• 제목/요약/키워드: accumulation distance

검색결과 87건 처리시간 0.026초

DTW 최소누적거리를 이용한 심전도 이상 검출 알고리즘 구현 및 평가 (Implementation and Evaluation of Abnormal ECG Detection Algorithm Using DTW Minimum Accumulation Distance)

  • 노윤홍;이영동;정도운
    • 센서학회지
    • /
    • 제21권1호
    • /
    • pp.39-45
    • /
    • 2012
  • Recently the convergence of healthcare technology is used for daily life healthcare monitoring. Cardiac arrhythmia is presented by the state of the heart irregularity. Abnormal heart's electrical signal pathway or heart's tissue disorder could be the cause of cardiac arrhythmia. Fatal arrhythmia could put patient's life at risk. Therefore arrhythmia detection is very important. Previous studies on the detection of arrhythmia in various ECG analysis and classification methods had been carried out. In this paper, an ECG signal processing techniques to detect abnormal ECG based on DTW minimum accumulation distance through the template matching for normalized data and variable threshold method for ECG R-peak detection. Signal processing techniques able to determine the occurrence of normal ECG and abnormal ECG. Abnormal ECG detection algorithm using DTW minimum accumulation distance method is performed using MITBIH database for performance evaluation. Experiment result shows the average percentage accuracy of using the propose method for Rpeak detection is 99.63 % and abnormal detection is 99.60 %.

카올린 오손물 누적량 및 누설전류 변화에 관한 연구 (A Study on Kaolin Contaminant Accumulation Contents and Leakage Current Variation)

  • 박재준;송일근;이재봉
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.145-146
    • /
    • 2005
  • This study performs a simulation for an accumulation mechanism of contaminants, which were produced in an industrial belt of inland, on the surface of insulators. From the simulation, silicon insulators presented higher accumulation than that of EPDM(Ethylene Propylene Diene Terpolymer : EPDM) insulators on the same distance in the case of the Virgin polymer insulator, and this result presented the same result in the insulator applied in actual fields. In the case of the accumulation test for the Virgin insulator and insulators used in actual fields, it is evident that the Virgin insulator presented more accumulation than that of the insulator used in actual fields. The results can be caused by the generation of LMW (Low Molecular Weight) on the external material of polymer insulators, and the level of the accumulation can be changed according to the degree of the continuous generation of LMW.

  • PDF

가열된 표면에 고착된 한 쌍의 액적 증발 특성 (Evaporation Characteristics of Paired Sessile Droplets on a Heated Substrate)

  • 이형주;황원영;김정호;최창경;이성혁
    • 한국분무공학회지
    • /
    • 제28권3호
    • /
    • pp.113-118
    • /
    • 2023
  • This study investigates the evaporation characteristics of paired sessile droplets on a heated substrate. In particular, the evaporation time and contact line behaviors were analyzed based on the droplet-to-droplet distance and substrate temperature. The contact line behavior and volume variations were visualized using the shadowgraph method. It was observed that the contact diameter and contact angle exhibited similar behavior for both single and paired droplets regardless of the droplet-to-droplet distance and substrate temperature. The paired droplets demonstrated a longer evaporation time than the single droplet due to the vapor accumulation between the droplets. Furthermore, the scaled lifetime, defined as the ratio of evaporation time between paired and single droplets, increased as the droplet-to-droplet distance decreased and decreased as the substrate temperature increased, attributed natural convection.

초음파신호의 특징 파라메터 및 증거축적 방법을 이용한 콘크리트 강도 분류 (Pattern Classification of the Strength of Concrete by Feature Parameters and Evidence Accumulation of Ultrasonic Signal)

  • 김세동;신동환;이영석;김성환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권10호
    • /
    • pp.1335-1343
    • /
    • 1999
  • This paper presents concrete pattern recognition method to identify the strength of concrete by evidence accumulation with multiple parameters based on artificial intelligence techniques. At first, zero-crossing(ZCR), mean frequency(MEANF), median frequency(MEDF) and autoregressive model coefficient(ARC) are extracted as feature parameters from ultrasonic signal of concrete. Pattern recognition is carried out through the evidence accumulation procedure using distance measured with reference parameters. A fuzzy mapping function is designed to transform the distances for the application of the evidence accumulation method. Results are presented to support the feasibility of the suggested approach for concrete pattern recognition.

  • PDF

상관값 누적 기반 DS-UWB 레이더 시스템 (A DS-UWB Radar System Based on Correlation Accumulation)

  • 이영포;윤석호;이성로
    • 한국통신학회논문지
    • /
    • 제38C권4호
    • /
    • pp.359-364
    • /
    • 2013
  • 본 논문에서는 선박 접안 유도 시스템 등 정밀한 거리 추정을 요하는 안전항해운항, 선박트래픽관리 등의 분야에 알맞은 상관값 누적 기반 직접 수열 초광대역 (direct sequence ultra wideband: DS-UWB) 레이더 시스템을 제안한다. 제안하는 DS-UWB 레이더 시스템은 상관기 출력들을 누적하여 잡음을 평균냄으로써 잡음 성분의 영향을 줄이며, 기존의 DS-UWB 레이더 시스템들에 비해 더 빠른 시간에 신뢰성 있는 거리 추정을 수행한다. 모의실험 결과를 통해 제안하는 DS-UWB 레이더 시스템이 기존의 DS-UWB 레이더 시스템들에 비해 평균 상관 처리 시간이 더 짧을 뿐 아니라, 더 좋은 거리 추정 성능을 보임을 확인한다.

Transmission Line Analysis of Accumulation Layer in IEGT

  • Moon, Jin-Woo;Chung, Sang-Koo
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권6호
    • /
    • pp.824-828
    • /
    • 2011
  • Transmission line analysis of the surface a cumulation layer in injection-enhanced gate transistor (IEGT) is presented for the first time, based on per-unit-length resistance and conductance of the surface layer beneath the gate of IEGT. Lateral electric field on the accumulation layer surface, as well as the electron current injected into the accumulation layer, is governed by the well-known wave equation, and decreases as an exponential function of the lateral distance from the cathode. Unit-length resistance and conductance of the layer are expressed in terms of the device parameters and the applied gate voltage. Results obtained from the experiments are consistent with the numerical simulations.

통계적 처리방법을 이용한 동해안 염해 오손물의 분포특성 (The Distribution Characteristics of Salt Contaminants with Statistical Method in East Coast)

  • 최남호;박강식;한상옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권3호
    • /
    • pp.130-135
    • /
    • 2001
  • In this paper, the distribution characteristics of salt contaminants with the distance from sea in East coast, from Sokcho to Pusan of Korea peninsula were investigated to evaluate the design standard of KEPCO. To get the equivalent salt deposit density(ESDD), conventional brush wiping method was used. As the measuring period is comparatively short, and the measuring interval is long to check the maximum value, acquired ESDD data is very lower than the recommended value in the standard. The measured data didn't follow normal distribution, so it should take the statistical treatment. Through normalizing method, we could get a reliable probability data. In the past investigation, the accumulation characteristics of Japan is consulted to set the criterion, but the climatic condition of Korea is different to Japan. With the comparison of precipitation data and some measured data for long tern accumulation, we could set appropriate accumulation factor.

  • PDF

The effect of micro parameters of PFC software on the model calibration

  • Ajamzadeh, M.R.;Sarfarazi, Vahab;Haeri, Hadi;Dehghani, H.
    • Smart Structures and Systems
    • /
    • 제22권6호
    • /
    • pp.643-662
    • /
    • 2018
  • One of the methods for investigation of mechanical behavior of materials is numerical simulation. For simulation, its need to model behavior is close to real condition. PFC is one of the rock mechanics software that needs calibration for models simulation. The calibration was performed based on simulation of unconfined compression test and Brazilian test. Indeed the micro parameter of models change so that the UCS and Brazilian test results in numerical simulation be close to experimental one. In this paper, the effect of four micro parameters has been investigated on the uniaxial compression test and Brazilian test. These micro parameters are friction angle, Accumulation factor, expansion coefficient and disc distance. The results show that these micro parameters affect the failure pattern in UCS and Brazilian test. Also compressive strength and tensile strength are controlled by failure pattern.

Pipeline Design for Efficient Visual Effects Production

  • Hwang, Min Sik;Lee, Hyunseok
    • Journal of Multimedia Information System
    • /
    • 제9권3호
    • /
    • pp.219-226
    • /
    • 2022
  • The advancement of realistic visual effects technology provides increasingly immersive experiences and consumer satisfaction with content. The explosion and destruction effects in live-action films and animations are some of the most frequently used visual effects, but they are relatively difficult to execute, so it is challenging to make them look realistic. This study tested a method of effectively realizing computer-generated explosions and destruction. Experiments for this study are as follows: first, the interlink according to density accumulation of the fluid; second, the interlink according to the temperature accumulation of the fluid; and third, the interlink according to the distance between the fluid and the involved objects. This study was conducted to identify an optimal solution for producing computer-generated explosions and destruction.

이차원 물체 정합을 위한 Robust Oriented Hausdorff Measure (Robust Oriented Hausdorff Measure for 2-D Object Matching)

  • 심동규;박래홍
    • 전자공학회논문지S
    • /
    • 제36S권11호
    • /
    • pp.60-67
    • /
    • 1999
  • 본 논문은 2-D 물체 정합을 위한 robust oriented Hausdorff measure (ROHM)을 제안하였다. 이 ROHM은 기존의 Hausdorff distance (HD) 알고리듬의 거리 개념을 Hough 변환의 누적기법으로 대치함으로써 제안되었다. 제안한 알고리듬은 distance transform (DT)을 사용하는 변형된 Hough transform으로 생각할 수 있다. 또한 각 화소의 방향각을 사용하여 부적절한 대응관계를 제거하였다. 여러가지 실험영상을 이용한 실험을 통하여 제안한 알고리듬이 기존의 알고리듬들에 비하여 효율적임을 보였다.

  • PDF