• Title/Summary/Keyword: adjacent cycles

Search Result 42, Processing Time 0.021 seconds

Crack mapping in RC members using distributed coaxial cable crack sensors: modeling and application

  • Greene, Gary Jr.;Belarbi, Abdeldjelil;Chen, Genda
    • Smart Structures and Systems
    • /
    • v.1 no.4
    • /
    • pp.385-404
    • /
    • 2005
  • The paper presents a model to calculate reinforcement strain using measured crack width in members under applied tension, flexure, and/or shear stress. Crack mapping using a new type of distributed coaxial cable sensors for health monitoring of large-scale civil engineering infrastructure was recently proposed and developed by the authors. This paper shows the results and performance of such sensors mounted on near surface of two flexural beams and a large scale reinforced concrete box girder that was subjected to cyclic combined shear and torsion. The main objectives of this health monitoring study was to correlate the sensor's response to strain in the member, and show that magnitude of the signal's reflection coefficient is related to increases in applied load, repeated cycles, cracking, and reinforcement yielding. The effect of multiple adjacent cracks, and signal loss was also investigated. The results shown in this paper are an important step in using the sensors for crack mapping and determining reinforcement strain for in-situ structures.

A High-efficiency Method to Suppress Transformer Core Imbalance in Digitally Controlled Phase-shifted Full-bridge Converter

  • Yu, Juzheng;Qian, Qinsong;Sun, Weifeng;Zhang, Taizhi;Lu, Shengli
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.823-831
    • /
    • 2016
  • A high-efficiency method is proposed to suppress magnetic core imbalance in phase-shifted full-bridge (PSFB) converters. Compared with conventional solutions, such as controlling peak current mode (PCM) or adding DC blocking capacitance, the proposed method has several advantages, such as lower power loss and smaller size, because the additional current sensor or blocking capacitor is removed. A time domain model of the secondary side is built to analyze the relationship between transformer core imbalance and cathode voltage of secondary side rectifiers. An approximate control algorithm is designed to achieve asymmetric phase control, which reduces the effects of imbalance. A 60 V/15 A prototype is built to verify the proposed method. Experimental results show that the numerical difference of primary side peak currents between two adjacent cycles is suppressed from 2 A to approximately 0 A. Meanwhile, compared with the PCM solution, the efficiency of the PSFB converter is slightly improved from 93% to 93.2%.

Phosphorus Cycle in Three Herb Plant Populations in the Basin of Mt. Geumoh (금오산 분지의 삼종 초본식물개체군의 인의 순경)

  • 류승원
    • Journal of Plant Biology
    • /
    • v.30 no.4
    • /
    • pp.299-309
    • /
    • 1987
  • The seasonal pattern and the annual magnitude of the internal (or biochemical) and plant-soil cycles of phophorus in adjacent three different herb plant populations-Helianthus tuberosus L., Artemisia princeps Pampan and Phalaris anundinacea L.-in an old field of the basin in the Mt. Geumoh were investigated. A lot of the phosphorus demand for the three populations was supplied by the withdrawal from below-ground organ in early growing period, by the absorption from soil in mid-growing period and by the withdrawal from stem in later growing period. But in the A. princeps and P. arundianacea populations, a great deal of phosphorus seemed to be absorbed prior to the first withdrawal. The annual amount of the phosphorus flowing throughthe internal cycle was about 59% of the total hosphorus flow on theorgan level in the H. tuberosus population, 41% in the A. princeps population and 32% in the P. arundinacea population, indicating that the tuber plant had the most developed internal cycle system. The annual amount of phosphorus which took part in the plant-soil cycle in the stand of the three populations was in the range of 4.49-5.65 gPm-2, corresponding to only 3-8% of the extractable phosphorus contained in the soil of 0-20 cm depth. The fact that the H. tuberosus population is higher in the extent fo internal cycle but smaller in the magnitude of plant-soil cycle and lower in the turnover rate of phsophorus than the other two populations suggests that the growth of H. tuberosus population may be less dependent on soil phosphorus availability than those of the other two populations.

  • PDF

The Life Cycle of Tour Destination Hot Spring in Korea (한국 온천관광목적지의 수명주기)

  • Cho, Sung-Ho;Lee, Kyung-Ja
    • Journal of the Korean association of regional geographers
    • /
    • v.4 no.2
    • /
    • pp.165-182
    • /
    • 1998
  • When tour site is being used by people for the destination of tour, it has a life, or it will lose its life as a tour site. Therefore this paper aims to, based on Butler's theory, has chosen 46 hot spring spots in Korea which are legally assigned and presently running, and tried to analyze the life cycles, the stage of dispositional characteristics, and visitors' favoritism, and to try to find activating method which is not decline. Out of 46 spots, 29 Places were found on the stage of development, which took high percentage, 4 were on the growing stage, 5 were on the mature stage, 5 were on the stagnation or decline stage and the rest 3 were on the stage of rejuvenation. Geographically, Korean hot springs were located on the plain or mountainous areas mostly, and less of them were on hills and coast lines. In water quality, most of places had simple water while the places with salt and sulfur contained water were marked low rate. The temperatures of hot spring water were variable between $25^{\circ}C{\sim}78^{\circ}C$, but the older hot springs were hotter than new ones. After observing the relationship between disposition characteristics and life cycles, the geographical locations and the matter of approach were found as majour influential factors to the life cycles of them. The type of mountainous areas were observed slow progress in life cycle, due to traffic problem, until the road expansion or pavement work were done. Meanwhile, the suburban ones adjacent to big cities were favored by hot spring tourists due to their easy approach and easy traffic. The new born hot springs with such conditions have shown the fast growth. As studied above, since the hot springs were supposed to be for recuperation and vacational, a hot spring with better recreational and accommodational facilities was more favored by tourists than the one with pretty interior decorations. It was because the tour purpose of people has been switched from single purpose to multi one. Thus, the suggestion for activating a declining hot spring and bringing people in them is to develop new and attractive tour resources, expanding the related area, maintaining good quality of water, developing a complex site for long-term tour, developed traffic routs, hot spring festivals, utilizing adjacent tour resources, preparing public water supply system, and assigning as special tour zone.

  • PDF

Design of a Pipelined Deblocking Filter with efficient memory management for high performance H.264 decoders (효율적인 메모리 관리 구조를 갖는 H.264용 고성능 디블록킹 필터 설계)

  • Yu, Yong-Hoon;Lee, Chan-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.1
    • /
    • pp.64-70
    • /
    • 2008
  • The H.264 standard is widely used due to the high compression rate and quality. The deblocking filter of the H.264 standard improves the quality of images by eliminating blocking artifacts of pictures, and it requires a lot of computation. We propose a new hardware architecture for the deblocking filter with pipelined architecture, 1-D filters which support both horizontal and vertical filtering and efficient memory management. Four memory blocks are configured for the efficient storage and access of the current macroblock and adjacent referenced sub-macroblocks, and the pixel data from the motion compensation unit can be transferred without waiting during the computation cycles of the deblocking filter. The number of computation cycles and the hardware area are reduced using the proposed architecture, and the performance of the H.264 decoder is improved. We design the deblocking filter using Verilog-HDL and implement using an FPGA. The designed deblocking filter can be used for decoding HD quality images at 77 MHz.

Properties of Fatigue Crack Initiation and Arrest in Structural Steel Under Acid Fog (산성안개 하의 구조용강에서 피로균열의 발생 및 정류특성)

  • Kim, Min-Geon;Kim, Jin-Hak;Kim, Myeong-Seop;Ji, Jeong-Geun;Gu, Eun-Hoe
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.2
    • /
    • pp.374-379
    • /
    • 2002
  • Corrosion fatigue tests were carried out to clarify the influence of acid fog as environmental factor on the fatigue strength of SM55C using rotary bending fatigue tester. The fatigue strength of acid fog specimen extremely decreased about 80% compared to that of distilled water specimen. In acid fog environment, a number of cracks commenced at corrosion pit and coalesced with the adjacent cracks during they propagate, and they formed a single non-propagating circumferential crack under the endurance stress of N=5$\times$10$\^$7/ cycles. Also, the depth of the crack is smaller than that of normal fatigue crack, so the crack has a veil small aspect ratio. The reason of this peculiar crack growth characteristics is that the crack opening-closure behaviors are hindered by corrosion products on the surface crack faces, and hence it is thinkable that the strong corrosion action like anodic dissolution for crack growth in depth direction is weaker compared with surface, resulting from faint pumping action of crack during loading-shedding processes.

Evaluation on the Sulfate Attack Resistance of Cement Mortars with Different Exposure Conditions (노출조건에 따른 시멘트 모르타르의 황산염침식 저항성 평가)

  • Lee, Seung Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6A
    • /
    • pp.427-435
    • /
    • 2012
  • In order to evaluate the effects of exposure conditions on the resistance to sulfate attack of normal and blended cement mortars, several mechanical characteristics of the mortars such as expansion, strength and bulk density were regularly monitored for 52 cycles under sodium sulfate attack. The mortar specimens were exposed to 3 different types of exposure conditions; 1) continuous full immersion(Exposure A), continuous half-immersion(Exposure B) and cyclic wetting-drying(Exposure C). Experimental results indicated that the maximum deterioration was noted in OPC mortar specimens subjected to Exposure B, showing the wide cracks in the portions where attacking solution is adjacent to air. Additionally, the beneficial effect of ground granulated blast-furnace slag and silica fume was clearly observed showing a superior resistance against sodium sulfate attack, because of its lower permeability and densified structure. Thus, it is suggested that when concrete made with normal cement is exposed to sulfate environment, proper considerations on the exposure conditions should be taken.

Experimental seismic behaviour of L-CFST column to H-beam connections

  • Zhang, Wang;Chen, Zhihua;Xiong, Qingqing;Zhou, Ting;Rong, Xian;Du, Yansheng
    • Steel and Composite Structures
    • /
    • v.26 no.6
    • /
    • pp.793-808
    • /
    • 2018
  • In this study, the seismic performance of the connections between L-shaped columns composed of concrete-filled steel tubes (L-CFST columns) and H-beams used in high-rise steel frame structures was investigated. Seven full-scale specimens were tested under quasi-static cyclic loading. The variables studied in the tests included the joint type, the axial compression ratio, the presence of concrete, the width-to-thickness ratio and the internal extension length of the side plates. The hysteretic response, strength degradation, stiffness degradation, ductility, plastic rotation capacity, energy dissipation capacity and the strain distribution were evaluated at different load cycles. The test results indicated that both the corner and exterior joint specimens failed due to local buckling and crack within the beam flange adjacent to the end of the side plates. However, the failure modes of the interior joint specimens primarily included local buckling and crack at the end plates and curved corners of the beam flange. A design method was proposed for the flexural capacity of the end plate connection in the interior joint. Good agreement was observed between the theoretical and test results of both the yield and ultimate flexural capacity of the end plate connection.

Serious Complications after Self-expandable Metallic Stent Insertion in a Patient with Malignant Lymphoma

  • Cho, Sung Bae;Cha, Seon Ah;Choi, Joon Young;Lee, Jong Min;Kang, Hyeon Hui;Moon, Hwa Sik;Kim, Sei Won;Yeo, Chang Dong;Lee, Sang Haak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.1
    • /
    • pp.31-35
    • /
    • 2015
  • An 18-year-old woman was evaluated for a chronic productive cough and dyspnea. She was subsequently diagnosed with mediastinal non-Hodgkin lymphoma (NHL). A covered self-expandable metallic stent (SEMS) was implanted to relieve narrowing in for both main bronchi. The NHL went into complete remission after six chemotherapy cycles, but atelectasis developed in the left lower lobe 18 months after SEMS insertion. The left main bronchus was completely occluded by granulation tissue. However, the right main bronchus and intermedius bronchus were patent. Granulation tissue was observed adjacent to the SEMS. The granulation tissue and the SEMS were excised, and a silicone stent was successfully implanted using a rigid bronchoscope. SEMS is advantageous owing to its easy implantation, but there are considerable potential complications such as severe reactive granulation, stent rupture, and ventilation failure in serious cases. Therefore, SEMS should be avoided whenever possible in patients with benign airway disease. This case highlights that SEMS implantation should be avoided even in malignant airway obstruction cases if the underlying malignancy is curable.

Freezing-Thawing Resistance of Fiber Reinforced Polymers in Strengthening RC Members (구조보강용 FRP 복합체의 동결용해 저항성 평가 연구)

  • You, Young-Chan;Choi, Ki-Sun;Kim, Keung-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.1
    • /
    • pp.182-189
    • /
    • 2010
  • The strengthening performance of FRPs(Fiber Reinforced Polymers) is directly affected by the environmental conditions such as freezing-thawing and moisture because FRPs are usually bonded on the concrete surface. It is, therefore, strongly required to evaluate a durability of bond between FRPs and concrete as well as FRP materials itself. The freezing-thawing resistance of FRPs is evaluated in this study with the variables of freezing-thawing conditions, types of FRP and freezing-thawing cycles. From the test results, it is found that tensile strength and pull-off strength of CFRP are not affected by the freezing-thawing. On the other hands, those of GFRP show a little degradation because of continuous water immersion during thawing process. But, cautions are needed on the bond durability between FRPs and concrete in case of continuous water supplying from adjacent to the concrete.