• Title/Summary/Keyword: accuracy analysis

Search Result 11,955, Processing Time 0.042 seconds

Analysis of Drone Surveying Using a Low-Cost PPK Kit (PPK Kit를 활용한 드론 측량 분석)

  • Park, Junho;Kim, Taerim
    • Journal of The Geomorphological Association of Korea
    • /
    • v.28 no.4
    • /
    • pp.41-52
    • /
    • 2021
  • With the popularization of drones and the ease of use of the Global Navigation Satellite System (GNSS), drone photogrammetry for terrain information has been widely used. Drone photogrammetry enables the realization of high-accuracy three-dimensional topography for the entire area with less effort and time compared to the past direct survey using GNSS or total station. From 3-D topographic data, various topographical analysis is possible. To improve the accuracy of drone photogrammetry, direct GCP surveying in the field is essential, and the numbers and reasonable positioning of GCPs are very important. In the case of beaches or tidal flats on the west coast of Korea, the numbers and location of GCPs are important factors in efficient drone photogrammetry because of the size of the area, difficulties of movement, and the risk from tides. If the RTK (Real-time kinematic) or PPK (Post-processed kinematic) method is used, the increased accuracy of the drone's location enables high-accuracy photogrammetry with a small number of GCPs. This study presents an efficient drone photogrammetry method in terms of time and economy by comparing and analyzing the results of drone photogrammetry using Non-PPK with low-cost PPK-Kit, based on the tests of various numbers and locations of GCPs in the university field including various slopes and structures like coastal terrain.

Diagnostic Accuracy of Lactate Dehydrogenase/Adenosine Deaminase Ratio in Differentiating Tuberculous and Parapneumonic Effusions: A Systematic Review

  • Larry Ellee Nyanti;Muhammad Aklil Abd Rahim;Nai-Chien Huan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.1
    • /
    • pp.91-99
    • /
    • 2024
  • Background: Tuberculous pleural effusion (TPE) and parapneumonic effusion (PPE) are often difficult to differentiate owing to the overlapping clinical features. Observational studies demonstrate that the ratio of lactate dehydrogenase to adenosine deaminase (LDH/ADA) is lower in TPE compared to PPE, but integrated analysis is warranted. Methods: We conducted a systematic review to evaluate the diagnostic accuracy of the LDH/ADA ratio in differentiating TPE and PPE. We explored the PubMed and Scopus databases for studies evaluating the LDH/ADA ratio in differentiating TPE and PPE. Results: From a yield of 110 studies, five were included for systematic review. The cutoff value for the LDH/ADA ratio in TPE ranged from <14.2 to <25. The studies demonstrated high heterogeneity, precluding meta-analysis. Quality Assessment of Diagnostic Accuracy Studies Tool 2 assessment revealed a high risk of bias in terms of patient selection and index test. Conclusion: LDH/ADA ratio is a potentially useful parameter to differentiate between TPE and PPE. Based on the limited data, we recommend an LDH/ADA ratio cutoff value of <15 in differentiating TPE and PPE. However, more rigorous studies are needed to further validate this recommendation.

Noise Characteristic Analysis of X-Ray Fluorescence Spectrum (형광 X-선 스펙트럼의 잡음 특징 분석)

  • Lee, Jae-Hwan;Chon, Sun-Il;Yang, Sang-Hoon;Park, Dong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2298-2304
    • /
    • 2012
  • X-ray fluorescence spectrum analysis method can be applied in many areas, including concentration analysis of RoHS elements and heavy metals etc. and we can get analysis results in a relatively short time. Because X-ray fluorescence spectrum has noises and several artifacts that lowers the accuracy of the analysis. This paper analyzes the characteristics of the noise of the X-ray fluorescence spectrum to increase the accuracy of analysis. X-ray fluorescence spectrum have the characteristics of shot noise (Poisson noise), so the noise size is relatively large in the small signal portion and the noise the size is relatively small in the large part of the signal. Existing methods of analysis and to remove noises is a method for general purposes algorithm. Since these algorithm does not reflect these noise characteristics, we get distorted analysis result. We can design efficient noise remove algorithm based on the accurate noise analysis method, and we expect high accuracy results of the elemental concentration analysis result.

Relationship between Result of Sentiment Analysis and User Satisfaction -The case of Korean Meteorological Administration- (감성분석 결과와 사용자 만족도와의 관계 -기상청 사례를 중심으로-)

  • Kim, In-Gyum;Kim, Hye-Min;Lim, Byunghwan;Lee, Ki-Kwang
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.10
    • /
    • pp.393-402
    • /
    • 2016
  • To compensate for limited the satisfaction survey currently conducted by Korea Metrological Administration (KMA), a sentiment analysis via a social networking service (SNS) can be utilized. From 2011 to 2014, with the sentiment analysis, Twitter who had commented 'KMA' had collected, then, using $Na{\ddot{i}}ve$ Bayes classification, we were classified into three sentiments: positive, negative, and neutral sentiments. An additional dictionary was made with morphemes appeared only in the positive, negative, and neutral sentiments of basic $Na{\ddot{i}}ve$ Bayes classification, thus the accuracy of sentiment analysis was improved. As a result, when sentiments were classified with a basic $Na{\ddot{i}}ve$ Bayes classification, the training data were reproduced about 75% accuracy rate. Whereas, when classifying with the additional dictionary, it showed 97% accuracy rate. When using the additional dictionary, sentiments of verification data was classified with about 75% accuracy rate. Lower classification accuracy rate would be improved by not only a qualified dictionary that has increased amount of training data, including diverse keywords related to weather, but continuous update of the dictionary. Meanwhile, contrary to the sentiment analysis based on dictionary definition of individual vocabulary, if sentiments are classified into meaning of sentence, increased rate of negative sentiment and change in satisfaction could be explained. Therefore, the sentiment analysis via SNS would be considered as useful tool for complementing surveys in the future.

Accuracy and Consistency of Three-Dimensional Motion Analysis System (3차원 동작분석 시스템의 정밀도와 측정 일관성)

  • Park, Young-Hoon;Youm, Chang-Hong;Seo, Kook-Woong
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.2
    • /
    • pp.83-92
    • /
    • 2005
  • Computer-assisted motional analysis is a popular method in biomechanical studies. Validation of the specific system and its measurement are fundamental to its application in the areas. Because the accuracy and consistency of a particular system provide the researchers with critical information to assist in making judgements regarding the degree to which inferences can be drawn from measurement data. The purpose of this study was to assess the accuracy and consistency of the Kwon3D motion analysis system. Validation parameters were five lengths from eight landmarkers in combination with the DLT reconstruction error values, digitizing monitor resolutions, and numbers of control points. With the best setting, Kwon3D's estimations of 260cm, 200cm, 140cm, 100cm, and 20cm were $260.33{\pm}.688cm$, $199.98{\pm}.625cm$, $139.89{\pm}.537cm$, $99.75{\pm}.466cm$, $20.08{\pm}.114$, respectively. There was no significant DLT error value difference between two monitor resolutions, but 0.27cm significant difference in 260cm estimation. There were significant differences in 260cm and 200cm estimations between with 33-control-point DLT error and with 17-control-point DLT error, but no in 140cm, 100cm, and 20cm estimations. Test-retest results showed that Kwon3D measurements were highly consistent with reliability coefficients alpha of .9263 and above.

Analysis of Network-RTK(VRS) Positioning Accuracy for Surveying Public Control Point (공공기준점 측량에 적용을 위한 VRS(가상기준점) 방식의 Network-RTK 정확도 분석)

  • Han, Joong-Hee;Kwon, Jay-Hyoun;Hong, Chang-Ki
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.18 no.2
    • /
    • pp.13-20
    • /
    • 2010
  • Currently, NGII(National Geographic Information Institute) provides VRS(Virtual Reference System) service using 44 CORS(Continuously Operating Reference Stations). Since the VRS provides high-precision coordinate in a short time, the users and applications are expected to be rapidly increasing. The accuracy analysis on the VRS service, however, was not sufficiently performed yet. Therefore, in this study, the VRS data is acquired from various circumstances and its accuracy is analyzed. According to analysis, it was concluded that the VRS could be applied to public control point survey. Furthermore, it was found that the PQ(Position Quality) which represents variance of estimated coordinates rather than GDOP(Geometric Dilution of Precision) is more relevant as a factor to determine the accuracy of coordinates. Based on the analysis of data from four manufacturers (TRIMBLE, MAGELLAN, LECIA, TOPCON), it was confirmed that the standard deviations better than 3cm. Therefore, VRS Survey apply to public control point survey.

Use of Portable Global Positioning System (GPS) Devices in Exposure Analysis for Time-location Measurement

  • Lee, Ki-Young;Kim, Joung-Yoon;Putti, Kiran;Bennett, Deborah H.;Cassady, Diana;Hertz-Picciotto, Irva
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.6
    • /
    • pp.461-467
    • /
    • 2009
  • Exposure analysis is a critical component of determining the health impact of pollutants. Global positioning systems (GPS) could be useful in developing time-location information for use in exposure analysis. This study compares four low cost GPS receivers with data logging capability (Garmin 60, Garmin Forerunner 201, GeoStats GeoLogger and Skytrx minitracker MT4100) in terms of accuracy, precision, and ease of use. The accuracy of the devices was determined at two known National Geodetic Survey points. The coordinates logged by the devices were compared when the devices were carried while walking and driving. The Garmin 60 showed better accuracy and precision than the GeoLogger when they were placed at the geodetic points. The Forerunner and Skytrx did not record when they were kept stationary. When the subject wore the devices while walking, the location of the devices differed by about 8 m on average between any two device combinations involving the four devices. The distance between the coordinates logged by the devices decreased when the devices were carried with their antennas facing the sky. All the devices showed similar routes when they were used in a car. All the devices except the Forerunner had satisfactory signal reception when they were worn and when they were carried in the car. The GeoLogger is less comfortable for the subject because of specific wearing requirements. This evaluation found that the Garmin 60 and the Skytrx may be useful in personal exposure analysis studies to record time-location data.

Validity Study of the Questionnaire for Doctors for Sasang Constituion Diagnosis (의사용 체질진단지의 타당화 연구)

  • Kim Jong-Won;Jeong Seong-Il;Kim Kyu-Gon;Lee Eui-Ju;Kim Jong-Yul;Lee Yong-Tae
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.20 no.1
    • /
    • pp.209-214
    • /
    • 2006
  • This study is validity study of the questionnaire for doctors for Sasang constituion diagnosis. (an objects of this study : 314 patients) We analyzed the results of questionnaires about 314 patients who were diagnosed in Department of Sasang Constitutional Medicine from June to November, 2004. The questionnaire for doctors consists of objective valuation about the patients for Sasang constituion diagnosis. In the analysis about all variables, we obtain the diagnosis accuracy of 92%. In the analysis about body type variable, we obtain the diagnosis accuracy of 44-48%. In the analysis about external appearance, mental characteristics, physiology & pathologic symptoms variables, we obtain the diagnosis accuracy of 46-72%. After all, in order to increase of the diagnosis accuracy, we have to analysis total variables(body type, external appearance, mental characteristics, physiology & pathologic symptoms) for sasang constituion diagnosis. Hereafter, We need many data and standardization for sasang constituion diagnosis.

Measurement of the Volumetric Thermal Errors for CNC Machining Center Using the Star-type-styluses Tough Probe

  • Lee, Jae-Jong;Yang, Min-Yang
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.1 no.1
    • /
    • pp.111-117
    • /
    • 2000
  • One of the major limitations of productivity and quality in metal cutting is the machining accuracy of machine tools. The machining accuracy is affected by geometric errors, thermally-induced errors, and the deterioration of the machine tools. Geometric and thermal errors of machine tools should be measured and compensated to manufacture high quality products. In metal cutting, the machining accuracy is more affected by thermal errors than by geometric errors. This paper models the thermal errors for error analysis and develops an on-the-machine measurement system by which the volumetric errors are measured and compensated. The thermal error is modeled by means of angularity errors of a column and thermal drift error of the spindle unit which are measured by the touch probe unit with a star type styluses and a designed spherical ball artifact (SBA). Experiments show that the developed system provides a high measuring accuracy, with repeatability of $\pm$2$\mu\textrm{m}$ in X, Y and Z directions. It is believed that the developed measurement system can be also applied to the machine tools with CNC controller. In addition, machining accuracy and product quality can be also improved by using the developed measurement system when the spherical ball artifact is mounted on a modular fixture.

  • PDF

Diagnosis Accuracy Rate Comparative Study of Each Sasang Constitutions and Sex Distinction by Body Measurement Method between 3D Body Measuring Instrument and Hand-operating (3D체형측정기와 수동측정 방법간의 사상체질별 ${\cdot}$ 성별 진단정확률 비교연구)

  • Kwon, Suk-Dong;Sul, Yu-Kyung;Lee, Eui-Ju;Kim, Kyu-Kon;Kim, Jong-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.1
    • /
    • pp.60-77
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method and Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated Width 5 Places and hand-operated circumference 8 place,Automatic Width 5 and automatic circumference 8 place by 3D body measuring instrument) and analyzed the anthropometric data divding into sex&age. 362 patient's data are used in the analysis. 3. Results and Conclusions 1) 1th circumference variable which standing was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement was 50-80%. 3) Diagnostic accuracy rate of man is higher than Diagnostic accuracy rate of women 4) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF