• Title/Summary/Keyword: adhesion method

Search Result 1,097, Processing Time 0.033 seconds

Characteristics Correlations Between Fiber-Reinforced and Interfacial Adhesion in Carbon fiber reinforced Cement composite Prepared by Slurry Method. (슬러리법에 의한 탄소섬유보강 시멘트복합체의 제조에서 보강섬유와 계면결착제와의 상관특성)

  • Choi, Eung-Kyoo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.3
    • /
    • pp.131-138
    • /
    • 2002
  • The objective of the study is to examine the characteristic correlations between reinforcing carbon fiber and interfacial adhesion agent since the interfacial adhesion strength between reinforcing carbon fiber and matrices is believed to be an essential element influencing the physical properties in carbon fiber reinforced cement composite using slurry method. The integrity of interfacial adhesion between reinforcing fiber and cement not only affects the quality of fiber reinforced cement composite but also influences to a large degree the physical properties of the cement composite when producing carbon fiber reinforced cement composite using slurry method. Having analyzed the physical properties 1.e., water content, tensile strength, flexural strength and flexural toughness of carbon fiber reinforced cement composite specimens, C-PAM(cation polyacrylamide) was determined to be an optimum interfacial adhesion agent. The study has also demonstrated that interfacial adhesion strength varies largely on the content and type of the reinforcing fiber. Judging from magnified view of the tensile shear cross-section using VMS(video microscope system), interfacial adhesion strength between reinforcing fiber and matrices is affected by the type of interfacial adhesion agent. According to the result of the experiments, C-PAM was determined to be an ideal interfacial adhesion agent when using carbon fiber in producing carbon fiber reinforced cement composite with the optimum content of carbon fiber being established.

Four Point Bending Test for Adhesion Testing of Packaging Strictures: A Review

  • Mahan, Kenny;Han, Bongtae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.4
    • /
    • pp.33-39
    • /
    • 2014
  • To establish the reliability of a packaging structures, adhesion testing of key interfaces is a critical task. Due to the material mismatch, the interface may be prone to delamination failure due to conditions during the manufacturing of the product or just from the day-to-day use. To assess the reliability of the interface adhesion strength testing can be performed during the design phase of the product. One test method of interest is the four-point bending (4PB) adhesion strength test method. This test method has been implemented in a variety of situations to evaluate the adhesion strength of interfaces in bimaterial structures to the interfaces within thin film multilayer stacks. This article presents a review of the 4PB adhesion strength testing method and key implementations of the technique in regards to semiconductor packaging.

A Research on Suggestion of Proper Adhesion Strength about conjugation Method of outside Insulation. (외단열 고정 방법에 따른 적정 접착강도 제안에 관한 연구)

  • Park, Wan-Goo;An, Ki-Won;Park, Jin-Samg;Park, Ku-Byoung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.93-94
    • /
    • 2012
  • Recently outside insulation is applied on the building. Adhesion mortar and anchor are used fixing method of outside insulation. However, a research on proper Adhesion Strength is not performed. So outside insulation exfoliate from building in rainy with winds. Therefore, this research suggest proper adhesion strength about conjugation method of outside insulation. As a result, adhesion way using the adhesive mortar + anchor is best. And proper adhesion strength is over 1,065 N.

  • PDF

Development of Polymeric Layer for Enhancing The Adhesion of Nano-devices Fabricated by The Nanotransfer Molding Method

  • Lee, Gi-Seok;Seong, Myeong-Mo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.634-634
    • /
    • 2013
  • Transfer molding methods have a problem that weak adhesion between nanostructures and substrates. It is important to make various nano scale applications, also the stability of nanostructure on substrate is related with device performance. We studied an effect of poly 4-vinylphenol (PVP) as the polymeric adhesion layer between organic nanowires and a Si substrate when the nanowires are transferred by liquid-bridge-mediated nanotransfer molding method (LB-nTM). Their structural stability was examined by optical microscopy, scanning electron microscopy as multiple transfer molding and washing process. Field-effect transistors were fabricated with organic semiconductor nanowires on a polymeric adhesion layer and their electrical properties showed no significant difference as the one without the adhesion layer. As a result, adhesion layer can be used in the washing process and making multi-layer nano-scale patterns.

  • PDF

Evaluation of the Adhesion Strength of Metal Spray Coating System in Steel using High-frequency Arc Metal Spray Method (고주파 아크 금속용사기를 이용한 금속용사 코팅계의 부착강도 평가)

  • Choe, Hong-Bok;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.96-97
    • /
    • 2014
  • The purpose of this study is to analyze the adhesion strength of metal spray coating system in steel using high-frequency arc metal spray method. For the purpose the experimental factor such as surface roughness was selected at 3 levels. As a result of experiment, it appeared that high-frequency arc metal spray method had higher adhesion strength than existing metal spray method. Especially, Al-Mg showed the highest adhesion strength than other metals. In case of surface roughness, the higher roughness steel has, the higher adhesion strength appeared.

  • PDF

NUMERICAL SIMULATION OF FLOWS INDUCED BY WALL ADHESION (벽면흡착에 의해 야기되는 유동 수치해석)

  • Myong, H.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.2-5
    • /
    • 2011
  • This paper presents a numerical study on multiphase flows induced by wall adhesion The CSF(Continuum Surface Force} model is used for the calculation of the surface tension force and implemented in an in-house solution code(PowerCFD). The present method(code) employs an unstructured cell-centered method based on a conservative pressure-based finite-volume method with volume capturing method(CICSAM) in a volume of fluid(VOF) scheme for phase interface capturing As an application of the present method, the effects of wall adhesion are numerically simulated with the CSF model for a shallow pool of water located at the bottom of a cylindrical tank. Two different cases are computed, one in which the water wets the wall and one in which the water does not wet the wall. It is found that the present method simulates efficiently and accurately surface tension-dominant multiphase flows induced by wall adhesion.

  • PDF

Fabrication and application of post surgical anti-adhesion barrier using bio-compatible materials (생체 적합성 재료를 이용한 수술후 유착 방지막의 제작과 응용)

  • Park S.H.;Kim H.C.;Yang D.Y.;Kim T.K.;Park T.K.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.203-204
    • /
    • 2006
  • Studies on some biodegradable polymers and other materials such as hydrogels have shown the promising potential for a variety of surgical applications. Postoperative adhesion caused by the natural consequence of surgical wound healing results in problems of the repeated surgery. Recently, scientists have developed absorbable anti-adhesion barriers that can protect a tissue from adhesion in case they are in use; however, they are dissolved when no longer needed. Although these approaches have been attempted to fulfill the criteria for adhesion prevention, none can perfectly prevent adhesions in all situations. Overall of this work, a new method to fabricate an anti-adhesion membrane using biodegradable polymer and hydrogel has been developed. The ideal barrier for preventing postoperative adhesion would have the following properties; it should be (i) resorbable (ii) non-reactive (iii) easy to apply (iv) capable of being fixed in position. In order to fulfill these properties, we adopted solid freeform fabrication method combined with surface modification which includes the hydrogel coating, therefore, inner or outer structure can be controlled and the property of anti adhesion can be improved.

  • PDF

The Effects of Surface Energy and Roughness on Adhesion Force (표면에너지와 거칠기가 응착력에 미치는 영향)

  • Rha, Jong-Joo;Kwon, Sik-Cheol;Jeong, Yong-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.11 s.254
    • /
    • pp.1335-1347
    • /
    • 2006
  • Surface energies calculated from measured contact angles between several solutions and test samples, such as Si wafer, $Al_2O_3$, $SiO_2$, PTFE(Polytertrafluoroethylene), and DLC(Diamond Like Carbon) films, based on geometric mean method and Lewis acid base method. In order to relate roughness to adhesion force, surface roughness of test samples were scanned large area and small by AFM(Atomic Force Microscopy). Roughness was representative of test samples in large scan area and comparable with AFM tip radius in small scan area. Adhesion forces between AFM tip and test samples were matched well with order of roughness rather then surface energy. When AFM tips having different radius were used to measure adhesion force on DLCI film, sharper AFM tip was, smaller adhesion force was measured. Therefore contact area was more important factor to determine adhesion force.

Hybrid Re-Adhesion Control Method for Traction System of High-Speed Railways with Parallel Induction Motor Control (유도전동기 병렬 제어형 고속전철 추진시스템의 혼합형 재점착 제어기법)

  • Hwang, Don-Ha;Kim, Mun-Seop;Ryu, Hong-Je;Park, Do-Yeong;Kim, Jong-Su
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.1
    • /
    • pp.40-47
    • /
    • 2002
  • This paper describes a re-adhesion control method for the Korean High-Speed Train (KHST) with parallel induction motor drive. To keep a traction efficiency and to improve vehicle maintenance, the adhesion characteristics between wheel and rail are analyzed. Also the re-adhesion controller is designed as the subsystem of induction motor vector control. In order to verify performance of the proposed control techniques, the simulation is executed by train model and a downscaled re-adhesion control simulator is utilized. Both simulation and running test results show that good re-adhesion characteristics are obtained.

Tongue-Lip Adhesion Using an Alveolar Protector Appliance for Management of Pierre Robin Sequence (피에르 로빈 연속증의 치료로써 치조 보호 장치를 이용한 혀-하순 유착술)

  • Lee, Jang-Won;Park, Beyoung-Yun
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.547-551
    • /
    • 2011
  • Purpose: Pierre Robin sequence is a congenital malformation in which micrognathia causes glossoptosis and airway obstruction. If conservative treatment fails, surgical procedures such as tongue-lip adhesion can be performed. However, this procedure remains a subject of debate, with favorable results being countered by reports of complications. To overcome the above limitations, we revised the traditional method of tongue-lip adhesion using an alveolar protector. Methods: Between 1992 and 2011, a total of eight patients were identified with Pierre Robin sequence and were treated with tongue-lip adhesion. Two of these eight tongue-lip adhesion procedures were performed with an alveolar protector. The operative technique for tongue-lip adhesion was similar to that described in other published reports. The alveolar protector was inserted between the ventral surface of the tip of the tongue and the lower labial sulcus. Results: Tongue-lip adhesion failed in two patients because of wound dehiscence. The primary surgical success rate was 66.7%. In the two tongue-lip adhesion procedures performed with the alveolar protector, we observed no postoperative complications. Conclusion: Resistance to traction of the tongue can be encountered with nonunionized symphysis menti, causing loosening of the traction suture through the symphysis menti. This can lead to backward positioning of tongue, resulting in dehiscence of tongue lip adhesion. The alveolar protector is a good adjunct to tongue-lip adhesion because this method avoids postoperative loosening of the traction suture and wound dehiscence. It is a simple and effective auxiliary method that yields functional improvement.