• 제목/요약/키워드: acrylic resins

검색결과 135건 처리시간 0.033초

Evaluation of Color Stability according to Shade of Temporary Crown Resin Using Digital Spectrophotometer: In Vitro Study

  • Ku, Hye-min;Jun, Mi-Kyoung
    • 치위생과학회지
    • /
    • 제22권3호
    • /
    • pp.139-147
    • /
    • 2022
  • Background: Temporary crown resins are used prior to prosthesis placement, indicating the importance of aesthetics. The aim of this study was evaluate the color stability of various staining solutions according to the color of temporary crown resins using VITA Easyshade V. Methods: The temporary crowns used were the powder-liquid type and included four shades. A total of 36 specimens were fabricated in the form of disks with a diameter of 1.8 mm and a depth of 2 mm. They were divided into four groups of nine each, and staining was performed for seven days by precipitation in 3 mL of three staining solutions composed of distilled water, black coffee, and red wine. Color and color stability evaluations were performed by a trained examiner using a digital spectrophotometer (VITA Easyshade V). Color stability was analyzed using the ΔE value. Results: Because of the color stability evaluation using the ΔE value, the difference between three and seven days was significant in the specimen I and III groups (p<0.05). Further, post hoc analysis showed that the ΔE value of red wine was significant, indicating that the color stability in red wine was low. The ΔE values in group II between days three and seven were statistically significant (p<0.05). Post hoc analysis showed that distilled water, coffee, and wine had the highest ΔE values on day three. On day seven, the ΔE value for wine was significant, and the color stability was low. There was no significant difference in group IV according to the staining period and staining solution; therefore, color stability was high (p>0.05). Conclusion: This study showed that most temporary resin restorations exhibited color stability in the staining solution. The darker the color of the temporary resin restoration, the higher the color stability against extrinsic staining.

Influence of various metal oxides on mechanical and physical properties of heat-cured polymethyl methacrylate denture base resins

  • Asar, Neset Volkan;Albayrak, Hamdi;Korkmaz, Turan;Turkyilmaz, Ilser
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.241-247
    • /
    • 2013
  • PURPOSE. To evaluate the effect of various metal oxides on impact strength (IS), fracture toughness (FT), water sorption (WSP) and solubility (WSL) of heat-cured acrylic resin. MATERIALS AND METHODS. Fifty acrylic resin specimens were fabricated for each test and divided into five groups. Group 1 was the control group and Group 2, 3, 4 and 5 (test groups) included a mixture of 1% $TiO_2$ and 1% $ZrO_2$, 2% $Al_2O_3$, 2% $TiO_2$, and 2% $ZrO_2$ by volume, respectively. Rectangular unnotched specimens ($50mm{\times}6.0mm{\times}4.0mm$) were fabricated and drop-tower impact testing machine was used to determine IS. For FT, compact test specimens were fabricated and tests were done with a universal testing machine with a cross-head speed of 5 mm/min. For WSP and WSL, disc-shaped specimens were fabricated and tests were performed in accordance to ISO 1567. ANOVA and Kruskal-Wallis tests were used for statistical analyses. RESULTS. IS and FT values were significantly higher and WSP and WSL values were significantly lower in test groups than in control group (P<.05). Group 5 had significantly higher IS and FT values and significantly lower WSP values than other groups (P<.05) and provided 40% and 30% increase in IS and FT, respectively, compared to control group. Significantly lower WSL values were detected for Group 2 and 5 (P<.05). CONCLUSION. Modification of heat-cured acrylic resin with metal oxides, especially with $ZrO_2$, may be useful in preventing denture fractures and undesirable physical changes resulting from oral fluids clinically.

교착제 종류에 따른 단청의 도막 성능 (Effect of Vehicle Resin on Coating Performance of Dan-Chung)

  • 한규성;신수정
    • Journal of the Korean Wood Science and Technology
    • /
    • 제35권1호
    • /
    • pp.44-50
    • /
    • 2007
  • 교착제의 종류가 단청의 도막성능에 미치는 효과를 구명하고자, 전통적으로 사용되어 온 녹말풀과 아교, 그리고 최근에 사용되기 시작한 수성아크릴수지 에멀젼에 대하여 검토하였다. 촉진열화시험과 옥외폭로시험을 실시한 후 색상의 변화와 도막 박리 특성 및 도막부착력을 조사한 결과, 수성아크릴수지 에멀젼을 교착제로 사용한 단청은 촉진열화시험과 옥외폭로시험에서도 전혀 도막박리가 발생하지 않았으며, 수성아크릴수지 에멀젼이 매우 우수한 도막성능을 부여하는 것으로 밝혀졌다. 자외선에 의한 단청의 색상변화는 수성아크릴수지 에멀젼을 교착제로 사용한 경우 가장 적었으며, 아교를 교착제로 사용한 경우 가장 컸다. 아교밑칠은 아교를 교착제로 사용할 경우에는 단청 도막의 부착력을 크게 향상시키지만, 수성아크릴수지 에멀젼을 교착제로 사용할 경우에는 오히려 도막부착력을 저하시켰다.

STRAIN AND TEMPERATURE CHANGES DURING THE POLYMERIZATION OF AUTOPOLYMERIZING ACRYLIC RESINS

  • Ahn Hyung-Jun;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.709-734
    • /
    • 2001
  • The aims of this experiment were to investigate the strain and temperature changes simultaneously within autopolymerzing acrylic resin specimens. A computerized data acquisition system with an electrical resistance strain gauge and a thermocouple was used over time periods up to 180 minutes. The overall strain kinetics, the effects of stress relaxation and additional heat supply during the polymerization were evaluated. Stone mold replicas with an inner butt-joint rectangular cavity ($40.0{\times}25.0mm$, 5.0mm in depth) were duplicated from a brass master mold. A strain gauge (AE-11-S50N-120-EC, CAS Inc., Korea) and a thermocouple were installed within the cavity, which had been connected to a personal computer and a precision signal conditioning amplifier (DA1600 Dynamic Strain Amplifier, CAS Inc., Korea) so that real-time recordings of both polymerization-induced strain and temperature changes were performed. After each of fresh resin mixture was poured into the mold replica, data recording was done up to 180 minutes with three-second interval. Each of two poly(methyl methacrylate) products (Duralay, Vertex) and a vinyl ethyl methacrylate product (Snap) was examined repeatedly ten times. Additionally, removal procedures were done after 15, 30 and 60 minutes from the start of mixing to evaluate the effect of stress relaxation after deflasking. Six specimens for each of nine conditions were examined. After removal from the mold, the specimen continued bench-curing up to 180 minutes. Using a waterbath (Hanau Junior Curing Unit, Model No.76-0, Teledyne Hanau, New York, U.S.A.) with its temperature control maintained at $50^{\circ}C$, heat-soaking procedures with two different durations (15 and 45 minutes) were done to evaluate the effect of additional heat supply on the strain and temperature changes within the specimen during the polymerization. Five specimens for each of six conditions were examined. Within the parameters of this study the following results were drawn: 1. The mean shrinkage strains reached $-3095{\mu}{\epsilon},\;-1796{\mu}{\epsilon}$ and $-2959{\mu}{\epsilon}$ for Duralay, Snap and Vertex, respectively. The mean maximum temperature rise reached $56.7^{\circ}C,\;41.3^{\circ}C$ and $56.1^{\circ}C$ for Duralay, Snap, and Vertex, respectively. A vinyl ethyl methacrylate product (Snap) showed significantly less polymerization shrinkage strain (p<0.01) and significantly lower maximum temperature rise (p<0.01) than the other two poly(methyl methacrylate) products (Duralay, Vertex). 2. Mean maximum shrinkage rate for each resin was calculated to $-31.8{\mu}{\epsilon}/sec,\;-15.9{\mu}{\epsilon}/sec$ and $-31.8{\mu}{\epsilon}/sec$ for Duralay, Snap and Vertex, respectively. Snap showed significantly lower maximum shrinkage rate than Duralay and Vertex (p<0.01). 3. From the second experiment, some expansion was observed immediately after removal of specimen from the mold, and the amount of expansion increased as the removal time was delayed. For each removal time, Snap showed significantly less strain changes than the other two poly(methyl methacrylate) products (p<0.05). 4. During the external heat supply for the resins, higher maximum temperature rises were found. Meanwhile, the maximum shrinkage rates were not different from those of room temperature polymerizations. 5. From the third experiment, the external heat supply for the resins during polymerization could temporarily decrease or even reverse shrinkage strains of each material. But, shrinkage re-occurred in the linear nature after completion of heat supply. 6. Linear thermal expansion coefficients obtained from the end of heat supply continuing for an additional 5 minutes, showed that Snap exhibited significantly lower values than the other two poly(methyl methacrylate) products (p<0.01). Moreover, little difference was found between the mean linear thermal expansion coefficients obtained from two different heating durations (p>0.05).

  • PDF

도재표면처리제가 복합레진과 도재와의 결합에 미치는 영향 (THE EFFECTS OF PORCELAIN PRIMERS ON THE BONDING OF COMPOSITE RESINS TO PORCELAIN)

  • 백명주;박주미;배태성;박찬운
    • 대한치과보철학회지
    • /
    • 제30권1호
    • /
    • pp.55-64
    • /
    • 1992
  • This study investigated the effect of porcelain primer on bonding of coomposite resin to porcelain surface. In order to test the bond strength between porcelain and composite resin, porcelain cylinders were embedded in acrylic resin, and polished with 240grit silicone caqrbide paper. The specimens were divided into twelve groups. All specimens were treated with three porcelain primers and bonded with five composite resins. All test groups were stored in $37^{\circ}C$ distilled water for 48hours. Shear bond strengths were measured with Instron(Model 4201) at a cross-head speed of 1mm/min. The obtained results were as follows : 1. Scotchprime/Silux II group and BISCO Porcelain Primer/Bisfill group showed significant higher bond strengths than Clearfil Porcelain Primer/photo Clearfil Bright group(p<0.05). And there was no significant differences in bond strengths between Scotchprime/Silux II group and BISCO Porcelain Primer/Bisfill group(p>0.05). 2. When composite resins were used with Scotchprime, the bond strengths were decresed Silux II$(16.68{\pm}3.35MPa)$, Bisfil$(16.23{\pm}4.54MPa)$, Poly-Fill$(14.74{\pm}4.08MPa)$, Photo Clearfil Bright$(13.75{\pm}2.89MPa)$ and Pekalux$(14.74{\pm}4.08MPa)$ in order, but there was no statistical significance(p>0.05). 3. When composite resins were used with BISCO Porcelain Primer, the bond strength were decreased Bisfil$(16.17{\pm}1.60MPa)$, Silux II$(12.13{\pm}2.37MPa)$, Poly-Fill$(10.78{\pm}1.99MPa)$, Photo Cleafil Bright $(9.91{\pm}4.59MPa)$ and Pekalux$(7.36{\pm}2.16MPa)$ in order, but there was no statistical significance(p>0.05). 4. Silux II, Photo Clearfil Bright and Poly-Fill used with Scotchprime showed significant higher bond strengths than BISCO Porcelain Primer(p>0.05).

  • PDF

친유성 아크릴 수지로 처리된 폴리프로필렌 편직물의 유흡착 성질 (Oil Absorptive Properties of Polypropylene Knit Fabric Treated with Oleophilic Acrylic Resin)

  • 정화진
    • 한국산학기술학회논문지
    • /
    • 제17권2호
    • /
    • pp.528-535
    • /
    • 2016
  • Ethyl acrylate(EA) 혹은 lauryl acrylate(LA)와 hydroxy ethyl acrylate(HEA)를 용액중합법에 의해 공중합하여 2종의 친유성 아크릴 전구중합체를 얻은 다음, 여기에 가교제로서 hexamethylene diisocyanate(HDI)를 첨가 배합하여, 폴리프로필렌 velvet 편직물에 통상의 pad-dry-cure방법으로 수지가공을 실시하여 유흡착재를 제조하였다. 가교 아크릴 수지(EA-HEA-HDI)의 겔화도는 전체 acrylate에 대한 HEA의 사용량과 가교제인 HDI의 농도가 증가할수록 증가하였다. 얻어진 유흡착재의 수지 부착율에 따른 흡유능과 유보유율은 시험유로서 n-decane, toluene, 대두유, 윤활유, 벙커C유를 사용하여 평가 하였고 대두유를 제외하고 사용된 모든 오일에 걸쳐 흡유능에 미치는 최적의 부착율은 약 6%로 나타났다. 한편 유보유율은 부착율의 증가에 따라 증가하였고 더욱이 고비중, 고점도 오일의 경우에서 전반적으로 보다 증가된 값을 나타내었다. 또한 흡유능은 LA-HEA-HDI로 처리된 유흡착재가 EA-HEA-HDI의 그것에 비하여 높았으며, 아크릴 수지의 측쇄 알킬기의 길이가 증가할수록 보다 높은 흡유능을 나타내었다.

고흡수성 수지를 이용한 흡수성 실리콘의 특성 연구 (Study on the Characteristics of the Absorbency Silicone by Super Absorbent Polymers)

  • 차국찬;송점식;이석민
    • Elastomers and Composites
    • /
    • 제47권2호
    • /
    • pp.141-147
    • /
    • 2012
  • 실리콘 수지는 소수성이 강한 고분자이기 때문에 수분을 흡수하는 기능이 전혀 없다. 하지만 고흡수성 수지(Super Absorbent Polymer)를 첨가제로 사용하면 기존의 실리콘보다 월등한 흡수성을 갖게 된다. 본 연구에서는 무정형 형태의 입자 크기가 다른 아크릴계 고흡수성 수지 3가지를 선택하여 배합비를 설정하고 2액형 타입의 의료용 실리콘 소재에 적용해서 수분을 흡수하는 기능을 갖는 새로운 실리콘 소재를 개발하였다. 고흡수성 수지의 첨가에 의한 실리콘 수지의 제조시 입자 사이즈와 함량을 달리하면서 인장, 인열, 압축, 경도에 대한 기계적 물성 변화를 알아보았으며, 시간에 따른 실리콘 수지의 흡수성을 측정하였다. 또한 전자 현미경을 통해 고흡수성 수지의 입자형태와 실리콘 수지와의 분포도를 관찰하였다.

Can prosthetic limbs made too quickly cause kidney damage?: a pilot study

  • Petrofsky, Jerrold S.;Browne, Mary;Jamshidi, Mahyar;Libo-on, Anthony;Lee, Haneul
    • Physical Therapy Rehabilitation Science
    • /
    • 제3권2호
    • /
    • pp.119-124
    • /
    • 2014
  • Objective: The use of chemicals for building prosthetic sockets present the possibility of being hazardous and unsafe due to off-gassing. The purpose of the present study was to investigate if freshly made materials used in prosthetic sockets causes off-gassing that would penetrate the skin and cause damage to the kidneys or blood. Design: Cross-sectional study. Methods: In this research, the off-gassing effects during the initial curing process of styrene monomer, vinyl ester resin, epoxy methacrylate resin, benzene-1, 3-dimethaneamine, trimethylhexanedlamine, and paratertiarybutylphenol were analyzed. Acid detection strips were placed inside newly fabricated mock-prosthetic sockets and left overnight in a closed environment to find out if acid was present in the invisible fumes. The plastic was worn by 9 subjects and urinalysis was made after 48 hours to test for any kidney or blood toxicity of the resins. Results: After wearing the plastic cuff for 48 hours, the ratio of protein to creatinine in the urine was raised to an abnormal level in five out of nine subjects. Four out of the nine subjects showed normal protein to creatinine ratios after wearing the device. The results showed that damage to the kidney occurred from wearing the resins after curing in half of the subjects. Conclusions: It is very important to conduct patient intakes which includes the assessment of renal function. Off-gassing in vented chambers may be needed to protect both prosthetists and patients.

A comparative study on the accuracies of resin denture bases and metal denture bases

  • Park Hwee-Woong;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.250-259
    • /
    • 2001
  • Since the late 1930s, acrylic resins have been the materials of choice for the fabrication of complete denture bases. It has excellent esthetic properties, adequate strength, low water sorption, and low solubility. But acrylic resin has disadvantage of processing shrinkage that reduces denture retention and accuracy of denture occlusion. Metals also have been used in denture base material. Metals used in denture bases display excellent strength and dimensional stability. The major disadvantages associated with metal denture bases include increased cost, difficulty in fabrication, compromised esthetic qualities, and inability to re-base. The purpose of this study is to compare the artificial tooth movements of complete dentures with resin bases and metal bases after curing, deflasking, polishing immersion in water for 1 week and 4 weeks. Twenty-four maxillary complete resin denture bases with artificial teeth were fabricated. Twelve of them were resin based and other twelve of them were metal based. Fine crosses were marked on the incisal edges of right central incisors and distobuccal cusps of be second molars. Measurements were done for the changes of distances of reference points at the time of wax denture, after deflasking after decasting after polishing after immersion in water for 1 week and 4 weeks Meaurements were done to the accuracy of 0.001mm with a measuring microscope. The results were as follows : 1. Metal base showed significantly less tooth movement than resin base after curing and decasting (p<0.01). 2. Metal base showed significantly less tooth movement than resin base after polishing (p<0.01). 3. After immersion in water for 1 week and 4 weeks, metal base showed less movement than resin base. Difference was significant for anterior-posterior distances (p<0.01), but not significant for molar-to-molar distance (p>0.01). 4. 1 week and 4 weeks of immersion failed to compensate the initial processing shrinkage of metal and resin bases (p>0.01).

  • PDF

교정용 레진장치의 레진주입방법에 따른 기계적 특성 (Mechanical properties by resin injection method of orthdontic acrylic resin)

  • 조정기
    • 디지털융복합연구
    • /
    • 제18권4호
    • /
    • pp.341-346
    • /
    • 2020
  • 가철성 교정장치에서 주로 사용하고 있는 자가중합 레진인 Polymethyl methacrylate (PMMA)는 현대 치의학 분야에서 주로 쓰이고 있는 아크릴릭 레진이다. 장점으로 색과 체적의 조직 친화성, 안정성 등 있어 치과에선 교정장치 재료로 오랫동안 사용해 왔다. PMMA의 제작은 활성화 방법에 따라 자가중합방식과 열중합 방식으로 나눌 수 있다. 자가중합 레진은 치과 교정장치로 오래동안 사용되고 있다. 레진의 주입방법은 크게 적층법(sprinkle-on method)와 혼합법(mixing method)이 있다. 본 연구에서는 교정장치의 레진 주입방법에 따른 기계적 특성인 강도, 탄성계수 경도, 표면조도를 실험 해보고자 한다. Orthodontic PMMA 의 직사각형 시편 (1.4×3.0×19.0 mm)에 3점 굽힘강도 실험한 결과 강도에선 유의한 차이가 없었다. 경도 역시 유의한 차이가 없었다. 표면조도도 큰 차이가 보이지 않았다. Orthodontic PMMA는 교정용 장치의 레진주입 방식에 따른 기계적 특성의 유의한 차이가 없음을 확인하였다.