• Title/Summary/Keyword: accurate information

Search Result 6,488, Processing Time 0.043 seconds

Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City (1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로)

  • Dong, Kyung-Rae;Lee, Seun-Joo;Kweon, Dae-Cheol;Goo, Eun-Hoe;Jung, Jae-Eun;Lee, Kyu-Su
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within $1.5^{\circ}$. Of all fifty hospitals 30.0% were beyond $3^{\circ}$. The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible.

A Spectrophotometric Study on Color Differences between Various Light-Cured Composite Resins and Shade Guides (광중합형 복합레진과 shade guide의 색차에 관한 연구)

  • Lim, Kyung-Min;Lee, Min-Ho;Song, Kwang-Yeob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.13-22
    • /
    • 2009
  • The composite resin, due to its esthetic quality, is considered the material of choice for restoration of anterior teeth. To get a satisfactory result in the composite resin restorations, it is necessary to choose right shade. At present, most of the commercial composite resins are based on the Vita Lumin shade guides or shade guides that are provided by their company, but color differences among them might be expected even using the same shade in various materials. This study is to measure color differences between various light-cured composite resins and shade guides and to provide the clinicians with information which may aid in improved color match of esthetic restoration. Four kinds of light-cured composite resins (Gradia Direct (GD), Z250 (Z250), Clearfil AP-X (AP-X), Esthet X (E X)) and shade guides with A2 and A3 shade were used. Three specimens of each material and one specimen of each shade guide were made. Each composite resin was filled into the Teflon mold (1.35 mm depth, 8 mm diameter), followed by compression, polymerization and polishing with wet sandpaper. Shade guides were grinded with polishing stones and rubber points to a thickness of approximately 1.35 mm. Color characteristics were performed with a spectrophotometer(color i5, GretagMacbeth, USA). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E^*ab$) between composite resins and shade guides. CIE standard D65 was used as the light source. The results were as follows : 1. Among the $L^*$, $a^*$, $b^*$ values of most of 4 kinds of composite resin specimens which are produced by same shade, there were significant differences(p<0.05). 2. Among all 4 kinds of composite resin specimens which are produced by same shade, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 3. Between most of composite resin specimens investigated and their corresponding shade guides, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 4. In the clinical environment, it is recommended that custom shade guides be made from resin material itself for better color matching. Shade guides supplied by manufacturers or Vita Lumin shade guide may not provide clinicians a accurate standard in matching color of composite resins, and there are perceptible color differences in most of products. Therefore, it is recommended that custom shade guides be made from resin material itself and used for better color matching.

Repeatability and Reproducibility in Effective Porosity Measurements of Rock Samples (암석시험편 유효공극률 측정의 반복성과 재현성)

  • Lee, Tae Jong;Lee, Sang Kyu
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.209-218
    • /
    • 2012
  • Repeatability and reproducibility in solid weight and effective porosity measurements have been discussed using 8 core samples with different diameters, lengths, rock types, and effective porosities. Further, the effect of temperature on the effective porosity measurement has been discussed as well. Effective porosity of each sample has been measured 7 times with vacuum saturation method with vacuum pressure of 1 torr and vacuum time of 80 minutes. Firstly, effective porosity of each sample is measured one by one, so that it can provide a reference value. Then for reproducibility check, effective porosity measurements with vacuum saturation of 2, 4, and 8 samples simultaneously have been performed. And finally, repeated measurements for 3 times for each sample are made for repeatability check. Average deviation from the reference set in solid weight showed 0.00 $g/cm^3$, which means perfect repeatability and reproducibility. For effective porosity, average deviations are less than 0.07% and 0.05% in repeatability and reproducibility test sets, respectively, which are in good agreement too. Most of porosities measured in reproducibility test lies within the deviation range in repeatability test sets. Thus, simultaneous vacuum saturation of several samples has little impact on the effective porosity measurement when high vacuum pressure of 1 torr is used. Air temperature can cause errors on submerged weight read and even effective porosity, because it is closely related to the temperature, density, and buoyancy of water. Consequently, for accurate measurement of effective porosity in a laboratory, efforts for maintaining air or water temperature constant during the experiment, or a temperature correction from other information are needed.

Analysis of Purchasing Behaviors of Processed Foods in High School Students in Yongin Region (용인지역 고등학생의 가공식품 구매행동 분석)

  • Koo, Hee Jin;Kim, Seong Yeong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.12
    • /
    • pp.1929-1936
    • /
    • 2014
  • This study investigated purchasing behaviors of processed foods in high school students (male 94 and female 85) in the Yongin region. Frequency of eating processed foods was generally once (36.9%) or twice (32.4%) a day. Frequency according to processed food items was in the following order: confectionary (31.3%)> beverages (17.3%)> breads (12.3%)> instant noodles (11.7%) and milk or dairy products (11.7%)> frozen desserts (10.6%). The places for purchasing were a big mart (30.7%), convenience store (28.5%), and school cafeteria (26.8%). The reasons for purchasing were 'tasty' at 43.6% and 'hungry' at 35.2%. Main factors affecting purchasing were 'taste' at 70.9%, followed by price (16.2%)> quantity (5.6%)> nutrition (4.5%). The most important parts of food and nutrition labels were 'shelf-life' (67.0%) and 'calories' (57.5%). Degrees of confirmation of food and nutrition labeling were 'always' (12.3%), 'rarely' (28.5%), and 'sometimes' (59.2%). The reasons for not reading labels were 'unconcerned' (27.9%), 'too tiny lettering' (28.5%), 'hard to understand' (16.2%), and 'habitually' (15.1%). These results reflect low attention of high school students towards healthy food choices using food and nutrition labeling during purchasing. In conclusion, a specific education program for providing accurate product information as well as leading healthy purchasing behaviors should be required.

Outcomes of Patients with COPD Requring Mechanical Ventilation (만성폐쇄성폐질환 환자의 기계호흡시 생존 예측 인자 분석)

  • Baik, Jae-Joong;Kim, Sang-Chul;Lee, Tae-Hoon;Chung, Yeon-Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.2
    • /
    • pp.179-188
    • /
    • 2000
  • Background : The decision to institute mechanical ventilation for patients with COPD is very difficult. The accurate information regarding weaning success and long-term survival will improve communication with patients and family and enhance informed consent. The aims of this study are to describe outcomes and identify variables associated with survival for patients experiencing mechanical ventilation with an acute respiratory failure of COPD. Methods : The 53 cases of mechanical ventilation in the intensive care unit in the National Medical Center from 1989 to 1998 were included. Data were collected retrospectively from medical records. Weaning success rate and 3 month and 1 year survival rates were estimated. Factors associated with weaning success and survival were determined. Results : Weaning sucess was 55%. For success group with 29 cases, 3 months survival rate was 61% and 1 year survival rate 37%. APACHE II scores in weaning success group were significantly lower than those in the failure group. Factors such as age, sex, comorbid-illnes. previous steroid use, causes of respiratory failure, RVH or arrhythmia on EKG, serum albumin level, arterial blood pH, $PaO_2$, $PaCO_2$, $FEV_1$ duration of mechanical ventilation and steroid use during mechanical ventilation were not associated with weaning success. Only age and serum albumin level were associated with 3 month and 1 year survival. No COPD patients of age more than 75 years and serum albumin level less than 3g/dl had survived at 1 year after weaning success. Conclusion : While weaning success from mechanical ventilation can be predicted by APACHE II score in COPD patients, long-term outcomes of survivors may be influenced by nutritional status and age.

  • PDF

A Relationship Between Dentistry Consumers' Knowledge and Expectation of Dental Implants (치과의료소비자의 임플란트에 대한 지식과 기대도의 관련성)

  • Yoo, Eun-Mi;Shim, Hyun-ju
    • Journal of dental hygiene science
    • /
    • v.10 no.4
    • /
    • pp.219-225
    • /
    • 2010
  • The purpose of this study was to examine the patients' knowledge and expectation of dental implants and to provide effective consulting and accurate information on implants to them. To that end, between March 23, 2008 and June 5, 2008, patients who were visiting dental clinics (hospitals) in Seoul, Gyeonggi-do, and Incheon areas were surveyed. 84.7% of subjects said that they recognized implants, and the largest number of them (26.7%) of subjects came to know via friends. According to an analysis of subjects' knowledge of the dental implant operation, the maximum value was 4.06, and the minimum value was 3.05. The opinion value on the need to have regular examination after the implant operation was highest at 4.06. Regarding expectation over the implant operation, the maximum value was 4.42, and the minimum value was 1.78. The opinion value on considering the implant operation capability the most important was the highest at 4.42. The relationship between the knowledge of and expectation over implants was significant. By gender, females had a significantly higher level of knowledge than males. Regarding preference, females scored 3.27 points, and males scored 3.23 points. By occupation, professionals earned the highest score of 3.55 in knowledge, and professionals earned the highest score of 3.31 in expectation. According to an analysis of the relation between variables of knowledge of and variables of expectation over implants, the correlation coefficient (r) between the two factors was 0.362, indicating a positive relevancy(+)(p<.01).

Analysis of the Efficiency of Gyeonggi-do Senior Welfare Centers by DEA Model (DEA를 이용한 경기도 노인복지관 효율성 분석)

  • Kim, Keum Hwan;Pak, Ae Kyung;Ryu, Seo Hyun;Lee, Nam Sik
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.8 no.3
    • /
    • pp.165-177
    • /
    • 2013
  • The purpose of this study was to examine the efficiency of senior welfare centers and the cause of differences among senior welfare centers in that regard, and to investigate influential factors for the differences in efficiency and the size of the influence of the factors. What methods would be effective at assessing the efficiency of senior welfare centers by taking into account their circumstances was reviewed, andpost-hoc analyses were made by using data envelopment analysis(DEA) and DAE/AP Modified prosthetic which were useful tools to evaluate relative efficiency. After 20 senior welfare centers located in Gyeonggi-do were selected, their yearly operating data of 2009 were utilized. The purpose of this study was to examine the efficiency of senior welfare centers. The evaluation data released by the Gyeonggi Welfare Foundation were analyzed by DEA, which is one of nonparametric statistics, and it was possible to obtain significant results on the regional operating efficiency of social welfare centers in 14 metropolitan cities and provinces, the causes and degree of their inefficiency and what areas one could refer to. As the data for the counties were utilized in this study, it's not quite possible to produce accurate results on the relative efficiency of senior welfare centers, but this study could be said to be of significance in that it suggested how to evaluate the overall operating efficiency of senior welfare centers in the counties involving the degree of their operating inefficiency, what improvements should be made and what reference groups there might be and provided information on the usefulness of the DEA model.

  • PDF

The Feasibility Study of MRI-based Radiotherapy Treatment Planning Using Look Up Table (Look Up Table을 이용한 자기공명영상 기반 방사선 치료계획의 타당성 분석 연구)

  • Kim, Shin-Wook;Shin, Hun-Joo;Lee, Young-Kyu;Seo, Jae-Hyuk;Lee, Gi-Woong;Park, Hyeong-Wook;Lee, Jae-Choon;Kim, Ae-Ran;Kim, Ji-Na;Kim, Myong-Ho;Kay, Chul-Seung;Jang, Hong-Seok;Kang, Young-Nam
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.237-242
    • /
    • 2013
  • In the intracranial regions, an accurate delineation of the target volume has been difficult with only the CT data due to poor soft tissue contrast of CT images. Therefore, the magnetic resonance images (MRI) for the delineation of the target volumes were widely used. To calculate dose distributions with MRI-based RTP, the electron density (ED) mapping concept from the diagnostic CT images and the pseudo CT concept from the MRI were introduced. In this study, the look up table (LUT) from the fifteen patients' diagnostic brain MRI images was created to verify the feasibility of MRI-based RTP. The dose distributions from the MRI-based calculations were compared to the original CT-based calculation. One MRI set has ED information from LUT (lMRI). Another set was generated with voxel values assigned with a homogeneous density of water (wMRI). A simple plan with a single anterior 6MV one portal was applied to the CT, lMRI, and wMRI. Depending on the patient's target geometry for the 3D conformal plan, 6MV photon beams and from two to five gantry portals were used. The differences of the dose distribution and DVH between the lMRI based and CT-based plan were smaller than the wMRI-based plan. The dose difference of wMRI vs. lMRI was measured as 91 cGy vs. 57 cGy at maximum dose, 74 cGt vs. 42 cGy at mean dose, and 94 cGy vs. 53 at minimum dose. The differences of maximum dose, minimum dose, and mean dose of the wMRI-based plan were lower than the lMRI-based plan, because the air cavity was not calculated in the wMRI-based plan. These results prove the feasibility of the lMRI-based planning for brain tumor radiation therapy.

BONE DENSITY AND HISTOMORPHOMETRY ASSESSMENT OF DENTAL IMPLANT USING COMPUTERIZED TOMOGRAPHY (컴퓨터 영상을 이용한 임플란트 식립부위의 골밀도와 조직학적 연구)

  • Son, Jang-Ho;Choi, Byung-Hwan;Park, Soo-Won;Cho, Yeong-Cheol;Sung, Iel-Yong;Lee, Ji-Ho;Byun, Ki-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.136-142
    • /
    • 2009
  • Bone density in the recipient implant site seems to be an important factor for long term success of endosseous implants. Preoperative evaluation of bone density is very helpful to assist the clinician with the treatment planning of implant therapy. Accurate information on bone density will help the surgeon identify suitable implant sites, thereby improving the success rate of the procedure. Purpose; The aim of this study was to evaluate a correlation between bone density measured preoperatively with computerized tomography and histologically measured bone density by bone biopsy. Patients and methods; Twenty seven patients were selected. All the patients were in good health, with no systemic disorder and additional bone graft. Preoperatively the patients underwent CT scanning to evaluate Houmsfield Unit(HU). Each patients wore a surgical template for implant placement. During surgery 2mm in diameter and 6mm in length specimens were taken. Histomorphometric analysis was performed using digitalized image analysis software Axiovision 4.3. Also, the Resonance frequency analysis(RFA) and insertion torque values were recorded. Results; The highest histomorphometric values was found in the posterior mandible $32.3{\pm}3.8$, followed by $29.9{\pm}2.6$ for the posterior maxilla, $29.4{\pm}2.6$ for the anterior maxilla, $28.6{\pm}2.3$ for the anterior mandible(p=0.214). The hounsfield unit was $989.2{\pm}258.1$ in the posterior mandible, $845.0{\pm}241.5$ in the anterior maxilla, $744.5{\pm}92.6$ in the anterior mandible, $697.3{\pm}136.9$ in the posterior maxilla(p=0.045). This results may suggest that there are strong correlation between the histomorphometric values and hounsfield unit(r=0.760, p<0.05). The RF measurements were $81.9{\pm}2.4$ ISQ in the posterior mandible, $79.0{\pm}1.4$ ISQ in the anterior mandible, $78.3{\pm}4.6$ ISQ in the posterior maxilla, $76.5{\pm}5.0$ ISQ in the anterior maxilla(p=0.048). The insertion torque values was $43.2{\pm}4.2\;Ncm$ in the posterior mandible, $42.0{\pm}0.0\;Ncm$ in the anterior mandible, $41.3{\pm}4.1\;Ncm$ in the posterior maxilla, $40.8{\pm}3.8\;Ncm$ in the anterior maxilla(p=0.612). This results may suggest that there are statistical significance between the hounsfield unit and the insertion torque values(r=0.494, p<0.05), the histomorphometric values and the insertion torque values(r=0.689, p<0.05). But there was no correlation between histomorphometric values and ISQ. There was no statistical significance in age and gender effect on parameters. Conclusions; There was significant correlations between bone density and implant stability parameters. The bone density measurements using preoperative CT may help clinicians to predict primary stability before implant insertion, which is associated with implant survival rates.

A Radiologic Study of the Relationship of the Maxillary Sinus Floor and Apex of the Maxillary Molar (상악동 아래벽과 상악 대구치 치근사이 위치관계에 관한 방사선학적 연구)

  • Yoon Hae-Rym;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.111-126
    • /
    • 1998
  • In this study, radiographic evaluation was made using panoramic radiography and cross-sectional tomography of SCANORA/sup (R)/ in male and female adults in their 20's on the relationship between the maxillary sinus floor and the apex of the maxillary molar, to test the accuracy and effectiveness of the cross-sectional tomography, and to use this information in the assessment of preop. and postop. root canal treatment, apical surgery, extraction and implantology. Forty-one adults with an average age of 24.4 years were studied using panoramic radiography and cross-sectional tomography. In panoramic view and cross-sectional view, the position of the apices of maxillary molars were classified as separated, contacted, or protruded type; the general shape of the maxillary sinus floor was evaluated horizontally and vertically from cross-sectional tomography. The accuracy of each radiography was tested using maxilla from 5 fresh cadavers from the Anatomy Lab at Yonsei University Dental College, and panoramic view and cross-sectional tomography were taken in the same condition as with the patients. The results were as follows: 1. Panoramic view and cross-sectional view were taken in the maxilla specimen, and the actual distance between the maxillary sinus floor and the tooth apices were measured in the specimen; the median values of the distance from the tooth apices to the maxillary sinus floor in the panoramic view, cross-sectional view and in the actual maxilla specimen were 2.83 mm, 4.51mm, and 4.l5mm, respectively. In the cross-sectional view, the measured distance was close to the actual distance but in the panoramic view, the measured distance was far from the actual distance. 2. When the results of the panoramic view and cross-sectional view were compared, 40.5% of the results agreed with each other in the two radiographic methods and buccal roots of the 2nd molar were the closest to the maxillary sinus floor in the cross-sectional tomography. 3. In cross-sectional view, when the vertical relationship of the maxillary sinus floor and maxillary roots was assessed, in 1st molars, type II (the sinus floor that extends down to the buccolingual furcation area) was predominant, while in 2nd molars, type I (the sinus floor located above the level connecting the buccal and lingual apices) was predominant. In the horizontal relationship, in 1st molars, type II (the lowest floor of the maxillary sinus located in between the buccal and lingual roots) was predominant; in 2nd molars, type I (the lowest floor of the maxillary sinus located on the buccal side of the buccal roots) and type II appeared in similar frequency. In conclusion, the SCANORA/sup (R)/ cross-sectional tomography was more effective than the frequently used panoramic view, in that the relationship of the maxillary molars and maxillary sinus floor can be evaluated more accurately and the buccolingual cross-sectional view can also be observed. And maxillary sinus floor that was close to maxillary 2nd molar had tendency to be located on buccal side than that close to 1st molar. Therefore, cross-sectional tomography is an effective and accurate method to evaluate the position of the teeth in relation to the sinus floor preoperative and can be easily used to diagnose localized periapical lesions. Also, the image quality obtained was quite satisfactory.

  • PDF