• Title/Summary/Keyword: adhesive layer

Search Result 542, Processing Time 0.027 seconds

Optimal Design of Curved Actuator through High Performance Computing (고성능 컴퓨팅을 이용한 곡면형 작동기의 최적 설계)

  • 정순완;김승조
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.04a
    • /
    • pp.87-90
    • /
    • 2003
  • In this paper, the electromechanical displacements of curved actuators such as THUNDER are calculated by finite element method to design the optimal configuration of curved actuators. To predict the pre-stress in the device due to the mismatch in coefficients of thermal expansion, the adhesive as well as metal and PZT ceramic is also numerically modeled by using hexahedral solid elements. Because the modeling of these thin layers causes the numbers of degree of freedom to increase, large-scale structural analyses are performed in a cluster system in this study. The curved shape and pre-stress in the actuator are obtained by the cured curvature analysis. The displacement under the piezoelectric force by an applied voltage is also calculated to compare the performance of curved actuator. The thickness of metal and adhesive, the number of metal layer are chosen as design factors.

  • PDF

Joint Design of Steel-Aluminum Power Steering Cylinder by using FE Analysis with Cohesive Zone Model (Cohesive Zone Model을 이용한 동력조향 유압실린더의 스틸-알루미늄 접착부 설계)

  • Lee, C.J.;Lee, S.K.;Ko, D.C.;Schafer, H.;Lee, J.M.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.18 no.5
    • /
    • pp.385-391
    • /
    • 2009
  • An adhesively bonded power steering cylinder with a steel tube and an aluminum bracket was developed to reduce the weight of steering systems. To achieve the joint strength between the steel tube and of the aluminum bracket, the shape aluminum bracket re-designed by using the FE-analysis. Fracture behavior of the adhesive layer was considered by a cohesive zone model(CZM), which is based on the two-parameter fracture phenomenon with critical stress and fracture toughness. From the result of FE-analysis with CZM, re-designed power steering cylinder satisfied the desired joint strength for axial and torsion modes. And its joint strength was verified by the fracture test in each mode.

Strength Evaluation of Adhesive Bonded Joint for Light Weight Structure by Single-Lab Joint Test (단면 겹치기 이음 시험에 의한 경량구조물용 접착 이음강도의 평가)

  • 이강용;김준범;최홍섭;우형표
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.2
    • /
    • pp.87-93
    • /
    • 1997
  • The bonding strength evaluation of light weight materials for electrical vehicle applications has been performed through single lap joint tests in which the design parameters such as fillet, joint style, adherend, bonding overlap length,bonding thickness, and environmental condition(soaking time in $25^{\circ}C$ water) are considered. It is experimentally oberved that lap shear strength of joint increases for higher fillet height, longer overlap length, and thinner bonding layer thickness. Al-Al adherend combination shows much higher lap shear strength than AL-FRP and FRP-FRP adherend combinations. Riveting at adhesive bonded joint of AL-AL adherend combination makes lap shear strength decrease. Effect of soaking time on lap shear strength is negligible.

  • PDF

Double layered Superconductor Wire using Electrophoresis (전기영동법을 이용한 2층 구조 초전도선재 제작)

  • Soh, Dea-Wha;Park, Jung-Cheol;Jeon, Yong-Woo;Li, Ying-Mei;Cho, Yong-Joon;Lim, Byung-Jae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.21-24
    • /
    • 2002
  • In this paper, for the study on the fabrication of YBCO superconductor wire, a double layered YBCO superconductor wire was fabricated by electrophoretic method on metal Ag wire(${\Psi}$0.8 mm). On the basis of previous researches for the fabrication of superconductor wire, the acetone suspension solution with 8 vol.% of 1% PEG(1000) was used and high molecular adhesive was experimentally performed for an improvement of the critical current density of superconductor wire. It was found that the Ag inter-layer deposited on the superconductor wire affect to the state of second YBCO film and its critical current density.

  • PDF

APPLICATIONS OF TWO-STATE M-INTEGRAL FOR ANALYSIS OF ADHESIVE LAP JOINTS (접착 LAP JOINT 해석을 위한 두 상태 M-적분의 응용)

  • 임세영;이용우
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1997.04a
    • /
    • pp.35-42
    • /
    • 1997
  • The two-state or mutual M-integral which is derived from tile M-integral and is applicable for two elastic states, is applied for computing all intensity of a singular near-tip field around the vertex of a class of wedge, encountered in adhesive lap joints under mechanical loading. Numerically we verify that a simple auxiliary field associated with every eigenfunction for the composite wedge under consideration exists in the form of the conjugate solution in the sense of tile M-integral. The auxiliary field is then employed for superposition with the elastic field under consideration, and the associated two-state M-integral is computed via the domain integral technique. This enables us to extract the intensity for a singular field information for a singular elastic boundary layer is extracted form the domain integral representation without resort to singular finite element for the wedge vertex.

  • PDF

Strengthening Performance and Failure Characteristics of Reinforced Concrete Beams Exposed to Freezing-and-thawing Cycles after Shear Strengthening with CFRP Plate (CFRP 판으로 전단 보강된 이후 동결융해에 노출된 철근콘크리트 보의 보강성능 및 파괴특성)

  • Yun, Hyun-Do;Kim, Sun-Woo;Jeon, Esther;Lee, Min-Jung
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.457-460
    • /
    • 2008
  • CFRP plates has been established as an effective method for rehabilitation and strengthening of concrete structures. The CFRP reinforcements are bonded to beams and slabs using structural adhesives. Adhesive strength can be affected by environmental exposure. During freezing-and-thawing cycling, temperature-induced stresses in the adhesive layer, due to differential thermal expansion between the CFRP and the substrate concrete, may lead to bond damage and contribute to or cause premature CFRP composite separation. This paper presents the results of experimental program undertaken to investigate the effects of freeze-thaw cycling (from -18 to $4^{\circ}C$) on the behavior and failure characteristics of RC beams strengthened in shear with CFRP plate using acoustic emission (AE) technique.

  • PDF

Influence of application time of self-etching primer on bonding to dentin

  • Song, Ki-Gang;Lee, Young-Gon;Cho, Young-Gon
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.625-625
    • /
    • 2003
  • I. Objectives Self-etching primer adhesive system is affected to dentin surface conditioning and priming. Especially application time of self-etching primer is very important factor of clinical procedure which has direct influence on smear layer, etching reaction and primer penetration to dentin. This study evaluated the influence of application time of self-etching primers on microtensile bond strength (${\mu}{\;}TBS$) to dentin using three self-etching primer adhesive systems.(omitted)

  • PDF

Adhesion Performance Change of Positive-side Installed Rubber Asphalt Waterproof Sheet Integrated with Water-Soluble Film in Accordance to Wetness Condition (수용성 필름이 일체화된 역타설 고무 아스팔트 방수시트의 콘크리트 타설시 가수 여부에 따른 부착성능 변화 연구)

  • An, Ki-Won;Kang, Hyo-Jin;Kim, Chun-Hag;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.229-230
    • /
    • 2019
  • Integrated water-soluble film is dissolved in the rubber asphalt waterproof sheet to secure adhesive strength on freshly cast concrete on the adhesion side of waterproofing layer on the floor slab. In addition, in order to determine whether the water in the concrete slurry can dissolve the water-soluble film sufficiently, the adhesive strength of the waterproofing sheet was compared between difference wetness condition at the upper part of the concrete specimen before the concrete casting.

  • PDF

Composite aluminum-slab RC beam bonded by a prestressed hybrid carbon-glass composite material

  • Rabahi Abderezak;Tahar Hassaine Daouadji;Bensatallah Tayeb
    • Structural Engineering and Mechanics
    • /
    • v.85 no.5
    • /
    • pp.573-592
    • /
    • 2023
  • This paper presents a careful theoretical investigation into interfacial stresses in composite aluminum-slab reinforced concrete beam bonded by a prestressed hybrid carbon-glass composite material. The model is based on equilibrium and deformations compatibility requirements in and all parts of the strengthened beam, i.e., the aluminum beam, the slab reinforced concrete, the hybrid carbon-glass composite plate and the adhesive layer. The theoretical predictions are compared with other existing solutions. Numerical results from the present analysis are presented both to demonstrate the advantages of the present solution over existing ones and to illustrate the main characteristics of interfacial stress distributions. It is shown that the stresses at the interface are influenced by the material and geometry parameters of the composite beam. This research is helpful for the understanding on mechanical behaviour of the interface and design of the hybrid structures.

Finite element analysis of corner cracked aluminum panels repaired with bonded composite patch

  • Abdelkader Boulenouar;Mohammed A. Bouchelarm;Noureddine Benseddiq
    • Steel and Composite Structures
    • /
    • v.49 no.3
    • /
    • pp.271-280
    • /
    • 2023
  • In this study, the three-dimensional finite element method is used to analyze the behavior of corner cracks in finite-thickness plates repaired with a composite patch. The normalized stress intensity factor at the crack front is used as fracture criterion. Comparison of stress intensity factor values at the internal and external positions of repaired quarter-elliptical corner crack was done, for three repair techniques. The influence of mechanical and geometrical properties of the adhesive layer and the composite patch on the variation of the stress intensity factor (SIF) at the crack-front was highlighted. The obtained results show that the application of double patch leads to a remarkable reduction of SIF at the crack front, compared to facial and lateral repairs.