of heavy Asian dust that generally shows the $PM_{10}$ concentration more than $400{\mu}g/m^3$. In this study, we have found eight cases for the poor air quality and divided them into the two events(i.e., HPM and LAD). In case of aerosol optical depth (AOD), there was no big difference between two events. However, Angstrom exponent (AE) for HPM events was greater than 1, while that for LAD events less than 1. As a result of comparing aerosol type, non-absorbing fine mode aerosols were dominant for HPM events, but coarse and absorbing coarse mode aerosols for LAD events. Therefore, AE and aerosol type from GOCI can be used to distinguish between two events effectively.

Eco-Friendly Synthesis of Rod-Like Potassium Hexatitanate Particles (친환경 공정에 의한 봉상형 육티탄산칼륨 입자의 제조)

  • Lee, Chongmin;Chang, Hankwon;Jang, Hee Dong
    • Particle and aerosol research
    • /
    • v.13 no.4
    • /
    • pp.183-189
    • /
    • 2017
  • Potassium hexatitanate ($K_2Ti_6O_{13}$) with high thermal insulating capacity, good mechanical properties, and excellent chemical stability are promising functional materials in the field of reinforcing material, heat insulating paints and automotive brake linings. In this study, we successfully synthesized rod-shaped potassium hexatitanate ($K_2Ti_6O_{13}$) by aerosol spray drying and post heat treatment as an eco-friendly process. The $KHCO_3-TiO_2$ porous particles were firstly synthesized from a colloidal mixture of $K_2CO_3$ and $TiO_2$ via aerosol spray drying. Size of $KHCO_3-TiO_2$ porous particles was ranged from $1{\mu}m$ to $5{\mu}m$. The porous particles were then heated to fabricate rod-type $K_2Ti_6O_{13}$. The length and width of rod-type composites were affected by temperature and heating time. The length and width of $K_2Ti_6O_{13}$ were increased by 830 nm and 500 nm, respectively, as the reaction temperature and time increased.

A Study on the Influence of Corrosion of Metals and Plants through Aerosol Type Spraying of Agricultural Pesticide Products Containing Insecticide Ingredients (살충제 성분이 함유된 농약제품의 에어로졸 분사에 따른 금속 및 식물의 부식 영향에 관한 연구)

  • Kim, Jeong Hun
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.8-14
    • /
    • 2018
  • Recently, serious problems occurred such as insecticide eggs, sanitary pads with carcinogens, radon(Rn) emitting beds in domestic. It had not been establishing the inspection system to evaluate safety and human harmfulness before occurring real accidents. This research was conducted to test preliminary experimental inspection for consideration of safety insensibility. The influence of corrosion of metals and plants was studied through aerosol type spraying of agricultural pesticide products coming into the market. These products contain primary three insecticide ingredients(Flufenoxuron, Etoxazole, Fipronil) in recent accidents. Visual examination, SEM-EDS and optical microscope were used for the analysis for corrosion effect. Results show that a lot of ingredients contain in the crop protection products, and various type of corrosion exist in the surface of metals and plants. Therefore, it is necessary to provide health warning and accurate range of use for crop protection products containing insecticide ingredients.

Evaluation of Removal Efficiency of Water Contents using Inertial Impaction Separator (관성 충돌 방식의 액적 분리장치의 수분제거효율 평가)

  • Lee, Sin Young;Hong, Won Seok;Shin, Wanho;Kim, Gyujin;Song, Dong Keun
    • Particle and aerosol research
    • /
    • v.9 no.1
    • /
    • pp.23-29
    • /
    • 2013
  • Inertial impaction type mist eliminators are the most effective instruments to separate mist from the gas. In this work, the effect of the horizontal chevron type mist eliminators is characterized experimentally. Droplet size distribution and evaluation of removal efficiency of the chevron type mist eliminators at different gas flows were investigated using an aerosol particle size analyzer and a portable aerosol spectrometer, respectively. The experimental investigations showed that the mist removal efficiency in these instruments is dependent in the droplet size, and the pressure drop is nil.

The Experimental Study of SPM(Selectively Permeable Membrane Materials) by using Aerosol Test Instrument (에어로졸 시험장비를 이용한 방호 의복 소재의 여과 효율에 대한 연구)

  • Kwon, Tae Geun;Seo, Hyeon Kwan;Kim, Jin Won;Kang, Jae Sung;Kang, Ki Tae;Ahn, Kang Ho;Choi, Jin Soo;Cho, Jae Ho;Kwon, Yong Taek;Park, Hyen Bae
    • Particle and aerosol research
    • /
    • v.10 no.3
    • /
    • pp.109-117
    • /
    • 2014
  • In Korea, permeable protection clothes for chemical agent is being developed and distributed. But permeable protection clothes are vulnerable for biological agent of particle type. Therefore selective permeable membranes are being developed to protect chemical agent and biological agent simultaneously. In this study, aerosol collection efficiency test was performed to validate the protection performance of permeable clothes and selective permeable membranes. Aerosol collection efficiency test was performed by using the aerosol test equipment that could test aerosol particle diameter from $0.005{\mu}m$ to $3.0{\mu}m$. This study shows the test method and performance test results for collection efficiency by using the aerosol test equipment.

Sensitivity of COMS/GOCI Measured Top-of-atmosphere Reflectances to Atmospheric Aerosol Properties (COMS/GOCI 관측값의 대기 에어러솔의 특성에 대한 민감도 분석)

  • Lee, Kwon-Ho;Kim, Young-Joon
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.6
    • /
    • pp.559-569
    • /
    • 2008
  • The Geostationary Ocean Color Imager (GOCI) on board the Communication Ocean Meteorological Satellite (COMS), the first geostationary ocean color sensor, requires accurate atmospheric correction since its eight bands are also affected by atmospheric constituents such as gases, molecules and atmospheric aerosols. Unlike gases and molecules in the atmosphere, aerosols can interact with sunlight by complex scattering and absorption properties. For the purpose of qualified ocean remote sensing, understanding of aerosol-radiation interactions is needed. In this study, we show micro-physical and optical properties of aerosols using the Optical Property of Aerosol and Cloud (OPAC) aerosol models. Aerosol optical properties, then, were used to analysis the relationship between theoretical satellite measured radiation from radiative transfer calculations and aerosol optical thickness (AOT) under various environments (aerosol type and loadings). It is found that the choice of aerosol type makes little different in AOT retrieval for AOT<0.2. Otherwise AOT differences between true and retrieved increase as AOT increases. Furthermore, the differences between the AOT and angstrom exponent from standard algorithms and this study, and the comparison with ground based sunphotometer observations are investigated. Over the northeast Asian region, these comparisons suggest that spatially averaged mean AOT retrieved from this study is much better than from standard ocean color algorithm. Finally, these results will be useful for aerosol retrieval or atmospheric correction of COMS/GOCI data processing.

Feasibility study of a resistive-type sodium aerosol detector with ZnO nanowires for sodium-cooled fast reactors

  • Jewhan Lee;Da-Young Gam;Ki Ean Nam;Seong J. Cho;Hyungmo Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2373-2379
    • /
    • 2023
  • In sodium systems, leakage is one of the safety concerns; it can cause chemical reactions, which may result in fires. There are contact and non-contact types of leak detectors, and the conventional method of non-contact type detection is by gas sampling. Because of the complexity of this method, there has always been a need for a simple gas sensor, and the resistive-type nanostructure ZnO sensor is a promising option with various advantages. In this study, a ZnO sensor was fabricated, and the concept was tested as a leak detector using a dedicated experiment facility. The experiment results showed distinctive changes in resistance with the presence of sodium aerosol under various conditions. Replacing the conventional gas sampling with the ZnO sensors is expected to enable identification of the leakage location if used as a point-wise instrumentation and to greatly reduce the total cost, making the system simple, light, and effective. For further study, more tests will be performed to evaluate the sensitivity of key parameters under various conditions.

Operational Atmospheric Correction Method over Land Surfaces for GOCI Images

  • Lee, Hwa-Seon;Lee, Kyu-Sung
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.1
    • /
    • pp.127-139
    • /
    • 2018
  • The GOCI atmospheric correction overland surfaces is essential for the time-series analysis of terrestrial environments with the very high temporal resolution. We develop an operational GOCI atmospheric correction method over land surfaces, which is rather different from the one developed for ocean surface. The GOCI atmospheric correction method basically reduces gases absorption and Rayleigh and aerosol scatterings and to derive surface reflectance from at-sensor radiance. We use the 6S radiative transfer model that requires several input parameters to calculate surface reflectance. In the sensitivity analysis, aerosol optical thickness was the most influential element among other input parameters including atmospheric model, terrain elevation, and aerosol type. To account for the highly variable nature of aerosol within the GOCI target area in northeast Asia, we generate the spatio-temporal aerosol maps using AERONET data for the aerosol correction. For a fast processing, the GOCI atmospheric correction method uses the pre-calculated look up table that directly converts at-sensor radiance to surface reflectance. The atmospheric correction method was validated by comparing with in-situ spectral measurements and MODIS reflectance products. The GOCI surface reflectance showed very similar magnitude and temporal patterns with the in-situ measurements and the MODIS reflectance. The GOCI surface reflectance was slightly higher than the in-situ measurement and MODIS reflectance by 0.01 to 0.06, which might be due to the different viewing angles. Anisotropic effect in the GOCI hourly reflectance needs to be further normalized during the following cloud-free compositing.

Separate and integral effect tests of aerosol retention in steam generator during tube rupture accident

  • Lee, Byeonghee;Kim, Sung-Il;Ha, Kwang Soon
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2702-2713
    • /
    • 2022
  • A steam generator tube rupture accompanying a core damage may cause the fission product to be released to environment bypassing the containment. In such an accident, the steam generator is the major path of the radioactive aerosol release. AEOLUS facility, the scaled-down model of Korean type steam generator, was built to examine the aerosol removal in the steam generator during the steam generator tube rupture accident. Integral and separate effect tests were performed with the facility for the dry and flooded conditions, and the decontamination factors were presented for different tube configurations and submergences. The dry test results were compared with the existing test results and with the analyses to investigate the aerosol retention physics by the tube bundle, with respect to the particle size and the bundle geometry. In the flooded tests, the effect of submergence were shown and the retention in the jet injection region were presented with respect to the Stokes number. The test results are planned to be used to constitute the aerosol retention model, specifically applicable for the analysis of the steam generator tube rupture accident in Korean nuclear power plants to evaluate realistic fission product behavior.