• Title/Summary/Keyword: actual size test

Search Result 255, Processing Time 0.019 seconds

A Study on the Operational Status of the Chamber for Testing the Thermal Performance of Curtain Walls

  • No, Sang Tae
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.147-154
    • /
    • 2014
  • The purposes of this study were to analyze criteria for measurement chamber design dedicated curtain wall, and how to measure of performance configuration and status of the chamber that is currently being used. Main dealing criteria is AAMA 1503-09. Measurement of data is made in curtain wall Mock-up experiment station with thermal imaging camera. Measurement data using thermal imaging cameras at Mock-up curtain was made at the test site. The results of this study were as follows; There is no U-value test method for actual size of curtain wall. The thermal test outdoor chamber showed heat loss in the connection part of indoor and outdoor chamber. And the indoor chamber showed unstable temperature distribution by height.

High-Fidelity Ship Airwake CFD Simulation Method Using Actual Large Ship Measurement and Wind Tunnel Test Results (대형 비행갑판을 갖는 함정과 풍동시험 결과를 활용한 고신뢰도 함정 Airwake 예측)

  • Jindeog Chung;Taehwan Cho;Sunghoon Lee;Jaehoon Choi;Hakmin Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.2
    • /
    • pp.135-145
    • /
    • 2023
  • Developing high-fidelity Computational Fluid Dynamics (CFD) simulation methods used to evaluate the airwake characteristics along a flight deck of a large ship, the various kind of data such as actual ship measurement and wind tunnel results are required to verify the accuracy of CFD simulation. Inflow velocity profile at the bow, local unsteady flow field data around the flight deck, and highly reliable wind tunnel data which were measured after reviewing Atmospheric Boundary Layer (ABL) simulation and Reynolds Number effects were also used to determine the key parameters such as turbulence model, time resolution and accuracy, grid resolution and type, inflow condition, domain size, simulation length, and so on in STAR CCM+. Velocity ratio and turbulent intensity difference between Full-scale CFD and actual ship measurement at the measurement points show less than 2% and 1.7% respectively. And differences in velocity ratio and turbulence intensity between wind tunnel test and small-scale CFD are both less than 2.2%. Based upon this fact, the selected parameters in CFD simulation are highly reliable for a specific wind condition.

A Study on Pattern Development of Pet Dog's Wear through Movement analysis of Pet Dog (애견(愛犬)의 동작분석(動作分析)을 통(通)한 애견복(愛犬服)패턴 개발연구(開發硏究))

  • Shim, Boo-Ja;Suh, Chu-Yeon
    • Journal of Fashion Business
    • /
    • v.7 no.2
    • /
    • pp.1-14
    • /
    • 2003
  • This study were to grasp the present situation of the pet wear market and the problem of pet wear, and to develop the pet wear pattern which agrees well to dog's shape and movements. We carried out survey research to analyze the actual pet wear market condition for a dog-lover, and movement analysis and sensory test to develop a pattern for Maltese which was the favorite dog among Korean. For data analysis, ANOVA with duncan test, T-test were conducted using SPSS statistic program(ver. 10.0). The results are as follows: 1. The results of the survey research, 75% of dog-lover had a pet wear and favorite was T-shirts. The problems of wearing T-shirts were 'too tight seam sleeve and bodice(front legs hole)', 'the clothes easily hang down' and 'easily taken off due to large neck size'. 2. The ease amount of the developed pattern was given according to the results of dog's shape and movement analysis, and the results of sensory test, there is a significant difference in the following items: depth of front neck line, front chest${\to}$abdomen curve, ease amount of sleeve, comfort level of leg parts. 3. The size of each parts of the developed pattern in this study were as follows : neck girth 27.0cm, body girth 40.0cm, back length 26.0cm, front leg girth 23.0cm, sleeve length 20.7cm, sleeve width 14.4cm. But, there exists some limits to generalize these results since dog's body size and shapes are various according to dog species. Therefore, further studies are needed to develop each pet wear pattern for each dog species.

A Study of the Development of Jacket Patterns for Women in Their 20's (20대 여성을 위한 재킷패턴 개발에 관한 연구)

  • Shin, Jang-Hee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.16 no.3
    • /
    • pp.1-13
    • /
    • 2014
  • This study investigated body type among women in their 20s and the development of prototypes for tailored jackets by body type in order to design clothes in consideration of an imbalance in body type caused by the popularity of portable devices such as smartphones and Netbooks. This study aims to create a design of jacket patterns by body type through both actual and virtual wear testing among women in their 20s, who are the major consumer of ready-made clothes and are very sensitive to size fit. This study will provide pattern information for the manufacture of jackets with a goal of securing the latest scientific body type information and establish the grounds for a research method in the manufacture of clothes. According to actual and virtual wear tests of four different body types, a significant difference was found in armhole circumference in most types because it was scanned with the arms slightly apart to prevent the armhole area from being missed during the 3D scanning. This has resulted in a slight distortion in measurements. To correct this problem, it is necessary to verify the precision of the body scanner and its program. In categories in which a large significant difference was found, it is necessary to test them against many subjects. In addition, it would be required to perform a further study on the 3D virtual wear system, which could be useful in the clothing industry.

  • PDF

Control Strategy Development of 4WD Vehicles based on Heuristic Approach and Dynamic Characteristic (경험적 접근법과 동역학적 특성에 기반한 4WD 차량의 제어 전략 개발)

  • Ham, Hyeongjin;Lee, Hyeongcheol
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.6
    • /
    • pp.209-217
    • /
    • 2013
  • This paper presents a control strategy of 4 wheel drive (4WD) vehicles. Proposed control strategy has simple structure and can easily apply to various vehicles with low cost and time. It is consist of feedforward control for traction ability, fedback control for minimizing the wheel speed difference and yaw control for lateral stability. In addition, to integrate the traction and stability control, a blending function is applied. To evaluate the feasibility of the proposed control strategy, actual vehicle experiment is conducted after deciding the tuning parameter through the simulation. The simulation is accomplished by CarSim and Matlab/Simulink and the actual vehicle test is conducted using full size Sports Utility Vehicle (SUV) equipped rear wheel based solenoid type 4WD device.

He Study of Fire Suppression Capability of Low Pressure Water-Mist System for Wooden Cultural Properties (목조한옥에 대한 저압식 미분무 소화설비의 소화성능에 관한 연구)

  • Roh, Sam-Kew;Kim, Dong-Cheol;Ham Eun-Gu
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.401-410
    • /
    • 2012
  • The study verified the extinguishing performance of the low pressure water-mist system, which is used to extinguish fire at domestic wooden architecture, through a fire test. Made of inflammable materials, a wooden house is vulnerable to fire, and the size of fire may vary from the early stage in case of arson. With the discharging pressure of 8 bar and the flow rate of 35 lpm, the low pressure water-mist nozzle used in the experiment has considerable discharging amount compared to other water-mist nozzles. The extinguishing performance was tested based on the size of fire and architecture. Test results demonstrated that the extinguishing performance was not affected by the size of a house, but decreased significantly when the size of fire was above unit 1. Taking into account that the environment of actual wooden cultural properties is more vulnerable than that of the experiment model, sufficient investigation on extinguishing performance is required to apply the water-mist extinguishing system to wooden architecture.

Frost resistance of porous concrete assuming actual environment (實環境を考慮したポーラスコンクリートの耐凍害性の評価(실제 환경을 고려한 다공질 콘크리트의 내동해성(耐凍害性) 평가))

  • NAKAMURA, Takuro;HORIGUCHI, Takashi;SHIMURA, Kazunori;SUGAWARA, Takashi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.227-233
    • /
    • 2008
  • Porous concrete has large continuous voids of 20-30 % by volume, and this concrete is attractive as environmental material in Japan i.e. permeable road pavement, river bank protection with vegetation and green roof system which influence thermal environment. It is necessary to confirm the frost resistance when constructing porous concrete structure in cold region. However applicable test method and evaluation criterion of porous concrete has not defined yet. Therefore, the object of this study is to investigate the frost resistance of porous concrete and this investigation attempts to address this concern by comparing 4 kinds of specified freezing and thawing tests methods (JIS A1148 procedure A/B and RILEM CIF/CDF test) in consideration of actual environment. RILEM freeze-thaw tests are different from JIS A1148 freeze-thaw tests, which are widely adopted for evaluating the frost resistance of conventional concrete in Japan, in water absorption, cooling rate, length of freezing and thawing period, and number of freezing and thawing cycles. RILEM CIF test measures internal damage and is primarily applicable for pure frost attack. CDF test is appropriate for freeze-thaw and de-icing salt attack. JIS A1148 procedure A/B showed extremely low frost resistance of porous concrete if the large continuous voids were filled with water and the ice expansion in the large continuous voids set in during cooling. Frost resistance of porous concrete was improved by mixing coarse aggregate (G7) which particle size is smaller and fine aggregate in JIS freezing and thawing tests. RILEM CIF/CDF test showed that freeze-thaw and de-icing resistance of porous concrete was seems to be superior in that of conventional concrete.

  • PDF

A Study on the design of Unmanned Autonomous Helicopter for Aerial Monitoring and Control of a Large Size Disaster and Forest Fire (대형재난 및 산불 공중지휘통제용 무인자율헬기 개발에 관한연구)

  • Kim, Jong-Kwon;Kwark, Ji-Hyun;Son, Bong-Sei
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.105-110
    • /
    • 2008
  • Unmanned helicopter has several abilities such as vertical take off, hovering, low speed flight at a specific altitude. Such vehicles are becoming popular in actual applications such as search and rescue, aerial reconnaissance and surveillance in the case of a large size disaster and forest fire. In this paper, a flight control system was designed for an unmanned helicopter. This paper was concentrated on describing the systematic design, electronic equipments and their interconnections for realizing the autonomous flight and aerial monitoring. A study on the autonomous waypoint navigation and altitude control performance were performed and tested on a test unmanned helicopter and the performance and the feasibility were represented.

  • PDF

Evaluation of Bearing Strength for Composite Joint (합성접합부에서 지압내력 평가식)

  • 김병국;최완철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.347-352
    • /
    • 2002
  • Recent trends in the construction of building frame feature the increase use of composite steel concrete members functioning together in what terms of mixed structural systems. One of such systems, RCS(reinforced concrete column and steel beam) system is introduced and closely examined focusing on bearing strength of the composite joint in this paper. The main objective of this study was to develope one of details to increase bearing capacity while bearing failure is one of the two primary modes of failure in RCS system. Local bearing tests with specimens about 1/3 of the actual concrete column size were performed applying uniform load through steel plate with 100$\times$110mm size. Test results show that specimens with the bearing reinforcement detail developed in this study enhanced the bearing strength by 1.71~3.02 compared to concrete cylinder strength.

  • PDF

Scale Model Testing of a two-boat midwater trawl net (2척식 중층트롤 모형실험)

  • Jang, Ji-Won;Kim, Chun-Duk;Kim, Tae-An
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.5 no.1
    • /
    • pp.14-20
    • /
    • 1969
  • A scale model net test of the operation of a small two-boat midwater trawl net was performed in the circulating water tank at Pusan Fisheries College. The 1/32 scale model net was constructed after the modelling law of M. Tauti. This type of net is used in Europe for catching sprat like Hering. The net used was 1/32 the actual size. This scale was chosen with consideration for the water tank size. In this experiment, the transfomation of the net shape was observed especially inregard to variations in the height and breadth of the net mouth. These dimensions were varied by changing the breadth of the towing line and the connenting spread.

  • PDF