• Title/Summary/Keyword: accuracy analysis

Search Result 11,955, Processing Time 0.035 seconds

A Transient Response Analysis in the State-space Applying the Average Velocity Concept (평균속도 개념을 적용한 상태공간에서의 과도응답해석)

  • 김병옥;김영철;김영춘;이안성
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.5
    • /
    • pp.424-431
    • /
    • 2004
  • An implicit direct-time integration method for obtaining transient responses of general dynamic systems is described. The conventional Newmark method cannot be directly applied to state-space first-order differential equations, which contain no explicit acceleration terms. The method proposed here is the state-space Newmark method that incorporates the average velocity concept, and can be applied to an analysis of general dynamic systems that are expressed by state-space first-order differential equations. It is also readily coded into a program. Stability and accuracy analyses indicate that the method is numerically unconditionally stable like the conventional Newmark method, and has a period error of 2nd-order accuracy for small damping and 4th-order for large damping and an amplitude error of 2nd-order, regardless of damping. In addition, its utility and validity are confirmed by two application examples. The results suggest that the proposed state-space Newmark method based on average velocity be generally applied to the analysis of transient responses of general dynamic systems with a high degree of reliability with respect to stability and accuracy.

The Accuracy Design of LM Guide System in Machine Tools (공작기계 직선 베어링 안내면의 정도 설계에 관한 연구)

  • 김경호;박천홍;송창규;이후상;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.692-695
    • /
    • 2000
  • This paper is concerned with Accuracy Design of LM Guide System in Machine Tools. Elastic deformation of bearing is calculated by Hertz contact theory and motion error of LM block is analyzed. A new algorithm using block stiffness is proposed fur the analysis of motion accuracy of the table. The best advantage of this algorithm is fast analysis speed because it isn't necessary iteration processes for satisfying equilibrium equation of the table. Motion errors of the table analyzed under artificial form error of rail theoretically and experimentally. Only one of two rails is bent by putting a thickness gauge into horizontal direction. This form error of rail is measured by gap sensor against the other rail. Then, motion errors of the table are predicted by proposed new algorithm theoretically and measured by laser interferometer. Measurements are carried out by changing the preload and thickness. The results show that the table motion errors are reduced from 1/2 to 1/60 times than form error of rail according to its height and width. And the effect of preloading is almost negligible.

  • PDF

A study on the Accurate Comparison of Nonlinear Solution Which Used Tangent Stiffness Equation and Nonlinear Stiffness Equation (접선 강성방정식과 비선형 강성방정식을 이용한 비선형 해의 정확성 비교에 관한 연구)

  • Kim, Seung-Deog;Kim, Nam-Seok
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.2
    • /
    • pp.95-103
    • /
    • 2010
  • This paper study on the accuracy improvement of nonlinear stiffness equation. The large structure must have thin thickness for build the large space structure there fore structure instability review is important when we do structural design. The structure instability of the shelled structure is accept it sensitively by varied conditions. This come to a nonlinear problem with be concomitant large deformation. Accuracy of nonlinear stiffness equation must improve to examine structure instability. In this study, space truss is analysis model Among tangent stiffness equation and nonlinear stiffness equation is using nonlinearity analysis program. The study compares an analysis result to investigate accuracy and convergence properties improvement of nonlinear stiffness equation.

  • PDF

Development of Simple Articulated Human Models using Superquadrics for Dynamic Analysis

  • Lee, Hyun-Min;Kim, Jay-Jung;Chae, Je-Wook
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.6
    • /
    • pp.715-725
    • /
    • 2011
  • Objective: This study is aimed at developing Articulated Human Models(AHM) using superquadrics to improve the geometric accuracy of the body shape. Background: The previous work presents the AHM with geometrical simplification such as ellipsoids to improve analysis efficiency. However, because of the simplicity, their physical properties such as a center of mass and moment of inertia are computed with errors compared to their actual values. Method: This paper introduces a three steps method to present the AHM with superquadrics. First, a 3D whole body scan data are divided into 17 body segments according to body joints. Second, superquadric fitting is employed to minimize the Euclidean distance between body segments and superquadrics. Finally, Fee-Form Deformation is used to improve accuracy over superquadric fitting. Results: Our computational experiment shows that the superquadric models give better accuracy of dynamic analysis than that of ellipsoid ones. Conclusion: We generate the AHM composed of 17 superquadrics and 16 joints using superquadric fitting. Application: The AHM using superquadrics can be used as the base model for dynamics and ergonomics applications with better accuracy because it presents the human motion effectively.

A Study on the Adequacy Awareness of Computed Tomography Equipment Quality Control (전산화단층촬영장비 정도관리의 적정 인지도에 관한 연구)

  • Kim, Gyoo Hyung;Lim, Cheong Hwan;Kim, Ki Jeong
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.31-37
    • /
    • 2019
  • Investigate the adequacy awareness of accuracy control of CT apparatus Questionnaire survey and statistical analysis in the analysis according to age, there is a difference between familiarity with accuracy management items (F = 14.187, p<0.001) and necessity of accuracy control (F=8.109, p<0.001), depending on academic background and work history, There is a difference only in familiarity (F=5.103, p<0.05, F=13.394, p<0.001), and according to the scale of the medical institution analysis shows that if you are more interested than senior general hospital grade hospital grade or less It was analyzed. In order to advance the accuracy control level, we have introduced our comprehensive and efficient comprehensive and efficient integrated medical image quality management operation system of the whole medical image equipment including CT device, It is thought that it is necessary to develop human resources capable of doing.

Land Cover Classification Map of Northeast Asia Using GOCI Data

  • Son, Sanghun;Kim, Jinsoo
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.1
    • /
    • pp.83-92
    • /
    • 2019
  • Land cover (LC) is an important factor in socioeconomic and environmental studies. According to various studies, a number of LC maps, including global land cover (GLC) datasets, are made using polar orbit satellite data. Due to the insufficiencies of reference datasets in Northeast Asia, several LC maps display discrepancies in that region. In this paper, we performed a feasibility assessment of LC mapping using Geostationary Ocean Color Imager (GOCI) data over Northeast Asia. To produce the LC map, the GOCI normalized difference vegetation index (NDVI) was used as an input dataset and a level-2 LC map of South Korea was used as a reference dataset to evaluate the LC map. In this paper, 7 LC types(urban, croplands, forest, grasslands, wetlands, barren, and water) were defined to reflect Northeast Asian LC. The LC map was produced via principal component analysis (PCA) with K-means clustering, and a sensitivity analysis was performed. The overall accuracy was calculated to be 77.94%. Furthermore, to assess the accuracy of the LC map not only in South Korea but also in Northeast Asia, 6 GLC datasets (IGBP, UMD, GLC2000, GlobCover2009, MCD12Q1, GlobeLand30) were used as comparison datasets. The accuracy scores for the 6 GLC datasets were calculated to be 59.41%, 56.82%, 60.97%, 51.71%, 70.24%, and 72.80%, respectively. Therefore, the first attempt to produce the LC map using geostationary satellite data is considered to be acceptable.

Accuracy-based Evaluation of the Utilization of Spatial Information for BIM Application (BIM 적용을 위한 공간정보의 정확도 기반 활용성 평가)

  • Doo-Pyo Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.669-678
    • /
    • 2023
  • Recently, spatial information has been applied to various fields and its usability is increasing day by day. In particular, in the field of civil engineering and construction, BIM based on spatial information is being applied to all construction industries and related research has been conducted. BIM is a technology that utilizes spatial information from the design phase and aids in the construction and maintenance of buildings, including the management of their attributes. However, to apply BIM technology to existing buildings, it takes a lot of time and money to produce models based on design drawings along with current surveying. In this study, quantitative and qualitative analysis was conducted to determine the applicability of the acquired data and the applicability of BIM by generating data and analyzing the accuracy using UAV images and ground lidar, which are representative spatial information acquisition methods. Quantitative analysis revealed that TLS (Terrestrial Laser Scanner) showed reliable accuracy in both planar and elevation measurements, whereas unmanned aerial images exhibited lower accuracy in elevation measurements, resulting in reduced reliability. Qualitative analysis indicated that neither TLS nor unmanned aerial images alone provided perfect completeness. However, the combination of both spatial information sources, tailored to specific needs, resulted in the most comprehensive completeness. Therefore, it is concluded that the appropriate utilization of spatial information acquired through unmanned aerial images and TLS holds the potential for application in the fields of BIM and reverse engineering.

Postal Dosimetry Audits for the Domestic Medical Linear Accelerator

  • Kim, Kum Bae;Choi, Sang Hyoun
    • Progress in Medical Physics
    • /
    • v.31 no.2
    • /
    • pp.20-28
    • /
    • 2020
  • Purpose: The objective of this study is to perform Postal dosimetry audits for medical linear accelerators in radiation therapy institutions using glass dosimeters and Gafchromic film reading systems and postal dosimetry audit procedures, and to evaluate radiation therapy doses and mechanical accuracy in medical institutions. Methods: Photon output measured and analyzed using a standard phantom for measuring photon output dose using a glass dosimeter for medical linear accelerators. Mechanical accuracy was measured and analyzed using software for film measurement. Results: Measurement and analysis of photon beam output dose using a standard phantom glass dosimeter for photon beam output dose measurement was completed. All tolerance doses were within 5%. Mechanical accuracy measurement and analysis using a standard phantom for verifying the mechanical accuracy of linear accelerator (LINAC) using a Gafchromic film were completed, and all results were shown within tolerances (2 mm or less). Conclusions: In this study, Postal dosimetry audits were performed on the output dose and mechanical accuracy of photon beams (207 beams) for 106 LINACs from 48 institutions. As a result of corrective action and re-execution, it was confirmed that all engines met the acceptable standard within 2 mm in the linear accelerator.

A Measuring Method for Positioning Characteristics Analysis of NC Machine Controller using Dynamometer (모터 동력계를 이용한 공작기계용 NC제어기 시스템의 위치제어 특성 분석을 위한 측정 연구)

  • Kim Hyung Gon;An Dong Youl;Lee Eung Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.5 s.236
    • /
    • pp.770-776
    • /
    • 2005
  • The gains fur NC controller parameter are fixed when the controller is combined with a machine. However, the characteristics of controller could be changed as it has being used by the machine or other environmental conditions. Those result in that the tool positioning accuracy is influenced. The loading torque in servo motor influences on the tool positioning accuracy and it is controlled by the parameter gains. It is required to analyze the torque variation with angular positioning accuracy of the servo motor. This study focus on a measuring method and device for verifying angular positioning accuracy of NC servo motor. We used a high resolution An converter for acquiring analogue signal of rotary encoder in servo motor. The positional accuracy for a nominal tool path, which is generated by the combination of axial movements (X,Y,Z), is analyzed with the servo motor torque. The current variation signal is acquired at the power line using a hall sensor and converted to the loading torque of servo motor. The method of measurement and analysis proposed in this study will be used for determining the gains of parameter in NC controller. This gain tuning is also necessary when the controller is set up at a machine.

Analysis of DGPS Approach and Landing Accuracy using Air Base Precision Approach Radar (비행기지 PAR을 이용한 DGPS 공항 접근 및 착륙 정확도 분석)

  • Koo, Jung;Pyo, Sang-Ho;Kang, Kyeong-Sung;Kim, Ki-Hyung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.788-797
    • /
    • 2011
  • This paper analyzes the accuracy on the approach and landing of aircraft to an airport through comparison with airbase Precision Approach Radar and aircraft track data of DGPS equipped in aircraft. The proposed analysis result could be a basis for verifying the possibility that DGPS can be utilized in Airbase precision approach and landing. Position identification capability of widely used commercial DGPS is fairly accurate on latitude and longitude, while there is a slight error for being used in an airbase accurate approach and landing of Category I precision when it comes to altitude. Thus, we tested accuracy by analyzing actual flight track data of high performance aircraft to verify the accuracy of the airbase approach and landing using DGPS. Through the research, we developed instrumentation to compare PAR track data with DGPS track data, which can be used in reducing the number of PAR verification Flight utilizing it as a system measuring PAR accuracy at PAR installation phase.