• Title/Summary/Keyword: acoustic analysis

Search Result 2,493, Processing Time 0.031 seconds

Analysis of Acoustic Emission Signal During Contact Start/stop Test on Computer Hard Disk (컴퓨터 하드디스크의 CSS 테스트에 의한 AE 신호 해석)

  • Hwang, Pyung;Kim, Woo-Seok;Kim, Do-Hyung
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.170-174
    • /
    • 1999
  • In order to analysis contact mechanism of head/ disk interface on hard disk drive, many techniques of analysis have been developed. Acoustic Emission sensor can be used for detect elastic energy of contact at head/disk interface. This work presents a good understanding of slider characteristics in frequency domain. The results show that torsional and bending mode of slider are dominant in head/disk contact.

  • PDF

FREQUENCY SPECTRUM ANALYSIS OF ACOUSTIC EMISSION OF HARD DISK DRIVE HEAD/DISK INTERACTION

  • Chung, K.H.;Oh, J.K.;Moon, J.T.;Kim, D.E.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.273-274
    • /
    • 2002
  • In order to evaluate the flying characteristics of slider, the acoustic emission (AE) as well as friction signals are typically utilized. In this work the frequency spectrum analysis is performed using the AE signal obtained during the head/disk interaction such as load/unload mechanism using ramp, impact situation in the presence of a bump on disk surface and other contact phenomena including particle interaction. It was shown that the influence of impact can be characterized effectively in the AE frequency spectrum. As a result of this work, frequency spectrum analysis will be utilized with better understanding for studying the head/disk interface (HDI) characteristics and monitoring the particle interaction in HDI effectively.

  • PDF

A Study on Design of Underwater Acoustic Transducers Using the Electro-mechanical Coupling Analysis Code ATILA (전기-기계 연성해석 코드 ATILA를 이용한 수중 음향 트랜스듀서 설계)

  • Lee, Jeong-min;Cho, Yo-han;Kim, Jung-suk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.10 s.103
    • /
    • pp.1211-1216
    • /
    • 2005
  • Underwater acoustic transducers are widely used for SONAR application, whose important design parameters are shapes. materials, dimensions and supporting structures. Practical design method of transducers consists of manufacturing, experiments and modifications so that it requires much time and expenses. In this study, an analytical method was developed for the Tonpilz type transducers using the commercial finite element analysis code ATILA which can solve the electro-mechanical coupling problems. A finite element model was established including the transducer elements such as ceramic stack, head mass, tail mass, tensile bolt, and molding layers. The proposed model was verified and modified by comparing the in-air and in-water test results of prototypes. The developed analysis method will be effectively used for the sensitivity analysis of design parameters in transducer design process.

Development of Software for Dynamic Analysis of Piezoelectric Underwater Transducers (압전 수중음향 센서의 동적해석 프로그램 개발)

  • 최준화;김재환;조치영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.1053-1058
    • /
    • 2003
  • Piezoelectric under water acoustic transducer is a kind of device for under water detection working as not only an actuator but also a sensor. The technique that can predict acoustical characteristics of transducer is important for robust design of transducer in harsh underwater environment. This paper represents the development of software for analyzing dynamic characteristics of piezoelectric acoustic transducers based on finite element method. Modal and transient analysis modulo for acoustic transducers are developed TWO dimensional model for Tonpilz transducer is used for the test of the developed nodal and transient analysis modules. and comparison is made with a commercial code, ANSYS.

  • PDF

The first attempt of utilization of a wideband autonomous acoustic system and its general knowledge on analyzing the wideband acoustic data (광대역 자율 음향 시스템의 국내 최초 활용 시도와 광대역 음향 데이터 분석 방안)

  • KANG, Myounghee;CHO, Youn-Hyoung;LA, Hyoung sul;SON, Wuju;YUN, Hyeju;ADRIANUS, Aldwin;AN, Young-Su
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.58 no.2
    • /
    • pp.130-140
    • /
    • 2022
  • Recently, wideband acoustic technology has been introduced and started to be used in fisheries acoustic surveys in various waters worldwide. Wideband acoustic data provides high vertical resolution, high signal-to-noise ratio and continuous frequency characteristics over a wide frequency range for species identification. In this study, the main characteristics of wideband acoustic systems were elaborated, and a general methodology for wideband acoustic data analysis was presented using data collected in frequency modulation mode for the first time in Republic of Korea. In particular, this study described the data recording method using the mission planner of the wideband autonomous acoustic system, wideband acoustic data signal processing, calibration and the wideband frequency response graph. Since wideband acoustic systems are currently installed on many training and research vessels, it is expected that the results of this study can be used as basic knowledge for fisheries acoustic research using the state-of-the-art system.

Comparison of various methods to obtain structural vibration for vibro-acoustic noise (구조 방사 소음의 해석을 위한 구조물의 진동 획득 방법의 비교)

  • Wang Se-Myung;Shin Min-Cheol;Koo Kun-Mo;Kim Dae-Sung;Bae Won-Ki;Kyong Yong-Soo;Kim Jung-Seon;Kook Jung-Hwan;Thuy Tran ho Vihn
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.607-611
    • /
    • 2006
  • There are several methods to obtain structural vibration for analysis of vibro-acoustic noise. First of all, vibration data can be obtained through the structural analysis using finite element method. Although this method has no need to experiment, the analysis result is unreliable when the structure and the vibration source is complex to model exactly. The second method is to measure vibration using a number of sensors. The analyzed vibro-acoustic noise with directly measured data is setting morereliable when the number of data acquisition points is getting larger. However, it requires large amount of time and effort to measure all vibration data on every node especially when the size of vibrating structure is large. The Modal Expansion Method(MEM), which uses mode information and measurement data, has been introduced to compensate their limits. With a relatively small number of measurement data, the reliable structural vibration for vibro-acoustic noise can be obtained using this semi-analysis method. Although MEM gives reliable result, it is restricted by the number of modes and measurement points. In this paper, structural analysis, direct vibration measurement method and MEM are compared using the simple aluminum box model. Furthermore, the washing machine case is also provided as a comparative example. The Laser Doppler Vibrometer(LDV) was used instead of contact type accelerometer to get vibration data.

  • PDF

Acoustic Characteristics of the Vocal Major Students with Vocal Nodule (성대결절이 있는 성악도에서의 음성분석학적 특징)

  • 진성민;김대영;김남훈;권기환;이경철;이용배
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.10 no.2
    • /
    • pp.135-139
    • /
    • 1999
  • Objectives : The purpose of this study was to systematically analyze and compare the acoustic characteristics of vocal major students with vocal nodule when singing. Materials and Methods : Ten sopranos with vocal nodule, who have never been treated due to voice problems, were the subject group. Twenty healthy sopranos major students were the control group for this study. The vocal nodule was confirmed by stroboscopy and the acoustic and electroglottographic analysis was conducted on be groups. Additionally, an inquiry on usual voice problems during speaking and singing were performed on each of the groups. Results : The vowel /a/ was spoken and sung by sopranos of each group. There were no significant differences in Fo, jitter, shimmer, NHR at speaking and singing in either group. We did not register any significant differences of closed quotient and speed quotient in electroglottography for both groups at singing, but speed quotient was increased in subject group at speaking(p<0.05). And the sopranos with nodule demonstrated voice fatigue(70%), strained and tired voice after long period of performance and conversation(60%) on inquiry. Conclusions : Although they had a vocal nodule, this group, who had a long period of voice training, did not present any differences in acoustic and electroglottographic problems during short performance, but, the vocalists noticed delicate voice problems after a long performance. We conclude that the voice training teacher and laryngologist must initiate voice management and speech therapy for vocal nodule, even if there is no specific abnormality in acoustic analysis.

  • PDF

Finite Element Analysis of Small Acoustic Filters for Hearing Protection Device (청각보호구용 소형 음향필터의 유한요소해석)

  • Kim, Dong Hoon;Lee, Yun Jung;Kim, Pil Un;Lee, Sang Heun;Cho, Jin Ho;Kim, Myoung Nam
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.2
    • /
    • pp.200-208
    • /
    • 2007
  • The noise induced hearing loss, which is one type of the hearing losses, is well known occupational diseases. The prevention of the noise induced hearing loss is very important, because it is unrecoverable. There are some kinds of devices for hearing protection, and those are effective in preventing the noise induced hearing loss. However, people often resist the use of hearing protection devices because they have some difficulties during conversation in wearing the devices. To solve the problem, a small acoustic filter can be used for a hearing protection device. In this paper, we designed several kinds of small acoustic filters and analyzed the characteristics of designed small acoustic filters using Finite Element Analysis (FEA). From FEA results, we proved the characteristics of designed small acoustic filters which vary according to length and diameter. And we found out that the general tendencies of modeled filters using FEA are same as acoustic experiment results of designed filters.

  • PDF

Influence of loading rate on flexural performance and acoustic emission characteristics of Ultra High Performance Concrete

  • Prabhat Ranjan Prem;Vignesh Kumar Ramamurthy;Vaibhav Vinod Ingle;Darssni Ravichandran;Greeshma Giridhar
    • Structural Engineering and Mechanics
    • /
    • v.89 no.6
    • /
    • pp.617-626
    • /
    • 2024
  • The study investigated the behavior of plain and fibered Ultra-High Performance Concrete (UHPC) beams under varying loading conditions using integrated analysis of the flexure and acoustic emission tests. The loading rate of testing is -0.25 -2 mm/min. It is observed that on increasing loading rate, flexural strength increases, and toughness decreases. The acoustic emission testing revealed that higher loading rates accelerate crack propagation. Fiber effect and matrix cracking are identified as significant contributors to the release of acoustic emission energy, with fiber rupture/failure and matrix cracking showing rate-dependent behavior. Crack classification analysis indicated that the rise angle (RA) value decreased under quasi-static loading. The average frequency (AF) value increased with the loading rate, but this trend reversed under rate-dependent conditions. K-means analysis identified distinct clusters of crack types with unique frequency and duration characteristics at different loading rates. Furthermore, the historic index and signal strength decreased with increasing loading rate after peak capacity, while the severity index increased in the post-peak zone, indicating more severe damage. The sudden rise in the historic index and cumulative signal strength indicates the possibility of several occurrences, such as the emergence of a significant crack, shifts in cracking modes, abrupt failure, or notable fiber debonding/pull-out. Moreover, there is a distinct rise in the number of AE knees corresponding to the increase in loading rate. The crack mapping from acoustic emission testing aligned with observed failure patterns, validating its use in structural health monitoring.