• 제목/요약/키워드: active power compensation

검색결과 317건 처리시간 0.025초

비선형부하에 의해 발생한 전원 전류의 고조파를 제거하기 위한 단상 병렬형 Active Power Filter의 구현 (The Realization of a Single-Phase Parallel Active Power Filter to Eliminate Harmonics of Source Current Generated by Nonlinear Loads)

  • 장목순;이후찬;김상훈;박종연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.220-221
    • /
    • 2006
  • This paper presents a single-phase parallel active power filter with an analog control circuit to eliminate for harmonic source currents generated by nonlinear loads. The proposed system removes the harmonic source currents by injecting a compensation current that is 180' out of phase with the load harmonic current. The detection of the load harmonics is realized by a simple new structure, referred to the Notch Filter with GIC (Generalized Impedance Converter), which has higher Q than existing harmonic detecters and a simpler structure. The compensation current is obtained using the proposed harmonic detection circuit, DC-Link voltage, and output current of the full-bridge inverter controlled current mode PWM controller. The operation of the proposed system is verified experimentally.

  • PDF

An Adaptive Dead-time Compensation Strategy for a Permanent Magnet Synchronous Motor Drive Using Neural Network

  • Urasaki Naomitsu;Senjyu Tomonobu;Funabashi Toshihisa;Sekine Hideomi
    • Journal of Power Electronics
    • /
    • 제6권4호
    • /
    • pp.279-289
    • /
    • 2006
  • This paper presents a neural network based adaptive dead-time compensation strategy for an inverter fed permanent magnet synchronous motor drive. The neural network is used for identifying the dead-time compensation time (DTCT) that includes an equivalent dead-time, turn-on/off time and on-state voltage components of the voltage source inverter. In order to train the neural network, desired DTCTs for eight operating points are prepared as training data. The trained neural network can identify a desired DTCT for any operating point because it has the capability of the interpolation. The accuracy of the identified DTCT is experimentally confirmed by comparing the calculated active power with a measured one.

에너지저장시스템을 이용한 전력계통의 과도안정도 향상 (Transient Stability Enhancement of Power System by Using Energy Storage System)

  • 서규석
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.26-31
    • /
    • 2017
  • 전력계통의 과도안정도를 향상시키기 위해 종래에는 무효전력 보상장치를 설치하는 방법을 주로 사용하였다. 전통적인 무효전력 보상장치 중 SVC(Static Var Compensator), 변압기의 탭 변환기는 값이 싸고 기계적 스위칭으로 동작하여 속도가 느리다는 단점이 있고, 전력전자기술을 바탕으로 하는 STATCOM(Static Synchronous Compensator)은 고속으로 동작할 수 있는 장점이 있어 최근에 각광을 받고 있지만 고가의 장치라는 단점이 있다. 또한, 무효전력 보상장치에 기반한 전통적인 방법은 무효전력만을 공급하여 과도안정도를 향상시키기에 대형 전동기의 트립에 의한 급격한 전압붕괴를 막을 수 없다. 반면에 에너지 저장시스템은 무효전력과 유효전력을 동시에 공급할 수 있다. 즉, 선로사고로 인하여 부하에 유효전력의 공급이 감소하는 것을 ESS을 통한 유효전력을 공급함과 동시에 적절한 무효전력의 공급을 통하여 과도안정도를 향상시킬 수 있다. 전력계통의 사고 시 유효전력의 빠른 공급은 과도안정도 향상에 매우 중요한 역할을 한다. 본 논문에서는 대형 전동기 부하와 같은 큰 동적부하를 가지는 전력계통에 대하여 에너지저장시스템을 사용한 과도안정도 향상방법을 제시한다. 또한, 유효전력과 무효전력을 보상하는 방법이 기존의 방법보다 더 효과적으로 과도안정도를 향상시킴을 확인하였다.

엑티브필터를 사용한 태양광 발전시스템의 출력제어 (Control Method of Output of PV Generation System using Shunt Active Filter)

  • 성낙권;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.225-227
    • /
    • 2002
  • In this paper, novel concept of a photovoltaic(PV) power generation system adding the function of active filter(AF) is proposed. Even PV power generation system can be treated to a harmonics source for the power distribution system, it is necessary that the function of AF system in grid connected PV power generation system. Active Filters intended for harmonic solutions are expending their functions from harmonic compensation of nonlinear loads into harmonic isolation between utilities and consumer, and harmonic damping throughout power distribution system. So, the PV system combined the function of AF system can be usefully applied in power distribution system. Here, the control strategy of PV-AF system is introduced.

  • PDF

능동전력필터기능을 갖는 UPS에 관한 연구 (A Study on UPS with Active Power Filter Function)

  • 박인석;이정준;성낙규;오봉환;김성남;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2178-2180
    • /
    • 1998
  • Recently, for increasing consumed power and informational society, confidence of power supply is demanded. Beside, owing to most of these loads are nonlonear, utility line is polluted by these components, therefore, it is demanded compensation of harmonic current. In times past, special order of harmonic current is only compensated by passive filter, but active power filter can compensate whole harmonic current. Therefore, this paper propose uninterruptable power supply(UPS) with performance of active power filter.

  • PDF

위상변이를 이용한 배전용 정지형 보상기의 전류 지령 계산 (Current Reference Calculation for Distribution Static Compensator using Phase Shift)

  • 홍성민;최종우
    • 전력전자학회논문지
    • /
    • 제17권1호
    • /
    • pp.41-47
    • /
    • 2012
  • This paper proposes a calculation of compensation current using phase shift to eliminate ripple components of instantaneous active power under unbalanced or non-linear loads condition. The proposed phase shift method instead of existing method(LPF; Low Pass Filter) to remove ripple components and this proposed method improves performances of transient and steady state response. To compare proposed method with existing method, experiments have been done for calculating an average active power at load side. Their results show that transient response and steady state response of proposed method is improved.

A Fuzzy Based Solution for Allocation and Sizing of Multiple Active Power Filters

  • Moradifar, Amir;Soleymanpour, Hassan Rezai
    • Journal of Power Electronics
    • /
    • 제12권5호
    • /
    • pp.830-841
    • /
    • 2012
  • Active power filters (APF) can be employed for harmonic compensation in power systems. In this paper, a fuzzy based method is proposed for identification of probable APF nodes of a radial distribution system. The modified adaptive particle swarm optimization (MAPSO) technique is used for final selection of the APFs size. A combination of Fuzzy-MAPSO method is implemented to determine the optimal allocation and size of APFs. New fuzzy membership functions are formulated where the harmonic current membership is an exponential function of the nodal injecting harmonic current. Harmonic voltage membership has been formulated as a function of the node harmonic voltage. The product operator shows better performance than the AND operator because all harmonics are considered in computing membership function. For evaluating the proposed method, it has been applied to the 5-bus and 18-bus test systems, respectively, which the results appear satisfactorily. The proposed membership functions are new at the APF placement problem so that weighting factors can be changed proportional to objective function.

반복제어기를 적용한 Active Power Decoupling 회로를 갖는 Boost Type PFC 정류기 (Boost Type PFC Rectifier with Active Power Decoupling Circuit with Repetitive Controller)

  • 황덕환;이정용;조영훈;최규하
    • 전력전자학회논문지
    • /
    • 제23권6호
    • /
    • pp.389-396
    • /
    • 2018
  • This study proposes a control method using a repetitive controller for a boost-type PFC rectifier with an APD circuit structure to improve the current distortion caused by DCM condition. Conventional proportional integral controllers have bandwidth limitations in DCM conditions. The performance improvement of the APD controller in the DCM region is verified through simulations and experiments on the compensation of harmonics by the repetitive controller.

Optimal Coordination of Intermittent Distributed Generation with Probabilistic Power Flow

  • Xing, Haijun;Cheng, Haozhong;Zhang, Yi
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권6호
    • /
    • pp.2211-2220
    • /
    • 2015
  • This paper analyzes multiple active management (AM) techniques of active distribution network (ADN), and proposes an optimal coordination model of intermittent distributed generation (IDG) accommodation considering the timing characteristic of load and IDG. The objective of the model is to maximize the daily amount of IDG accommodation under the uncertainties of IDG and load. Various active management techniques such as IDG curtailment, on-load tap changer (OLTC) tap adjusting, voltage regulator (VR) tap adjusting, shunt capacitors compensation and so on are fully considered. Genetic algorithm and Primal-Dual Interior Point Method (PDIPM) is used for the model solving. Point estimate method is used to simulate the uncertainties. Different scenarios are selected for the IDG accommodation capability investigation under different active management schemes. Finally a modified IEEE 123 case is used to testify the proposed accommodation model, the results show that the active management can largely increase the IDG accommodation and penetration.

교류전력 불평형 보상장치용 모델예측기반 전류제어 연구 (A Study on a Current Control Based on Model Prediction for AC Electric Railway Inbalance Compensation Device)

  • 이정현;조종민;신창훈;이태훈;차한주
    • 전력전자학회논문지
    • /
    • 제25권6호
    • /
    • pp.490-495
    • /
    • 2020
  • The power loss of large-capacity systems using single-phase inverters has attracted considerable attention. In this study, optimal switching sequence model prediction control at a low switching frequency is proposed to reduce the power loss in a high-power inverter system, and a compensation method that can be utilized for model prediction control is developed to reduce errors in accordance with sampling values. When a three-level, single-phase inverter using a switching frequency of 600 Hz and a sampling frequency of 12 kHz is adopted, the power factor is improved from 0.95 to 0.99 through 3 kW active power control. The performance of the controller is also verified.