DOI QR코드

DOI QR Code

Accuracy and Consistency of Three-Dimensional Motion Analysis System

3차원 동작분석 시스템의 정밀도와 측정 일관성

  • Published : 2005.06.30

Abstract

Computer-assisted motional analysis is a popular method in biomechanical studies. Validation of the specific system and its measurement are fundamental to its application in the areas. Because the accuracy and consistency of a particular system provide the researchers with critical information to assist in making judgements regarding the degree to which inferences can be drawn from measurement data. The purpose of this study was to assess the accuracy and consistency of the Kwon3D motion analysis system. Validation parameters were five lengths from eight landmarkers in combination with the DLT reconstruction error values, digitizing monitor resolutions, and numbers of control points. With the best setting, Kwon3D's estimations of 260cm, 200cm, 140cm, 100cm, and 20cm were $260.33{\pm}.688cm$, $199.98{\pm}.625cm$, $139.89{\pm}.537cm$, $99.75{\pm}.466cm$, $20.08{\pm}.114$, respectively. There was no significant DLT error value difference between two monitor resolutions, but 0.27cm significant difference in 260cm estimation. There were significant differences in 260cm and 200cm estimations between with 33-control-point DLT error and with 17-control-point DLT error, but no in 140cm, 100cm, and 20cm estimations. Test-retest results showed that Kwon3D measurements were highly consistent with reliability coefficients alpha of .9263 and above.

Keywords

References

  1. 이현섭, 김기형(2003). DLT를 이용한 3차원 공간검정시 RMSE에 대한 통계학적 분석. 한국운동역학회지, 13(1), 1-12.
  2. Das, G. B.(1949). A mathematical approach to problems in photogrammety. Empire Survey Review, Vol. X(73).
  3. Abdel-Aziz, Y. I. & Karara, H. M.(1971). Direct linear transformation from comparator coordinates into object-space coordinates in close-range photogra- mmetry. Proceedings of the ASP/UI Symposium on Close-Range Photogrammetry (pp.1-18). American Society of Photogrammetry, Falls Church, VA.
  4. Allard, P., Strokes, I.a.F., & Blanchi, J. P.(1995). Three-Dimensional Analysis of Human Movement. Champaign, IL: Human kinetics.
  5. Ambrosio, J., Lopes, G., Costa, J., & Abrantes, J.(2001). Spatial reconstruction of the human motion based on images of a single camera. Journal of Biomechanics, 34, 1217-1221. https://doi.org/10.1016/S0021-9290(01)00068-9
  6. Angulo, R. M. & Dapena, J.(1992). Comparison of film and video techniques for the estimating three-dimensional coordinates within a large field. International Journal of Sport Biomechanics, 8, 145-151.
  7. Baker, R.(1997). Assessment of the inherent acuracy of a kinematic analysis system. Gait and Posture, 5, 85.
  8. Borghese, N. A., Cerveri, P., & Ferrigno, G. C.(1997). Statistical comparison of DLT versus ILSSC in the calibration of a photogrammetric stereo-system. Journal of Biomechanics, 30, 409-413. https://doi.org/10.1016/S0021-9290(96)00145-5
  9. Chen, L., Amstrong, C. W., & Raftopoulos, D. D.(1994). An investigation on the accuracy of three-dimensional space reconstruction using the direct linear trasformation technique. Journal of Biomechanics, 27, 493-500. https://doi.org/10.1016/0021-9290(94)90024-8
  10. Ehara, Y., Fujimoto, H., Miyazaki, S., & Tanaka, S.(1995). Comparison of the performance of 3D camera systems. Gait and Posture, 3, 166-169. https://doi.org/10.1016/0966-6362(95)99067-U
  11. Ehara, Y., Fujimoto, H., Miyazaki, S., Mochimaru, M., Tanaka, S., & Yamamoto, S.(1997). Comparison of the performance of 3D camera systems II. Gait and Posture, 5, 251-255. https://doi.org/10.1016/S0966-6362(96)01093-4
  12. Eian J., & Poppele, R. E.(2002). A single-camera method for three-dimensional video imaging. Journal of Neuroscience Method, 120, 65-83 https://doi.org/10.1016/S0165-0270(02)00191-7
  13. Engler, P. E., Sisto, S. A., Redling, J., Andrews, J. F., Chang, T., & Findley, T. W.(1996). Measuring the accuracy of the 120Hz VICON 370 movement analysis system. Gait and Posture, 4, 192-193.
  14. Gazzani, D.(1993). Comparative assessment of two algorithms for calibrating sterophotogrammetric system. Journal of Biomechanics, 26, 1449-1454. https://doi.org/10.1016/0021-9290(93)90095-V
  15. Giorcelli, R. J., Hughes, R. E., Current, R. S., & Myers, J. R.(2004). Accuracy of a system for measuring three-dimensional torso kinematics during manual materials handling. Journal of Applied Biomechanics, 20, 185-194.
  16. Hatze, F.(1988). High-precision three-dimensional photo- grammetric calibration and object space recon- struction using a modified DLT-approach. Journal of Bio- mechanics, 21, 533-538.
  17. Hinriches, H., & McLean, R. N.(1995). NLT and extrapolated DT: 3-D cinematography alternatives for enlarging the volume of calibration. Journal of Biomechanics, 28, 1219-1223. https://doi.org/10.1016/0021-9290(95)00034-F
  18. Klein, P. J., & DeHaven, J. J.(1995). Accuracy of three-dimensional linear and angular estimates obtained with the Aerial Performance Analysis System. Achieves of Physical Medicine and Rehabilitation, 76(2), 183-189. https://doi.org/10.1016/S0003-9993(95)80028-X
  19. Marzan, G. T. & Karara, H. M.(1975). A computer program for direct linear transformation solution of collinearity condition, and some application of it. Proceedings of the ASP/UI Symposium on Close-Range Photo- grammetry Systems, Champaign. American Society of Photogrammetry, Falls Church, VA, pp.420-476.
  20. Pourcelot, P., Audigie, F., Degueurce, C., Geiger, D., & Denoix, J. M.(2000). A method to synchronise cameras using the direct linear transformation technique. Journal of Biomechanics, 33, 1751-1754. https://doi.org/10.1016/S0021-9290(00)00132-9
  21. Robbie, S., Attfield, S., & Taylor, D.(1996). Assessing the accuracy of 3-D kinematic data: Implications for laboratory set up. Gait and Posture, 4, 202.
  22. Tsai, R. T.(1987). A versatile camera calibration technique for high accuracy 3-D machine vision metrology using off-the-shelf TV cameras and lens. IEEE Journal of Robotics and Automation RA-3, 323-344.
  23. Wood, T. M., & Marshall, G. A.(1986). The accuracy of DLT extrapolation in three-dimensional film analysis. Journal of Biomechanics, 19, 781-785. https://doi.org/10.1016/0021-9290(86)90201-0
  24. Yeadon, M. R. & King, M. A.(1999). A method for synchronising digitised video data. Journal of Biomechanics, 32, 983-986. https://doi.org/10.1016/S0021-9290(99)00083-4