• 제목/요약/키워드: active and reactive power control

검색결과 286건 처리시간 0.027초

PSS 튜닝을 위한 기본 연구 Part I : 계통 운전조건에 대한 토오크 특성분석 (A Basic Study for Tuning Power System Stabilizer Part I : Analyzing the Torque Characteristics of Power System Corresponding to Operating Conditions)

  • 김동준;문영환;김태균
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권9호
    • /
    • pp.1064-1072
    • /
    • 1999
  • The basic concepts, which are related to the PSS tuning conditions and performance conditions for the safe of determination of PSS gain and compensation of phasor lagging, are thoroughly investigated in this first part. The performance conditions, where the power system has the lowest inherent damping torque and PSS should provide maximum damping torque, are examined by analysing synchronizing torque and damping torque supplied by the voltage control loop at the oscillation frequency. PSS tuning conditions are also investigated by observing the phasor lagging and the gain, resulted from power system-generator-excitation system depending on operating conditions, such as generator active power, reactive power, transmission impedance and AVR gain. The basic concepts developed in this PartImake it possible to lay foundation for the discussion of PSS tuning in Part II.

  • PDF

Islanding Detection for PV System Connected to a Utility Grid

  • Han, Seok-Woo;Mok, Hyung-Soo;Choe, Gyu-Ha
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.719-723
    • /
    • 1998
  • Prevention of the islanding phenomena is one of the most important issues because it can damage electrical equipment connected to the utility system and endanger human life. It is very difficult to detect an islanding condition of a power distribution line with conventional voltage of frequency relays, while the output power and the load power of utility interactive PV inverter units are in nearly balanced state in both active power and reactive power. This paper describes the protective equipment that prevents the PV system connected to the utility grid from starting islanding. Both predictive ocntrol method and harmonic injection method are used for a current control and islanding detection for operating safety.

  • PDF

이중여자 유도발전기에 의한 가변속 풍력 발전시스템의 동특성 해석 (Dynamic Analysis of Variable Speed Wind Power Systems with Doubly-Fed Induction Generators)

  • 최장영;장석명
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권6호
    • /
    • pp.325-336
    • /
    • 2006
  • This paper deals with the dynamic analysis of variable speed wind power systems with doubly-fed induction generators (DFIG). First, the mathematical modeling of wind farm which consists of turbine rotor, DFIG, rotor side and grid side converter and control systems is presented. In particular, the equation for dynamic modeling of the DFIG and the AC/DC/AC converter is expressed as dq reference frame. And then, on the basis of mathematical modeling for each component of wind farm, dynamic simulation algorithms for speed and pitch angle control of wind turbine and generated active and reactive power control of the DFIG and the AC/DC/AC converter are established. Finally, Using the MATLAB/SIMULINK, this paper presents dynamic simulation model for 6MW wind power generation systems with the DFIG considering distribution systems and performs the dynamic analysis of wind power systems in steady state. Moreover, this paper also presents the dynamic performance for the case when the voltage sag in grid source and phase fault in bus are occurred.

연계계통에서 안전도제약을 고려한 최적전력조류 (Optimal Power Flow considering Security in Interconnected Power Systems)

  • 김규호;이재규;이상봉;유석구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.194-196
    • /
    • 2001
  • This paper presents a hybrid algorithm for solving security constrained OPF in interconnected power systems, which is based on the combined application of evolutionary programming (EP) and sequential quadratic programming (SQP). The objective functions are the minimization of generation fuel costs and system power losses. In OPF considering security, the outages are selected by contingency ranking method. The control variables are the active power of the generating units, the voltage magnitude of the generator, transformer tap settings and SVC setting. The state variables are the bus voltage magnitude, the reactive power of the generating unit, line flows and the tie line flow. The method proposed is applied to the modified IEEE 14buses model system.

  • PDF

STATCOM에서 영상분 전류주입에 의한 셀간 전압평형화 제어의 향상 (Enhancement of Cell Voltage Balancing Control by Zero Sequence Current Injection in a Cascaded H-Bridge STATCOM)

  • 권병기;정승기;김태형
    • 전력전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.321-329
    • /
    • 2015
  • The static synchronous compensator (STATCOM) of cascaded H-bridge configuration accompanying multiple separate DC sides is inherently subject to the problem of uneven DC voltages. These DC voltages in one leg can be controlled by adjusting the AC-side output voltage of each cell inverter, which is proportional to the active power. However, when the phase current is extremely small, large AC-side voltage is required to generate the active power to balance the cell voltages. In this study, an alternative zero-sequence current injection method is proposed, which facilitates effective cell balancing controllers at no load, and has no effect on the power grid because the injected zero sequence current only flows within the STATCOM delta circuit. The performance of the proposed method is verified through simulation and experiments.

영구자석동기발전기 풍력시스템의 하드웨어 시뮬레이터 개발 (Development of Hardware Simulator for PMSG Wind Power System)

  • 이두영;윤동진;정종규;양승철;한병문;송승호
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.951-958
    • /
    • 2008
  • This paper describes development of hardware simulator for the PMSG wind power system, which was designed considering wind characteristic, blade characteristic and blade inertia compensation. The simulator consists of three major parts, such as wind turbine model using induction motor, PMSG generator, converter-inverter set. and control system. The turbine simulator generates torque and speed signals for a specific wind turbine with respect to given wind speed. This torque and speed signals are scaled down to fit the input of 2kW PMSG. The PMSG-side converter operates to track the maximum power point, and the grid-side inverter controls the active and reactive power supplied to the grid. The operational feasibility was verified by computer simulations with PSCAD/EMTDC, and the implementation feasibility was confirmed through experimental works with a hardware set-up.

배전선로의 고조파 성분억제가 가능한 단위역률 전력변환기 개발에 관한 연구 (A Study on the Unity Power Factor Converter to Inhibit Harmonics of Distributed Line)

  • 박성준;변영복;권순재;김철우
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권5호
    • /
    • pp.57-63
    • /
    • 1995
  • 본 연구는 상전류가 상전압과 동위상에 가까운 정현파가 되도록 제어함으로써 배전선로의 고조파성분과 무효전력을 감소시킬 수 있는 3상 PWM AC/DC승압형 콘버터를 해석하고 안정된 제어방법을 제안하였다. 제어기의 실현에 있어서는 전류센서가 없는 순시전압 제어방식의 비교적 간단한 제어알고리즘을 도출하였고 순시전압 제어는 PWM방식을 아용하였다. 또한 스위칭손실을 줄이기 위하여 스위칭 주파수는 비교적 낮은 범위인 3[kHz]정도로 하였다. 부하가 능동부하일 경우 전원쪽으로 잉여전력의 회수가 가능한 4상한 동작 콘버터를 구성하였으며, 본 제어방식의 타당성을 시뮬레이션 및 실험을 통하여 확인 하였다.

  • PDF

A Coordinative Control Strategy for Power Electronic Transformer Based Battery Energy Storage Systems

  • Sun, Yuwei;Liu, Jiaomin;Li, Yonggang;Fu, Chao;Wang, Yi
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1625-1636
    • /
    • 2017
  • A power electronic transformer (PET) based on the cascaded H-bridge (CHB) and the isolated bidirectional DC/DC converter (IBDC) is capable of accommodating a large scale battery energy storage system (BESS) in the medium-voltage grid, and is referred to as a power electronic transformer based battery energy storage system (PET-BESS). This paper investigates the PET-BESS and proposes a coordinative control strategy for it. In the proposed method, the CHB controls the power flow and the battery state-of-charge (SOC) balancing, while the IBDC maintains the dc-link voltages with feedforward implementation of the power reference and the switch status of the CHB. State-feedback and linear quadratic Riccati (LQR) methods have been adopted in the CHB to control the grid current, active power and reactive power. A hybrid PWM modulating method is utilized to achieve SOC balancing, where battery SOC sorting is involved. The feedforward path of the power reference and the CHB switch status substantially reduces the dc-link voltage fluctuations under dynamic power variations. The effectiveness of the proposed control has been verified both by simulation and experimental results. The performance of the PET-BESS under bidirectional power flow has been improved, and the battery SOC values have been adjusted to converge.

An Integrated Compensation Algorithm for PCC Voltage Fluctuation and Unbalance with Variable Limit of Positive and Negative Sequence Currents

  • Im, Ji-Hoon;Song, Seung-Ho;Cho, Sung-Min
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.751-760
    • /
    • 2017
  • This paper proposes a point of common coupling (PCC) voltage compensation algorithm using a current limitation strategy for use in distributed generation (DG). The proposed strategy maintains the PCC voltage by prioritizing currents when an output current reference is larger than the current capacity of the power condition system (PCS) of the DG. With this strategy, the DG outputs the active current, reactive current, and the negative sequence current. The DG uses the reactive current for maintaining the PCC voltage within a normal range; the negative sequence current is used for reducing the PCC voltage unbalance. The proposed method was verified using PSIM simulation and experimental results.

영구자석형 동기발전기를 이용한 풍력단지의 플리커 저감 (Flicker Mitigation in a Wind Farm by Controlling a Permanent Magnet Synchronous Generator)

  • 팜반호안;김대현;안진홍;김일환;오성보;김호찬;김세호
    • 제어로봇시스템학회논문지
    • /
    • 제15권12호
    • /
    • pp.1163-1168
    • /
    • 2009
  • The power quality of wind energy becomes more and more important in connecting wind-farms to the grid, especially weak grid. This paper presents the simulation of a wind farm of a permanent magnet synchronous generator (PMSG) and a doubly fed induction generator (DFIG). Flicker mitigation is performed by using PMSG as a static synchronous compensator (STATCOM) to regulate the voltage at the point of common coupling (PCC). A benefit of the measure is that integrating two function of to control the active power flow and to reduce the voltage flicker in a wind farm. Simulation results show that controlling PMSG is an effective and economic measure in reducing the flicker during continuous operation of grid connected wind turbines regardless of short circuit capacity ratio, turbulence intensity and grid impedance angle.