• Title/Summary/Keyword: acquisition

Search Result 7,124, Processing Time 0.044 seconds

Literature Review on Applying Digital Therapeutic Art Therapy for Adolescent Substance Addiction Treatment (청소년 마약류 중독 치료를 위한 디지털치료제 예술치료 적용을 위한 문헌연구)

  • Jiwon Kim;Daniel H. Byun
    • Trans-
    • /
    • v.16
    • /
    • pp.1-31
    • /
    • 2024
  • The advent of digital media has facilitated easy access for adolescents to environments conducive to the purchase of narcotics. In particular, there's an increasing trend in the purchase and consumption of narcotics mediated through Social Network Services (SNS) and messenger services. Adolescents, sensitive to such environments, are at risk of experiencing neurological and mental health issues due to narcotic addiction, increasing their exposure to criminal activities, hence necessitating national-level management and support. Consequently, the quest for sustainable treatment methods for adolescents exposed to narcotics emerges as a critical challenge. In the context of high relapse rates in narcotic addiction, the necessity for cost-effective and user-friendly treatment programs is emphasized. This study conducts a literature review aimed at utilizing digital platforms to create an environment where adolescents can voluntarily participate, focusing on the development of therapeutic content through art. Specifically, it reviews societal perceptions and treatment statuses of adolescent drug addiction, analyzes the impact of narcotic addiction on adolescent brain activity and cognitive function degradation, and explores approaches for developing digital therapeutics to promote the rehabilitation of the addicted brain through analysis of precedential case studies. Moreover, the study investigates the benefits that the integration of digital therapeutic approaches and art therapy can provide in the treatment process and proposes the possibility of enhancing therapeutic effects through various treatment programs such as drama therapy, music therapy, and art therapy. The application of art therapy methods is anticipated to offer positive effects in terms of tool expansion, diversification of expression, data acquisition, and motivation. Through such approaches, an enhancement in the effectiveness of treatments for adolescent narcotic addiction is anticipated. Overall, this study undertakes foundational research for the development of digital therapeutics and related applications, offering economically viable and sustainable treatment options in consideration of the societal context of adolescent narcotic addiction.

Context-Based Design and Its Application Effects in Science Classes (맥락을 중요시하는 과학 수업 전략의 개발 및 적용)

  • Jung, Suk-Jin;Shin, Young-Joon
    • Journal of Korean Elementary Science Education
    • /
    • v.43 no.1
    • /
    • pp.48-63
    • /
    • 2024
  • This study aims to develop a class procedure for the application of classrooms that value context and to conduct science classes using this procedure to examine the effects. Among various contexts related to scientific knowledge, the study develops a teaching procedure for designing classes that focus on the contexts of discovery and real life. After verifying the content validity of the context-based design and the program to which it was applied, a class was conducted, and the responses of the children were checked. The final draft of the lesson design completed after revision and supplementation is as follows: context-based design was presented in four stages, namely, presenting, exploring the context, adapting the context, and organizing (share and synthesizing; PEAS). The goal is to enable people to experience the overall flow of scientific knowledge instead of focusing on the acquisition of fragmentary knowledge by covering a wide range of topics from the social and historical contexts in which scientific knowledge was created to its use in real life. To aid in understanding the newly proposed class procedure and verifying its effectiveness, we developed a program by selecting the "My Fun Exploration," 2. Biology and Environment unit of the second semester of the fifth grade. The result indicated that the elementary science program that applied the context-centered design effectively improved the self-directed learning ability of students. In addition, the effect was especially notable in terms of intrinsic motivation. As the students experienced the contexts of discovery and real life related to scientific knowledge, they developed the desire to actively participate in science learning. As this becomes an essential condition for deriving active learning effects, a virtuous cycle in which meaningful learning can occur has been created. Based on the implications, developing programs that apply context-based design to various areas and contents will be possible.

Analysis of the Range Verification of Proton using PET-CT (Off-line PET-CT를 이용한 양성자치료에서의 Range 검증)

  • Jang, Joon Young;Hong, Gun Chul;Park, Sey Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.101-108
    • /
    • 2017
  • Purpose: The proton used in proton therapy has a characteristic of giving a small dose to the normal tissue in front of the tumor site while forming a Bragg peak at the cancer tissue site and giving up the maximum dose and disappearing immediately. It is very important to verify the proton arrival position. In this study, we used the off-line PET CT method to measure the distribution of positron emitted from nucleons such as 11C (half-life = 20 min), 150 (half-life = 2 min) and 13N The range and distal falloff point of the proton were verified by measurement. Materials and Methods: In the IEC 2001 Body Phantom, 37 mm, 28 mm, and 22 mm spheres were inserted. The phantom was filled with water to obtain a CT image for each sphere size. To verify the proton range and distal falloff points, As a treatment planning system, SOBP were set at 46 mm on 37 mm sphere, 37 mm on 28 mm, and 33 mm on 22 mm sphere for each sphere size. The proton was scanned in the same center with a single beam of Gantry 0 degree by the scanning method. The phantom was scanned using PET-CT equipment. In the PET-CT image acquisition method, 50 images were acquired per minute, four ROIs including the spheres in the phantom were set, and 10 images were reconstructed. The activity profile according to the depth was compared to the dose profile according to the sphere size established in the treatment plan Results: The PET-CT activity profile decreased rapidly at the distal falloff position in the 37 mm, 28 mm, and 22 mm spheres as well as the dose profile. However, in the SOBP section, which is a range for evaluating the range, the results in the proximal part of the activity profile are different from those of the dose profile, and the distal falloff position is compared with the proton therapy plan and PET-CT As a result, the maximum difference of 1.4 mm at the 50 % point of the Max dose, 1.1 mm at the 45 % point at the 28 mm sphere, and the difference at the 22 mm sphere at the maximum point of 1.2 mm were all less than 1.5 mm in the 37 mm sphere. Conclusion: To maximize the advantages of proton therapy, it is very important to verify the range of the proton beam. In this study, the proton range was confirmed by the SOBP and the distal falloff position of the proton beam using PET-CT. As a result, the difference of the distally falloff position between the activity distribution measured by PET-CT and the proton therapy plan was 1.4 mm, respectively. This may be used as a reference for the dose margin applied in the proton therapy plan.

  • PDF

The Role of NF-${\kappa}B$ in the TNF-$\alpha$-induced Apoptosis of Lung Cancer Cell Line (폐암세포주의 TNF-$\alpha$ 유발 apoptosis에서 NF-${\kappa}B$의 역할)

  • Kim, J.Y.;Lee, S.H.;HwangBo, B.;Lee, C.T.;Kim, O.H.;Han, S.K.;Shim, O.S.;Yoo, C.G.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.2
    • /
    • pp.166-179
    • /
    • 2000
  • Background: The main reason for the failure of anti-cancer chemotherapy is the build up of resistance by cancer cells to apoptosis. The activation of NF-${\kappa}B$ in many cancer cell lines is reported to be underlying mechanism behind the build up of resistance of cancer cells to apoptosis. However, this relationship varied depending on the cells used in the experiments. In this study, the role of NF-${\kappa}B$ activation in the TNF-$\alpha$-induced apoptosis in lung cancer cell line was evaluated. Methods: NCI-H157 cells were used in all experiments. Cells were exposed to a high dose of TNF-$\alpha$(20 ng/ml) for 24 or 48 hours with or without blocking NF-${\kappa}B$ activation. TNF-$\alpha$-induced activation of NF-${\kappa}B$ was inhibited either by overexpression of $I{\kappa}B{\alpha}$-super repressor($I{\kappa}B{\alpha}$-SR) or by pre-treatment with proteasome inhibitor. Cell viability and apoptosis were evaluated with MTT assay and Western blot analysis for PARP fragment, respectively. Results: Cell viability of NCI-H157 cells was not affected by TNF-$\alpha$ treatment alone; however, combined treatment with TNF-$\alpha$ and cycloheximide reduced cell viability significantly, indicating that resistance to TNF-$\alpha$ is mediated by the new proteins synthesized after TNF-$\alpha$ stimulation. To evaluate the role of NF-${\kappa}B$ in the transcription of anti-apoptotic proteins. delete NF-${\kappa}B$ activation was inhibited before TNF-$\alpha$ stimulation. as described above. $AD5I{\kappa}B{\alpha}$-SR-transduction inhibited TNF-$\alpha$-induced nuclear translocation of p65. TNF-$\alpha$-induced cell death and apoptosis increased after inhibition of TNF-$\alpha$-induced activation of NF-${\kappa}$ by methods. Conclusion: These results suggest that TNF-$\alpha$-induced activation of NF-${\kappa}B$ may be closely related to the acquisition of the resistance to TNF-$\alpha$-induced apoptosis in lung cancer cells. Therefore. blocking of NF-${\kappa}B$ pathway can be a useful therapeutic modality in the treatment of lung cancer.

  • PDF

The Evaluation of Difference according to Image Scan Duration in PET Scan using Short Half-Lived Radionuclide (단 반감기 핵종을 이용한 PET 검사 시 영상 획득 시간에 따른 정량성 평가)

  • Hong, Gun-Chul;Cha, Eun-Sun;Kwak, In-Suk;Lee, Hyuk;Park, Hoon;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.102-107
    • /
    • 2012
  • Purpose : Because of the rapid physical decay of the short half-lived radionuclide, counting of event for image is very limited. In this reason, long scan duration is applied for more accurate quantitative analysis in the relatively low sensitive examination. The aim of this study was to evaluate the difference according to scan duration and investigate the resonable scan duration using the radionuclide of 11C and 18F in PET scan. Materials and Methods : 1994-NEMA Phantom was filled with 11C of $30.08{\pm}4.22MBq$ and 18F of $40.08{\pm}8.29MBq$ diluted with distilled water. Dynamic images were acquired 20frames/1minute and static image was acquired for 20minutes with 11C. And dynamic images were acquired 20frames/2.5minutes and static image was acquired for 50minutes with 18F. All of data were applied with same reconstruction method and time decay correction. Region of interest (ROI) was set on the image, maximum radioactivity concentration (maxRC, kBq/mL) was compared. We compared maxRC with acquired dynamic image which was summed one bye one to increase the total scan duration. Results : maxRC over time of 11C was $3.85{\pm}0.45{\sim}5.15{\pm}0.50kBq/mL$ in dynamic image, and static image was $2.15{\pm}0.26kBq/mL$. In case of 18F, the maxRC was $9.09{\pm}0.42{\sim}9.48{\pm}0.31kBq/mL$ in dynamic image and $7.24{\pm}0.14kBq/mL$ in static. In summed image of 11C, as total scan duration was increased to 5, 10, 15, 20minutes, the maxRC were $2.47{\pm}0.4$, $2.22{\pm}0.37$, $2.08{\pm}0.42$, $1.95{\pm}0.55kBq/mL$ respectively. In case of 18F, the total scan duration was increased to 12.5, 25, 37.5, and 50minutes, the maxRC were $7.89{\pm}0.27$, $7.61{\pm}0.23$, $7.36{\pm}0.21$, $7.31{\pm}0.23kBq/mL$. Conclusion : As elapsed time was increased after completion of injection, the maxRC was increased by 33% and 4% in dynamic study of 11C and 18F respectively. Also the total scan duration was increased, the maxRC was reduced by 50% and 20% in summed image of 11C and 18F respectively. The percentage difference of each result is more larger in study using relatively shorter half-lived radionuclide. It appears that the accuracy of decay correction declined not only increment of scan duration but also increment of elapsed time from a starting point of acquisition. In study using 18F, there was no big difference so it's not necessary to consider error of quantitative evaluation according to elapsed time. It's recommended to apply additional decay correction method considering decay correction the error concerning elapsed time or to set the scan duration of static image less than 5minutes corresponding 25% of half life in study using shorter half-lived radionuclide as 11C.

  • PDF

The Consideration of the Region of Interest on $^{99m}Tc$-DMSA Renal Scan in Pediatric Hydronephrosis Patients (수신증을 진단 받은 소아 환자의 DMSA 신장 검사에서 정확한 관심영역 설정에 대한 고찰)

  • NamKoong, Hyuk;Lee, Dong-Hyuk;Oh, Shin-Hyun;Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.27-33
    • /
    • 2012
  • Purpose: Most of diagnosis in the pediatric hydronephrosis patients have been performed $^{99m}Tc$-DMSA renal scan. Then the region of interest (ROI) is set for comparative analysis of uptake ratio in left-right kidney after acquiring the image. But if the equipment set an automatic ROI, the ROI could include expanded renal pelvis due to hydronephrosis and the uptake ratio of left-right kidney will be incorrect result. Therefore this study compared both ROIs including expanded renal pelvis and excluding renal pelvis through experiment using normal kidney phantom and expanded renal pelvis phantom and suggested setting method of improved ROI. In addition, this study have been helped by readout doctor for investigate distinction radiopharmaceutical uptake between renal cortex and remained urine by expanded renal pelvis. Materials and Methods: The both of renal phantoms were filled with water and shacked with $^{99m}TcO_4$ 111 MBq. In order to describe the expanded renal pelvis, the five latex balloon were all filled with 10 mL water and each of balloon was mixed with $^{99m}TcO_4$ 18.5, 37, 55.5, 74, 92.5 MBq. And we made phantom with fixed $^{99m}TcO_4$activity of 37 MBq and mixed water 5, 10, 15, 20, 25 mL in each balloon. The left kidney was fixed its shape and the right kidney was modified like as hydronephrosis kidney by attached the latex balloons. And the acquiring counts were 2 million. After acquisition, we compared the image of ROI with Expanded renal pelvis and the image of ROI without renal pelvis for analyzing difference in the uptake ratio of left-right kidney and for reproducibility, set the ROI 5 times in the same images. Patients were injected $^{99m}Tc$-DMSA 1.5~1.9 MBq/kg and scanned 3 to 4 hours after injection. The each of 3 skillful radio technologists performed the comparing estimation by setting ROI. To determine statistical significance between two data, SPSS (ver. 17) Wilcoxon Signed Ranks Test was used. Results: As a result of renal phantom's experiment, we compared with average of counts Background (BKG) ratios in the setting of ROI including expanded renal pelvis and setting of excluding expanded renal pelvis. Therefore, they can obtain changed counts and changed ratios. Patient also can obtain same results. In addition, the radiopharmaceutical uptake in expanded renal pelvis was come out the remained urine that couldn't descend to ureter by the help of readout doctor. Conclusion: As above results, the case of setting ROI including expanded renal pelvis was more abnormally increasing uptake ratio than the case of setting ROI excluding expanded renal pelvis in analysis the uptake ratio in left-right kidney of hydronephrosis. Because of the work convenience and prompted analysis, the automatic ROI is generally used. But in case of the hydronephrosis study, we should set the manual ROI without expanded renal pelvis for an accurate observation of the uptake ratio of left-right kidney since the radiopharmaceutical uptake in expanded renal pelvis is the remained urine.

  • PDF

The Evaluation of Attenuation Difference and SUV According to Arm Position in Whole Body PET/CT (전신 PET/CT 검사에서 팔의 위치에 따른 감약 정도와 SUV 변화 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Purpose: For better PET imaging with accuracy the transmission scanning is inevitably required for attenuation correction. The attenuation is affected by condition of acquisition and patient position, consequently quantitative accuracy may be decreased in emission scan imaging. In this paper, the present study aims at providing the measurement for attenuation varying with the positions of the patient's arm in whole body PET/CT, further performing the comparative analysis over its SUV changes. Materials and Methods: NEMA 1994 PET phantom was filled with $^{18}F$-FDG and the concentration ratio of insert cylinder and background water fit to 4:1. Phantom images were acquired through emission scanning for 4min after conducting transmission scanning by using CT. In an attempt to acquire image at the state that the arm of the patient was positioned at the lower of ahead, image was acquired in away that two pieces of Teflon inserts were used additionally by fixing phantoms at both sides of phantom. The acquired imaged at a were reconstructed by applying the iterative reconstruction method (iteration: 2, subset: 28) as well as attenuation correction using the CT, and then VOI was drawn on each image plane so as to measure CT number and SUV and comparatively analyze axial uniformity (A.U=Standard deviation/Average SUV) of PET images. Results: It was found from the above phantom test that, when comparing two cases of whether Teflon insert was fixed or removed, the CT number of cylinder increased from -5.76 HU to 0 HU, while SUV decreased from 24.64 to 24.29 and A.U from 0.064 to 0.052. And the CT number of background water was identified to increase from -6.14 HU to -0.43 HU, whereas SUV decreased from 6.3 to 5.6 and A.U also decreased from 0.12 to 0.10. In addition, as for the patient image, CT number was verified to increase from 53.09 HU to 58.31 HU and SUV decreased from 24.96 to 21.81 when the patient's arm was positioned over the head rather than when it was lowered. Conclusion: When arms up protocol was applied, the SUV of phantom and patient image was decreased by 1.4% and 9.2% respectively. With the present study it was concluded that in case of PET/CT scanning against the whole body of a patient the position of patient's arm was not so much significant. Especially, the scanning under the condition that the arm is raised over to the head gives rise to more probability that the patient is likely to move due to long scanning time that causes the increase of uptake of $^{18}F$-FDG of brown fat at the shoulder part together with increased pain imposing to the shoulder and discomfort to a patient. As regarding consideration all of such factors, it could be rationally drawn that PET/CT scanning could be made with the arm of the subject lowered.

  • PDF

Evaluation of Usefulness and Procedures for Safety of Radiopharmaceuticals in Cisternography (Cisternography 검사 시 사용되는 방사성의약품의 안정성 확보를 위한 검사도입 및 유용성 평가)

  • Kim, Da-Eun;Yoo, Yeon-Wook;Choi, Ho-Yong;Kim, Yun-Cheol;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.45-49
    • /
    • 2010
  • Purpose: Several radiopharmaceuticals were used for cisternography. But recently, due to more short acquisition time, high resolution than other radiopharmaceuticals like In-111 DTPA, we were using Tc-99m DTPA in cisternography. Using of Tc-99m DTPA for intrathecal, was not officially recognised by the FDA. And there are matters of aseptic meningitis, muscular tetany, seizures by inappropriate radiopharmaceuticals handling. So, it is necessary to prevent adverse reactions while handling the radiopharmaceuticals using in cisternography. Therefore, this study aims to evaluation of usefulness and procedures for safety of radiopharmaceuticals in cisternography. Materials and Methods: Subjects were 12radioactive tracer vials using in cisternography in 2008 Dec. 16 - 2009 Dec. 30. (1) Radioactive tracer Vial test - We were measured NaPertechnetate radiation dose and volume, normal saline volume for dilution, source volume and dose activity for patient injection. And then, calculated mass of pure DTPA. (2) Bacterial endotoxin test - We performed pyrogen test using by negative/positive control vials which was added normal saline 0.2 mL and added normal saline 0.1 mL, Tc-99m DTPA 0.1 mL in test control vial. And then, reacted by digital hot plate in $37.5^{\circ}C$ for 1 hour and compared of gel-clot in each control vials. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety procedure exam sheet. Results: (1) Radioactive tracer Vial test - Mass of DTPA per dose for patient injection (mg) was 0.88 (mg) on average, and Mass of DTPA per volume for patient injection (mg) was 0.74 (mg) on average. (2) Bacterial endotoxin test - All control test vials showed negative reactions. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety exam sheet in all the exams. So, there were no adverse reactions. Conclusion: We could examine easier to safety tests using by Techscan - DTPA (Mallinckrodt): CaNa3. Each test results were passed the safety tests and there are no adverse reactions. The use of Tc-99m DTPA for cisternography, always has been become an issue. Since it has occur adverse reaction while examine the cisternography using by Tc-99m DTPA, it needs to set up the 'Standard Operating procedures'.

  • PDF

Study on the Difference in Intake Rate by Kidney in Accordance with whether the Bladder is Shielded and Injection method in 99mTc-DMSA Renal Scan for Infants (소아 99mTc-DMSA renal scan에서 방광차폐유무와 방사성동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구)

  • Park, Jeong Kyun;Cha, Jae Hoon;Kim, Kwang Hyun;An, Jong Ki;Hong, Da Young;Seong, Hyo Jin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.27-31
    • /
    • 2016
  • Purpose $^{99m}Tc-DMSA$ renal scan is a test for the comparison of the function by imaging the parenchyma of the kidneys by the cortex of a kidney and by computing the intake ratio of radiation by the left and right kidney. Since the distance between the kidneys and the bladder is not far given the bodily structure of an infant, the bladder is included in the examination domain. Research was carried out with the presumption that counts of bladder would impart an influence on the kidneys at the time of this renal scan. In consideration of the special feature that only a trace amount of a RI is injected in a pediatric examination, research on the method of injection was also carried out concurrently. Materials and Methods With 34 infants aged between 1 month to 12 months for whom a $^{99m}Tc-DMSA$ renal scan was implemented on the subjects, a Post IMAGE was acquired in accordance with the test time after having injected the same quantity of DMSA of 0.5mCi. Then, after having acquired an additional image by shielding the bladder by using a circular lead plate for comparison purposes, a comparison was made by illustrating the percentile of (Lt. Kidney counts + Rt. Kidney counts)/ Total counts, by drawing the same sized ROI (length of 55.2mm X width of 70.0mm). In addition, in the format of a 3-way stopcock, a Heparin cap and direct injection into the patient were performed in accordance with RI injection methods. The differences in the count changes in accordance with each of the methods were compared by injecting an additional 2cc of saline into the 3-way stopcock and Heparin cap. Results The image prior to shielding of the bladder displayed a kidney intake rate with a deviation of $70.9{\pm}3.18%$ while the image after the shielding of the bladder displayed a kidney intake rate with a deviation of $79.4{\pm}5.19%$, thereby showing approximately 6.5~8.5% of difference. In terms of the injection method, the method that used the 3-way form, a deviation of $68.9{\pm}2.80%$ prior to the shielding and a deviation of $78.1{\pm}5.14%$ after the shielding were displayed. In the method of using a Heparin cap, a deviation of $71.3{\pm}5.14%$ prior to the shielding and a deviation of $79.8{\pm}3.26%$ after the shielding were displayed. Lastly, in the method of direct injection into the patient, a deviation of $75.1{\pm}4.30%$ prior to the shielding and a deviation of $82.1{\pm}2.35%$ after the shielding were displayed, thereby illustrating differences in the kidney intake rates in the order of direct injection, a Heparin cap and the 3-way methods. Conclusion Since a substantially minute quantity of radiopharmaceuticals is injected for infants in comparison to adults, the cases of having shielded the bladder by removing radiation of the bladder displayed kidney intake rates that are improved from those of the cases of not having shielded the bladder. Although there are difficulties in securing blood vessels, it is deemed that the method of direct injection would be more helpful in acquisition of better images since it displays improved kidney intake rate in comparison to other methods.

  • PDF

CComparative evaluation of the methods of producing planar image results by using Q-Metrix method of SPECT/CT in Lung Perfusion Scan (Lung Perfusion scan에서 SPECT-CT의 Q-Metrix방법과 평면영상 결과 산출방법에 대한 비교평가)

  • Ha, Tae Hwan;Lim, Jung Jin;Do, Yong Ho;Cho, Sung Wook;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • Purpose The lung segment ratio which is obtained through quantitative analyses of lung perfusion scan images is calculated to evaluate the lung function pre and post surgery. In this Study, the planar image production methods by using Q-Metrix (GE Healthcare, USA) program capable of not only quantitative analysis but also computation of the segment ratio after having performed SPECT/CT are comparatively evaluated. Materials and Methods Lung perfusion scan and SPECT/CT were performed on 50 lung cancer patients prior to surgery who visited our hospital from May 1, 2015 to September 13, 2016 by using Discovery 670(GE Healthcare, USA) equipment. AP(Anterior Posterior)method that uses planar image divided the frontal and rear images into three rectangular portions by means of ROI tool while PO(Posterior Oblique)method computed the segment ratio by dividing the right lobe into three parts and the left lobe into two parts on the oblique image. Segment ratio was computed by setting the ROI and VOI in the CT image by using Q-Metrix program and statistically analysis was performed with SPSS Ver. 23. Results Regarding the correlation concordance rate of Q-Metrix and AP methods, RUL(Right upper lobe), RML(Right middle lobe) and RLL(Right lower lobe) were 0.224, 0.035 and 0.447. LUL(Left upper lobe) and LLL(Left lower lobe) were found to be 0.643 and 0.456, respectively. In the PO method, the right lobe were 0.663, 0.623 and 0.702, respectively, while the left lobe were 0.754 and 0.823. When comparison was made by using the Paired sample T-test, Right lobe were $11.6{\pm}4.5$, $26.9{\pm}6.2$ and $17.8{\pm}4.2$, respectively in the AP method. Left lobe were $28.4{\pm}4.8$ and $15.4{\pm}5.6$. The right lobe of PO had values of $17.4{\pm}5.0$, $10.5{\pm}3.6$ and $27.3{\pm}6.0$, while the left lobe had values of $21.6{\pm}4.8$ and $23.1{\pm}6.6$, thereby having statistically significant difference in comparison to the Q-Metrix method for each of the lobes (P<0.05). However, there was no statistically significant difference in Right middle lobe (P>0.05). Conclusion The AP method showed low concordance rate in correlation with the Q-Metrix method. However, PO method displayed high concordance rate overall. although AP method had significant differences in all lobes, there was no significant difference in Right middle lobe of PO method. Therefore, at the time of production of lung perfusion scan results, utilization of Q-Metrix method of SPECT/CT would be useful in computation of accurate resultant values. Moreover, it is deemed possible to expect obtain more practical sectional computation result values by using PO method at the time of planar image acquisition.