• Title/Summary/Keyword: adopted measure

Search Result 645, Processing Time 0.026 seconds

A Study of the Cooling Effect of an Evaporation-Type Cool Roof Fan (기화방열식 Cool Roof Fan의 냉풍효과에 대한 연구)

  • Kim, Yeong Sik;Chung, Hanshik;Jeong, Hyomin;Choi, Soon-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.191-200
    • /
    • 2016
  • The ventilation effect of a ventilation system, which is classified as the forced ventilation and natural ventilation, is predominantly dependent on the combination of air supply and discharge. Perhaps the simplest ventilation is merely supplying the air as it is. However, to improve the indoor working environment during the summer, an air supply that is cooled to some extent has been widely adopted. Recently, a cooling method utilizing the vaporization of water was introduced. In this study, the performance of an evaporation-type air supply unit that was produced by Japan K-company and was installed in a shoe-manufacturing plant in Busan was investigated. The purpose of the experiment was to measure how much the supplied air could be cooled. From this experimental study, we confirmed that the evaporation-type air supply system is efficient, capable of improving the working environment during the summer while minimizing the energy cost.

Regional frequency analysis using spatial data extension method : I. An empirical investigation of regional flood frequency analysis (공간확장자료를 이용한 지역빈도분석 : I. 지역홍수빈도분석의 실증적 검토)

  • Kim, Nam Won;Lee, Jeong Eun;Lee, Jeongwoo;Jung, Yong
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.5
    • /
    • pp.439-450
    • /
    • 2016
  • For the design of infrastructures controlling the flood events at ungauged basins, this study tries to find the regional flood frequencies using peak flow data generated by the spatial extension of flood records. The Chungju Dam watershed is selected to validate the possibility of regional flood frequency analysis using the spatially extended flood data. Firstly, based on the index flood method, the flood event data from the spatial extension method is evaluated for 22 mid/smaller sub-basins at the Chungju Dam watershed. The homogeneity of the Chungju dam watershed was assessed in terms of the different size of watershed conditions such as accumulated and individual sub-basins. Based on the result of homogeneity analysis, this watershed is heterogeneous with respect to individual sub-basins because of the heterogeneity of rainfall distribution. To decide the regional probability distribution, goodness-of fit measure and weighted moving averages method from flood frequency analysis were adopted. Finally, GEV distribution was selected as a representative distribution and regional quantile were estimated. This research is one step further method to estimate regional flood frequency for ungauged basins.

A Historical Review on the Introduction of Chugugi and the Rainfall Observation Network during the Joseon Dynasty (조선시대 측우기 등장과 강우량 관측망에 대한 역사적 고찰)

  • Cho, Ha-man;Kim, Sang-Won;Chun, Young-sin;Park, Hye-Yeong;Kang, Woo-Jeong
    • Atmosphere
    • /
    • v.25 no.4
    • /
    • pp.719-734
    • /
    • 2015
  • Korea is one of the country with the world's oldest meteorological observation records. Starting with first meteorological record of fog in Goguryeo in the year of 34 BC, Korea had left a great deal of quantitative observation records, from the Three Kingdoms Period to Goryeo to Joseon. During the Joseon Dynasty, with a great attention by kings, efforts were particularly made to measure rainfall in a systematic and scientific manner. In the 23rd year of King Sejong (1441), the world's first rain gauge called "Chugugi" was invented; in the following year (1442), a nationwide rainfall observation network was established. The King Sejong distributed Chugugi to 350 observation stations throughout the state, even to small towns and villages, for measuring and recording rainfall. The rainfall observation using Chugugi, initiated by King Sejong, had been in place for about 150 years, but halted during national disturbances such as Japanese invasion of Korea in 1592. Since then, the observation had been forgotten for a long time until the rainfall observation by Chugugi was resumed in the 48th year of King Yeongjo (1770). King Yeongjo adopted most of the existing observation system established by King Sejong, including the size of Chugugi and observation rules. He, however, significantly reduced the number of Chugugi observation stations to 14, and commanded the 352 local authorities such as Bu, Gun, Hyeon to conduct "Wootaek", a method of measuring how far the moisture had absorbed into the soil when it rains. Later on, six more Chugugi stations were established. If the number of stations of Chugugi and Wootaek are combined together, the total number of rainfall observation station in the late period of Joseon Dynasty was 372. The rainfall observation with Chugugi during the Joseon Dynasty is of significance and excellence in three aspects: 1) the standard size of Chugugi was so scientifically designed that it is as great as today's modern rain gauge; 2) rainfall was precisely measured, even with unit of Bun (2 mm); and 3) the observation network was distributed on a nationwide basis.

High-Level Production of High-Purity Human and Murine Recombinant Prion Proteins Functionally Compatible to In Vitro Seeding Assay

  • Hwang, Hae-Gwang;Kim, Dae-Hwan;Lee, Jeongmin;Mo, Youngwon;Lee, Se-Hoon;Lee, Yongjin;Hyeon, Jae Wook;Lee, Sol Moe;Cheon, Yong-Pil;Choi, Eun-Kyoung;Kim, Su Yeon;Lee, Yeong Seon;Son, Young-Jin;Ryou, Chongsuk
    • Journal of Microbiology and Biotechnology
    • /
    • v.28 no.10
    • /
    • pp.1749-1759
    • /
    • 2018
  • Recombinant (rec) prion protein (PrP) is an extremely useful resource for studying protein misfolding and subsequent protein aggregation events. Here, we report mass production of high-purity rec-polypeptide encoding the C-terminal globular domain of PrP; (90-230) for human and (89-231) for murine PrP. These proteins were expressed as His-tagged fusion proteins in E. coli cultured by a high cell-density aerobic fermentation method. RecPrPs recovered from inclusion bodies were slowly refolded under reducing conditions. Purification was performed by a sequence of metal-affinity, cation-exchange, and reverse-phase chromatography. The current procedure yielded several dozens of milligrams of recPrP per liter with >95% purity. The purified recPrPs predominantly adopted an ${\alpha}$-helix-rich conformation and were functionally sufficient as substrates to measure the seeding activity of human and animal prions. Establishment of a procedure for high-level production of high-purity recPrP supports the advancement of in vitro investigations of PrP including diagnosis for prion diseases.

Measurement of the Device Properties of Photoelectric Smoke Detector for the Fire Modeling (화재모델링을 위한 광전식 연기감지기의 장치물성 측정)

  • Cho, Jae-Ho;Mun, Sun-Yeo;Hwang, Cheol-Hong;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.62-68
    • /
    • 2014
  • The high predictive performance of fire detector models is essentially required for the reliable design of evacuation safety using the fire modeling. The main objective of the present study is to measure input information in order to predict the accurate activation time of photoelectric smoke detector adopted in fire dynamics simulator (FDS) recognized a representative fire model. To end this, the fire detector evaluator (FDE) which could be measured the device properties of detector was used, and the input information of Heskestad and Cleary's models was obtained for a spot-type photoelectric smoke detector. In addition, the activation times of smoke detector predicted using default values into FDS and measured values in the present study were quantitatively compared. As a result, the Heskestad model could result in an inaccurate the activation time of photoelectric smoke detector compared to the Cleary model. In addition, there was a distinct difference between the default values used into FDS and the measured values in terms of device properties of smoke detector, and thus the activation time also showed a significant difference.

Measurement of the Device Properties of Fixed Temperature Heat Detectors for the Fire Modeling (화재모델링을 위한 정온식 열감지기의 장치물성 측정)

  • Park, Hee-Won;Cho, Jae-Ho;Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong;Kim, Sung-Chan;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.37-43
    • /
    • 2014
  • The high predictive performance of fire detector models is essentially needed to assure the reliability of fire and evacuation modeling in the process of Performance-Based fire safety Design (PBD). The main objective of the present study is to measure input information in order to predictive the accurate activation time of fixed temperature heat detectors adopted in Fire Dynamics Simulator (FDS) as a representative fire model. To end this, Fire Detector Evaluator (FDE) which could be measured the device properties of detector was used, and the spot-type fixed temperature heat detectors of two thermistor types and one bimetal type were considered as research objectors. Activation temperature and Response Time Index (RTI) of detectors required for the fire modeling were measured, and then the RTI was measured for ceiling jet flow and vertical jet flow in consideration of the install location of detectors. The results of fire modeling using measured device properties were compared and validated with the experimental results of full-scale compartment fires. It was confirmed that, in result, the numerically predicted activation time of detector showed reasonable agreement with the measured activation time.

A Study on the Relation between IRI and PrI (평탄성 지수 IRI와 PrI의 상관관계에 관한 연구)

  • Kim, Kook-Han;Lee, Byung-Duck;Choi, Go-Il;Yang, Sung-Cheol
    • International Journal of Highway Engineering
    • /
    • v.5 no.1 s.15
    • /
    • pp.11-18
    • /
    • 2003
  • Road roughness, as the key factor influencing not only drivers' ride quality and safety but also pavement deterioration, is one of the most important pavement performance indicator to be evaluated by users' subjective assessment. For this reason, a specific number of the pavement roughness has been adopted to monitor the condition of a road for pavement management systems and to evaluate the quality of newly constructed sections, however, none of the unified methodology was internationally accepted. In Korea highway network, road roughness has been used mainly to evaluate newly placed pavement by using 7.6m CP (California Profile meter) to calculate PrI (Profile Index). But this instrument is manually operated to measure road profiles by traffic closure and their interpretation depends on personal bias. Therefore, problems arisen from the manually operated instrument will be overcome by using the APL (Longitudinal Profile Analyzer) which can be operated in the speed of 80km per hour. A study was conducted to correlate the relation from both concrete and asphalt pavement between IRI (measured by APL) and PrI (measured by 7.6m CP). Test results showed that there was a good correlation between IRI and PrI.

  • PDF

A Study of Measurement on Airtightness and Air-Flow Performance of Apartment Housing Adopting Window Frame-Type Natural Ventilation (자연환기장치가 적용된 공동주택의 기밀 및 공기유동 성능 실측 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Kim, Sun-Dong
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.325-332
    • /
    • 2014
  • The purpose of this study was to measure the airtightness and Air-Flow Performance for 7th house of small apartment houses adopted window frame-type natural ventilation. All window and living room door is provide with window frame-type natural ventilation, and there is provide with manual controller. As the object of measurement, the 6th type small apartment houses with area of $33m^2$ to $51m^2$ was selected. airtightness performance was measured at the front door using Blower door system. We measured ventilation rate per hour on 50Pa pressure different between inside and outside by the 1st to 6th cases. As a result, when the natural ventilation frame was closed, average amounts are shown as the ventilation rate per hour were 2.27ACH (CASE1). and the result is similar to general apartment house (1.65~4.28ACH). When the natural ventilation frame was open, average amounts are shown as the ventilation rate per hour were 5.87ACH (CASE6). In addition, that's a 3.6ACH increased more than CASE1.

Reliability improvement of an ion-measuring system using FET sensor array (FET 센서 어레이를 이용한 이온 측정 시스템의 신뢰도 개선)

  • Choi, Jung-Tae;Lee, Seung-Hyup;Kim, Young-Jin;Lee, Young-Chul;Cho, Byung-Woog;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.341-346
    • /
    • 1999
  • In general cases, compared with glass electrode, FET type electrolyte sensors have many advantages. But the drift, memory effect and the poor reproducibility of the FET type electrolyte sensor cause the decrease of the reliability in the measurement system. To improve the reliability, an ion-measuring system using FET type electrolyte sensor array with 8 sensors has been developed. Developed system employed the electronic switchs to connect a signal detecting circuit with 8 sensor array and the system can measure ion concentration of 4 different type electrolyte($H^+$, $Na^+$, $K^+$, $Ca^{2+}$). The signal processing algorithm with insertion sorting method was adopted to enhance the reliability. We measured 3 different ion($H^+$, $Na^+$, $K^+$) to evaluate the performance of developed system. The results show that the designed signal processing algorithm can reduce the error range in comparison with a simple arithmetic mean and the developed system has a good reliability over the previous single channel sensor system.

  • PDF

Analysis and Evaluation on the Location of Gu-Office Facility using Geographic Information System : The case of Mapo Gu-Office in Seoul (GIS 기법을 이용한 구청사 입지분석 및 타당성 검토)

  • Huh, Jun;Jang, Hoon;Lee, Hyun-Suk
    • 한국지형공간정보학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.5-10
    • /
    • 2004
  • The purpose of this research is to measure a gravitational attraction about urban pulbic service facilities and to evaluate the location of public service facilities. It is important in that these facilities should provide more inexpensive and convenience public service to users. To do this, the GIS's spatial analysis and gravity model were used to analyze the efficiency of the public facilities. The gravity model was conducted as the main analysis method, and another model for this analysis was the discrete model. The gravity model is originally to anticipate migration flows, traffic flows and other types of movements so that this model compares the gravitational attraction between places. The discrete model is to find the optimal location and to evaluate a location of facility regarding urban areas as the combination of node and link. In this research, these two models were adopted to compare and analyze location of Mapo-Gu Office. The results of this research indicated that the locational evaluation of urban public service facilities discovered the appropriateness of those facilities, and the public facilities was necessary to displace to other site.

  • PDF