• Title/Summary/Keyword: actual size test

Search Result 255, Processing Time 0.03 seconds

Study on the Accuracy of Vessel Measurement According to Table Object Distance Changes (혈관조영장비의 테이블-피사체간 거리 변화에 따른 혈관측정 정확도 연구)

  • Kim, Seung-Gi
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.435-440
    • /
    • 2019
  • This is to study the accuracy of the actual size according to the TOD(table object distance; TOD) change when measuring blood vessels using angiography equipment, and to help the optimal selection of the device used accordingly. Balls similar to the size of common vessels were calibrated with TOD using 30 mm, 20 mm, 10 mm, 5 mm and acrylic phantoms, catheter calibration from 0 cm to 10 cm, 20 cm and 30 cm, respectively. It was measured whether there was a change in the measured value according to the change. The equipment used was GE Innova 3131 IQ equipment, and the image reconstruction method was GE AW4.7 post processing program. Two radiotechnologists were scanned three times by catheter calibration method and 3DRA(3dimension rotational angiography; 3DRA) volume rendering method. The independent sample T-test showed 0.981 (p> 0.05) to verify the significance between the two observers. As a result, in case of catheter calibration, the error rate at TOD 0 mm and 10 mm is within ± 10%, but when the TOD is changed to 20 mm and 50 mm respectively, the tolerance is ± 10% except for 30 mm ball exceeded. On the other hand, 3DRA was included within the tolerance range of ± 10% overall even when the TOD was changed from 0 mm to 50 mm. In the catheter calibration method, the larger the TOD, the larger the error range, and the 3DRA method was able to measure vascular vessels accurately close to the actual measurement without any consideration of the TOD.

A Study on the DBS Receive Tracking Antenna Apparatus on a Ship by the Az/El Mount (Az/El 마운트에 의한 선박용 DBS 수신추적안테나 장치에 관한 연구)

  • 최조천;양규식
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.1 no.2
    • /
    • pp.209-220
    • /
    • 1997
  • DBS offers actual services to mass-media and communication system of very broad region in information society. Especially, the DBS is the only system to access TV broadcasting service on a sailing ship. But the ship's DBS receiver is required a complex antenna tracking system because ships are under complex moving such as pitch, roll, and yaw etc. This study is motivated to develop a tracking antenna system to receive the koreasat on small silo ship. Therefore, this system is researched to small size, light weight, simple operation, and low cost of the product. The mount structure have been a compact size and easy operation to the Az/El 2-axis type which is operated by step motor. And it is very useful on a ship in the around sea of korean peninsula. The antenna has a plate type of micro-strip array, and is a domestic production. The vibration sensor is selected to gyro sensor of ultra-sonic rate type for ship's moving control. Tracking method is used the step-tracking algorithm, and the ship's moving compensation is adapted to the closed loop control method by ship's moving detection of gyro sensor. Tracking test is operated by the ship's moving simulator, we examined the actual receiving state on sailing shipboard in the near sea of korean peninsular.

  • PDF

Hydraulic Evaluation and Performance of On-Site Sanitation Systems in Central Thailand

  • Koottatep, Thammarat;Eamrat, Rawintra;Pussayanavin, Tatchai;Polprasert, Chongrak
    • Environmental Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.269-274
    • /
    • 2014
  • On-site sanitation systems are typically installed to treat grey and toilet wastewaters in areas without sewer and centralized treatment systems. It is well known that, due to inappropriate design and operation, treatment performance of these systems in developing countries is not satisfactory in the removal of pathogens and organic matters. This research aimed to investigate the hydraulic conditions occurring in some on-site sanitation systems and the effects of hydraulic retention times (HRTs) on the system performance. The experiments were conducted with a laboratory-scale septic tank (40L in size) and an actual septic tank (600L in size), to test the hydraulic conditions by using tracer study with HRTs varying at 12, 24 and 48 hr. The experimental results showed the dispersion numbers to be in the range of 0.017-0.320 and the short-circuit ratios in the range of 0.014-0.031, indicating the reactors having a high level of sort-circuiting and approaching complete-mix conditions. The removal efficiency of $BOD_5$ was found to be 67% and the $k_{30}$ values for $BOD_5$ was $2.04day^{-1}$. A modified complete-mix model based on the relationship between $BOD_5$ removal efficiencies and HRTs was developed and validated with actual-scale septic tank data having a correlation coefficient ($R^2$) of 0.90. Therefore, to better protect our environment and minimizing health risks, new generation toilets should be developed that could minimize short-circuiting and improving treatment performance.

Capacity of Concrete Filled Carbon Tube Columns Based on the Comparison of Ductility and Energy Dissipation Capacity (연성도 및 에너지 소산능력 비교에 따른 콘크리트충전 탄소섬유튜브 기둥의 성능)

  • Lee, Kyoung-Hun;Hong, Won-Kee;Lee, Young-Hak;Kim, Hee-Cheul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.1 s.53
    • /
    • pp.29-35
    • /
    • 2007
  • Flexural capacity estimation test of concrete filled carbon tube (CFCT) column under the cyclic lateral load was carried out in this study. Thickness of carbon tube and winding angles of carbon fiber were chosen as test parameters and two types of column with square and circular sections were manufactured. To act axial and lateral load, three dynamic actuators were used and all specimens were made with actual size. Flexural stiffness, ability of deformation, energy dissipation capacity and ductility behavior. of CFCT column were analyzed with test data.

A Study on the Mechanical Reliability of Large-area Bi-facial Glass-to-glass Photovoltaic Modules (대면적 양면 태양광 모듈의 기계적 신뢰성 연구)

  • Yohan, Noh;Jangwon, Yoo;Jaehyeong, Lee
    • Current Photovoltaic Research
    • /
    • v.10 no.4
    • /
    • pp.111-115
    • /
    • 2022
  • For the high efficiency of the photovoltaic module, a high-output solar cell, which is the basis of photovoltaic power generation, is required. As the light receiving area of the solar cell increases, the light receiving area of the photovoltaic module also increases. Accordingly, recent trend is to use large-area solar cells such as M6 and M8 instead of M2-based solar cells for manufacturing the photovoltaic module and a study on the mechanical stiffness of the module with increased size is required. In this study, a mechanical load test corresponding to IEC-61215 was performed among the reliability tests of large-area photovoltaic modules. In order to confirm the degree to which the mechanical load test affects the photovoltaic module, the output and EL images were checked by sequentially increasing the pressure by 600 Pa at a pressure of 2400 Pa. Also, factors such as output and efficiency of large-area photovoltaic modules were verified through mechanical load testing of actual large-area photovoltaic modules and the rate of change was very small at 1%.

Application of fluorescent particles as a tracer to detect the membrane surface damage in a pilot scale membrane bioreactor (형광입자를 이용한 분리막 표면 검측 방법의 파일럿 규모 플랜트 적용)

  • Kim, Choah;Kim, Hee Jun;Cho, Jinwoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.1
    • /
    • pp.33-40
    • /
    • 2016
  • In this study, a fluorescent silica nano particle is used as the surrogate for challenging test of membrane surface integrity. The particles are functionalized by a fluorescent dying agent so that as an ultraviolet light is imposed a bright fluorescent image from the particles can be taken. If a membrane surface is damaged and has a compromised part larger than the size of surrogate the fluorescent particles would pass through and contained in the permeate. An operator can directly notice whether the membrane surface is damaged or not by detecting a fluorescent image taken from the permeate. Additionally, the size of compromised part is estimated through analysing the fluorescent image in which we surmise the mass of particles included in the permeate by calculating an average RGB value of the image. The pilot scale experiments showed that this method could be applied successfully to determine if a membrane surface had a damaged parts regardless of the test condition. In the testing on the actual damaged area of $4.712mm^2$, the lowest error of estimating the damaged area was -1.32% with the surrogate concentration of 80 mg/L, flux of $40L/m^2/hr$ for 25 minutes of detection. A further study is still going on to increase the lowest detection limit and thus decrease the error of estimation.

Characteristics of Deformation and Shear Strength of Parallel Grading Coarse-grained Materials Using Large Triaxial Test Equipment (대형삼축시험에 의한 상사입도 조립재료의 변형 및 전단강도 특성)

  • Jin, Guang-Ri;Snin, Dong-Hoon;Im, Eun-Sang;Kim, Ki-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.12
    • /
    • pp.57-67
    • /
    • 2009
  • Along with the advanced construction technologies, the maximum size of coarse aggregate used for dam construction ranges from several cm to 1m. Testing the original gradation samples is not only expensive but also causes many technical difficulties. Generally, indoor tests are performed on the samples with the parallel grading method after which the results are applied to the design and interpretation of the actual geotechnical structure. In order to anticipate the exact behavior characteristics for the geotechnical structure, it is necessary to understand the changes in the shear behavior. In this study, the Large Triaxial Test was performed on the parallel grading method samples that were restructured with river bed sand-gravel, with a different maximum size, which is the material that was used to construct Dam B in Korea. And the Stress - Strain characteristics of the parallel grading method samples and the characteristics of the shear strength were compared and analyzed. In the test results, the coarse-grained showed strain softening and expansion behavior of the volume, which became more obvious as the maximum size increased. The internal angle of friction and the shear strength appeared to increase as the maximum size of the parallel grading method sample increased.

Distribution of X-ray Strength in Exposure Field Caused by Heel Effect (양극의 경사각 효과에 따른 조사야 X-선 강도 분포)

  • Jang, Keun-Jo;Kim, Nam-Hun;Lee, Jun-Haeng;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.223-229
    • /
    • 2011
  • When negative electron in x-ray tube is accelerated in to a high speed and then the currency of the electron is blocked by the target, x-ray happens by the conversion of the energy. The real area where the fast accelerated electron collides to a target area is called actual focal spot. When the string focused size is observed at the central ray side, where the direction x-ray comes out, the size seems to be reduced. This focus is called effective focal spot. According to radiation angle of x-rays tube, the degree of the negative pole side presents higher value than inclination, the amount of exposed radiation that patient receives differs by the angle of positive pole, which means effective focal spot is the variable. This paper presents the correlation between size of effective focal spot and amount of exposed radiation to the patient by it, and effective research for homogenized dose dispersion by the size of effective focal spot. In conclusion, following the focal size, effective range which was -8cm ~ 0 cm on average, was found and average dose rate was 0.019 R/min. Through this range, for patients with small radiation exposure, image with good density and resolution in aspect of diagnosing will be able to be obtained.

Two Dimensional Size Effect on the Compressive Strength of T300/924C Carbon/Epoxy Composite Plates Considering Influence of an Anti-buckling Device (T300/924C 탄소섬유/에폭시 복합재 적층판의 이차원 압축 강도의 크기효과 및 좌굴방지장치의 영향)

  • ;;;C. Soutis
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.88-91
    • /
    • 2002
  • The two dimensional size effect of specimen gauge section (length x width) was investigated on the compressive behavior of a T300/924 [45/-45/0/90]3s, carbon fiber-epoxy laminate. A modified ICSTM compression test fixture was used together with an anti-buckling device to test 3mm thick specimens with a 30$\times$30, 50$\times$50, 70$\times$70, and 90mm$\times$90mm gauge length by width section. In all cases failure was sudden and occurred mainly within the gauge length. Post failure examination suggests that $0^{\circ}$ fiber microbuckling is the critical damage mechanism that causes final failure. This is the matrix dominated failure mode and its triggering depends very much on initial fiber waviness. It is suggested that manufacturing process and quality may play a significant role in determining the compressive strength. When the anti-buckling device was used on specimens, it was showed that the compressive strength with the device was slightly greater than that without the device due to surface friction between the specimen and the device by pretoque in bolts of the device. In the analysis result on influence of the anti-buckling device using the finite element method, it was found that the compressive strength with the anti-buckling device by loaded bolts was about 7% higher than actual compressive strength. Additionally, compressive tests on specimen with an open hole were performed. The local stress concentration arising from the hole dominates the strength of the laminate rather than the stresses in the bulk of the material. It is observed that the remote failure stress decreases with increasing hole size and specimen width but is generally well above the value one might predict from the elastic stress concentration factor. This suggests that the material is not ideally brittle and some stress relief occurs around the hole. X-ray radiography reveals that damage in the form of fiber microbuckling and delamination initiates at the edge of the hole at approximately 80% of the failure load and extends stably under increasing load before becoming unstable at a critical length of 2-3mm (depends on specimen geometry). This damage growth and failure are analysed by a linear cohesive zone model. Using the independently measured laminate parameters of unnotched compressive strength and in-plane fracture toughness the model predicts successfully the notched strength as a function of hole size and width.

  • PDF

Validation of Nutrient Intake Estimation based on One Serving Size (1인 1회 분량을 적용한 영양 섭취량 추정 타당도 평가)

  • Kim, Yi-Yeong;Kim, Mi-Hyun;Choi, Mi-Kyeong
    • The Korean Journal of Food And Nutrition
    • /
    • v.28 no.5
    • /
    • pp.871-879
    • /
    • 2015
  • 24-hour recall is the dietary assessment method most frequently used to evaluate dietary intake; however, accuracy is an issue when using this method, especially in large-scale studies. The purpose of this study was to assess the validity of dietary intake estimation using one serving size. Estimates of energy and nutrients taken in over a 24-hr period based on actual intake amount (24HRAI) and based on estimates of one serving size (24HRSS) were compared. Data were analyzed using a paired t-test, Pearson's correlation coefficients, and a cross-classification method. In male subjects, intake levels of energy, fat, vitamin C, vitamin $B_1$, Zn, and total food measured using 24HRAI were significantly higher than those measured using 24HRSS. In female subjects, intake of carbohydrates, fiber, fat, vitamin A, vitamin C, vitamin B complexes, various minerals, and total food measured using 24HRAI were significantly lower than those measured using 24HRSS. Energy-adjusted Pearson's correlation coefficients revealed that intake of all nutrients showed a significant positive relationship between the two measurement methods in both males and females. Cross-classification analysis revealed that 50.5~67.6% of women and 40.3~71% of men were classified in the same quartile of intake of each nutrient when comparing data from 24HRAI and 24HRSS. We conclude that using one serving size in 24-hr recall analysis was valid and therefore may be used in studies to assess food consumption in the general adult population. Also, this method can be used to classify energy and nutrient intake into quartile, which is useful in examining the association between diet and chronic diseases.