• Title/Summary/Keyword: accuracy control

Search Result 4,388, Processing Time 0.028 seconds

A Study on a Moving Adaptive Grid Generation Method Using a Level-set Scheme (레벨셋법을 이용한 이동 집중격자 생성법에 대한 연구)

  • Il-Ryong Park;Ho-Hwan Chun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.39 no.3
    • /
    • pp.18-27
    • /
    • 2002
  • In order to improve the accuracy of the solution near the boundary in an analysis of viscous flow around an arbitrary boundary which move and be deformed using an Eulerian concept, a level-set based grid deformation method is introduced to concentrate grid points near the boundary. This paper presents a new monitor function which can easily control the level of the concentration of grid points along the boundary. Computations for steady flow around a semi-circular cylinder mounted on the bottom of the flow domain were carried out to check the improvement of the solution using the adaptive grid system with an immersed boundary method. The present numerical results show a good agreement with the solutions obtained by a body fitted grid system and more accurate solutions than those computed with non-adaptive grid system. For the validation of mechanical usefulness of the present method, an expanded analysis of flow around multi-body fixed in the flow domain was carried out. Finally, the present moving adaptive grid method was applied to a two-dimensional bubble rise problem. The computed results show well adapted grid points around the boundary of the bubble at every time and a good agreement with the result calculated by fixed grid system.

A Study on Standardization of Shinbaro Pharmacopuncture Using Herbal Medicines Identification Test and HPLC-DAD (신바로 약침의 한약재 확인시험 및 HPLC-DAD를 통한 표준화 연구)

  • Lee, Jin Ho;Kim, Min Jeong;Lee, Jae Woong;Kim, Me Riong;Lee, In Hee;Kim, Eun Jee
    • Journal of Acupuncture Research
    • /
    • v.32 no.2
    • /
    • pp.1-9
    • /
    • 2015
  • Objectives : The present study was an evaluation and standardization of herbal components in order to establish the efficacy and safety of Shinbaro pharmacopuncture. Methods : Among the raw materials of Shinbaro pharmacopuncture, the components Cibotii Rhizoma, Eucommiae Cortex, and Ledebouriellae Radix were assessed through ingredient verification experiments using thin-layer chromatography(TLC) and ultraviolet rays(UV) lamps. In addition, we standardized Acanthopanacis Cortex and Achyranthis Radix through validation using high performance liquid chromatograph-diode array detector(HPLC-DAD). Results : As result appeared a blue-white fluorescence under ultraviolet rays; changed to dark green after adding 1 % ferric chloride solution(due to Cibotii Rhizoma), and presented a yellow-green fluorescence when mixed with an ethyl ether under UV lamps by way of the ethyl ether layer, confirming Eucommiae Cortex. Ledebouriellae Radix was confirmed as dark brown spots at Rf values of 0.56 and 0.71 using TLC. Additionally, Acanthopanacis Cortex and Achyranthis Radix HPLC test results showed that linearity was $R^2{\geq}0.99$, and detection limit and quantitation limit were 0.23 to $1.29{\mu}g/mL$, and 0.71 to $3.90{\mu}g/mL$, respectively. Furthermore, precision and accuracy were confirmed to have relative standard deviation(RSD) values of 0.10 to 1.89 % and 96.19 to 103.72 %, respectively. Shinbaro pharmacopuncture did not have any overlapping or interference from other peaks in detection under the abovementioned analysis conditions. Conclusions : In conclusion, we confirmed that maintenance of Shinbaro pharmacopuncture validity was possible by means of quality control of Cibotii Rhizoma, Eucommiae Cortex, and Ledebouriellae Radix through ingredient identification and Acanthopanacis Cortex and Achyranthis Radix through high performance liquid chromatograph(HPLC) analysis. Further, we hope to contribute to the development strategy of herbal industry acupuncture.

Gaze Detection by Computing Facial and Eye Movement (얼굴 및 눈동자 움직임에 의한 시선 위치 추적)

  • 박강령
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.2
    • /
    • pp.79-88
    • /
    • 2004
  • Gaze detection is to locate the position on a monitor screen where a user is looking by computer vision. Gaze detection systems have numerous fields of application. They are applicable to the man-machine interface for helping the handicapped to use computers and the view control in three dimensional simulation programs. In our work, we implement it with a computer vision system setting a IR-LED based single camera. To detect the gaze position, we locate facial features, which is effectively performed with IR-LED based camera and SVM(Support Vector Machine). When a user gazes at a position of monitor, we can compute the 3D positions of those features based on 3D rotation and translation estimation and affine transform. Finally, the gaze position by the facial movements is computed from the normal vector of the plane determined by those computed 3D positions of features. In addition, we use a trained neural network to detect the gaze position by eye's movement. As experimental results, we can obtain the facial and eye gaze position on a monitor and the gaze position accuracy between the computed positions and the real ones is about 4.8 cm of RMS error.

Fabrication of the Wafer Level Packaged LED Integrated Temperature Sensor and Configuration of The Compensation System for The LED's Optical Properties (온도센서가 집적된 WLP LED의 제작과 이를 통한 광 특성 보상 시스템의 구현)

  • Kang, In-Ku;Kim, Jin-Kwan;Lee, Hee-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.7
    • /
    • pp.1-9
    • /
    • 2012
  • In this paper, resistance temperature detector (RTD) integrated into the LED package is proposed in order to solve the temperature dependence of LED's optical properties. To measure the package temperature in real time, the RTD type temperature sensor having excellent accuracy and linearity between temperature change and resistance change was adopted. A stable metallic film is required for long term reliability and stability of the RTD type temperature sensor. Therefore, deposition and annealing condition for the film were determined. Based on the determined condition, the RTD type temperature sensor with the sensitivity of about $1.560{\Omega}/^{\circ}C$ was fabricated inside the LED package. In order to configurate the LED package system keeping the constant brightness regardless of the temperature, additional conversion circuit and control circuit boards were fabricated and added to the fabricated LED package. The proposed system was designed to compensate the light intensity caused by temperature change using the variable duty rate of driving current. As a result, the duty rate of PWM signal which is the output signal of the configurated system was changed with the temperature change, and the duty rate was similarly varied with the target duty rate. Consequently, it was focused the fabricated RTD can be used for compensating the optical properties of LED and the LED package which exhibits constant brightness regardless of the temperature change.

Derivation of Data Quality Attributes and their Priorities Based on Customer Requirements (고객의 요구사항에 기반한 데이터품질 평가속성 및 우선순위 도출)

  • Jang, Kyoung-Ae;Kim, Ja-Hee;Kim, Woo Je
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.12
    • /
    • pp.549-560
    • /
    • 2015
  • There is a wide variety of data quality attributes such as the ones proposed by the ISO/IEC organization and also by many other domestic and international institutions. However, it takes considerable time and costs to apply those criteria and guidelines to real environment. Therefore, it needs to define data quality evaluation attributes which are easily applicable and are not influenced by organizational environment limitations. The purpose of this paper is to derive data quality attributes and order of their priorities based on customer requirements for managing the process systematically and evaluating the data quantitatively. This study identifies the customer cognitive constructs of data quality attributes using the RGT(Repertory Grid Technique) based on a Korean quality standard model (DQC-M). Also the correlation analysis on the identified constructs is conducted, and the evaluation attributes is prioritized and ranked using the AHP. As the results of this paper, the consistent system, the accurate data, the efficient environment, the flexible management, and the continuous improvement are derived at the first level of the data quality evaluation attributes. Also, Control Compliance(13%), Regulatory Compliance(10%), Requirement Completeness(9.6%), Accuracy(8.4%), and Traceability(6.8%) are ranked on the top 5 of the 19 attributes in the second level.

Development of Dissolution Testing Method for Piracetam Tablets and Fenoterol Hydrobromide Tablets in Korean Pharmaceutical Codex (고시 수재 의약품 중 피라세탐 정 및 브롬화수소산페노테롤 정의 용출시험법 개발)

  • Kim, Eun-Jung;Lee, Jin-Ha;Park, Chan-Ho;Sohn, Kyung-Hee;Kim, In-Kyu;Kim, Dong-Sup;Sah, Hong-Kee;Choi, Hoo-Kyun
    • YAKHAK HOEJI
    • /
    • v.55 no.4
    • /
    • pp.324-331
    • /
    • 2011
  • Although the dissolution test can serve as an effective tool for quality control and predictor of in vivo performance, there are a number of drugs with no established dissolution specifications in Korean Pharmaceutical Codex (KPC). Among those commercially available, Piracetam Tablets and Fenoterol hydrobromide Tablets were selected to develop the dissolution testing method. The dissolution condition was determined based on the "Guidelines on Specifications of Dissolution tests for Oral dosage forms" of Korea Food & Drug Administration (KFDA). The dissolution test for Piracetam Tablets was carried out under sink condition with distilled water as dissolution medium, paddle rotation speed at 50 rpm and medium volume of 900 ml. More than 80% of its label claim was released within 30 min. In case of Fenoterol hydrobromide Tablets, distilled water was also found to be suitable to ensure sink condition. The rotation speed of 50 rpm and 900 ml of dissolution medium were used to evaluate the dissolution profile. The dissolution rate of fenoterol hydrobromide was over 90% in 15 min. The HPLC analysis methods were validated in terms of accuracy, precision, specificity, linearity, quantitation limit and range. The results suggested that the analytical methods used are simple and suitable to measure the dissolution rate of piracetam and fenoterol hydrobromide. Therefore, the analysis methods could be utilized in setting dissolution specifications of Piracetam Tablets and Fenoterol hydrobromide Tablets in the revised version of KPC.

A Study on FPGA Design for Rotating LED Display Available Video Output (동영상 표출이 가능한 회전 LED 전광판을 위한 FPGA 설계에 관한 연구)

  • Lim, Young-Sik;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.168-175
    • /
    • 2015
  • In this paper, we propose FPGA design technique for rotating LED display device which is capable of displaying videos with the use of the afterimage effect. The proposed technique is made up of image data correction process based on inverse gamma correction and error diffusion, block interleaving process, and data serial output process. The data correction process based on inverse gamma correction and error diffusion is an image data correction step in which image data received are corrected by inverse gamma correction process to convert the data into linear brightness characteristics, and by error diffusion process to reduce the brightness reduction phenomenon in low-gray-level which is caused by inverse gamma correction. In the block interleaving process, the data of the frames entered transversely are first saved in accordance with entrance order, and then only the longitudinal image data are read. The data serial output process is applied to convert the parallel data in a rotating location into serial data and send them to LED Driver IC, in order to send data which will be displayed on high-speedy rotating LED Bar. To evaluate the accuracy of the proposed FPGA design technique, this paper used XC6SLX45-FG484, a Spartan 6 family of Xilinx, as FPGA, and ISE 14.5 as a design tool. According to the evaluation analysis, it was found that goal values were consistent with simulation values in terms of accurate operation of inverse gamma and error diffusion correction, block interleaving operation, and serialized operation of image data.

A Comparative Study of Endotracheal Aspirates and Protected Specimen Brush in the Quantitative Cultures of the Ventilator-Associated Pneumonia (기계호흡기 관련 폐렴환자의 정량적 배양에 있어서 Endotracheal Aspirates과 Protected Specimen Brush의 비교 관찰)

  • Roo, Kyoung-Ryeol;Kim, Min-Gu;Kim, Gi-Yang;Jung, Ho-Gyeong;Park, Young-Ho;Kang, Byeng-Sun;Kim, Ho-Chul;Hwang, Young-Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.737-743
    • /
    • 1995
  • Background: Pneumonia is a frequent complication in patients undergoing mechanical ventilation, Quantitative culture of protected specimen brush(PSB) have shown satisfactory diagnostic accuracy for the diagnosis of ventilator-associated pneumonia. However PSB method is invasive, expensive, and require a bronchoscopic procedure. But endotracheal aspiration(EA) is simple and less expensive. The purpose of our study was to investigate the diagnosic value of EA quantitative cultures. Method: We studied 15 cases of ventilator-associated pneumonia(for >72h of mechanical ventilation) patients. Patients were divided into two diagnostic categories. Group I was the patients who were suspicious of clinical pneumonia, Group II was the patients for control. The obtained samples by EA and PSB were homogenized for quantitative culture with a calibrated loop method in all patients. Result: Using $10^3cfu/ml$, $10^5cfu/ml$ as threshold in quantitative culture of PSB, EA respectively, we found that EA quantitative cultures represented a relatively sentive(70%) and relatively specific (60%) method to diagnose the ventilator-associated pneumonia. Conclusion: Although EA quantitative cultures are less specific than PSB for diagnosing ventilator-associated pneumonia. EA quantitative cultures correlated with PSB quantitative culture in patients with clinical pneumonia and may be used to treat these patients when bronchoscopic procedures are not available.

  • PDF

KrF 엑시머 레이저를 이용한 웨이퍼 스텝퍼의 제작 및 성능분석

  • 이종현;최부연;김도훈;장원익;이용일;이진효
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.15-21
    • /
    • 1993
  • This paper describes the design and development of a KrF excimer laser stepper and discusses the detailed system parameters and characterization data obtained from the performance test. We have developed a deep UV step-and-repeat system, operating at 248 nm, by retrofitting a commercial modules such as KrF excimer laser, precision wafer stage and fused silica illumination and 5X projection optics of numerical aperture 0.42. What we have developed, to the basic structure, are wafer alignment optics, reticle alignment system, autofocusing/leveling mechanisms and environment chamber. Finally, all these subsystem were integrated under the control of microprocessor-based controllers and computer. The wafer alignment system comprises the OFF-AXIS and the TTL alignment. The OFF-AXIS alignment system was realized with two kinds of optics. One is the magnification system with the image processing technique and the other is He-Ne laser diffraction type system using the alignment grating on the wafer. 'The TTL alignment system employs a dual beam inteferometric method, which takes advantages of higher diffraction efficiency compared with other TTL type alignment systems. As the results, alignment accuracy for OFF-AXIS and TTL alignment system were obtained within 0.1 $\mu\textrm{m}$/ 3 $\sigma$ for the various substrate on the wafers. The wafer focusing and leveling system is modified version of the conventional systems using position sensitive detectors (PSD). This type of detection method showed focusing and leveling accuracies of about $\pm$ 0.1 $\mu\textrm{m}$ and $\pm$ 0.5 arcsec, respectively. From the CD measurement, we obtained 0.4 $\mu\textrm{m}$ resolution features over the full field with routine use, and 0.3 $\mu\textrm{m}$ resolution was attainable under more strict conditions.

  • PDF

A Study on Geoid Model Development Method in Philipphines (필리핀 지오이드모델의 개발방안 연구)

  • Lee, Suk-Bae;Pena, Bonifasio Dela
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.6
    • /
    • pp.699-710
    • /
    • 2009
  • If a country has her geoid model, it could be determine accurate orthometric height because the geoid model could provide continuous equi-gravity potential surface. And it is possible to improve the coordinates accuracy of national control points through geodetic network adjustment considering geoidal heights. This study aims to find the best way to develop geoid model in Philippines which have similar topographic conditions as like Malaysia and Indonesia in Eastsouth asia. So, in this study, it is surveyed the general theories of geoid determination and development cases of geoid model in Asia and it is computed that the geoidal heights and gravity anomalies by spherical harmonic analysis using EGM2008, the latest earth geopotential model. The results show that first, the development of gravimetric geoid model based on airborne gravimetry is needed and second, about 200 GPS surveying data at national benchmark is needed. It is concluded that it is the most reasonable way to develop the hybrid geoid model through fitting geometric geoid by GPS/leveling data to gravimetric geoid. Also, it is proposed that four band spherical Fast fourier transformation(FFT) method for evaluation of Stokes integration and remove and restore technique using EGM2008 and SRTM for calculation of gravimetric geoid model and least square collocation algorithm for calculation of hybrid geoid model.