• Title/Summary/Keyword: acrylic

Search Result 1,832, Processing Time 0.026 seconds

A PHOTOELASTIC STRESS ANALYSIS IN MANDIBULAR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE DESIGNED UNILATERALLY WITH DIFFERENT DIRECT RETAINERS (편측성으로 설계된 하악 유리단 국소의치에서 직접유지장치의 설계 변화에 따른 광탄성 응력 분석에 관한 연구)

  • Son Hong-Suk;Kay Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.1
    • /
    • pp.25-42
    • /
    • 1992
  • The purpose of this study was to analyze the magnitude and distribution of stress using a photoelastic model from a unilateral distal extention removable partial dentures with five kinds of the direct retainers, that is, the bilaterally designed bar clasp of the cross-arch lingual bar and the unilaterally designed bar clasp, circumferential clasp, mini-Dalbo attachment, and telescope retainer. A photoelastic model for mandible was made of the epoxy resin(PL-1) and hardner (PLH-1) with the acrylic resin teeth used and was coated with plastic cement-1 at the lingual surface of the model, and then five kinds of removable partial dentures were set, A unilateral vertical load of about 16Kg was applied on the first molar and the stress pattern of the photoelastic model under each condition was analyzed by the reflective circular polariscope. The following results were obtained: 1. The conventional removable partial denture with the bilaterally cross arch lingual bar produced the most favorable stress distribution on the residual ridge and supporting structure of abutment teeth than the unilaterally designed removable partial dentures. 2. The unilaterally designed removable partial denture with the bar clasp produced the stress distribution on the residual ridge, except sligtly higher stress concentration on the supporting structure of the abutment teeth, similar to the conventional removable partial denture with the bilaterally designed cross arch lingual bar. 3. On the unilaterally designed removable partial dentures, the bar clasp produced greater stress distribution on the residual ridge and supporting structure of the abutment teeth than the circumferential clasp. 4. On the unilaterally designed removable partial dentures, the mimi-Dalbo attachment produced relatively higher stress concentration on the residual ridge, but produced lesser stress concentration on the supporting structure of the abutment teeth than the other direct retainers. 5. On the unilaterally designed removable partial dentures, the telescope retainer produced uniform stress distribution on the residual ridge, but produced higher stress concentration at the root apex of the terminal abutment tooth than the other direct retainers. 6. On the unilaterally designed removable partial dentures the circumferential clasp and telescope retainer produced slightly higher stress concentration on the residual ridge and supporting structure of the abutment teeth than the bar clasp and mini- Dalbo attachment.

  • PDF

THE EFFECTS OF PORCELAIN PRIMERS ON THE BONDING OF COMPOSITE RESINS TO PORCELAIN (도재표면처리제가 복합레진과 도재와의 결합에 미치는 영향)

  • Back Myung-Ju;Park Ju-Mi;Bae Tae-Seong;Park Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.1
    • /
    • pp.55-64
    • /
    • 1992
  • This study investigated the effect of porcelain primer on bonding of coomposite resin to porcelain surface. In order to test the bond strength between porcelain and composite resin, porcelain cylinders were embedded in acrylic resin, and polished with 240grit silicone caqrbide paper. The specimens were divided into twelve groups. All specimens were treated with three porcelain primers and bonded with five composite resins. All test groups were stored in $37^{\circ}C$ distilled water for 48hours. Shear bond strengths were measured with Instron(Model 4201) at a cross-head speed of 1mm/min. The obtained results were as follows : 1. Scotchprime/Silux II group and BISCO Porcelain Primer/Bisfill group showed significant higher bond strengths than Clearfil Porcelain Primer/photo Clearfil Bright group(p<0.05). And there was no significant differences in bond strengths between Scotchprime/Silux II group and BISCO Porcelain Primer/Bisfill group(p>0.05). 2. When composite resins were used with Scotchprime, the bond strengths were decresed Silux II$(16.68{\pm}3.35MPa)$, Bisfil$(16.23{\pm}4.54MPa)$, Poly-Fill$(14.74{\pm}4.08MPa)$, Photo Clearfil Bright$(13.75{\pm}2.89MPa)$ and Pekalux$(14.74{\pm}4.08MPa)$ in order, but there was no statistical significance(p>0.05). 3. When composite resins were used with BISCO Porcelain Primer, the bond strength were decreased Bisfil$(16.17{\pm}1.60MPa)$, Silux II$(12.13{\pm}2.37MPa)$, Poly-Fill$(10.78{\pm}1.99MPa)$, Photo Cleafil Bright $(9.91{\pm}4.59MPa)$ and Pekalux$(7.36{\pm}2.16MPa)$ in order, but there was no statistical significance(p>0.05). 4. Silux II, Photo Clearfil Bright and Poly-Fill used with Scotchprime showed significant higher bond strengths than BISCO Porcelain Primer(p>0.05).

  • PDF

A STUDY ON THE BOND STRENGH OF 4-META ACRYLIC RESIN DENTURE BASE TO COBALT-CHROMIUM ALLOYS (4-META의치상레진과 Cobalt-Chromium계 합금의 접착강도에 관한 연구)

  • Sung, Moo Gyung;Kim, Kwang Nam;Chang, Ik Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.29-51
    • /
    • 1990
  • This study was designed to compre the tensile bond strength of 4-META containging denture base resin to Co-Cr alloys after various surface treatments. Especially the surface treatment of sandblasting the mental with aluminum oxide and treating in oxidizing solution composed of 3% aqueous sulfuric acid with 1% potassium manganate were compared. Effect of surface roughness on bonding was measured after sandblasting with 50um, 300um aluminun oxide and polishing with emery pater. Also the effects of wax and wax solvent on bonding were observed. According to the type of polymerization process, heat-cured Meta-Dent resin and autopolymerizing Meta-Fast resin were used. For some specimnens, the tensile bond strength were measured agter three pre-conditions : 1day after bonding, immersed in water at $75^{\circ}C{\pm}3^{\circ}C$ for 4weeks, under normal ambient condition for 4weeks. The following results were obtained from this study : 1. The bond strengths of resins containing 4-META were significantly higher than those of conventional denture base resins(p<0.05). 2. Autopolymerizing Meta-Fast resin had higher bond strength than heat-cured Meta-Dent, resin(p<0.05). 3. The bond strengths of Biosil and Nobilium to 4-META containging resins were not significally different(p>0.05). 4. Stable adhesion can be achieved when mechanically roughen the metal surface by snadblasting with $50{\mu}m$ aluminum oxide than treating in an oxidizing soluing with potassium manganate(p<0.05). 5. Once the metal surface is contaminated with wax, the bond srtength decreased greatly in spite of wax wash with boiling water. But the bond strength recovered significantly with the use of wax solvent 6. Meta-Dent resin had higher bond strength when roughen the metal surface with $50{\mu}m$ aluminum oxide than with $300{\mu}m$ aluminum oxide(p<0.05). In case of Meta-Fast, resin, the use of $300{\mu}m$aluminum oxide was a little advantageous of bonding, but was statistically insignificant(p>0.05).

  • PDF

EFFECT OF ETCHING TIME ON ENAMEL SURFACE ROUGHNESS: CONFOCAL LASER SCANNING MICROSCOPIC STUDY (공초점 레이저주사현미경을 이용한 산부식 시간에 따른 법랑질 표면 양상에 관한 연구)

  • Kam, Dong-Hoon;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.41-46
    • /
    • 2003
  • In order to evaluate the sufficient etching time for successful bonding and also minimizing unnecessary mineral loss, the enamel surface roughness analysis was performed using confocal laser scanning microscopy. Sixty extracted sound human molar teeth were imbedded in the center of acrylic cylinder using self-curing clear resin exposing buccal surface, and then polished with series of SiC paper(220, 500, 800, 1000, 2000, 4000 grit). Each specimen was randomly assigned to six groups(N=10). 37% phosphoric acid was applied to the polished tooth surface for 10, 20, 30, 40, 50, 60 seconds respectively and washed with copious water. After the surface roughness analysis, five roughness parameters(Sa, Sq, Sz, Sdr, Ra) were statistically analysed by ANOVA and Duncan post hoc test. We found that the all five parameters had higher roughness value in 30 seconds etching time, especially parameter Sz showed the lowest value in 10 seconds etching time and the highest value in 30 seconds etching time compared with the other etching times(p<0.05).

  • PDF

Study of Acute Myelocytic Leukemia Patient Treatment That Used Total Skin Electron Beam (Total Skin Electron Beam을 이용한 급성 골수성 백혈병 환자 치료에 대한 연구)

  • Lee, Sang-Ryul;Kang, Min-Kyu;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.152-158
    • /
    • 2009
  • Total Skin Electron Beam Therapy (TSEBT) of linear accelerator has become use so as to be useful, 2~9 MeV of energy territories came to be used with mycosis fungoides and cutaneous lymphomas in the superficial lesion treatment which covers the major portion of the body. I treat a patient to Stanford technique in this study, and it is $60^{\circ}$ around the patients whom Stanford technique irradiated electronic beam to a linear accelerator in horizontal directions and there is a way a standard of TSEBT treat it to six located field (anterior, posterior, and four obliques) becoming. An each field does horizontally it and consist to beam of the two component which fitted the center to a suitable angle. a patient treats it to three dual field a day in order to make short treatment time. when a first day, we treat one dual field at anterior position and two dual field at posterior position. when the second day, treat one dual field at posterior position and two dual field at anterior position. Therefore, six dual field is finished in perfect periodic two days. we made cylindrical acrylic phantom, and I inserted a dosimeter film between phantom. in order to measure a dose distribution calculation before treat a patient, and a patient checked it in six field directions that got from a treatment. It is after that thermoluminescent dosimetry (TLD) as it uses Rando phantom and then measurement dose distribution in six field directions after attaching at chest, the right and left flank, a back after irradiation.

  • PDF

Low-Cost CAP-type TDR Exploration Techniques for Leak Detection (누수탐지를 위한 저비용 CAP형 TDR 탐사기법)

  • Kim, Jin Man;Choi, Bong Hyuck;Cho, Jin Woo;Cho, Won Beom
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1479-1487
    • /
    • 2013
  • The river levee collapse and flood damages are dramatically increased due to the floods which caused by abnormal weather nowadays. The counterplan like TDR(Time Domain Reflectometry) river levee leaking exploration technique is needed to that levee failure causes of levee failure such as levee failure by penetration, piping, inadequate levee materials selection, poor compaction are almost 52% of the failure. This research practiced various comparing experiments of existing TDR(probe and tube types) and developing CAP type TDR to evaluate acrylic small CAP mould and low-cost TDR levee leaking monitoring system which was used probe type TDR. As the result, evaluated TDR system had 20cm critical exploration performance which was a leaking exploration performance, The functional ratio of TDR exploration sensitivity of dry density was sensitive more than 3 times than dry density, and weathered granite soil foundation water contents(w)-dielectric constant(${\epsilon}$) corelation formula was suggested to measure functional ratio on developing cap type TDR system.

Comparison of Parallel and Fan-Beam Monochromatic X-Ray CT Using Synchrotron Radiation

  • Toyofuku, Fukai;Tokumori, Kenji;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.407-410
    • /
    • 2002
  • Monochromatic x-ray CT has several advantages over conventional CT, which utilizes bremsstrahlung white x-rays from an x-ray tube. There are several methods to produce such monochromatic x-rays. The most popular one is crystal diffraction monochromatization, which has been commonly used because of the fact that the energy spread is very narrow and the energy can be changed continuously. The alternative method is the use of fluorescent x-ray, which has several advantages such as large beam size and fast energy change. We have developed a parallel-beam and a fan-beam monochromatic x-ray CT, and compared some characteristics such as accuracy of CT numbers between those systems. The fan beam monochromatic x-rays were generated by irradiating target materials by incident white x-rays from a bending magnet beam line NE5 in 6.5 GeV Accumulation Ring at Tukuba. The parallel beam monochromatic x-rays were generated by using a silicon double crystal monochromator at the bending magnet beam line BL-20BM in Spring-8. A Cadmium telluride (CdTe) 256 channel array detector with 512mm sensitive width capable of operating at room temperature was used in the photon counting mode. A cylindrical phantom containing eight concentrations of gadolinium was used for the fan beam monochromatic x-ray CT system, while a phantom containing acetone, ethanol, acrylic and water was used for the parallel monochromatic x-ray CT system. The linear attenuation coefficients obtained from CT numbers of those monochromatic x-ray CT images were compared with theoretical values. They showed a good agreement within 3%. It was found that the quantitative measurement can be possible by using the fan beam monochromatic x-ray CT system as well as a parallel beam monochromatic X-ray CT system.

  • PDF

Inhibitory Effects of the Seed Extract of Myristicae Semen on the Proliferation of Human Tumor Cell Lines (II) (육두구 추출물의 암세포증식 저해 효과 (제 2보))

  • Lee, Jung-Won;Choi, Yeon-Hee;Yoo, Mi-Young;Choi, Sang-Un;Hong, Kyung-Sik;Lee, Byung-Hoi;Yon, Gyu-Hwan;Kim, Young-Sup;Kim, Young-Kyoon;Ryu, Shi-Yong
    • Korean Journal of Pharmacognosy
    • /
    • v.37 no.3
    • /
    • pp.206-211
    • /
    • 2006
  • The methanol extract from seed of Myristica fragrans (Myristicaceae) demonstrated a potent inhibition on the pro-liferation of cultured human tumor cells such as A549 (non small cell lung), SK-OV-3 (ovary), SK-MEL-2 (melanoma), XF498 (central nerve system) and HCT-15 (colon) in vitro. By the continuous effort to purify the active components responsible far the anti-proliferative effect on tumor cell lines, we have isolated eleven kinds of lignan components, i. e., safrole (1), machilin A (2), licarin B (3), macelignan (4), mere-dihydroguaiaretic acid (5), mγnstargenol A (6), methoxyeugenol (7), machilin F (8), licarin A (9), nectandrin B (10), and 2-(4-allyl-2,6-dimethoxyphenoxy)-1-(4-hydroxy-3-methoxyphenyl)propan-1-ol (11) together with a novel furan fatty acid, (E)-3-(3-methyl-5-pentylfuran-2-yl) acrylic acid (12) from seed extract of M. fragrans. Chemical structures of the isolated components (1-12) were established bγ the aid of NMR spectroscopic analyses, i. e., COSY HMQC and HMBC. Each of the Isolates demonstrated a potent inhibition on the proliferation of cultured human tumor cells such as A549 (non small cell lung), SK-OY-3 (ovary), SK-MEL-2 (melanoma) and HCT-15 (colon) in vitro.

Model Test for the Determination of Distances between Jet-fans and Analysis of Recirculation (제트팬 설치 간격과 재유입 현상 분석을 위한 모형실험)

  • Kweon, Oh-Sang;Yoon, Chan-Hoon;Yoon, Sung-Wook;Kim, Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.4
    • /
    • pp.335-344
    • /
    • 2006
  • The domestic standards which used the standards of Road Association of Japan standards presents the distances of between jet-fans by the caliber of jet-fan. However, the Permanent International Association of Road Congress (PIARC) encourages it to be ten times a diameter of the tunnel. The distance of jet-fans installed in bases of two standards differs as much as two times, as so the proper basis after analysis of internal air current is needed since such difference can lead to disadvantage for selection of ventilation configuration. Based on Froude modeling theory, 1/40 scale acrylic model of a tunnel (215mm in diameter and 6.9m in length) and jet-fan (26.3mm and 31.6mm in caliber) was made for the measurement of changes in pressure and velocity due to the extension of tunnel for analysis of internal air current. And we measured the changes in pressure of surroundings of a jet-fan for confirmation of recirculation due to the exterior airs when the jet-fan is on. The results of the model test show that internal air current was not influenced by the caliber of jet-fan and its changes in pressure and velocity were stable in the point where it was nine times of diameter of the tunnel. Also the recirculation when the jet-fan is on could be verified. According to such results, in the cases of installing jet-fan in tunnels, the distances between jet-fans needs to be more than nine times the diameter.

Effect of Surfactant Type on the Particle Size and Yield in Semi-Continuous Emulsion Polymerization of n-Butyl Acrylate/Methyl Metacrylate (반연속식 노말브틸-아크릴레이트/메틸메타-아크릴레이트 유화중합(1) : 폴리머 라텍스의 수율과 입자크기에 관한 계면활성제 종류의 영향)

  • Ko, Ki-Young;Kim, Sung-il;Kim, Chul-Ung;Hyung, Gi-Woo
    • Clean Technology
    • /
    • v.11 no.1
    • /
    • pp.1-12
    • /
    • 2005
  • In these studies, semibatch emulsion copolymerization of n-butyl acrylate (n-BA) as adhesive component and methyl metacrylate (MMA) as coagulant component was carried out in order to investigate the role of surfactant in aqueous phase for polymer cement. It was found that the particle size and concentration of final polymer are affected by surfactant type used. The effect of nonionic surfactants was shown in the decrease of polymer emulsion concentration and small emulsion particle in order of LE-50, NP-50 > CE-50, Tween 20 > TX-405 > Brij 35. In LE and NP (n=7-50) as nonionic surfactant, it could be obtained the stable polymer emulsion of 40% in aqueous phase with average particle size of 250-320 nm using over n=30. On the other hand, the effect of surfactant type in initial reactor charge was shown that when SDS as ionic surfactant was used, the polymer emulsion concentration was constant irrespective of the amount used, whereas CTAB as cationic surfactant and HN-100 as reactive surfactant were shown a tendency to the decrease of that. The effect surfactant type on final polymer particle size was shown in decrease by the order of SDS > CTAB > HN-100.

  • PDF