• Title/Summary/Keyword: accuracy test

Search Result 4,894, Processing Time 0.031 seconds

A Practical Method for Automotive Accelerated Life Test

  • Won Jung;Lee, Ik-seong
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2001.05a
    • /
    • pp.129-133
    • /
    • 2001
  • Accelerated life test is a viable method for identifying failure modes, incorporating design changes on an on-going basis during the early stages of automotive development program. The information from tests at high stress levels is extrapolated to obtain estimate of life at normal stress levels. This paper presents a practical method for accelerated life test to achieve a specified accuracy in estimating life at a design stress. Recommended and optimum plan are presented and the plans are illustrated with a simulated test data for the automotive power element example.

  • PDF

A Test of Multivariate Normality Oriented for Testing Elliptical Symmetry

  • Park, Cheol-Yong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.17 no.1
    • /
    • pp.221-231
    • /
    • 2006
  • A chi-squared test of multivariate normality is suggested which is oriented for detecting deviations from elliptical symmetry. We derive the limiting distribution of the test statistic via a central limit theorem on empirical processes. A simulation study is conducted to study the accuracy of the limiting distribution in finite samples. Finally, we compare the power of our method with those of other popular tests of multivariate normality under a non-normal distribution.

  • PDF

Proficiency Testing by Inter-Laboratory Comparisons for Braking Lining (제동 라이닝애 대한 시험소간 비교에 의한 숙련도시험)

  • Chung Jong-Duk;Kwon Sung-Tae;Hong Yung-Ki;Kim Won-kyung
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.586-591
    • /
    • 2003
  • This paper describes the result of proficiency testing by inter-laboratory comparisons for braking lining. Proficiency testing provides an objective means of assessing and demonstrating the validity and reliability of test results produced by laboratories. To more accuracy comparison test for braking lining test, they will be made the same test procedure and environment conditions.

  • PDF

Micro computer-controlled automatic test method for automotive brake system (Micro computer를 이용한 자동차용 brake 시험 자동화 system에 대한 고찰)

  • 정화영
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.9 no.5
    • /
    • pp.6-18
    • /
    • 1987
  • Owing to remarkable development in automotive industry, vehicle performance comes close to perfection and guarantee of stability is getting emphasized in accordance with high speed trend in vehicle. In recent years, the utilization of automatic test method for research and development of automotive brake system is being propelled actively, which pursue whole automatic control from simple measurement to data acquisition. The main subject of this paper is to make a brief explanation on Micro computer controlled Automatic Test Method for Automotive Brake System which makes it possible to test with high accuracy and speed.

  • PDF

Comparative Analysis of Preoperative Diagnotic Findings with Histologic Results in Thyroid Nodule (갑상선 결절의 술전진단과 술후 조직학적 결과의 비교분석)

  • Park Jin-Young;Cho Hyun-Jin;Lim Sung-Chul
    • Korean Journal of Head & Neck Oncology
    • /
    • v.16 no.1
    • /
    • pp.52-57
    • /
    • 2000
  • Purpose: The purpose of the study was to evaluate the sensitivity, specificity and accuracy between the FNAC and intraopevative frozen biopsy based upon the Final histologic diagnosis. Method: Authors studied 232 cases of thyroid nodule operated at Department of Surgery, College of Medicine, Chosun University, from January 1992 to December 1998. The medical records of these patients were studied retrospectively. The cytology of FNAC and the frozen section was compared to the final histologic diagnosis. 232 cases were analysed in regard to correlation of FNAC diagnosis and Intraoperative frozen section with final pathology, preoperative thyroid scan, thyroid function test, ultrasonography, final histopathology of the specimens, and surgical operation methods. 174 cases who underwent FNAC for diagnosis before operation, and Intraoperative frozen-section biopsy were classified according to whether the clinical diagnosis was benign, suspicious or malignant and evaluated the specificity sensitivity and accuracy. Result: Comparing with final histopathology, FNAC as a diagnostic test for thyroid nodules demonstrated an accuracy of 81.3%, a sensitivity of 87.5%, a specificity 86.5% with a false positivity of 2.9%, false negativity of 4.3%, respectively. and Intra-operative frozen section demonstrated an accuracy of 86.8%, a sensitivity of 87.5%, a specificity 92.1%. In the benign lesion, there was no difference in accuracy between FNAC(95.6%) and frozen section(95.1%) but, in the suspicious malignant lesion, frozen section(46.2%) was superior to FNAC(32.0%), and in the malignant disease, FNAC(97.1%) was superior to frozen section(92.3%). Conclusion: Intraoperative frozen section biopsy is useful in patients undergoing surgery for a thyroid nodule with a 'suspicious' malignant lesion and could reduce inadequate extensive excision without missing malignancy and second operation and help to determine the resection margin. It adds no information in patients with a diagnosis of malignancy following FNAC assessment and is of limited use in those in whom a benign lesion is diagnosed.

  • PDF

Comparison of Sampling and Analytical Methods for Determining Airborne Hexavalent Chromium -Limit of Detection, Accuracy and Precision of Analytical Procedures (공기중 6가 크롬 측정 방법 비교 -검출한계, 정확도 및 정밀도-)

  • 신용철;이병규;이지태
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.1
    • /
    • pp.39-49
    • /
    • 2002
  • In this study, limits of detection (LOD), accuracy and precision of four sampling/ analytical methods were evaluated and compared for the determination of airborne hexavalent chromium, Cr (VI). The methods include : (1) a combination of the National Institute for Occupational Safety and Health (NIOSH) Method 7600/U. S. Environmental Protection Agency (EPA) Method 218.6 (NIOSH/EPA Method) proposed by Shin and Paik, 2) two impinger methods using 2% NaOH/3% Na$_2$CO$_3$. (3) same as (2) but with 0.02 N NaHCO$_3$absorbing solution, and (4) the Occupational Safety and Health (OSHA) Method ID-215. An ion chromatograph/visible absorbance detector was used for the analysis of Cr (VI) in sample solution. Limit of detection (LOD) , analytical accuracy, and precision were also tested using Cr (VI) spike samples. Recoveries (as index of accuracy) and coefficient of variation (CV) (as a index of precision) were determined. Two-way ANOVA and Turkey's test were performed to test the significance in differences among recoveries and CVs of the methods. In all the methods, the peaks of Cr (VI) were separated sharply on chromatograms and exhibited a strong linearity with Cr (VI) concentrations in solution. The correlation coefficients of calibration curves typically ranged from 0.9997 to 0.9999, and the analytical LODs from 0.025 to 0.1$\mu\textrm{g}$/sample. All the method had good sensitivities and linearities between Cr (VI) levels and peak areas. The accuracies (% mean recoveries) of the methods ranged from 80.1 to 104.2%, while the precisions (pooled coefficient of variation) ranged from 3.16 to 4.43%. The impinger methods showed higher recoveries ( > 95%) than those of the PVC filter methods (the OSHA Method and the NIOSH/EPA Method). It was assumed that Cr (VI) on PVC filter was exposed to air and reduced to trivalent chromium, Cr (III), whereas it was stabilized in alkali solution contained in impinger. Thus, a special treatment of Cr (VI) samples collected on PVC filters may be required.

Evaluation of Airborne LiDAR Data using Field Surveyed Ground Control Points (현지 측량기준점을 이용한 LiDAR 데이터의 정확도 검증)

  • Wie, Gwang-Jae;Yang, In-Tae;Suh, Young-Woon;Sim, Jung-Min
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.14 no.4 s.38
    • /
    • pp.11-18
    • /
    • 2006
  • In this paper, airborne LiDAR data were evaluated in horizontal and vertical accuracy. By using zigzag scanning type of LiDAR, GCPs are not tested directly. So points around GCPs were used in this evaluation. Building corner points were made from LiDAR's building planar and compared with ground surveyed GCPs, in horizontal accuracy test. Its accuracy shows 19cm average and 21cm RMSE and 15 points were within 20cm among 16 points. In vertical accuracy test, 41 GCPs were used and it shows 11cm average and 14cm RMSE and 75% of GCPs were within 15cm. This could be a criterion in topographic map modification and basic geographic DB and 3D data construction using airborne LiDAR data.

  • PDF

Overloading Control Effectiveness of Overweight Enforcement System using High-Speed Weigh-In-Motion (고속축중기를 활용한 과적단속시스템의 과적 억제효과 분석)

  • Kwon, Soon-Min;Jung, Young-Yoon;Lee, Kyung-Bae
    • International Journal of Highway Engineering
    • /
    • v.14 no.5
    • /
    • pp.179-188
    • /
    • 2012
  • PURPOSES: The aim of this study is to analyze overloading control effectiveness of enforcing overweighted vehicles using HS-WIM (High-Speed Weigh-in-Motion) at main lane of expressway. METHODS: To analyze the weight distribution statistically, HS-WIM system should has an appropriate weighing accuracy. Thus, the weighing accuracy of the two HS-WIM systems was estimated by applying European specifications and ASTM (American Standards for Testing and Materials) for WIM in this study. Based on the results of accuracy test, overweight enforcement system has been operated at main lanes of two expressway routes in order to provide weight informations of overweighted vehicle in real time for enforcement squad. To evaluate the overloading control effectiveness with enforcement, traffic volume and axle loads of trucks for two months at the right after beginning of the enforcement were compared with data set for same periods before the enforcement. RESULTS: As the results of weighing accuracy test, both WIM systems were accepted to the most precise type that can be useful to applicate not only statistical purpose but enforcing on overweight vehicles directly. After the enforcement, the rate of overweighted trucks that weighed over enforcement limits had been decreased by 27% compared with the rate before the enforcement. Especially, the rate of overweighted trucks that weighed over 48 tons had been decreased by 91%. On the other hand, in counterpoint to decrease of the overweighted vehicle, the rate of trucks that weighed under enforcement limits had been increased by 7%. CONCLUSIONS: From the results, it is quite clear that overloading has been controlled since the beginning of the enforcement.