• Title/Summary/Keyword: additional factor

Search Result 1,251, Processing Time 0.029 seconds

Analysis, Design, and Implementation of a Single-Phase Power-Factor Corrected AC-DC Zeta Converter with High Frequency Isolation

  • Singh, Bhim;Agrawal, Mahima;Dwivedi, Sanjeet
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.243-253
    • /
    • 2008
  • This paper deals with the analysis, design, and implementation of a single phase AC-DC Zeta converter with high frequency transformer isolation and power factor correction(PFC) in two modes of operation, discontinuous current mode of operation(DCM), and continuous current mode of operation(CCM). A Digital Signal Processor(DSP) based implementation is carried out for validation of the Zeta converter developed design in discontinuous mode of operation. A comparison of both modes of operation is presented for a 1kW power rating from the point of view of steady state and dynamic behavior, power quality, simplicity, control technique, device rating, and converter size. The experimental results of a developed prototype of Zeta converter are presented for validation of the developed design. It is observed that CCM is most suitable for higher power applications where it requires some complex control and sensing of the additional variables.

Single Stage PFC Flyback Converter Using Top Switch (Top 스위치를 이용한 단일 전력단 역률개선 플라이백 컨버터)

  • Lim Chang Seob;Kwon Soon Kurl;Lee Hyun Woo;Kim Eun Soo
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.669-672
    • /
    • 2001
  • Generally, previous converter is divided into two categories to get high power factor and good output regulation. These two categories can be combined a category with a main switch. These converter is called Single Stage PFC Converter. This approach has good electrical characteristics of high power factor and fast output voltage regulation. The cost and size are important factor to design the converter in low power system. Even single stage can reduce the size and cost, but this approach needs to have additional circuit like control, PWM circuit. To improve these demerits, Top switch is one of good choice In reduce and size in low power single stage converter. Because it has the ability of current limit, thermal protection, oscillator, control circuit as well as a main switch ability.

  • PDF

Torque Ripple Reduction Driver of Single Pulse High Power Factor (토크리플 저감을 고려한 단상 SRM 고역률 구동)

  • Kim, Bong-Chul;Park, Sung-Jun;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.979-981
    • /
    • 2003
  • A novel single-stage power factor corrected (PFC) drive for switched reluctance motor (SRM) is presented to achieve sinusoidal, near unity power factor input current. The proposed PFC SRM drive has no additional active switch. And a single-stage approach, which combines a DC link capacitor used as do source and a drive used for driving the motor into one power stage, has a simple structure and low cost. The characteristics and validity of the proposed circuit will be discussed in depth through the experimental results.

  • PDF

Single-Phase SRM Driving Method for Power Factor Correction (단상 SRM의 역률 개선을 위한 구동방식)

  • Ahn Jin-Woo;Park Sung-Jun;Son Ick-Jin;Oh Seok-Gyu;Hwang Young-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.235-238
    • /
    • 2001
  • A novel single-stage power factor corrected (PFC) drive for switched reluctance motor (SRM) is presented to achieve sinusoidal, near unity power factor input current. The proposed PFC SRM drive has no additional active switch. And a single-stage approach, which combines a DC link capacitor used as dc source and a drive used for driving the motor into one power stage, has a simple structure and low cost. The characteristics and validity of the proposed circuit will be discussed in depth through the experimental results.

  • PDF

Design of New Induction Heating Power Supply for Forging Applications Using Current-Source PWM Converter and Inverter (전류원 PWM 컨버터 / 인버터를 이용한 새로운 단조용 유도가열 전원장치의 설계)

  • Choi, Seung-Soo;Lee, Chang-Woo;Kim, In-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1602-1610
    • /
    • 2018
  • Induction heating can convert electrical energy to thermal energy with high conversion efficiency and quick heating. Currently, a current source rectifier/inverter-fed parallel resonant circuit is widely used as an induction heating power supply for forging applications. However, the conventional induction heating power supplies composed of phase-controlled rectifier and SCR inverter have low efficiency and low power factor at input side, and require additional starting circuitry. So this paper proposes new induction heating power supply topologies for forging applications which have high power factor, high efficiency, and large output power. It also suggests detailed design guideline.

Propagation Delay Modeling and Implementation of DGPS beacon signal over the Spherical Earth

  • Yu, Dong-Hui;Weon, Sung-Hyun
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.4
    • /
    • pp.295-299
    • /
    • 2007
  • This paper presents the ASF(Additional Secondary Factor) modeling of DGPS beacon signal. In addition to DGPS's original purpose, the feasibility to utilize DGPS system for timing and navigation has been studied. For timing and navigation, the positioning system must know the accurate time delay of signal traveling from the transmitter to receiver. Then the delay can be used to compute the user position. The DGPS beacon signal transmits the data using medium frequency, which travels through the surface and cause the additional delay rather than the speed of light according to conductivities and elevations of the irregular terrain. We introduce the modeling of additional delay(ASF) and present the results of implementation. The similar approach is Locan-C. Loran-C has been widely used as the maritime location system and was enhanced to E-Loran(Enhanced Loran). E-Loran system uses the ASF estimation method and is able to provide the more precise location service. However there was rarely research on this area in Korea. Hence, we introduce the ASF and its estimation model. With the comparison of the same condition and data from the original Monteath model and ASF estimation data of Loran system respectively, we guarantee that the implementation is absolutely perfect. For further works, we're going to apply the ASF estimation model to Korean DGPS beacon system with the Korean terrain data.

A Study on the Needs for Managerial Service for Residents in Multi-family Housing (공동주택의 입주자관리서비스에 대한 필요도 - 거주자와 관리자의 견해를 중심으로 -)

  • Chae, Hye-Won;Lee, Kyung-Hee;Hong, Hyung-Ock
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2004.11a
    • /
    • pp.393-397
    • /
    • 2004
  • The purpose of this study was to analyze the needs for managerial service for residents in multi-family housing. For the survey and statistical analysis, the questionnaires from 484 residents and 84 housing managers of multi-family housing within the Seoul metropolitan area were used. The analytical methods adopted in this study were frequency, percentage, t-test, and factor analysis. The results of this study are as follow : (1) Basic services within a multi-family housing included management, minimum residential self governance, basic etiquette, and community program. And additional service were categorized by the health and entertainment program, the consumer service program, the residential life services, the information and financial services program, and the children's program. (2) The favorite needs of residents' additional services were the market news and information, the programs related health, the mail services, the health diagnosis service programs etc. But, housing managers' needs were the market news and information, and the flea market. As to the results analyzing the needs for additional service fir residents, it was found there were differences between residents and housing managers.

  • PDF

Dynamic analysis of wind-vehicle-bridge system considering additional moments of non-uniform winds by wind shielding effect of multi-limb tower

  • Xu Han;Huoyue Xiang;Xuli Chen;Yongle Li
    • Wind and Structures
    • /
    • v.36 no.1
    • /
    • pp.1-14
    • /
    • 2023
  • To evaluate the wind shielding effect of bridge towers with multiple limbs on high-speed trains, a wind tunnel test was conducted to investigate the aerodynamic characteristics of vehicles traversing multi-limb towers, which represented a combination of the steady aerodynamic coefficient of the vehicle-bridge system and wind environment around the tower. Subsequently, the analysis model of wind-vehicle-bridge (WVB) system considering the additional moments caused by lift and drag forces under nonuniform wind was proposed, and the reliability and accuracy of the proposed model of WVB system were verified using another model. Finally, the factors influencing the wind shielding effect of multi-limb towers were analyzed. The results indicate that the wind speed distributions along the span exhibit two sudden changes, and the wind speed generally decreases with increasing wind direction angle. The pitching and yawing accelerations of vehicles under nonuniform wind loads significantly increase due to the additional pitching and yawing moments. The sudden change values of the lateral and yawing accelerations caused by the wind shielding effect of multi-limb tower are 0.43 m/s2 and 0.11 rad/s2 within 0.4 s, respectively. The results indicate that the wind shielding effect of a multi-limb tower is the controlling factor in WVB systems.

Analysis of Pollutant Characteristics in Nakdong River using Confirmatory Factor Modeling (확인적 요인모형을 이용한 낙동강 유역의 오염특성 분석)

  • Kim, Mi-Ah;Kang, Taegu;Lee, Hyuk;Shin, Yuna;Kim, Kyunghyun
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.1
    • /
    • pp.84-93
    • /
    • 2012
  • The study was conducted to analyze the spatio-temporal changes in water quality of the major 36 sampling stations of Nakdong River, depending on each station, season using the 17 water quality variables from 2000 to 2010. The result was verified to interpret the characteristics of water quality variables in a more accurate manners. According to the Principal component analysis (PCA) and Exploratory factor analysis (EFA) results; the results of these analyses were identified 4 factors, Factor 1 (nutrients) included the concentrations of T-N, T-P, $NO_{3}-N$, $PO_{4}-P$, DTN, DTP for sampling station and season, Factor 2 (organic pollutants) included the concentrations of BOD, COD, Chl-a, Factor 3 (microbes) included the concentrations of F.Coli, T.Coli, and Factor 4 (others) included the concentrations of pH, DO. The results of a Cluster analysis indicated that Geumhogang 6 was the most contaminated site, while tributaries and most of the down stream sites of Nakdong River were mainly affected by each nutrients (Factor 1) and organic pollutants (Factor 2). The verification consequence of Confirmatory factor analysis (CFA) from Exploratory factor analysis (EFA) result can be summarized as follows: we could find additional relations between variables besides the structure from EFA, which we obtained through the second-order final modeling adopted in CFA. Nutrients had the biggest impact on water pollution for each sampling station and season. In particular, It was analyzed that P-series pollutant should be controlled during spring and winter and N-series pollutant should be controlled during summer and fall.

ASF Measurements on Maritime by the Signal of the Pohang Loran-C (9930M) (포항 로란-C (9930M) 신호를 이용한 ASF 해상측정)

  • Lee, Chang-Bok;Lee, Jong-Koo;Kim, Young-Jae;Hwang, Sang-Wook;Lee, Sang-Jeong;Yang, Sung-Hoon
    • Journal of Navigation and Port Research
    • /
    • v.35 no.8
    • /
    • pp.619-624
    • /
    • 2011
  • A significant factor limiting the ranging accuracy of Loran (Long Range Navigation) signal is the additional secondary factor (ASF) in the time of arrival (TOA) measurements. Precise ASF values are essential if Loran deliver the high absolute accuracies demanded for aircraft approach, maritime harbour entrance. We measured the absolute propagation delay between Pohang Loran signal and Loran receiver output signal by comparing with Cesium atomic clock. In this study we measured ASFs between Pohang 9930M station and the 12 measurement points in the Yeongil Bay by using the measurement technique of absolute time delay. The measurement points were spaced at interval of 3 km by 3 km. An E-field antenna and an H-field antenna were used to improve the accuracy of ASF measurements and a DGPS (Differential GPS) receiver was used for accurate positions. We have gotten the result that the measured ASFs were compared with the predicted ASFs through this measurement technique.