• Title/Summary/Keyword: adaptive relaying

Search Result 36, Processing Time 0.027 seconds

An Adaptive Relaying Algorithm on Utilities' Electrical Feeders for Improving the Reliable Operation of Wind Farm Interconnected with Utility Grid (계통 연계 풍력발전단지의 운전효율 향상을 위한 배전 계통의 적응형 보호 계전 알고리즘)

  • Jang, Sung-Il;Kim, Ji-Won;Choi, Don-Man;Kim, Kwang-Ho;Kim, Hyung-Rae
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.338-341
    • /
    • 2003
  • This paper proposes the adaptive relaying algorithm of protective devices applied in the neighboring distribution feeders for reliable and efficient operations of a wind farm interconnected with distribution networks by dedicated lines. Generally, it would be highly possible that the wind turbine generators are influenced by abnormal grid conditions such as disturbances occurring in the neighboring distribution feeders as well as the dedicated power line. The delayed operation time of protective devices for satisfying the coordination might overly expose the interconnected wind turbine generators to the fault and cause damage to them. In order to reduce the damages on the interconnected wind farm about the faults happening in distribution networks, this paper describes the proper delayed operation time of protective relay.

  • PDF

Distance Relaying Algorithm Based on An Adaptive Data Window Using Least Square Error Method (최소자승법을 이용한 적응형 데이터 윈도우의 거리계전 알고리즘)

  • Jeong, Ho-Seong;Choe, Sang-Yeol;Sin, Myeong-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.8
    • /
    • pp.371-378
    • /
    • 2002
  • This paper presents the rapid and accurate algorithm for fault detection and location estimation in the transmission line. This algorithm uses wavelet transform for fault detection and harmonics elimination and utilizes least square error method for fault impedance estimation. Wavelet transform decomposes fault signals into high frequence component Dl and low frequence component A3. The former is used for fault phase detection and fault types classification and the latter is used for harmonics elimination. After fault detection, an adaptive data window technique using LSE estimates fault impedance. It can find a optimal data window length and estimate fault impedance rapidly, because it changes the length according to the fault disturbance. To prove the performance of the algorithm, the authors test relaying signals obtained from EMTP simulation. Test results show that the proposed algorithm estimates fault location within a half cycle after fault irrelevant to fault types and various fault conditions.

A Study on the Improved Protective Relaying Algorithm Applied in the Linked System Interconnecting Wind Farm with the Utilities (풍력발전단지 연계 전용선로 보호계전방식의 향상에 대한 연구)

  • 장성일;김광호;권혁완;김대영;권혁진
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.12
    • /
    • pp.675-683
    • /
    • 2003
  • This paper describes the correction strategy of an overcurrent relay applied in the linked line for interconnecting wind farm with utility power networks in order to improve the capability of a fault detection. The fault current measured in a relaying point might vary according to the fault conditions. Generally, the current of the line to line fault or the line to ground fault in the linked line is much higher than the set value of protective relay due to the large fault level. However, when the high impedance fault occurs in the linked line, we can't detect it by conventional set value because its fault level may be lower than the generating capacity of wind farm. And, the protective relay with conventional set value may generate a trip signal for the insertion of wind turbine generators due to the large transient characteristics. In order to solve above problems and improve protective relaying algorithms applied in the linked line, we propose a new correction strategy of the protective relay in the linked line. The presented method can detect the high impedance fault which can't be detected by conventional relay set value and may prevent the mis-operation of protective relay caused by the insertion of wind farm.

Basic Structure for Hierarchical Adaptive Protection System (적응보호를 위한 계층적 시스템의 기본구조)

  • Lee, Seung-Jae;Kim, Ki-Hwa;Oh, Jung-Hwan;Lim, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.584-587
    • /
    • 1995
  • Recent development in the digital relay technology has introduced the adaptive relaying system which adopts the relays to the current operating states. This paper proposes the hierarchical digital protection system whose design has been based on 154 kV S/S. Applying the newest communication networking, the system provides the new protection capabilities improving the system reliability and speed.

  • PDF

An Adaptive Setting Method for the Overcurrent Relay of Distribution Feeders Considering the Interconnected Distributed Generations

  • Jang Sung-Il;Kim Kwang-Ho;Park Yong-Up;Choi Jung-Hwan;Kang Yong-Cheol;Kang Sang-Hee;Lee Seung-Jae;Oshida Hideharu;Park Jong-Keun
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.4
    • /
    • pp.357-365
    • /
    • 2005
  • This research investigates the influences of distributed generations (DG), which are interconnected to the bus by the dedicated lines, on the overcurrent relays (OCR) of the neighboring distribution feeders and also proposes a novel method to reduce the negative effects on the feeder protection. Due to the grid connected DG, the entire short-circuit capacity of the distribution networks increases, which may raise the current of the distribution feeder during normal operations as well as fault conditions. In particular, during the switching period for loop operation, the current level of the distribution feeder can be larger than the pickup value for the fault of the feeder's OCR, thereby causing the OCR to perform a mal-operation. This paper proposes the adaptive setting algorithm for the OCR of the distribution feeders having the neighboring dedicated feeders for the DG to prevent the mal-operations of the OCR under normal conditions. The proposed method changes the pickup value of the OCR by adapting the power output of the DG monitored at the relaying point in the distribution network. We tested the proposed method with the actual distribution network model of the Hoenggye substation at the Korea Electric Power Co., which is composed of five feeders supplying the power to network loads and two dedicated feeders for the wind turbine generators. The simulation results demonstrate that the proposed adaptive protection method could enhance the conventional OCR of the distribution feeders with the neighboring dedicated lines for the DG.

Subcarrier Allocation for Multiuser in Two-Way OFDMA Relay Networks using Decode-and-Forward Relaying (복호후재전송을 사용하는 양방향 OFDMA 중계 네트워크에서 다중사용자를 위한 부반송파 할당 기법)

  • Shin, Han-Mok;Lee, Jae-Hong
    • Journal of Broadcast Engineering
    • /
    • v.15 no.6
    • /
    • pp.783-790
    • /
    • 2010
  • A two-way relay network provide improved spectral efficiency compared with a conventional one-way relay network by using either superposition coding or network coding. OFDMA network provides imptoved performance by adaptive resource allocation. In this paper, we propose a adaptive subcarrier allocation for a multiuser two-way OFDMA relay network. In the proposed algorithm, subcarriers are allocated to the user-pairs and relays to maximize the achievable sum-rate over all user-pairs while satisfying the minimum rate requirement for each user-pair. Simulation results show that the proposed algorithm provides improved performance compared with the static and greedy algorithms.

Relaying Protocols and Delay Analysis for Buffer-aided Wireless Powered Cooperative Communication Networks

  • Zhan, Jun;Tang, Xiaohu;Chen, Qingchun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.8
    • /
    • pp.3542-3566
    • /
    • 2018
  • In this paper, we investigate a buffer-aided wireless powered cooperative communication network (WPCCN), in which the source and relay harvest the energy from a dedicated power beacon via wireless energy transfer, then the source transmits the data to the destination through the relay. Both the source and relay are equipped with an energy buffer to store the harvested energy in the energy transfer stage. In addition, the relay is equipped with a data buffer and can temporarily store the received information. Considering the buffer-aided WPCCN, we propose two buffer-aided relaying protocols, which named as the buffer-aided harvest-then-transmit (HtT) protocol and the buffer-aided joint mode selection and power allocation (JMSPA) protocol, respectively. For the buffer-aided HtT protocol, the time-averaged achievable rate is obtained in closed form. For the buffer-aided JMSPA protocol, the optimal adaptive mode selection scheme and power allocation scheme, which jointly maximize the time-averaged throughput of system, are obtained by employing the Lyapunov optimization theory. Furthermore, we drive the theoretical bounds on the time-averaged achievable rate and time-averaged delay, then present the throughput-delay tradeoff achieved by the joint JMSPA protocol. Simulation results validate the throughput performance gain of the proposed buffer-aided relaying protocols and verify the theoretical analysis.

A Bandwidth Adaptive Path Selection Scheme in IEEE 802.16 Relay Networks

  • Lee, Sung-Hee;Ko, Young-Bae
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.3
    • /
    • pp.477-493
    • /
    • 2011
  • The IEEE 802.16 mobile multi-hop relay (MMR) task group 'j' (TGj) has introduced the multi-hop relaying concept in the IEEE 802.16 Wireless MAN, wherein a relay station (RS) is employed to improve network coverage and capacity. Several RSs can be deployed between a base station and mobile stations, and configured to form a tree-like multi-hop topology. In such architecture, we consider the problem of a path selection through which the mobile station in and outside the coverage can communicate with the base station. In this paper, we propose a new path selection algorithm that ensures more efficient distribution of resources such as bandwidth among the relaying nodes for improving the overall performance of the network. Performance of our proposed scheme is compared with the path selection algorithms based on loss rate and the shortest path algorithm. Based on the simulation results using ns-2, we show our proposal significantly improves the performance on throughput, latency and bandwidth consumption.

Fault Detection Relaying for Transmission line Protection using ANFIS (적응형 퍼지 시스템에 의한 송전선로보호의 고장검출 계전기법)

  • 전병준
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.9 no.5
    • /
    • pp.538-544
    • /
    • 1999
  • In this paper, we propose a new fault detection algorithm for transmission line protection using ANFIS(Adaptive Network Fuzzy Inference System). The developed system consists of two subsystems: fault type classification, and fault location estimation. We use rms value, zero sequence component and positive sequence of current, and then using learning method of neural network, premise and consequent parameters are tuned properly. To prove the performance of the proposcd system, generated data by EMTP(Electr0- Magnetic Transient Program) sin~ulationi s used. It is shown that the proposed relaying classifies fault types accurately and advances fault location estimation.

  • PDF

Adaptive Distance Relaying Based on Sensitivity Factors (민감도지수를 기반한 적응형 거리계전방식)

  • Yuan, Han-Chuan;Lim, Seong-Il;Lee, Seung-Jae;Choi, Myeon-Song;Rim, Seong-Jeong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.60-61
    • /
    • 2006
  • An unwanted trip of backup distance relays often lead to a blackout. This paper presents investigation report on involvement of backup distance relays in the past blackouts and sensitivity-factor based algorithm to make a distinction between a fault and overload caused by line tripping. A preliminary idea to prevent deterioration of the situation due to unwanted trip of distance relays by utilizing the proposed algorithm is presented.

  • PDF