• Title/Summary/Keyword: adhesive thickness

Search Result 356, Processing Time 0.027 seconds

Fatigue Strength Evaluation of T-Peel Adhesive Joing for Light Weight Material (경량 재료의 T형 접합이음의 피로강도 평가)

  • Lee, K.Y.;Kong, B.S.;Choi, H.S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.166-173
    • /
    • 1998
  • The evaluation of joint fatigue strength of light weight materials for an electrical vehicle body has been performed through T-peel joint tests with the design parameters such as joint style, adherend type, adherend thickness, adhesive thickness, and various adhesives. Fatigue strength was evaluated through 5-Hz, tension-tension, load controlled test with the zero stress ratio. It was observed that the fatigue strength of the joint increases with the increase of the adherend thickness. With the increase of the adhesive thickness, however, the fatigue strength of the joint increases insignificantly. An aluminum-FRP adherend combination shows much higher fatigue strength than an aluminum-aluminum adherend combination. The results of fatigue tests were found to be consistent with those of static tests.

  • PDF

TENSILE BOND STRENGTH BETWEEN ELASTOMERIC IMPRESSION MATERIALS AND TRAY RESINS DEPENDING ON THE THICKNESS OF THE TRAY ADHESIVE

  • Kim, Tae-Won;Moon, Hong-Seok;Lee, Keun-Woo;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.6
    • /
    • pp.699-711
    • /
    • 2006
  • Statement of problem. Elastomeric impression materials have been widely used to obtain an accurate impression. However there have not been enough studies on the influence of the thickness of the tray adhesives on the bonding strength between the trays and the elastomeric impression materials. Purpose. In order to understand the relationship between the thickness of the tray adhesive and the tensile bond strength and to suggest the thickness at which the bonding strength is strongest, tensile bond strength related to the thickness of adhesives of 3 different elastomeric impression materials were tested. Materials and methods. 3 impression materials, $Permlastic^{(R)}$. Regular Set(Kerr Corp., Romulus, Michigan, U.S.A.), $Impregum^{TM}$ $Penta^{TM}$(3M ESPE, Seefeld, Germany), and Aquasil Ultra Monophase Regular Set Smart Wetting.(Dentsply Caulk, Milford, Delaware, U.S.A.), were used in this study, and tray adhesives from the same manufacturers of the impression materials were used, which were Rubber Base Adhesive, Polyether Adhesive, and Silfix, respectively. The tray specimens were prepared by autopolymerizing the tray material(Instant Tray Mix, Lang, Wheeling, Illinois, U.S.A.), and a PVC pipe was used to house the impression material. In group A, tray adhesives were applied in multiple thin layers of 1 to 5 and in group B, adhesives were applied only once, in the thickness equivalent to several applications. Lightness($L^*$) of the adhesion surface was measured with a spectrophotometer(CM-3500d, Konica Minolta, Sakai, Osaka, Japan). The tensile bond strength of the elastomeric impression material and the tray resin was measured with universal materials testing machines(Instron, Model 3366, Instron Corp, Nowood, Massachusetts, U.S.A.). A formula between the number of adhesive application layers and the lightness of the adhesion surface was deduced in group A, and the number of adhesive layers in group B was estimated by applying the lightness($L^*$) to the deduced formula. Results. 1. In group A, a statistically significant increase in tensile bond strength appeared when the number of application layers increased from 1 to 2 and from 4 to 5, and no significant difference was present between 2, 3, and 4 layers in Permlastic. In Impregum, the tensile bond strength was significantly increased when the number of adhesive layers increased from 1 to 3, but no significant difference after 3 layers. In Aquasil, the tensile bond strength significantly increased as the number of application layers increased up to 4 but showed no significant difference between 4 and 5. 2. In group B, the tensile bond strength was decreased when the thickness of the adhesive increased in Permlastic. Impregum showed an increased tensile bond strength when the thickness of the adhesive was increased. In Aquasil, the tensile bond strength increased as the number of adhesive application layers increased up to approximately 2.5 layers but it sharply decreased after approximately 4.5. Conclusion. From the study, the common idea that it is better to apply a thin and single coat of tray adhesive needs correction in more detailed ways, and instructions on some of the tray adhesives should be reconsidered since there were several cases in which the tensile bond strength increased according to the increase in the thickness of the adhesives.

Experimental Study on Evaluation of Bonding Strength of Adhesively Bonded Joints by Adhesive (접착제 접합 이음부 접합강도 평가에 대한 실험적 연구)

  • Kang, Ki-Yeob;Lee, Jae-Myung
    • Journal of Welding and Joining
    • /
    • v.30 no.6
    • /
    • pp.62-67
    • /
    • 2012
  • In this study, the bonding strengths of adhesively bonded joints are experimentally investigated. A series of lap-shear tests are conducted using single lap type adhesive joints. In order to analyse the joint fabrication factors that affected the bonding strength, the parametric tests are conducted with various thickness of adhesive, surface roughness and fillet of adhesive. In addition, for the comparative study with the welded joint, lap-shear tests using specimens with 2 welded sides and 4 welded sides are also carried out. The quantitative results of the strength analysis are summarized, and some proposals are made on setting up testing standards for adhesively bonded joints.

Effect of Several Exterior Adhesive Types on Dimensional Stability of Bamboo Oriented Particleboard

  • Iswanto, Apri Heri;Munthe, Rensus;Darwis, Atmawi;Azhar, Irawati;Susilowati, Arida;Prabuningrum, Dita Sari;Fatriasari, Widya
    • Korean Journal of Materials Research
    • /
    • v.29 no.5
    • /
    • pp.277-281
    • /
    • 2019
  • The objective of this research is to evaluate the effect of adhesive types on dimensional stability of bamboo-oriented particleboard. The materials used in this research are bamboo tali(Gigantochloa apus J.A & J.H. Schult. Kurz), UF/MDI(8, 10, 12 % level), and MF, MDI, and PF at 7 % level. Particle and adhesive are mixed using a blending machine; then, mat forming and hot pressing processes are performed using adhesive-suitable temperature and time references. MDI resin is set at $160^{\circ}C$ temperature for 5 minutes. PF resin and MF resin are pressed at $170^{\circ}C$ for 10 minutes, and $140^{\circ}C$ for 10 minutes, respectively, while UF/MDI sets at temperature of $140^{\circ}C$ for 10 minutes. The results show that particleboard using PF resin produces the lowest thickness swelling value. The particleboard using UF/MDI resin also produces good response for thickness swelling value. Interesting things happen in that UF/MDI adhesive produces a thickness swelling value better than that of MDI resin. FTIR analysis on particleboard bonded by UF/MDI resin combination shows the presence of carbonyl group C=O vibration on multi substitution of urea at wave number of around $1,700cm^{-1}$.

Wet adhesion and rubber friction in adhesive pads of insects

  • Federle, Walter
    • Journal of Adhesion and Interface
    • /
    • v.5 no.2
    • /
    • pp.31-42
    • /
    • 2004
  • Many animals possess on their legs adhesive pads, which have undergone evolutionary optimization to be able to attach to variable substrates and to control adhesive forces during locomotion. Insect adhesive pads are either relatively smooth or densely covered with specialized adhesive hairs. Theoretical models predict that adhesion can be increased by splitting the contact zone into many microscopic, elastic subunits, which provides a functional explanation for the widespread 'hairy' design. In many hairy and all smooth attachment systems, the adhesive contact is mediated by a thin film of liquid secretion between the cuticle and the substrate. By using interference reflection microscopy (IRM), the thickness and viscosity of the secretion film was estimated in Weaver ants (Oecophylla smaragdina). 'Footprint' droplets deposited on glass are hydrophobic and form low contact angles. IRM of insect pads in contact showed that the adhesive liquid is an emulsion consisting of hydrophilic, volatile droplets dispersed in a persistent, hydrophobic phase. I tested predictions derived from film thickness and viscosity by measuring friction forces of Weaver ants on a smooth substrate. The measured friction forces were much greater than expected assuming a homogenous film between the pad and the surface. The findings indicate that the rubbery pad cuticle directly interacts with the substrate. To achieve intimate contact between the cuticle and the surface, secretion must drain away, which may be facilitated by microfolds on the surface of smooth insect pads. I propose a combined wet adhesion/rubber friction model of insect surface attachment that explains both the presence of a significant static friction component and the velocity-dependence of sliding friction.

  • PDF

Spreadability observation of the denture adhesive by the amount of the water (수분함량에 따른 의치접착제의 확장성 관찰)

  • Kim, Jong-Moon;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.37 no.1
    • /
    • pp.17-21
    • /
    • 2015
  • Purpose: In this study, Spreadability of denture adhesive in accordance with the saturation level of saliva, respectively, by using the resin plate and the glass was measured thickness and Spreadability. Methods: Examine the spreadability of denture adhesive in accordance with the saturation level of saliva, respectively, by using the resin plate and the glass was measured thickness and Spreadability. Also, by measuring the adhesive strength according to the amount of saliva, and the edentulous patients using denture adhesive and dry mouth patients attempt to provide clinical information of the denture adhesive. Therefore, by using the relatively low shrinkage cold curing resin, after fabricating specimen of plate form, for 7 days, it was immersed in water. Results: For the control group only denture adhesive, an artificial saliva for the experimental group were injected in $0.1m{\ell}$, $0.2m{\ell}$ and $0.3m{\ell}$ of the denture adhesive on the surface, experimental results of the investigation of the 10 times the tensile bond strength of the specimens in each group was obtained the following results. Conclusion: As the time to pressure increase in the same amount of saliva was found that the amount coming out of the denture adhesive, as the amount of saliva in the same pressure increase coming out of many denture adhesives. And the greater the pressure came out a lot of denture adhesives. Spreadability in measuring saliva contact with $0.1m{\ell}$ and $2m{\ell}$ and $3m{\ell}$ group pressured the diameter of the circular was the denture adhesive is small when compared to the group without adding the pressure of 2kg and 3kg put the saliva. The size of the circle is the same amount of saliva denture adhesive spread more pressure showed a greater increase.

Microleakage and characteristics of resin-tooth tissues interface of a self-etch and an etch-and-rinse adhesive systems

  • Xuan Vinh Tran;Khanh Quang Tran
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.30.1-30.13
    • /
    • 2021
  • Objectives: This study was conducted to compare the microleakage and characteristics of the resin-tooth tissue interface between self-etch and etch-and-rinse adhesive systems after 48 hours and 3 months. Materials and Methods: 40 extracted premolar teeth were randomly divided into 2 groups: 1-step self-etch adhesive system - OptibondTM All-In-One, and 2-step etch-and-rinse adhesive system - AdperTM Single Bond 2. Both groups were subjected to 500 thermocycles (5℃-55℃) before scanning electron microscope (SEM) analysis or microleakage trial at 48-hour and 3-month time periods. Results: SEM images showed the hybrid layer thickness, diameter, and length of resin tags of the self-etch adhesive (0.42 ± 0.14 ㎛; 1.49 ± 0.45 ㎛; 16.35 ± 14.26 ㎛) were smaller than those of the etch-and-rinse adhesive (4.39 ± 1.52 ㎛; 3.49 ± 1 ㎛; 52.81 ± 35.81 ㎛). In dentin, the microleakage scores of the 2 adhesives were not different in both time periods (48 hours/3 months). However, the microleakage score of etch-and-rinse adhesive increased significantly after 3 months (0.8 ± 0.63 and 1.9 ± 0.88, p < 0.05). Conclusions: The self-etch adhesive exhibited better long-term sealing ability in dentin when compared to that of the etch-and-rinse adhesive. The greater hybrid layer thickness and dimensions of resin tags did not guarantee reliable, long-lasting sealing in the bonding area.

The Effect of Titanium Interlayer on the Adhesion Properties of TiN Coating (Titanium Interlayer가 TiN 박막의 밀착특성에 미치는 영향)

  • Kong, S.H.;Kim, H.W.;Shin, Y.S.;Kim, M.I.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.5 no.1
    • /
    • pp.1-12
    • /
    • 1992
  • In order to improve adhesive force of TiN film, we sputtered titanium as interlayer before TiN deposition by Plasma Enhanced Chemical Vapour Deposition. We observed changes of hardness and adhesion at a various thickness of titanium interlayer and also examined analysis. At the critical thickness of the titanium interlayer(about $0.2{\mu}$), adhesive force of TiN films were promoted mostly. But over the critical thickness, a marked reduction of adhesive force was showed, because of the internal stress of titanium interlayer. From AES analysis, the adhesion improvement of TiN films was mainly caused by nitrogen diffusion into titanium interlayer during TiN deposition process which relieved stress concentration at TiN coating-substrate interface.

  • PDF

Formulation and Evaluation of Transdermal Patch Containing Sibutramine

  • Subedi, Robhash Kusam;Jang, Jun-Ho;Kim, Jae-Il;Park, Young-Joon;Choi, Hoo-Kyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.1
    • /
    • pp.33-38
    • /
    • 2010
  • Sibutramine is a serotonin-norepinephrine reuptake inhibitor indicated for the management of obesity in conjunction with a reduced calorie diet. The oral administration of sibutramine is followed by its dose-related side effects. In this study, sibutramine was formulated into drug in adhesive (DIA) patches in an attempt to overcome these problems. The effects of different formulation variables including pressure-sensitive adhesive (PSA), loading amount of drug, thickness of matrix and enhancer on the skin permeation of the drug were evaluated using excised hairless mouse skin. In the acrylic adhesive with carboxyl functional group, low release of sibutramine was observed due to the strong interaction between carboxyl group of adhesive and amine group of sibutramine. The acrylic adhesive without functional group provided good adhesion force and allowed high drug loading. Changing drug load as well as thickness of the matrix was found to alter permeation rate. $Crovol^{(R)}$ PK40 and $Crovol^{(R)}$ A40, were found to be effective enhancers for sibutramine. The optimized patch contained 20% sibutramine, and 5% $Crovol^{(R)}$ A40 as permeation enhancer, in $80\;{\mu}m$ thick Duro-$Tak^{(R)}$ 87-9301 matrix.

Fire Resistance of High Strength Concrete followed by Thickness of Fireproof Plaster Board and Change of Adhesive Method (방화석고보드의 두께 및 접착방식 변화에 따른 고강도 콘크리트의 내화특성)

  • Jang, Ki-Hyun;Kim, Won-Ki;Jin, Hu-Lin;Lee, Jin-Woo;Yang, Seong-Hwan;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.67-71
    • /
    • 2008
  • The study analyzed on fire resistance of high strength concrete followed by thickness of fireproof plaster board and change of adhesive method. In spalling characteristics after fire resistance test, all four-side covering concretes were left out of testing screens. Thus, serious spalling was happened by exposing their internal reinforcing rods. in partial testing screens, spalling was happened till the internal concrete of main reinforcing rod. Only, temperature history didn't have special differences among changes of adhesive method. However, thickness of fireproof plaster board is very important. Namely, mock member reinforcing 25mm general adhesive + Bending was 583℃ in the highest temperature of surface part and 479℃ in the highest temperature of the main reinforcing rod, which was relatively good temperature history.

  • PDF