• Title/Summary/Keyword: additional therapy

Search Result 752, Processing Time 0.043 seconds

Cancinoma of Uterine Cervix Treated wvith High Dose Rate Intracavitary Irradiation : 1 Patterns of Failure (자궁경부암의 고선량율 강내치료후 실패양상에 대한 고찰)

  • Kim Ok Bae;Choi Tee Jin;Kim Jin Hee;Lee Ho Jun;Kim Yung Ae;Suh Young Wook;Lee Tae Sung;Cha Soon Do
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.369-376
    • /
    • 1993
  • 226 patients with carcinoma of the uterine cervix treated with curative radiation therapy at the Department of Therapeutic Radiology, Dongsan hospital, Keimyung university, School of medicine, from July,1988 to May,1991 were evaluated. The patients with all stages of the disease were included in this study. The maximum and mean follow up durations were 60 and 43 months. The radiation therapy consisted of external irradiation to the whole pelvis (2700~4500 cGy) and boost parametrial doses (for a total of 4500~6300 cGy)with midline shild $(4{\times}10\;cm),$ and combined with intracavitary irradiation (5700~7500 cGy to point A). The distribution of patients according to the stage was as follows: stage IB 37 $(16.4\%),$ stage IIA 91 $(40.3\%),$ stage IIB 58 $(25.7\%),$ stage III 32 $(13.8\%),$ stage IV 8 $(3.5\%).$ The overall failure rate was $23.9\%$ (54 patients). The failure rate increased as a function of stage from $13.5\%$ in stage IB to $15.4\%$ in stage IIA, $25.9\%$ in stage IIB, $46.9\%$ in stage III, and $62.5\%$ in stage UV. The pelvic failure alone were 32 patients and 11 patients were as a components of other failure, and remaining 11 patients had distant metastasis only. Among the 43 patients of locoregional failure,28 patients were not controlled initially and in other words nearly half of total failures were due to residual tumor. The mean medial paracervical (point A) doses were 6700 cGy in stage IIB,7200 cGy in stage IIA,7450 cGy in stage IIB,7600 cGy in stage III and 8100 cGy in stage IV. The medial paracervical doses showed some correlation with tumor control rate in early stage of disease (stage Ib, IIA), but there were higher central failure rate in advanced stage in spite of higher paracervical doses. In advanced stage, failure were not reduced by simple increment of paracervical doses. To improve a locoregional control rate in advanced stages, it is necessary to give additional treatment such as concomitant chemoradiation.

  • PDF

Partial transmission block production for real efficient method of block and MLC (Partial transmission block 제작 시 real block과 MLC를 이용한 방법 중 효율적인 방법에 대한 고찰)

  • Choi JiMin;Park JuYoung;Ju SangGyu;Ahn JongHo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.19-24
    • /
    • 2004
  • Introduction : The Vaginal, the urethra, the vulva and anal cancer avoid the many dose to femur head and the additional treatment is necessary in inguinal LN. The partial transmission block to use inguinal LN addition there is to a method which it treats and produce partial transmission block a method and the MLC which to it analyzes. Material & Methode : The Inguinal the LN treatment patient partial transmission it used block and the MLC in the object and with solid water phantom with the patient it reappeared the same depth. In order to analyze the error of the junction the EDR2 (Extended dose range, the Kodak and the U.S) it used the Film and it got film scanner it got the beam profile. The partial transmission block and the MLC bias characteristic, accuracy and stability of production for, it shared at hour and comparison it analyzed. Result : The partial the transmission block compares in the MLC and the block production is difficult and production hour also above 1 hours. The custom the block the place where it revises the error of the junction is a difficult problem. If use of the MLC the fabrication will be break and only the periodical calibration of the MLC it will do and it will be able to use easily. Conclusion : The Inguinal there is to LN treatment and partial transmission block and the MLC there is efficiency of each one but there is a place where the junction of block for partial transmission block the production hour is caught long and it fixes and a point where the control of the block is difficult. like this problem it transfers with the MLC and if it treats, it means the effective treatment will be possible.

  • PDF

Efficacy of Small Bowel Displacement System in Post-Operative Pelvic Radiation Therapy of Rectal Cancer (소장 용적 측정을 통한 직장암의 수술 후 방사선치료 시 사용하는 소장 전위 장치(Small Bowel Displacement System : SBDS) 의 효용성 검토)

  • Ahn Yong Chan;Lim Do Hoon;Kim Moon Kyung;Wu Hong Gyun;Kim Dae Yong;Huh Seung Jae
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.63-69
    • /
    • 1998
  • Purpose : This study is to evaluate the efficacy of small bowel displacement system(SBDS) in post-operative pelvic radiation therapy(RT) of rectal cancer patients by measurement of small bowel volume included in the radiation fields receiving therapeutic dose. Materials and Method : Ten consecutive new rectal cancer patients referred to the department of Radiation Oncology of Samsung Medical Center in May of 1997 were included in this study. All patients were asked to drink $Castrographin^(R)$ before simulation and were laid prone for conventional simulation and CT scans with and without SBDS. The volume of opacified small bowel on CT scans, which was to be included in the radiation fields receiving therapeutic dose, was measured using Picture archiving and communication system (PACS). Results : The average small bowel volumes with and without SBDS were 176.0ml(5.2-415.6ml) and 185.1ml(54.5-434.2ml), respectively The changes of small bowel volume with SBDS compared to those without SBDS were more than $10\%$ decrease in three, less than 10% decrease in two, less than $10\%$ increase in three, and more than $10\%$ increase in two patients. Conclusion : No significant advantage of using SBDS in post-operative pelvic RT for rectal cancer patients has been shown by small bowel volume measurement using CT scan considering additional effort and time needed for simulation and treatment setup.

  • PDF

Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study (동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발)

  • Lee Suk;Lee Sang Hoon;Shin Dongho;Yang Dae Sik;Choi Myung Sun;Kim Chul Yong
    • Radiation Oncology Journal
    • /
    • v.22 no.4
    • /
    • pp.316-324
    • /
    • 2004
  • Purpose : In radiotherapy of tumors in liver, enough planning target volume (PTV) margins are necessary to compensate breathing-related movement of tumor volumes. To overcome the problems, this study aims to obtain patients' body movements by using a moving phantom and an ultrasonic sensor, and to develop respiration sating techniques that can adjust patients' beds by using reversed values of the data obtained. Materials and Methods : The phantom made to measure patients' body movements is composed of a microprocessor (BS II, 20 MHz, 8K Byte), a sensor (Ultra-Sonic, range $3\~3$ m), host computer (RS232C) and stepping motor (torque 2.3 Kg) etc., and the program to control and operate it was developed. The program allows the phantom to move within the maximum range of 2 cm, its movements and corrections to take place In order, and x, y and z to move successively. After the moving phantom was adjusted by entering random movement data (three dimensional data form with distance of 2 cm), and the phantom movements were acquired using the ultra sonic sensor, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using guinea pigs, the real-time respiration gating techniques were drawn by operating the phantom with the reversed values of the data. Results : The result of analyzing the acquisition-correction delay time the three types of data values and about each value separately shows that the data values coincided with one another within $1\%$ and that the acquisition-correction delay time was obtained real-time $(2.34{\times}10^{-4}sec)$. Conclusion : This study successfully confirms the clinic application possibility of respiration gating techniques by using a moving phantom and an ultrasonic sensor. With ongoing development of additional analysis system, which can be used in real-time set-up reproducibility analysis, it may be beneficially used in radiotherapy of moving tumors.

A Study of Reliability and Validity on the Korean Version of Social Adaptation Self Rating Scale(SASS) (한국어판 사회적응자기평가척도(SASS)의 신뢰도 및 타당도 연구)

  • Kim, Hyeong-Seob;Kim, Yong-Ku;Yoon, Choong-Han;Jeong, Han-Yong;Cheong, Young-Ki
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.8 no.2
    • /
    • pp.212-227
    • /
    • 2000
  • This study was designed to testify the reliability and validation on the Korean version of the Social Adaptation Self-rating Scale(SASS) which was developed from Bose et al. for the evaluation of social motivation and behavior of depressed patients in 1997. Interests for the social world, those of social functioning, of patients were involved in the addition of new measure of disturbance. And those were distinct from abnormalities of thought, mood and symptoms of patients with major depression. As the previous reports there were several evidences that treatments may be less likely to be effective if the system they act on is dysfunctional. Thus, a better social situation favoured better outcome. As a matter of fact, however, those reports were developed in the course of the evaluation of interpersonal therapy(IPT) and cognitive therapy. Accordingly the conversed question -whether pharmacological therapy with antidepressants can impact on social functioning in addition to addressing the core features of illness- has been addressed. To date, anyhow, it is accepted that enhancement of social functioning may be a therapeutic principle in its own right and illness rarely divorced from social context. In terms of those concepts the introduction of an assessment of social functioning into pharmacotherapeutic studies of depression has been welcomed and might be a potent instrument for evaluating the relative pharmacoeconomic benefits of different treatments. Despite of many scales which were applied for the evaluation of symptoms in the patients with depression, however, the scale for the evaluation of social functiong has not been introduced in Korea yet. Thus, this study was designed to introduce the concepts of social functioning in the patients with depression and to testify the reliability and validation on Korean version of SASS. This Korean version of SASS was submitted to a reliability and validation procedure based on the data from healthy general population survey in 291 individuals and 40 patients with major depression. Cronbach a was 0.790 in total subjects group and the correlation of test-retest was statistically significant(y=0.653, p<0.0l). Thus, the Korean version of SASS might be shown to be valid and reliable. The results of multivariate analyses allowed the identification of 3 principle factors(factor 1 = intersts in social activities, factor 2 = active interpersonal relationship, factor 3 = selfesteem) in normal group, however, it could be counted as only one factor in the depression group because nearly total items of SASS were involved in factor 1. In the view of these results, the Korean version of SASS may be useful additional tool for the evaluation of social functioning in depression.

  • PDF

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF

The Effect of Nasal BiPAP Ventilation in Acute Exacerbation of Chronic Obstructive Airway Disease (만성 기도폐쇄환자에서 급성 호흡 부전시 BiPAP 환기법의 치료 효과)

  • Cho, Young-Bok;Kim, Ki-Beom;Lee, Hak-Jun;Chung, Jin-Hong;Lee, Kwan-Ho;Lee, Hyun-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.190-200
    • /
    • 1996
  • Background : Mechanical ventilation constitutes the last therapeutic method for acute respiratory failure when oxygen therapy and medical treatment fail to improve the respiratory status of the patient. This invasive ventilation, classically administered by endotracheal intubation or by tracheostomy, is associated with significant mortality and morbidity. Consequently, any less invasive method able to avoid the use of endotracheal ventilation would appear to be useful in high risk patient. Over recent years, the efficacy of nasal mask ventilation has been demonstrated in the treatment of chronic restrictive respiratory failure, particularly in patients with neuromuscular diseases. More recently, this method has been successfully used in the treatment of acute respiratory failure due to parenchymal disease. Method : We assessed the efficacy of Bilevel positive airway pressure(BiPAP) in the treatment of acute exacerbation of chronic obstructive pulmonary disease(COPD). This study prospectively evaluated the clinical effectiveness of a treatment schedule with positive pressure ventilation via nasal mask(Respironics BiPAP device) in 22 patients with acute exacerbations of COPD. Eleven patients with acute exacerbations of COPD were treated with nasal pressure support ventilation delivered via a nasal ventilatory support system plus standard treatment for 3 consecutive days. An additional 11 control patients were treated only with standard treatment. The standard treatment consisted of medical and oxygen therapy. The nasal BiPAP was delivered by a pressure support ventilator in spontaneous timed mode and at an inspiratory positive airway pressure $6-8cmH_2O$ and an expiratory positive airway pressure $3-4cmH_2O$. Patients were evaluated with physical examination(respiratory rate), modified Borg scale and arterial blood gas before and after the acute therapeutic intervention. Results : Pretreatment and after 3 days of treatment, mean $PaO_2$ was 56.3mmHg and 79.1mmHg (p<0.05) in BiPAP group and 56.9mmHg and 70.2mmHg (p<0.05) in conventional treatment (CT) group and $PaCO_2$ was 63.9mmHg and 56.9mmHg (p<0.05) in BiPAP group and 53mmHg and 52.8mmHg in CT group respectively. pH was 7.36 and 7.41 (p<0.05) in BiPAP group and 7.37 and 7.38 in cr group respectively. Pretreatment and after treatment, mean respiratory rate was 28 and 23 beats/min in BiPAP group and 25 and 20 beats/min in CT group respectively. Borg scale was 7.6 and 4.7 in BiPAP group and 6.4 and 3.8 in CT group respectively. There were significant differences between the two groups in changes of mean $PaO_2$, $PaCO_2$ and pH respectively. Conclusion: We conclude that short-term nasal pressure-support ventilation delivered via nasal BiPAP in the treatment of acute exacerbation of COPD, is an efficient mode of assisted ventilation for improving blood gas values and dyspnea sensation and may reduce the need for endotracheal intubation with mechanical ventilation.

  • PDF

Evaluating efficiency of application the skin flash for left breast IMRT. (왼쪽 유방암 세기변조방사선 치료시 Skin Flash 적용에 대한 유용성 평가)

  • Lim, Kyoung Dal;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.49-63
    • /
    • 2018
  • Purpose : The purpose of this study is investigating the changes of treatment plan and comparing skin dose with or without the skin flash. To investigate optimal applications of the skin flash, the changes of skin dose of each plans by various thicknesses of skin flash were measured and analyzed also. Methods and Material : Anthropomorphic phantom was scanned by CT for this study. The 2 fields hybrid IMRT and the 6 fields static IMRT were generated from the Eclipse (ver. 13.7.16, Varian, USA) RTP system. Additional plans were generated from each IMRT plans by changing skin flash thickness to 0.5 cm, 1.0 cm, 1.5 cm, 2.0 cm and 2.5 cm. MU and maximum doses were measured also. The treatment equipment was 6MV of VitalBeam (Varian Medical System, USA). Measuring device was a metal oxide semiconductor field-effect transistor(MOSFET). Measuring points of skin doses are upper (1), middle (2) and lower (3) positions from center of the left breast of the phantom. Other points of skin doses, artificially moved to medial and lateral sides by 0.5 cm, were also measured. Results : The reference value of 2F-hIMRT was 206.7 cGy at 1, 186.7 cGy at 2, and 222 cGy at 3, and reference values of 6F-sIMRT were measured at 192 cGy at 1, 213 cGy at 2, and 215 cGy at 3. In comparison with these reference values, the first measurement point in 2F-hIMRT was 261.3 cGy with a skin flash 2.0 cm and 2.5 cm, and the highest dose difference was 26.1 %diff. and 5.6 %diff, respectively. The third measurement point was 245.3 cGy and 10.5 %diff at the skin flash 2.5 cm. In the 6F-sIMRT, the highest dose difference was observed at 216.3 cGy and 12.7 %diff. when applying the skin flash 2.0 cm for the first measurement point and the dose difference was the largest at the application point of 2.0 cm, not the skin flash 2.5 cm for each measurement point. In cases of medial 0.5 cm shift points of 2F-hIMRT and 6F-sIMRT without skin flash, the measured value was -75.2 %diff. and -70.1 %diff. at 2F, At -14.8, -12.5, and -21.0 %diff. at the 1st, 2nd and 3rd measurement points, respectively. Generally, both treatment plans showed an increase in total MU, maximum dose and %diff as skin flash thickness increased, except for some results. The difference of skin dose using 0.5 cm thickness of skin flash was lowest lesser than 20 % in every conditions. Conclusion : Minimizing the thickness of skin flash by 0.5 cm is considered most ideal because it makes it possible to keep down MUs and lowering maximum doses. In addition, It was found that MUs, maximum doses and differences of skin doses did not increase infinitely as skin flash thickness increase by. If the error margin caused by PTV or other factors is lesser than 1.0 cm, It is considered that there will be many advantages in with the skin flash technique comparing without it.

  • PDF

Relationships between the Change in Obesity Rate and Risk Factors of Metabolic Syndrome among Middle School Students in Ulsan (중학생의 비만율 변화 및 대사증후군 발생 위험요소와의 상관관계)

  • Choi, Soon-Ho;Shin, Song-Woo;Yoo, Cheol-In
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5271-5283
    • /
    • 2012
  • The purpose of this study was to provide fundamental materials for improving school health promotion programs by investigating the relationships between the change in obesity rate and risk factors of metabolic syndrome among middle school students in Ulsan. We analyzed the routine health check-up data in 58,298 2nd-year middle school students in Ulsan, which conducted by the Planned Population Federation of Korea from 2007 to 2011. The overall and girls obesity rates gradually decreased throughout the first four years but increased again in 2011. The boys obesity rates were highest in 2008 and lowest in 2010. Throughout the research years, the incidence rates of over-weight and obesity were statistically significantly higher in boys compared to girls(P<0.05). Prevalence rates of the metabolic syndrome, assessed with the modified Cook criteria except high blood pressure, were 0.58%, 0%, 0.01%, 0.31% and 4.53%, respectively in total, low, normal, over-weight, and obese groups. It indicates that the prevalence of metabolic syndrome is increasing and directly related to the obesity rate among adolescents. Hypertriglyceridemia was the most common component (36.58%) of the metabolic syndrome among the middles school students followed by low HDL cholesterol (6.47%), abdominal obesity (3.72%), and high blood sugar (0.47%). Prevalence of the various components of the metabolic syndrome were significantly higher in the obese group compared to other groups. In this study we observed the decrease in obesity rates between 2007 and 2010, and developing obesity prevention programs is essential in order to maintain the trend. Additional study should be necessary to find the cause of increase of obesity rate in 2011 and so to create more effective school health promotion programmes.

The Chewing Efficiency of Occlusal Stabilization Appliances by Anatomy of the Occlusal Surface (교합안정장치 교합면의 모양에 따른 저작효율)

  • Im, Yeong-Gwan;Choi, Choong-Ho;Kim, Jae-Hyeong;Rhee, Chong-Ouk;Kim, Byung-Gook
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.3
    • /
    • pp.361-373
    • /
    • 2005
  • Occlusal appliance therapy has been proven to be very useful and effective in reducing signs and symptoms of patients with TMD. However, there are no reports about the masticatory efficiency of the occlusal appliance. The purpose of this study was, first, to investigate the masticatory efficiency of the conventional stabilization appliance experimentally in normal healthy subjects, by comparing it with that of their natural dentition; and, second, to develop a modified stabilization appliance as an attempt to increase masticatory efficiency. Eleven subjects (mean age 25.3 years, range from 23 to 33) participated in this study. Six were men and five were women. They were healthy and had complete or near―complete natural dentition, and did not present with signs or symptoms of TMD. Two kinds of occlusal appliances―the conventional flat maxillary stabilization appliance (i.e., FSA) and a modified maxillary stabilization appliance with additional anatomic structures on its occlusal surface (i.e., ASA)―were made for every subject. Subjects chewed peanuts that were selected as a food to test the three masticatory conditions of the natural dentition, the ASA, and the FSA. The number of chewing strokes was counted during each 1-minute chewing period. Chewed peanut boluses were recovered and their hardness was measured by texture analysis. Statistical tests were performed. The following results were obtained. 1. The masticatory efficiency of the FSA was 38.6 percent that of the natural dentition. The efficiency of the ASA was 78.2 percent that of the natural dentition. 2. The number of chewing strokes in the natural dentition condition was measured to be 1.5 strokes per second. It decreased to 90 percent in the ASA and FSA conditions. These results indicate that the ASA could serve an improved masticatory capacity as well as its therapeutic effects in TMD. A clinical application of the ASA should be considered to extend the management of TMD patients.