• 제목/요약/키워드: accuracy-study

검색결과 16,168건 처리시간 0.043초

수치지도의 정확도 검정에 관한 연구 (A Study on the Accuracy Assessment of Digital Map)

  • 김병국;최정민;김은모
    • 한국측량학회지
    • /
    • 제16권2호
    • /
    • pp.319-326
    • /
    • 1998
  • 본 연구에서는 막대한 비용과 노력을 들여서 제작된 수치지도의 위치정확도를 실험적으로 판단하고자 하였다. 수치지도의 위치정확도 평가를 위해서 GPS와 Total Station을 이용한 현지측량을 실시하였으며, 현지측량의 성과와 수치지도를 비교함으로써 1:5,000 수치지도의 위치정확도를 판단해 보았다. 그리고, 1:5,000 수치지도의 이론적인 기대정확도와 현지 측량성과를 비교하여 향후 수치지도의 위치정확도 평가방법 및 개선을 위한 연구방향을 고찰해 보았다.

  • PDF

데오드라이트 시스템의 측정 정확도에 대한 연구(V) - 타켓 바의 거리에 따른 측정 정확도 (A Study on Measurement Accuracy of A Theodolite System(V) - A Measurement System Accuracy depending on the distance from theodolite system to target Bars)

  • 윤용식;이동주
    • 한국공작기계학회논문집
    • /
    • 제14권4호
    • /
    • pp.13-21
    • /
    • 2005
  • The affected factors for an accuracy of theodolite system are not only the measurement environment of temperature, illumination, etc. but also the measurement processes of the distance between two theodolites, the distance from theodolite system to scale bar and the distance from theodolite system to targets. We have known that the best collimation distance between two theodolites and the best distance from theodolite system to scale bar is $3{\sim}4m$. This study was performed for searching the best distance from theodolite system to targets on above measurement configuration. And, we could know that the best distance from theodolite system to targets is $2{\sim}6m$ and the system accuracy could be within ${\pm}0.025mm$.

스크린리더를 사용하는 시각장애인의 한국어 합성음 청취속도 연구 (A Study of Korean TTS Listening Speed for the Blind Using a Screen Reader)

  • 이희연;홍기형
    • 말소리와 음성과학
    • /
    • 제5권3호
    • /
    • pp.63-69
    • /
    • 2013
  • The purpose of this study was to evaluate the maximum and optimal listening speed of Korean TTS for the blind. Five blind participants took part in this study. The instruments used in this study were 17 sentence sets (2 sets for an excercise, 10 sets for a repeated test, and 5 sets for a random test), with short meaningful sentences (the same sentences for the repeated test, different sentences for the random test) with 15 differentiated speeds (Range=0.8-3.6, SD=0.2). Each participant's maximum and quickest listening speeds were calculated by objective recall accuracy (determined by the number of correctly recalled syllables/the total number of syllables in a sentence X 100) and subjective recall accuracy (recall accuracy judged by each participant's subjective evaluation). The results showed that the participants' recall accuracy had a tendency to increase as the TTS speed decreased. Participants' subjective recall accuracy was higher than objective recall accuracy in the repeated tests and vice versa in the random tests. The results also revealed that the participants' sentence familiarity had an influence on their Korean TTS listening speed.

환경정보체계의 효과적 이용에 관한 고찰 - 원자료의 정확성을 중심으로 - (A study on the Effective Use of Environmental Information System - focused on the accuracy of raw data -)

  • 이규석
    • 환경영향평가
    • /
    • 제7권2호
    • /
    • pp.27-35
    • /
    • 1998
  • In Korea, the initial installation of GIS requires lots of cost, time, and human efforts. If the accuracy of GIS data does not meet the certain standard for use, the system may not work as expected. So, it needs to be investigated for the accuracy of raw data. However, there is little study for the accuracy of raw data in Korea. Therefore, the purpose of this study is to review the data accuracy of raw data - geologic map, 1:5,000 and 1:25,000 scale topographic map, forest stand map, degree of green naturality(DGN) map, and detailed survey data of DGN map-, which are to be used in Environmental Information System(EIS) in Korea. After this study, some errors in data were surveyed and following conclusions were derived. (1) There is no map data, e. g, wildlife habitat map. (2) Some data are misinterpreted depending on the location in the geologic map. (3) Some data are not updated properly after change of topography in the topographic map or the elevation and location is different depending on the scale.. (4) Some data are not edited properly in the forest stand map, e. g. two attributes in one polygon. (5) DGN classification system does not reflect the characteristic of Korean vegetation community. So, it needs to be refined and restructured.

  • PDF

Comparisons of Accuracy of Knee Joint Motion During Closed verse Open Kinetic Chain Tasks in Subjects with Flexible Flatfeet

  • Kim, Ju Sang;Kwon, Younghyun;Lee, Mi Young
    • The Journal of Korean Physical Therapy
    • /
    • 제31권1호
    • /
    • pp.13-17
    • /
    • 2019
  • Purpose: This study examined the effects of flexible flatfeet on the accuracy of knee joint motions in closed and open kinetic chain tasks. Methods: Twenty-four healthy participants were recruited for this study. The subjects were divided into two groups using a navicular drop (ND) test: flexible flatfoot group (n=12, male: 6, aged $22.00{\pm}2.22years$) and age-matched control group (n=12, males: 6, aged $22.17{\pm}1.53years$). The accuracy of knee motion was measured quantitatively by tracing through the flexion and extension motion of the knee joints in the closed kinetic chain and the open kinetic chain. Results: There was a significant difference in the accuracy index between the groups in closed kinetic chain task, but there was no significant difference in the open kinetic chain task. In addition, there was a significant difference in the accuracy index between the closed kinetic chain and the open kinetic chain task in the flexible flatfoot group. In addition, a significant negative correlation was observed between the ND and accuracy index in the closed kinematic chain task, but there was no significant relationship between the ND and accuracy index in the open kinematic chain task. Conclusion: Flexible flatfeet can affect the accuracy of the adjacent joints, such as the knee joint in the closed kinematic chain.

수소충전소 계량 정확도 향상을 위한 거래량 산출 모델 연구 (A Study on the Transaction Volume Calculation model for Improving the Measurement Accuracy of Hydrogen Fuelling Station)

  • 최진영;이화영;임상식;이재훈
    • 한국수소및신에너지학회논문집
    • /
    • 제33권6호
    • /
    • pp.692-698
    • /
    • 2022
  • With the expansion of domestic hydrogen fuelling station infrastructure, it is necessary to secure reliability among hydrogen traders, and for this, technology to accurately measure hydrogen is important. In this study, 4 types of hydrogen trading volume calculation models (model 1-4) were presented to improve the accuracy of the hydrogen trading volume. In order to obtain the reference value of model 4, and experiment was conducted using a flow rate measurement equipment, and the error rate of the calculated value for each model was compared and analyzed. As a result, model 1 had the lowest metering accuracy, model 2 had the second highest metering accuracy and model 3 had the highest metering accuracy until a certain point. But after the point, model 2 had the highest metering accuracy and model 3 had the second metering accuracy.

열탈착/GC/FID를 이용한 B, T, X 분석의 정확도 및 정밀도 평가 (A Study on Evaluation of Accuracy and Precision on B, T, X Analysis Using Thermal Desorption/Gas Chromatograph/Flams Ionization Detector)

  • 박정근;유기호
    • 한국대기환경학회지
    • /
    • 제16권3호
    • /
    • pp.265-275
    • /
    • 2000
  • By using thermal desorption/gas chromatograph/flame ionization detector(TD/GC/FID), this study was carried out to evalute an accuracy and a precision on Benzene(B), Toluene(T), o-Xylene(X) analysis in an industrial hygiene laboratory. Limits of detection of TD/GC/FID on B, T, X were showed 13.75ng/sample or less. For the accuracy of the method by concentration levels, overall bias was showed 7.7% as an absolute value, and the pooled coefficient of variation showed 3.51%. For the precision on repeatability of peak area and retention time between within-run and between-run of analytical system, it is showed the results of within-run gave better than those of between-run. Also the accuracy by sorbents(Tenax TA and Chromosorb 106)was evaluated, and the precision on reproducibility between MDHS72 and this study was compared. It is showed it is possible for TD/GC/FID to evaluate accurately B, T, X concentration levels of less than 1ppm at indoor or outdoor of workplaces in Korea.

  • PDF

금형가공을 위한 고속.고정도 가공기술의 연구 (A study on Processing technology of high-speed and high-accuracy for Metal Mold Cutting)

  • 박희영
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.221-226
    • /
    • 1999
  • It can be acquired the high effective productivity through of high speed, precision of machine tools, and then, machine tools will be got a competitive power. Industrially advanced countries already developed that the high speed feed is 50m/min using the high speed ball screw. Also, a lot of problems have happened the feed and servo drive system. It is necessary to study about the character of positioning accuracy, heat generation and high speed/accuracy control for feed/servo drive system of high speed/accuracy. In this study, we make use of high performance vertical machine center with a ball screw of large-scale-lead. Also, we'll apply the high-speed/accuracy control technology in this part of feedforward control, multi-buffering block size, etc. Using the design of the mechanical element and high-speed precision control, the basic design concept can be established.

  • PDF

자연어 알고리즘을 활용한 한국표준건강분류(KCF) 코드 검색 (Korean Standard Classification of Functioning, Disability and Health (KCF) Code Linking on Natural Language with Extract Algorithm )

  • 최년식;송주민
    • 대한물리의학회지
    • /
    • 제18권1호
    • /
    • pp.77-86
    • /
    • 2023
  • PURPOSE: This study developed an experimental algorithm, which is similar or identical to semantic linking for KCF codes, even if it converted existing semantic code linking methods to morphological code extraction methods. The purpose of this study was to verify the applicability of the system. METHODS: An experimental algorithm was developed as a morphological extraction method using code-specific words in the KCF code descriptions. The algorithm was designed in five stages that extracted KCF code using natural language paragraphs. For verification, 80 clinical natural language experimental cases were defined. Data acquisition for the study was conducted with the deliberation and approval of the bioethics committee of the relevant institution. Each case was linked by experts and was extracted through the System. The linking accuracy index model was used to compare the KCF code linking by experts with those extracted from the system. RESULTS: The accuracy was checked using the linking accuracy index model for each case. The analysis was divided into five sections using the accuracy range. The section with less than 25% was compared; the first experimental accuracy was 61.24%. In the second, the accuracy was 42.50%. The accuracy was improved to 30.59% in the section by only a weight adjustment. The accuracy can be improved by adjusting several independent variables applied to the system. CONCLUSION: This paper suggested and verified a way to easily extract and utilize KCF codes even if they are not experts. KCF requires the system for utilization, and additional study will be needed.

정확도 및 정밀도 관점에서의 통계적 품질기법의 해석 (Interpretation of Statistical Quality Techniques in the Perspective of Accuracy and Precision)

  • 최성운
    • 대한안전경영과학회지
    • /
    • 제9권1호
    • /
    • pp.119-131
    • /
    • 2007
  • Engineer and quality statistician use different terms and techniques but they have same meaning and concept. The terms accuracy and precision are frequently used by engineer and scientist in the department of R&D and production technology. This paper makes a contribution to the interpretation of statistical quality techniques by the use of accuracy and precision. Engineer and scientist who have six sigma black belt and statistical background can use efficiently and effectively accuracy and precision in a manner consistent with statistical usage according to this study.