• Title/Summary/Keyword: accumulated charge

Search Result 123, Processing Time 0.024 seconds

Analysis of Electrical Degradation in Epoxy Composites by Dielectric Breakdown Properties (절연파괴 특성을 이용한 Epoxy 복합체의 전기적 열화 분석)

  • 최철호;박용필;임중관
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.414-419
    • /
    • 2002
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were simulated by Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of (idled specimens with treating silane, the breakdown strength become much higher Finally, from the analysis of weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1[%], the applied field value needed to be under 21.5 MV/cm.

  • PDF

Evaluation of Insulating Reliability in Epoxy Composites

  • Park, No-Bong;Yang, Dong-Bok;Lim, Jung-Kwan;Park, Yong-Pil;Lee, Hee-Kab;Kim, Gui-Yeul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1200-1203
    • /
    • 2003
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were applied to Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased, the stronger breakdown strength became at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of filled specimens with treating silane, the breakdown strength become much higher. Finally, according to Weibull distribution analysis, reducing breakdown probability of equipment insulation lower than 0.1% level requires the allowable field allowable field intensity values to be kept under 21.5 MV/cm.

  • PDF

Evaluation of Electrical Degradation in Epoxy Composites by Dielectric Breakdown Properties (절연파괴 특성을 이용한 Epoxy 복합체의 전기적 열화 평가)

  • Lim, Jung-Kwan;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.212-217
    • /
    • 2002
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were simulated by Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of filled specimens with treating silane, the breakdown strength become much higher Finally, from the analysis of weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1[%], the applied field value needed to be under 21.5 MV/cm.

  • PDF

A New Reset Waveform for Reducing Reset Period in AC-PDP (교류형 플라즈마 디스플레이의 리셋구간 단축을 위한 새로운 리셋 파형)

  • Kim, Gun-Su;Choi, Hoon-Young;Kim, Son-Ic;Kim, Jun-Hyoung;Jung, Hai-Young;Min, Byoung-Kuk;Lee, Seok-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1636-1639
    • /
    • 2002
  • We proposed the new reset waveform for reducing reset period. The square pulse is applied to the address electrode when the ramp pulse increases before a discharge occurs between sustain electrodes. If the discharge occurs between address electrode and X electrode, the wall charge is reversely accumulated between sustain electrodes compared with the applying voltage before the discharge occurs between sustain electrodes. So the next discharge more weakly occurs between sustain electrodes. If the more weak discharge is obtained, it can make the low background luminance and the high contrast ratio and reduce ramp up time in the ramp reset waveform.

  • PDF

Analysis of Insulating Reliability in Epoxy Composites Using Weibull Distribution Equation (와이블 분포식을 이용한 Epoxy 복합체의 절연 신뢰도 해석)

  • 임중관;박용필;이준웅
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.8
    • /
    • pp.647-651
    • /
    • 2001
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were applied to Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased, the stronger breakdown strength became at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric filed is concentrated. In the case of filled specimens with treating silane, the breakdown strength become much higher. Finally, from the analysis of weibull distribution, it was confirmed that to low allowed breakdown probability under 0,.1%, the applied field value needed to be under 21.5MV/cm.

  • PDF

Prediction of Insulation Reliability and Breakdown Life in Epoxy Composites (에폭시 복합체의 절연신뢰도 및 파괴수명 예측)

  • 신철기;박건호;왕종배;김성역;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.260-264
    • /
    • 1996
  • In this study, the dieiectric breakdown of epoxy composites used for transformers was experimented and then its data were simulated by Weibull distribution probability . As a result. first of all, speaking of dielectric breakdown properties, the more hardener increased the stronger breakdown strength at low temperature, and the breakdown strength of specimens because it is believed that the adding filler farms interface and charge is accumulated in it, therefore the molecular motility is raised, the electric field is concentrated, and the acceleration of electron and the growth of electron avalanche are early accomplished. In the case of filled specimens with treating silane, the breakdown strength become much higher since the suggests that silane coupling agent improves interfacial combination and relays electric field concentration. Finally, from the analysis 7f weibull distribution. it was confirmed that as the allowed breakdown probability was given by 0.11[%].

  • PDF

A Study on the Optimum Driving Conditions of AC-PDP using the V-Q Lissajous‘ Figure (V-Q Lissajous' Figure을 이용한 AC-PDP 최적 구동 조건에 관한 연구)

  • Cho, Woo-Sung;Choi, Chang-Hun;Kim, Young-Cho;Park, Sun-Woo;Rho, Seung-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.128-131
    • /
    • 2002
  • In this paper, we used the V-Q Lissajous‘ figure for studying on the plasma discharge characteristics of the 42 inches AC-PDP. From the V-Q Lissajous‘ figure, we could observe exactly the driving conditions that the self-erasing discharge takes place. At the time, the total wall charges lessened by self-erasing discharge was calculated quantitatively. Beside of the just observation of self-erasing discharge and calculation of the charges lessened, we could find out the optimum driving conditions for inducing the maximum wall charges accumulated on the dielectric layer with measuring the Wall voltage from the V-Q Lissajous' figure.

  • PDF

Insulating Reliability according to additives in Epoxy Composites for PCB Material (인쇄 회로 기판용 에폭시 복합체의 첨가제에 따른 절연 신뢰도)

  • Yang, Jeong-Yun;Park, Young-Chull;Park, Geon-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05b
    • /
    • pp.159-163
    • /
    • 2003
  • In this study, the DC dielectric breakdown of epoxy composites used for PCB material was experimented and then its data were simulated by Weibull distribution equation. The more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical, and the breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised, the electric field is concentrated, and the acceleration of electron and the growth of electron avalanche are early accomplished. From the analysis of Weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1[%], the applied field value needed to be under 21.5[kV/mm].

  • PDF

Development of data acquisition and analysis program modules for leakage current of polymeric insulators using the Labview software (Labview를 이용한 배전용 폴리머애자의 누설전류 측정 및 분석 프로그램 개발)

  • Cho, Seong-Soo;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1969-1971
    • /
    • 2000
  • This paper presents a data acquisition and analysis program modules that has been developed using the Labview program. These program modules can use to acquire and analyze leakage current data of insulator under different contamination conditions. The experimental hardware made up salt fog chamber, AC/DC power supply, transducer (shunt resistor), measurement devices and PC with the GPIB (General Purpose Interface Bus). And analysis program modules can calculate pulse level count, accumulated charge, average leakage current, power spectrum, and harmonics. The result of applying these analytical program modules to polymeric insulator is available for evaluation of leakage current characteristic of outdoor insulators.

  • PDF

A Study on Electrostatic Charging Characteristics in Vehicle Fuel Systems (차량 연료시스템에서의 정전기 축적특성 연구)

  • Seo, Joon-Ho;Na, Byung-Chul;Kim, Jin-Young
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2157-2162
    • /
    • 2004
  • As the friction between two mated materials generates electrostatic voltage, vehicles especially in the cold climate has been accumulated an electrostatic voltage by the reason of fuel flow in the fuel line, air flows out side of vehicle, etc. In this study, investigations of electrostatic discharge characteristics has been carried out in the fuel systems of gasoline engines depending on the environment temperature. For the experiment, conventional fuel filters(paint coated steel case) and specially made testing equipment are prepared. The experimental results shows, an accumulation speed of electrostatic voltage depends on the environmental temperature and new methods of testing procedures are required compare to SAE standards.

  • PDF