• Title/Summary/Keyword: active safety system

Search Result 510, Processing Time 0.028 seconds

Integral effect tests for intermediate and small break loss-of-coolant accidents with passive emergency core cooling system

  • Byoung-Uhn Bae;Seok Cho;Jae Bong Lee;Yu-Sun Park;Jongrok Kim;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2438-2446
    • /
    • 2023
  • To cool down a nuclear reactor core and prevent the fuel damage without a pump-driven active component during any anticipated accident, the passive emergency core cooling system (PECCS) was designed and adopted in an advanced light water reactor, i-POWER. In this study, for a validation of the cooling capability of PECCS, thermal-hydraulic integral effect tests were performed with the ATLAS facility by simulating intermediate and small break loss-of-coolant accidents (IBLOCA and SBLOCA). The test result showed that PECCS could effectively depressurize the reactor coolant system by supplying the safety injection water from the safety injection tanks (SITs). The result pointed out that the safety injection from IRWST should have been activated earlier to inhibit the excessive core heat-up. The sequence of the PECCS injection and the major thermal hydraulic transient during the SBLOCA transient was similar to the result of the IBLOCA test with the equivalent PECCS condition. The test data can be used to evaluate the capability of thermal hydraulic safety analysis codes in predicting IBLOCA and SBLOCA transients under an operation of passive safety system.

Analysis of Continuously Variable Damper Characteristics for Semi-Active Suspension Systems (반능동형 현가시스템을 위한 연속가변댐퍼의 특성 해석)

  • 허승진;박기홍
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.7
    • /
    • pp.128-137
    • /
    • 2003
  • Continuously variable damper can yield diverse damping forces for a single damping velocity. It is widely used in the semi-active suspension system since, with right control logics, it can enhance ride comfort compared to the passive damper while not degrading driving safety. A key to the successful design of the continuously variable damper is the knowledge of its complex and nonlinear characteristics. In this paper, research has been done for analyzing characteristics of the continuously variable damper. Various damper components have been investigated and their effects upon the force-velocity characteristics of the damper have been examined. The effects of the damper characteristics change upon ride comfort and driving safety have also been investigated by numerical simulations.

GA-based Optimal Fuzzy Control of Semi-Active Magneto-Rheological Dampers for Seismic Performance Improvement of Adjacent Structures (인접구조물의 내진성능개선을 위한 준능동 MR감쇠기의 GA-최적퍼지제어)

  • Yun, Jung-Won;Park, Kwan-Soon;Ok, Seung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.4
    • /
    • pp.69-79
    • /
    • 2011
  • This paper proposes a GA-based optimal fuzzy control technique for the vibration control of earthquakeexcited adjacent structures interconnected with semi-active magneto-rheological(MR) dampers. Rule-based fuzzy logic controllers are designed first by implementing heuristic knowledge and the genetic algorithm(GA) is then introduced to optimally tune the fuzzy controllers for enhancing the seismic performance of semi-active control system. For practical implementation, the fuzzy controller simply uses locally measured responses of the dampers involved and directly returns the input voltage to the magneto-rheological dampers in real time through the fuzzy inference mechanism. The local measurement based fuzzy controller provides optimal damping force in a decentralized manner so that it does not require a primary central controller unlike the conventional semi-active control techniques. As a result, it can avoid the unbridgeable discrepancy between the desired control force and the actual damper force that may occur in the conventional control approaches. The validity and effectiveness of the proposed control method are shown numerically on two 20-story earthquake-excited buildings interconnected with MR dampers.

Damping performance Analysis for an Electronically Contralled Shock Absorber (연속 가변형 충격흡수기의 감쇠성능 해석)

  • 박재우;이동락;백운경
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.2
    • /
    • pp.192-201
    • /
    • 2001
  • Analyzing internal structure, flow rate and dynamic behavior characteristics of electronically controlled shock absorber, damping performance limit is identified to comprise the two reciprocal characteristics of ride comfort and handling safety. Regardless of its lower performance than the active suspension control system, the semi-active suspension control system has been taking interest because of its absolutely higher performance than passive suspension system. Since the pervious studies have been concentrated mostly on analytic aspect and survey on the internal structure of the shock absorber remain insufficient, the main discourse of this paper is focused on analyzing the nonlinear shock absorber which varies the damping force of semi-active suspension system and the dynamic characteristics of the solenoid valve, a sort of pressure valve, and proposing the design factors of importance.

  • PDF

A Novel Active Clamp Switching Method To Improve of Efficiency For Photovoltaic MIC (태양광 MIC 시스템의 효율향상을 위한 새로운 Active Clamp 스위칭 기법)

  • Park, Byung-Chul;Park, Ji-Ho;Song, Sung-Geun;Park, Sung-Jun;Shin, Joong-Rin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.477-484
    • /
    • 2013
  • This paper proposes a novel switching method of active clamp snubber for efficiency improvement of PV module integrated converter(MIC) system. Recently, MIC solar system is researched about the efficiency and safety. PV MIC system is used active clamp method of snubber circuit for the price and reliability of the system. But active clamp snubber circuit has the disadvantage that system efficiency is decreased for switch operating time because of heat loss of resonant between snubber capacitor and leakage inductance. To solve this problem, this paper proposes a novel switching method of the active clamp. The proposed method is a technique to reduce power consumption by reducing the resonance of the snubber switch operation time and through simulations and experiments proved the validity.

Experimental Study on the Active Control of Building Using Sliding Mode Control Method (슬라이딩 모드제어 기법을 적용한 건물의 능동제어 실험)

  • 김성춘;박정근;민경원;정진욱
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.431-435
    • /
    • 2001
  • The active structural control has emerged as structural safety of structures against natural loadings such as earthquake and wind loadings. Of many control algorithms, Sliding-Mode Control (SMC) can design both linear controller and nonlinear controller. The robustness against parameter variations as well as excitation uncertainties that is imparted to the SMC due to its nonlinear control action, could make SMC an attractive control algorithm when dealing with structures where the external excitation constitutes the main uncertainty in the system. This paper demonstrates experimentally the efficacy of the SMC algorithm based on the active mass driver system in reducing the response of seismically excited buildings. The SMC control strategy is verified with the experimental study on the one-story building model equipped with the active mass driver.

  • PDF

Function Analysis for the active surveillance system of urban transit (도시철도의 능동적 감시체계를 위한 기능 분석)

  • An, Tae-Ki;Shin, Jeong-Ryul;Lee, Woo-Dong;Han, Seok-Yoon;Kim, Moon-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1027-1028
    • /
    • 2008
  • Most of the urban transit operation company in Korea have a passive surveillance system to monitor the status of the passengers and facilities in the urban transit service area. The surveillance system is based on CCTV, closed circuit television, and several sensors, such as a fire sensor. However, this system has some limitations to prevent and cope with the emergency quickly. So the urban transit operation companies have plans to be change their surveillance system to be active. The active surveillance system has an intelligent function to detect the event predefined by managers automatically. To construct the active surveillance system, there are a standard concept design and a function analysis. In this paper, we propose the classification of the functions of the active surveillance system for urban transit. We divide the functions into five parts, ordinary monitoring, safety monitoring, environment monitoring, administration support, and record management. And we describe the systems related to the every functions to clarify the classified functions.

  • PDF

Functional Safety and Model-Based Systems Engineering - focusing on ISO 26262/DO-178C (기능 안전과 모델기반 시스템엔지니어링 - ISO 26262/DO-178C 중심으로)

  • Park, Joongyong;Paek, Seung-Kil
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.13 no.1
    • /
    • pp.57-65
    • /
    • 2017
  • Recently, the ratio of electrical part and embedded software has grown in automotive industry. ISO 26262, 'Road Vehicles - Functional Safety', was published to guide development of automotive electrical and electronic part in 2011. This paper describes definition of functional safety and analyzes ISO 26262. The comparison of ISO 26262 and DO-178C is made, then difference between them is identified. DO-178C provides guidance for the production of software for airborne system and equipment. The core of DO-178C is a relatively minor update to the previous DO-178B, however, the big changes are captured in the supplemented documents such as DO-331, 'Model-Based Development and Verification Supplement to DO-178C and DO-278A'. Model-based design is important to develop automotive and aircraft meeting the guidelines of ISO 26262 and DO-178C. In this paper, the sample case of applying MBSE(Model-Based Systems Engineering) to AVCS(Active Vibration Control System) software development is discussed.

Development of on Intelligent Automatic Door System Using Ultrasonic Sensors (초음파센서를 이용한 지능형 자동문시스템 개발)

  • Song, Dong-Hyuk;Chang, Byong-Kun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.31-39
    • /
    • 2009
  • This paper proposes an ultrasonic sensor based intelligent automatic door system which improves the performance of conventional door systems by adding more intelligent functions such that it offers more convenience to passersby and reduces power loss. The conventional automatic door systems employed passive and active infrared sensors for detecting objects and human bodies. But, they have problems such as power loss in door closing, not sensing fast approaching objects, and safety. The proposed automatic door system with ultrasonic sensors prevents unnecessary door closings to save the power and senses fast approaching objects to open the door at proper time, and improves safety. Thus, the proposed system improves the performance of the conventional systems in terms of operation, economy, and safety.

The study on Failover subsystem of SCADA system (SCADA 시스템의 FAILOVER SUBSYSTEM에 관한 연구)

  • Kim, Young-Tae;Cho, Nam-Bin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.835-837
    • /
    • 1999
  • Failover subsystem of computer consists four modes In this paper, These modes will be discussed in more detail. - dual computer mode - failover mode - single computer mode - standby synchronization mode we have suggested the method of dual/redunancy configulation of server computer. Failover is activated by the standby computer, active computer receives a failover request across the inter-computer link immediatly. The active computer controls the scada system and maintains the current state in it's data base and channel system safety.

  • PDF