• 제목/요약/키워드: active power compensation

검색결과 317건 처리시간 0.023초

An Investigation of Control Parameters of Active Filters Based on Voltage Detection

  • SATO Yukihiko;KAWASE Takeshi;MACHIDA Hiraku
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.475-479
    • /
    • 2001
  • Compensation characteristics or active filters based on voltage detection are investigated. These active filters act equivalently as a passive circuit so that they may not cause practical problems such as stimulation of resonance in the distribution lines. Thus, these active filters can be used as the general-purpose active filters. On the other hand, these active filters may have a possibility of the anti-resonance associated with the line inductance of the distribution lines. In this paper, the relationship between the anti-resonance and the control parameters of the proposed active filters is clarified. Some methods to avoid the problems due to the anti-resonance are investigated. Experimental results are included to confirm the validity of the investigation presented in this paper.

  • PDF

스트로크 포화를 고려한 직렬 복합형 감쇠기의 비선형 제어 (Nonlinear Control of Cascade Hybrid Mass Dampers considering Stroke Saturation)

  • 민경원;황성호;김성춘;호경찬;김인수
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 가을 학술발표회논문집
    • /
    • pp.377-386
    • /
    • 2000
  • Hybrid mass dampers consist of passive tuned mass dampers and active mass dampers. They have the advantage that passive tuned mass dampers are still operated even when active mass dampers are stopped by excessive disturbances or power failure. This paper begins first with the comparative analysis of tuned mass dampers, hybrid mass dampers, and active mass dampers. Next more detailed study is carried out on the hybrid mass dampers: cascade hybrid mass dampers (CHMD) and active tuned mass dampers (ATMD). CHMD is regarded as more reasonable device because of its lighter active mass than ATMD's. However CHMD can not neglect stroke saturation problem caused by the length limitation of active damper mass. We compensate the saturation problem with nonlinear restoring force. The restoring force is calculated based on the states and phases of active mass dampers and added to the control force. It is shown that the presented compensation method prevents CHMD from saturation behavior without apparent changes of control force and responses compared to those in case of not considering the saturation problem.

  • PDF

능동적 주파수 변환기법의 출력전류 고조파 왜형율 분석 (THD Analysis of Output Current for Active Frequency Drift Method in Anti-islanding)

  • 이기옥;최주엽;최익;유권종;안진웅
    • 한국태양에너지학회 논문집
    • /
    • 제30권1호
    • /
    • pp.7-12
    • /
    • 2010
  • As many grid-connected photovoltaic power conditioning systems (PVPCS)are installed in many residential areas simultaneously, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. In this paper, active frequency drift (AFD) method, one of the anti-islanding methods which is analyzed by current magnitude compensation and calculation of the fundamental component. Both harmonic component and RMS value of the output current for THD analysis are provided and verified by simulation.

해상풍력단지 전력계통 연계를 위한 무효전력 최적 보상용량 계산에 관한 연구 (A Study on the Calculation of Optimal Compensation Capacity of Reactive Power for Grid Connection of Offshore Wind Farms)

  • 한성민;박주혁;황창현;문채주
    • 한국전자통신학회논문지
    • /
    • 제19권1호
    • /
    • pp.65-76
    • /
    • 2024
  • 최근 해상풍력산업이 활성화되면서 기존 화력 발전소 규모의 400MW 급 발전단지들이 개발되고 있다. 재생에너지는 에너지원에 따라 간헐성이 큰 특성이 있고, 최신 재생에너지 발전설비들은 제어기능을 갖는 인버터 기술로 구성되는 특징이 있다. 이러한 재생에너지원의 계통연계 확대에 따라 전력계통 접속을 위한 그리드코드도 점점 구체화되고 있고, 이에 따라 관련 검토도 활발히 진행되고 있다. 본 논문에서는 그리드 코드 준수를 위해 여러 해상풍력 발전단지들을 통합하여 공동접속설비로 접속하는 경우, 최적 무효전력 보상용량 선정 방법에 대해 제안한다. 그리드 코드의 요구조건을 기반으로, 전북 서남해 400MW 풍력발전단지의 무효전력 보상과 과도안정도를 분석한다. 이 분석은 PSS/E를 사용하여 각 터빈 배치안과 케이블 데이터로 발전단지 DB를 구축하고, 내·외부망 케이블의 충전전류에 의한 무효전력과 연계점에서 무효전력 보상용량을 산출한다. 또한 전력계통 DB에 연계해서 정적, 동적 안정도를 고찰한다.

Comparison Analysis of Resonant Controllers for Current Regulation of Selective Active Power Filter with Mixed Current Reference

  • Yi, Hao;Zhuo, Fang;Li, Yu;Zhang, Yanjun;Zhan, Wenda
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.861-876
    • /
    • 2013
  • Instead of extracting every selected harmonic component, the current reference of selective active power filter (APF) can be also obtained by filtering out the fundamental component from distorted load current for computation efficiency. This type of mixed current reference contains kinds of harmonic components and easily involves noises. In this condition, selective harmonic compensation must be realized by the current controller. With regard that selectivity is the most significant feature of controller, this paper presents specific comparison analysis between two types of resonant controllers: proportional-resonant (PR) controller and vector-resonant (VR) controller. The comparison analysis covers the relations, performances, and stability of both controllers. Analysis results conclude that the poorer selectivity of the PR controller could be relatively improved, but limitations from system stability make the improvement hardly realized. By contrast, the VR controller exhibits excellent selectivity and is more suitable for selective APF with mixed current reference. Experimental results from laboratory prototype validate the reasonability of analysis. And the features of each resonant controller are concluded.

Level Number Effect on Performance of a Novel Series Active Power Filter Based on Multilevel Inverter

  • Karaarslan, Korhan;Arifoglu, Birol;Beser, Ersoy;Camur, Sabri
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.711-721
    • /
    • 2018
  • This paper presents a single-phase asymmetric half-bridge cascaded multilevel inverter based series active power filter (SAPF) for harmonic voltage compensation. The effect of level number on performance of the proposed SAPF is examined in terms of total harmonic distortion (THD) and system efficiency. Besides, the relationship between the level number and the number of switching device are compared with the other multilevel inverter topologies used in APF applications. The paper is also aimed to demonstrate the capability of the SAPF for compensating harmonic voltages alone, without using a passive power filter (PPF). To obtain the required output voltage, a new switching algorithm is developed. The proposed SAPF with levels of 7, 15 and 31 is used in both simulation and experimental studies and the harmonic voltages of the load connected to the point of common coupling (PCC) is compensated under two different loading conditions. Furthermore, very high system efficiency values such as 98.74% and 96.84% are measured in the experimental studies and all THD values are brought into compliance with the IEEE-519 Standard. As a result, by increasing the level number of the inverter, lower THD values can be obtained even under high harmonic distortion levels while system efficiency almost remains the same.

5[kVA]급 3상 능동전력필터를 위한 저가형 제어기 설계 (Design of Low Cost Controller for 5[kVA] 3-Phase Active Power Filter)

  • 이승요;채영민;최해룡;신우석;최규하
    • 전력전자학회논문지
    • /
    • 제4권1호
    • /
    • pp.26-34
    • /
    • 1999
  • 비선형 반도체 전력변화장치의 사용이 급증함에 따라 전원 측에 발생되는 고조파 및 무효전력을 보상하기 위한 능동전력필터에 관한 연구가 많이 이루어져 왔으며 실용화를 위한 노력이 계속 되고 있다. 그러나 수동필터 대비 능동전력필터의 가격이 아직까지는 고가이기 때문에 이의 상용화가 더디게 진전되고 있는 추세이며, 특히 소·중용량의 능동전력필터의 제어를 위하여 디지털 신호 처리용 프로세서인 DSP(digital signal processor)를 사용하는 경우 아직까지 그 가격이 고가이기 때문에 능동필터의 제어가격을 상승시키는 요인으로 작용한다. 한편 능동전력필터의 가격을 낮추기 위해 아날로그 제어기만을 도입하는 경우 제어회로가 너무 복잡해 지고 제어의 유연성이 떨어지는 단점을 수반하게 된다. 본 논문에서는 3상 5[kVA]급 농동전력필터의 저가형 제어기를 구현하기 위해 저가의 원칩 마이크로프로세서인 80C196KC를 사용하영 디지털 제어부를 구성하며 이를 통해 보상전류 성분의 계산 및 직류단 일정 전압제어를 수행하고, 능동필터 시스템의 전류제어를 위하여 아날로글 형태의 제어기인 히스테리시스 제어기를 함께 사용한다. 컴퓨터 시뮬레이션을 통해서 보상 시스템의 특성을 해석하였으며 실험에 의해 능동전력필터의 저가화를 위해 설계된 제어기가 고조파 및 무효전력 보상을 충실히 수행함을 확인하였다.

DVR을 이용한 전력품질 개선 (Power Quality Improvement using DVR)

  • 김성환
    • 전기전자학회논문지
    • /
    • 제25권3호
    • /
    • pp.462-466
    • /
    • 2021
  • DVR은 배전선로의 전압 변동을 보상하는 장치로 일반적으로 계통의 무효전력 보상, 역률개선 문제를 해결하는 장치와 결합하여 사용된다. 이러한 결합보상기기는 상대적으로 제어가 어렵고 부피가 커지는 단점을 갖는다. 본 논문에서는 DVR의 전력위상제어(Power Angle Contorl)방법을 적용하여 부가적인 보상기기의 결합이 없이 DVR 단독으로 배전선로의 무효전력과 전압변동을 동시에 보상하기 위해 보상 전압의 최대 크기와, 위상, 보상 가능한 무효전력 및 유효전력에 대한 수학적 해석을 수행하였다. 유효전력을 배터리에 충전하고 전압 변동시 저장된 에너지를 공급하기 위한 제어알고리즘을 개발하고 Matlab 시뮬레이션을 통해 결과를 확인하였다.

직류 부하에 대한 3상 복합형 전력 필터 설계 (A Design of Three-phase Hybrid Power Filter System for DC Loads)

  • 조동길
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.379-384
    • /
    • 2000
  • The reactive and harmonic current components of dc loads can be compensated by the three-phase hybrid power filter (HPF) system. After compensation, the resulting current has sinusoidal and in-phase components with the source voltage. The HPF system is constructed by an active filter and passive filters. The passive filter reduce the 5th and 7th harmonic of the load current. The active filter compensates the remainder of the load current. Using the HPF system, a low cost harmonic compensator can be made. Performance of the HPF system is verified through simulation,

  • PDF

전류제어 능동 클램프 포워드-플라이백 컨버터의 동특성 해석 및 제어회로 설계 (Dynamic Analysis and Control Design of Current-Mode Controlled Active-Clamp Forward-Flyback Converter)

  • 임원석;강용한;최병조
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.374-377
    • /
    • 2002
  • This paper presents dynamic analyses and control design of the current-mode controlled active-clamp forward-flyback converter. The circuit averaging technique is used to extract the small-signal circuit model for the power stage From the small-signal circuit model of the power stage, the open-loop transfer functions are derived and used for the compensation design. The analysis results are verified using an experimental converter that delivers a 3.3V/10A output from a $40\~60V$ input source.

  • PDF