• Title/Summary/Keyword: actual thickness

Search Result 428, Processing Time 0.033 seconds

Deposition uniformity of 7 wt% YSZ as a thermal barrier coating with different configurational arrangement for turbine blade shape mock-up by electron beam physical vapor deposition (터빈블레이드 형상 mock-up의 기하학적 배치조건에 따른 전자빔 물리기상증착법으로 제조된 7 wt% YSZ 열차폐 코팅의 코팅 균일성)

  • Oh, Yoon-Suk;Chae, Jung-Min;Ryu, Ho-lim;Han, Yoon-Soo;An, Jong-Kee;Son, Myung-Sook;Kim, Hong-Kyu
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.6
    • /
    • pp.308-316
    • /
    • 2019
  • Electron beam physical vapor deposition (EBPVD) is a conventional method to fabricate thermal barrier coating (TBC) of high temperature airfoil engine parts, such as blade etc. for its high temperature structural stability from the nature of columnar growth behavior. For the high quality of TBC by EBPVD, the structural factors, such as growth behavior, thickness uniformity and so on, should be managed to obtain the coating which satisfied the required specifications of usable level of mechanical and thermal properties. In this study, the growth behavior and structure variations of 7YSZ (7 wt% yttria stabilized zirconia) coatings with different configurational deposition parameters for the specimens which have turbine blade shape mock-up were investigated. Growth behavior of coatings were studied by comparing computational modeling of evaporation behavior with actual deposition process using e-beam source.

Development of Designed Formulae for Predicting Ultimate Strength of the Perforated Stiffened Plate subjected to Axial Compressive Loading (압축하중을 받는 유공보강판 구조의 최종강도 설계식 개발)

  • Park, Joo-Shin;Ko, Jae-Yong;Lee, Kyung-Hwan
    • Journal of Navigation and Port Research
    • /
    • v.31 no.5 s.121
    • /
    • pp.435-445
    • /
    • 2007
  • Ship structures are thin-walled structures and lots of cutouts, for example, of inner bottom structure, girder, upper deck hatch, floor and dia-frame etc. In the case where a plate has cutout it experiences reduced buckling and ultimate strength and at the same time the in-plane stress under compressive load produced by hull girder bending will be redistributed. In the present paper, we investigated several kinds of perforated stiffened model from actual ship structure and series of elasto-plastic large deflection analyses were performed to investigate into the influence of perforation on the buckling and ultimate strength of the perforated stiffened plate varying the cutout ratio, web height, thickness and type of cross-section by commercial FEA program(ANSYS). Closed-form formulas for predicting the ultimate strength of the perforated stiffened plate are empirically derived by curve fitting based on the Finite Element Analysis results. These formulas are used to evaluate the ultimate strength, which showed good correlation with FEM results. These results will be useful for evaluating the ultimate strength of the perforated stiffened plate in the preliminary design.

A Study on Analysis of Installation on the Actual State and Improvement about a Descending Life Line (완강기의 설치 실태 분석 및 개선에 관한 연구)

  • Choi, Yong-Hyuk;Park, Sung-Jin;Kim, Tae-Gu;Kim, Kwang-Il
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.105-114
    • /
    • 2008
  • This study investigated problems found with the installation of a descending life line which is one of the compulsory fire escape apparatuses required by the revised "Fire Service Act" of 2006 for multi-use facilities and multistory buildings. It presents an analysis of the causes and improvement details for the problems classified by type of item. To achieve the purpose, the total 367 problem points are indicated. The problems of Installation are unsuitable window glass using the descending life line(34%), required passage device is not attached(23.7%), the installation location is with required operation(20%) and damaged descending life line(20%) were investigated. In particular, the study looks at the stress analysis range for cracking window glass which is required for people to escape in an emergency. People have questioned unsuitable window glass for using the descending life line among the problems with the installation. As a result of stress analysis, window glass thickness of the place where the descending life line is installed must be 3 or 6 mm. In addition, this study indicates substantial improvement measures for installing the descending life line so I will actually be used as a fire escape apparatus to protect human lives, and not just to formally meet the Fire Service Act.

Development of Intelligent Compaction System for Efficient Quality Control (효율적 품질관리를 위한 지능형 다짐 시스템 개발)

  • Lee, Soomin;Park, Sangil;Lee, Riho;Seo, Jongwon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.751-760
    • /
    • 2018
  • Currently, the quality measurement of the work is carried out by the supervisor's visual inspection, as the workers individually judge the number of resolutions, thickness, speed and vibration. After work, we are conducting follow-up work through traditional spot test, which is less representative. Therefore, it is impossible to check the results of the resolution, and there is always the possibility that problems will arise due to poor construction. This study demonstrates the feasibility of using the continuous compaction strength measurement method by comparing the continuous compaction strength measurement method and the conventional compaction strength measurement method after performing the compaction in the actual field scale in various test conditions. The validity is verified by analyzing the Compaction Meter Value of an Intelligent Compaction roller composed of a Global Positioning System and an accelerometer, Based on the proven results, a full range of quality can be confirmed without a single test. The quality confirmation is visualized in the compaction control program developed in this study, This enables the field manager to perform real-time quality monitoring at the same time as compaction.

A Study on the compensation margin on butt welding joint of large steel plates in shipyards (조선해양 구조물 주판의 Butt welding joint 수축에 관한 연구)

  • Kim, Jeongtae;Lee, Daechul;Jeong, Hyomin;Chung, Hanshik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.461-466
    • /
    • 2013
  • This paper examines the characteristics of butt welding joint shrinkage for shipbuilding and marine structures main plate. The shrinkage strain of butt welding joint which is caused by the process of heat input and cooling, results in the difference between dimensions of the actual parent metal and the dimensions of design. This, in turn, leads to poor quality in the production of ship blocks and reworking through period of correction brings about impediment on improvement of productivity. Through experiments on butt welding joint's shrinkage strain on large structures main plate, the deformation of welding residual stress in the form of I, Y, V was obtained. In addition, the results of experiments indicate that there is limited range of shrinkage in the range of 1 ~ 2 mm in 11t ~ 21.5t thickness and the effect of heat transfer of weld appears to be limited within 1000mm based on one side of seam line so there was limited impact of weight of parent metal on the shrinkage. Finally, it has been learned that Shrinkage margin needs to be applied differently based on groove phenomenon in the design phase in order to minimize shrinkage.

Cashew reject meal in diets of laying chickens: nutritional and economic suitability

  • Akande, Taiwo O;Akinwumi, Akinyinka O;Abegunde, Taye O
    • Journal of Animal Science and Technology
    • /
    • v.57 no.5
    • /
    • pp.17.1-17.6
    • /
    • 2015
  • The present study investigated the nutritional and economic suitability of cashew reject meal (full fat and defatted) as replacement for groundnut cake (GNC) in the diets of laying chickens. A total of eighty four brown shavers at 25 weeks of age were randomly allotted into seven dietary treatments each containing 6 replicates of 2 birds each. The seven diets prepared included diet 1, a control with GNC at $220gkg^{-1}$ as main protein source in the diet. Diets 2, 3 and 4 consist of gradual replacement of GNC with defatted cashew reject meal (DCRM) at 50%, 75% and 100% on weight for weight basis respectively while diets 5, 6 and 7 consist of gradual inclusion of full fat cashew reject meal (FCRM) to replace 25%, 35% and 50% of GNC protein respectively. Each group was allotted a diet in a completely randomized design in a study that lasted eight weeks during which records of the chemical constituent of the test ingredients, performance characteristics, egg quality traits and economic indicators were measured. Results showed that the crude protein were 22.10 and 35.4% for FCRM and DCRM respectively. Gross energy of DCRM was 5035 kcal/kg compared to GNC, 4752 kcal/kg. Result of aflatoxin $B_1$ revealed moderate level between 10 and $17{\mu}g/Kg$ in DCRM and GNC samples respectively. Birds on control gained 10 g, while those on DCRM and FCRM gained about 35 g and 120 g respectively. Feed intake declined (P < 0.05) with increased level of FCRM. Hen day production was highest in birds fed DCRM, followed by control and lowest value (P < 0.05) was recorded for FCRM. No significant change (P > 0.05) was observed for egg weight and shell thickness. Fat deposition and cholesterol content increased (P > 0.05) with increasing level of FCRM. The cost of feed per kilogram decreased gradually with increased inclusion level of CRM. The prediction equation showed the relative worth of DCRM compared to GNC was 92.3% whereas the actual market price of GNC triples that of DCRM. It was recommended that GNC could be completely replaced by DCRM in layer's diets in regions where this by product is abundant. However, FCRM should be cautiously used in diets of laying chickens.

A Study on Radiographical Conditions and Exposure Doses During Chest Radiography at Medical Facilities in Pusan (부산지역 의료기관의 흉부촬영 조건과 피폭선량에 관한 조사연구)

  • Jeon, Sung-Oh;Cho, Young-Ha
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.49-55
    • /
    • 1997
  • This study was carried out to investigate radiographical and operating conditions of X-ray units and exposure doses to patients during chest radiography, so that the results could provide basic data used for reducing the exposure dose and for providing the diagnostic information with better quality. The conditions and exposure doses of 100 X-ray units mainly used for chest radiography were examined and also 100 radiological technologists mainly handling those apparatus at 76 medical facilities in Pusan were surveyed using a questionnaire from October 1 to December 31 in 1995. The following results were obtained from the study : 1. It was found that most units were capable of taking a high tube voltage radiography by showing 67% of the units equipped with the maximum tube voltage of 150 kV, 94% with more than 500 mA for the rating capacity and 85% with the full wave type of a signal phase. 2. For actual chest radiographical conditions, however, 80% of the units were operated at $60{\sim}100\;kVp$ and only 14% at 100 kVp and over for the high tube voltage. 3. The average exposure time was less than 0.1 second, and eighty four percent of the units adapted the X-ray tube currents ranging from 200 to 300 mA, 80% the focus-film distances between 180 and 210 cm, and 63% the focus sizes of more than 2.0 mm. 4. Most units(98%) employed additional filters made of aluminum, 75% the thickness of filters less than 2.0 mm, and only 2 units the compound filters. 5. Ortho chromatic system was only adopted in 13% of screen film system for the units, and 73% used the grid ratio at 8 : 1 for the low tube voltage during chest radiography. 6. The average exposure dose of all X-ray units during chest radiography was $371\;{\mu}Sv$ with a difference of about 16 times between the minimum to the maximum, and $386\;{\mu}Sv$ both at hospitals and at health centers, followed by $380\;{\mu}Sv$ at general hospitals and $263\;{\mu}Sv$ at university hospitals without showing any statistically significant differences. In conclusion, since patients during chest radiography at medical facilities in Pusan exposed to high levels of radiation, it is recommended that appropriate added filters and grids necessary for the high tube voltage radiography and high-speed screen systems should be adopted and used as soon as possible in order to reduce exposure dose to the patients.

  • PDF

Entrance Skin Dose and Image Quality Evaluation According to Use Grid Radiography for the Extremity in FPD System (FPD System에서 상.하지 촬영 시 격자에 따른 환자 선량 및 화질 평가)

  • Lee, In-Ja;Yeo, Young-Bok;Lee, Tae-Sung
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.341-348
    • /
    • 2010
  • By accessing the current status of FPD system use in the hospitals located in Seoul and Gyeonggi Province as well as the entrance skin dose and the image quality evaluation realized by C-D Phantom, and the image assessment by the medical professionals regarding the radiography for the extremity, the following results were derived. 1. According to the evaluation made in the actual use of FPD system (12 machines), the grid ratio varied from 8:1 to 13:1, and 6 machines used the grid ratio with 12:1, realizing the largest number. Among the machines, there were 8 machines that allowed a removable grid while 3 machines did use a removable grid (25.0%). 2. When it came to the equipments used for the experiment, it showed that the amount of the entrance skin dose increased from 4.13 times up to 4.79 times with the grid use. 3. The difference in the entrance skin dose depending on the changes in the exposure condition(0.5times or 2.0times) was not significantly different regardless of the patients' thickness. 4. In terms of the image quality depending on C-D Phantom, the grid use was distinguished well. However, the images were well distinguishable as the exposure condition got increased. 5. In the clinical assessment, the grid use was less effective for the Hand PA, which was considered to shoot a thin body part. It was evaluated that the grid use was preferred for the Knee AP, which was shooting for a relatively thick body part. Nonetheless, 3 out of 5 people said that they would not use the grid if the entrance skin dose to reduced.

Design Methods for Eccentrically Loaded Bolt Groups for the Single Plate Connections Considering Sloped Edge Distance (편심전단을 받는 단일판접합부의 경사연단거리를 고려한 볼트군의 설계법)

  • Choi, Sun Kyu;Yoo, Jung Han;Park, Jai Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.1
    • /
    • pp.43-53
    • /
    • 2014
  • A single plate connection(SPC) consists of a plate welded to the columns and bolts connected to the beam web. The SPC is widely used for a simple shear connection of steel structure because it is easy-to-fabricated, easy-to-installed and economical. The conventional SPC is used for 2 to 12 bolts in a single vertical row. It is designed to limit the plate thickness by bolt diameter to obtain flexible and ductile connections. The design strength for eccentric shear shall be the lesser of the shear strength of bolts or bearing strength of plate and when the design strength is decided by edge distance failure, the results can be very conservative. Although the research on special solution for 'weak-plate/strong-bolt' model with 2 to 4 bolts has been conducted by L. S. Muir, and W. A. Thonton, 2004, study on generalized design procedures did not conduct. This study proposed design procedure for evaluation of the design strength of eccentric shear bolt groups on a single plate connection based on the actual edge distance and the direction of bolt reaction forces by using elastic vector method(EVM) and instantaneous center of rotation method(ICM).

Optimization of preform mold injection molding process for hemispheric plastic structure fabrication (반구형 플라스틱 구조체 성형을 위한 프리폼 몰드 사출성형공정 최적화)

  • Park, Jeong-Yeon;Ko, Young-Bae;Kim, Dong-Earn;Ha, Seok-Jae;Yoon, Gil-Sang
    • Design & Manufacturing
    • /
    • v.13 no.2
    • /
    • pp.30-36
    • /
    • 2019
  • Traditional cell culture(2-dimensional) is the method that provide a nutrient and environment on a flat surface to cultivate cells into a single layer. Since the cell characteristics of 2D culture method is different from the characteristics of the cells cultured in the body, attempts to cultivate the cells in an environment similar to the body environment are actively proceeding in the industry, academy, and research institutes. In this study, we will develop a technology to fabricate micro-structures capable of culturing cells on surfaces with various curvatures, surface shapes, and characteristics. In order to fabricate the hemispheric plastic structure(thickness $50{\mu}m$), plastic preform mold (hereinafter as "preform mold") corresponding to the hemisphere was first prepared by injection molding in order to fabricate a two - layer structure to be combined with a flat plastic film. Then, thermoplastic polymer dissolved in an organic solvent was solidified on a preform mold. As a preliminary study, we proposed injection molding conditions that can minimize X/Y/Z axis deflection value. The effects of the following conditions on the preform mold were analyzed through injection molding CAE, [(1) coolant inlet temperature, (2) injection time, (3) packing pressure, (4) volume-pressure (V/P). As a result, the injection molding process conditions (cooling water inlet temperature, injection time, holding pressure condition (V / P conversion point and holding pressure size)) which can minimize the deformation amount of the preform mold were derived through CAE without applying the experimental design method. Also, the derived injection molding process conditions were applied during actual injection molding and the degree of deformation of the formed preform mold was compared with the analysis results. It is expected that plastic film having various shapes in addition to hemispherical shape using the preform mold produced through this study will be useful for the molding preform molding technology and cast molding technology.