• Title/Summary/Keyword: acceptable limit

Search Result 260, Processing Time 0.023 seconds

Evaluation of Analytical Parameters on Forming Limit Diagram based on Initial Geometrical Instability (초기 형상 불안정성 기반 성형한계선도의 이론적 변수에 따른 성형 한계영역 평가)

  • Noh, H.G.;Lee, B.E.;Kim, J.;Kang, B.S.;Song, W.J.
    • Transactions of Materials Processing
    • /
    • v.23 no.4
    • /
    • pp.199-205
    • /
    • 2014
  • The current study examines the effect of the analytical parameter values on the theoretical forming limit diagram (FLD) based on the Marciniak-Kuczynski model (M-K model). Tensile tests were performed to obtain stress-strain curves and determine the anisotropic properties in the rolling, transverse and diagonal direction of SPCC sheet materials. The experimental forming limit curve for SPCC sheet material was obtained by limiting dome stretching tests. To predict the theoretical FLD based on the M-K model, the Hosford 79 yield function was employed. The effects of three analytical parameters - the exponent of the yield function, the initial imperfection parameter and the fracture criterion parameter - on the M-K model, were examined and the results of the theoretical FLD were compared to the experimentally measured FLD. It was found that the various analytical parameters should be carefully considered to reasonably predict the theoretical FLD. The comparison of the acceptable forming limit area between the theoretical and experimental FLD is used to compare the two diagrams.

A study on Korean drivers' acceptance and traffic sign conditions assessment for Speed Assistance Systems (속도제한 지원장치에 대한 운전자 인식도 및 도로환경 분석)

  • Lee, Hwa Soo;Cho, Jae Ho;Yim, Jong Hyun;Lee, Hong Guk;Chang, Kyung Jin;Yoo, Song Min
    • Journal of Auto-vehicle Safety Association
    • /
    • v.7 no.3
    • /
    • pp.30-34
    • /
    • 2015
  • This study examined the Korean drivers' acceptance of SAS(Speed Assistance systems) and traffic sign conditions in Korea roads for SLIF(Speed Limit Information Function) that is a part of SAS. Exceeding the speed limit is a factor in the severity of many road accidents and SAS would help the driver to observe a speed limit by warning and/or effectively limiting the speed of the vehicle. SAS are in the initial phase in Korea, Korean drivers could not be familiar with automatical speed limiting during driving, SAS interface design would be considered to be more readily acceptable to the public. And advanced SAS have been introduced onto the market which are able to inform the driver of the current speed limit based on camera and/or digital maps based SLIF. These systems are based on external data using sensors, so environmental conditions are an important factor which could cause malfunction of SLIF functions.

Pilot Age Older than 65, A New Challege (조종사 정년연장에 대한 고찰: 65세 이후)

  • Hyun, WooSeok;Ahn, KyungSoo;Lee, Gun Young;Min, Seong Sik;Jang, JoungSoon
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.27 no.4
    • /
    • pp.105-113
    • /
    • 2019
  • The commercial pilot retirement age has continued to 65 since the International Civil Aviation Organization(ICAO) amended the recommended age limit from 60. The target of this review is to analyse whether aged pilots have an increased age-dependent risk of medical incapacitation. Medical in-flight incapacitation is actually very rare event and the demonstrated annual incapacitation rate provides an acceptable risk within the criteria known as 1% safety rule for a pilot undertaking air transport operations while some controversies exist. There is a possibility that the accident rate has decreased due to the improved skill by increasing pilot's age. At the decision of flight or not for elderly airline pilot the interacting factors of personal health status, piloting experience and new flight environments should be considered to define job limit criteria than mere the age. Results of a survey led by airline pilot association in Korea shows 65% of airline pilots are willing to fly without any age limit and 87% agreed that age limit is worthy to extend beyond current standard on the basis of medical examinations. Only 11% agreed to maintain current age limit.

Field Survey on Suitable In-service Wind Speed Limit for Tower Crane Operation (타워크레인의 작업 중지 풍속에 대한 현장 실태 조사 연구)

  • Lee, Eui Ju;Shin, Sung Woo
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.103-108
    • /
    • 2018
  • Since tower cranes are susceptible to wind loads, the operation of the tower crane should be ceased when it exposed to a strong wind. For this reason, even in Korea, the operation limit for wind loading on the tower crane is regulated by a law. Recently the Korean law in which provided the wind speed limit to cease the tower crane operation has been revised from "instantaneous wind speed of 20 m/s" to "instantaneous wind speed of 15 m/s". Although this revision is expected to reduce safety risks in tower crane operation, some field operators still insist to lower the wind speed limit. However, in many countries "wind speed of 20 m/s" is normally used as the maximum in-service wind speed for tower cranes. Therefore, the investigation of the proper wind speed for regulation would be helpful to secure the safety of the tower crane operation under windy condition. In this study the validity of the revised wind speed limit is investigated with the surveys targeted to both tower crane practitioners and parties of concerned in construction companies, in which various questions was provided for a suitable wind speed limit and the answers were analyzed. The results showed that the revised wind speed limit is acceptable to tower crane practitioners as well as the parties of concerned in construction companies and is satisfying the structural stability requirement for in-service state tower crane. Therefore, it can be concluded that the revised wind speed limit is valid in humanly safety point of view.

Comparison of monotonic and cyclic pushover analyses for the near-collapse point on a mid-rise reinforced concrete framed building

  • GUNES, Necmettin
    • Earthquakes and Structures
    • /
    • v.19 no.3
    • /
    • pp.189-196
    • /
    • 2020
  • The near-collapse performance limit is defined as the deformation at the 20% drop of maximum base shear in the decreasing region of the pushover curve for ductile framed buildings. Although monotonic pushover analysis is preferred due to the simple application procedure, this analysis gives rise to overestimated results by neglecting the cumulative damage effects. In the present study, the acceptabilities of monotonic and cyclic pushover analysis results for the near-collapse performance limit state are determined by comparing with Incremental Dynamic Analysis (IDA) results for a 5-story Reinforced Concrete framed building. IDA is performed to obtain the collapse point, and the near-collapse drift ratios for monotonic and cyclic pushover analysis methods are obtained separately. These two alternative drift ratios are compared with the collapse drift ratio. The correlations of the maximum tensile and compression strain at the base columns and beam plastic rotations with interstory drift ratios are acquired using the nonlinear time history analysis results by the simple linear regression analyses. It is seen that these parameters are highly correlated with the interstory drift ratios, and the results reveal that the near-collapse point acquired by monotonic pushover analysis causes unacceptably high tensile and compression strains at the base columns, as well as large plastic rotations at the beams. However, it is shown that the results of cyclic pushover analysis are acceptable for the near-collapse performance limit state.

Active vibration control of smart composite structures in hygrothermal environment

  • Mahato, P.K.;Maiti, D.K.
    • Structural Engineering and Mechanics
    • /
    • v.44 no.2
    • /
    • pp.127-138
    • /
    • 2012
  • The composite materials may be exposed to environmental (thermal or hygral or both) condition during their service life. The effect of environmental condition is usually adverse from the point of view of design of composite structures. In the present research study the effect of hygrothermal condition on the design of laminated composite structures is investigated. The active fiber composite (AFC) which may be utilized as actuator or sensor is considered in the present analysis. The sensor layer is used to sense the level of response of the composite structures. The sensed voltage is fed back to the actuator through the controller. In this study both displacement and velocity feedback controllers are employed to reduce the response of the composite laminate within acceptable limit. The Newmark direct time integration scheme is employed along with modal superposition method to improve the computational efficiency. It is observed from the numerical study that the laminated composite structures become weak in the presence of hygrothermal load. The response of the structure can be brought to the acceptable level once the AFC layer is activated through the feedback loop.

Development Acceptable Risk Model for International Construction Projects - Focusing on Small and Medium Construction Companies - (해외 건설 다수 프로젝트 관리를 위한 허용리스크 도출 - 중소·중견 건설기업 관점에서 -)

  • Hwang, Geunouk;Park, Chan Young;Jang, Woosiki;Han, Seung Heon;Kang, Sin Young
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.3
    • /
    • pp.90-97
    • /
    • 2016
  • Since Korean construction firms have steadily advanced into the international market, small and medium construction companies (SMCCs) have also advanced in such market. SMCCs's recent trend have clearly shown the changes of contract types from single subcontractor projects to multiple general contracting projects. However, among those multiple projects performed by SMCCs, 1 out of 3 projects were deficit projects that impact the overall pe rformance of the firm. To increase such performance, risk management for in international construction must be managed at the enterprise level for SMCCs. This research aims to create a multiple project management model for SMCCS that employs the concept of acceptable risk to assess the limit risk level for corporation to acceptable. Using the accumulated data from previous survey and International Construction Association of Korea (ICAK), integrated risk of each firm and their profitability of each project are analyzed. Through the analysis, each firm's acceptable risk level is derived. Through the two research steps, acceptable risk algorithm was developed based on corporate integrated risk and profit correlation. To prove the acceptable algorithm relevance, financial statement analysis of 3 corporation was derived that level of acceptable risk and financial statement were available. Through the approach, this research allows the firms to analyze the firm's capability and find projects that suits the firm's situation and capability.

An Experimental Study on Bond Property of Reinforced High Strength Concrete Beam (고강도 철근콘크리트 보의 부착특성에 관한 실험적 연구)

  • 조상섭;김상우;이시학;김용부
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.605-608
    • /
    • 1999
  • The objective of this research is to examine whether the determination of development length for high strength concrete by the ACI Building Code 318-95 could be applied and the upped limit of compressive strength, 700kg/$\textrm{cm}^2$ is suitable. Eight beam specimens were tested. Each beam was designed to include two bars in tension, spliced at the center of the span. The beams were loaded in positive bending with the splice in a constant moment region. The variables used here were compressive strength and the space of stirrup within splice length. The results indicated that for (c$\div$Ktr)/db of the range of 1.5-2.0 compressive strength up to 800kg/$\textrm{cm}^2$ is acceptable with regard to bond strength and ductility, thus the limit of compressive strength in ACI 318-95 may be extended to 800kg/$\textrm{cm}^2$.

  • PDF

A New Method far Singularity Avoidance of 6 DOF Articulated Robot Manipulators using Speed Limiting algorithm (최대속도제한 알고리즘을 이용한 6축 수직다관절 로봇의 새로운 특이점 회피방법 개발)

  • 최은재;정원지;홍대선;서영교;홍형표
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.454-457
    • /
    • 2002
  • This paper presents a new motion control for singularity avoidance in 6 DOF articulated robot manipulators, based on a speed limiting algorithm for joint positions and velocities. For a given task, the robot is controlled so that the joints move with acceptable velocities and positions within the reachable range of each joint by considering the velocity limit. The proposed method was verified using MATLAB-based simulations.

  • PDF

Funnel Design Guidance (Funnel 설계 권고안)

  • Jeong, Wang-Jo;Cho, Won-Ho;Kang, Dae-Youl;Kim, Seung-Hyuk
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2006.09a
    • /
    • pp.59-64
    • /
    • 2006
  • Most important factor to consider funnel performance is exhaust gas temperature and exhaust gas concentration Electric equipments on the wheelhouse top affected exhaust gas temperature. So, it is important that electric equipments keep away from high temperature. Though exhaust gas concentration is not a regulation and restraint, the exhaust 9as can cause serious problems for the on-board air quality and result in irreversible damage to the ship and people. So, we pocus on the exhaust gas concentration also. When judge whether a measured concentration is acceptable or not, criteria based on the LTEL (Long Term Exposure Limit). In this paper, we carried out the smoke simulation study. For this analysis, we used FLUENT which is commercial CFD (Computational Fluid Dynamics) code.

  • PDF