Identification of the Failure of VFD Heat Sink at Fossil Power Plant

  • Jung, Jine-sung;Lee, Han-sang;Kim, Min-tae;Kim, Eui-hyun
    • Corrosion Science and Technology
    • /
    • 제8권4호
    • /
    • pp.153-156
    • /
    • 2009
  • The water cooling system for VFD (Variable Frequency Drive) of a fossil fuel power plant was reported to be shut down due to a water leak at the metal connection of the heat-sink to the hoses. In order to identify the cause of the failure, the system was visually inspected, and corrosion products were analyzed with SEM equipped with EDX. The failure was observed repeatedly at the nipples of certain location, suggesting galvanic corrosion. In a U-shaped heat sink with two nipples, for inlet and outlet, only one nipple was corrosively damaged at the tip, while the other was not. Most of the corrosion products were observed at the sound nipple and in the filter, identified as $Cu(OH)_2$. Some other corrosion products, composed of mostly $Cu_2O$, were found at the corrosively attacked nipple. A fair amount of Cl was also detected on the surface of the damaged nipple. It was concluded that galvanic corrosion was occurred due to a current leakage over the whole system, and the damage was accelerated by the accumulated chlorine ions in the cooling water.

배전용 변압기에서의 고온열화와 열 사이클 열화에 따른 식물유와 광유의 특성 분석 (Analysis of Accelerated Aging Natural Ester Oil and Mineral Oil in Distributional Transformers)

  • 안정식;최순호;방정주;정중일;허창수
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1163-1168
    • /
    • 2011
  • Most transformers use insulating and cooling fluids derived from petroleum crude oil, but mineral oil has some possibility of environmental pollution and fire with explosion. vegetable oil fluids extracted from seed has superior biodegradation and fire-resistant properties including an exceptionally high fire point enhancing fire safety. In this study, it is aimed at the practicality of substituting natural ester dielectric fluid for mineral oil in liquid insulation system of transformers. As a rise in coil winding temperature has a direct influence on transformer life time, it is important to evaluate the temperature rise of coil winding in vegetable oil in comparison with mineral oil. Four transformers for the test are designed with 10KVA, 13.2KV, one phase unit. The temperature are directly measured in insulating oil of these transformers with the two sorts of natural ester and mineral oil dielectric fluid respectively. Experiment for aging carry out two means. First means remained $120^{\circ}C$ that transformer of mineral oil were operated at 185% load. Second means is that insulating oils of two natural ester and mineral oil were aged by thermal cycles repeating from $30^{\circ}C$ to $120^{\circ}C$. For the heating, Transformers were operated at 185% load. For the cooling, cooling system was operated in the chamber. Samples were analyzed at 42, 63, 93, 143, 190, 240 300cycles. Analysis contents are dielectric strength, total acid value. Mineral oils compared results of first means with results of second means. And compared two sort natural esters respectively with mineral oil in second means.

Synthesis and Non-Isothermal Crystallization Behavior of Poly (ethylene-co-1,4-butylene terephthalate)s

  • Jinshu Yu;Deri Zhou;Weimin Chai;Lee, Byeongdu;Le, Seung-Woo;Jinhwan Yoon;Moonhor Ree
    • Macromolecular Research
    • /
    • 제11권1호
    • /
    • pp.25-35
    • /
    • 2003
  • A series of random poly(ethylene-co-1,4-butylene terephthalate)s (PEBTs), as well as poly(ethylene terephthalate) (PET) and poly(1,4-butylene terephthalate) (PBT), were synthesized by the bulk polycondensation. Their composition, molecular weight, and thermal properties were determined. All the copolymers are crystallizable, regardless of the compositions, which may originate from both even-atomic-numbered ethylene terephthalate and butylenes terephthalate units that undergo inherently crystallization. Non-isothermal crystallization exotherms were measured over the cooling rate of 2.5-20.0 K/min by calorimetry and then analyzed reasonably by the modified Avrami method rather than the Ozawa method. The results suggest that the primary crystallizations in the copolymers and the homopolymers follow a heterogeneous nucleation and spherulitic growth mechanism. However, when the cooling rate increases and the content of comonomer unit (ethylene glycol or 1,4-butylene glycol) increases, the crystallization behavior still becomes deviated slightly from the prediction of the modified Avrami analysis, which is due to the involvement of secondary crystallization and the formation of relatively low crystallinity. Overall, the crystallization rate is accelerated by increasing cooling rate but still depended on the composition. In addition, the activation energy in the non-isothermal crystallization was estimated.

고반사 도료를 사용한 차열성 아스팔트 도로포장의 온도저감특성 (Properties of Temperature Reduction of Cooling Asphalt Pavements Using High-Reflectivity Paints)

  • 홍창우
    • 대한토목학회논문집
    • /
    • 제33권1호
    • /
    • pp.317-327
    • /
    • 2013
  • 도심지의 대기오염 및 인공열 등으로 인해 도시열섬현상이 발생되고 있으며, 특히 아스팔트 포장의 경우 낮에는 일사열을 흡수하고 밤에 방출하기 때문에 도심부의 환경을 개선하기 위해서는 도심 도로포장의 온도를 저하시키는 차열성 포장에 대한 연구의 필요성이 제기되고 있다. 도로포장에 차열성 도료를 적용하기 위해서는 시인성을 높이기 위해 흑색명도를 저하시켜야 하며, 적외선 반사율은 증가시키고, 가시광선 반사율은 최소화 하는 특성이 요구된다. 본 연구에서는 1액형 아크릴 에멀젼을 주 바인더로 사용하고 안료의 종류(카본블랙, 합성무기안료) 및 중공세라믹 혼입률(0%, 15%, 30%)변화, 흑색명도의 변화를 주요 실험인자로 선정하였다. 차열성 도로포장의 온도저감 성능은 분광반사율과 일사반사율, 램프 조사 방법을 통해 분석하였다. 그리고 마모저항성, 자외선 촉진내후성, 미끄럼 저항성에대한 현장적용성을 평가하였다. 그리고 고반사 도료 시험포장에 대해서 열화상 촬영을 통해 온도저감 효과를 분석하였다. 실험결과 합성무기안료와 중공세라믹 30%를 혼입한 경우에 흑색 명도 $L^*$= 42.89에서 분광반사율이 근적외선 영역에서 43%, 가시광선 영역에서 17%를 보였으며, 일사반사율은 27.5%로 나타났다. 그리고 자외선 촉진내후성 시험에 의한 총색차 ${\Delta}E$가 0.27로 색변화가 거의 발생되지 않았으며, 규사 2호, 4호를 상도, 하도에 $0.12kg/m^2$이상 산포할 경우 BPN은 53이상을 보였다. 또한 테이버 마모시험에 의한 마모감량은 500회전시 최대 86.4mg이하로 나타났다. 아스팔트 포장에 고반사 도료를 시공한 시험구간의 열저감 성능을 열화상 촬영에 의해 평가한 결과 CI-30-40 차열성포장($L^*$=38.76)은 $12.7^{\circ}C$, CI-30-60 차열성포장($L^*$=57.12)은 $14.2^{\circ}C$의 온도저감효과를 보였다.

초고탄소강의 제어압연에 의한 세멘타이트의 구상화와 냉각중 마르텐사이트의 핵발생과 성장의 현상론적 고찰 (Study on the Spheroidization of Cementite by Controlled-Rolling and Martensitic Nucleation and its Growth during Cooling in Ultra High Carbon Steel)

  • 최종술;윤진국
    • 열처리공학회지
    • /
    • 제6권2호
    • /
    • pp.98-106
    • /
    • 1993
  • Ultra high carbon steel (Fe-1.4%C) was prepared by means of a high frequency induction furnace. The preferred nucleation site of martensite was observed. The changes of hardness and impact thoughness due to tempering temperatures, and the spheroidization of cementite by controlled -rolling were also studied for the steel. The preferred nucleation site of martensite in the ultra high carbon steel is prior austenite grain boundary. The hardness of the steel is slightly increased up to about $300^{\circ}C$, and then decreased with further tempering temperature. However, the impact energy keeps a almost constant value, independent of the tempering temperature. The spheroidization of cementite is accelerated as the reduction in thickness per rolling pass is increased and the number of the rolling passes becomes greater.

  • PDF

롤러 레벨링 공정시 후판의 잔류응력 예측 - Part II : 가속냉각 모델을 통합한 모델 (Prediction of the Residual Stress for a Steel Plate after Roller Leveling - Part II : Integrated Model with Accelerated Cooling Model)

  • 예호성;황상무
    • 소성∙가공
    • /
    • 제22권1호
    • /
    • pp.11-16
    • /
    • 2013
  • Despite its importance the control of roller leveling has primarily relied on the operator's experience and on operation tables. In order to effectively eliminate various shape defects, the optimal leveling condition for a specific mode of plate deformation needs to be determined as well as a careful evaluation as to whether or not the condition is still appropriate for other modes or not. A numerical model, which considers both computation efficiency and accuracy, has been developed. The variations of residual stress are studied according to the entry and the delivery intermeshes, respectively. The camber deformation decreases linearly as the entry intermesh increases. In contrast the curl deformation does not vary directly with the entry intermesh. Therefore, the optimum intermesh values need to be determined in order to simultaneously minimize both the camber and the curl deformation.

Al합금 열교환기의 전지작용부식에 관한 연구 (The Study on the Galvanic Corrosion of Al-alloy for Heat Exchanger)

  • 임우조;이은정
    • 수산해양교육연구
    • /
    • 제15권1호
    • /
    • pp.115-122
    • /
    • 2003
  • Generally, material for radiator of automobile is composed of Al-alloy, but part of radiator material is still composed of Cu. Specially, Al-alloy replaces Cu and Cu-alloy as cooling and heating system material for light weight. Therefore, galvanic electronic cell is formed between Al-alloy and Cu for automobile radiator material, and Al-alloy corrosion is accelerated. So, in this study, galvanic corrosion test of Al-alloy coupling with Cu was carried out in distilled water, tap water, polluted environment and non-freezing solution. And thus corrosion potential and galvanic currrent density of Al-alloy coupling with Cu is investigated.

An Accelerated Simulated Annealing Method for B-spline Curve Fitting to Strip-shaped Scattered Points

  • Javidrad, Farhad
    • International Journal of CAD/CAM
    • /
    • 제12권1호
    • /
    • pp.9-19
    • /
    • 2012
  • Generation of optimum planar B-spline curve in terms of minimum deviation and required fairness to approximate a target shape defined by a strip-shaped unorganized 2D point cloud is studied. It is proposed to use the location of control points as variables within the geometric optimization framework of point distance minimization. An adaptive simulated annealing heuristic optimization algorithm is developed to iteratively update an initial approximate curve towards the target shape. The new implementation comprises an adaptive cooling procedure in which the temperature change is adaptively dependent on the objective function evolution. It is shown that the proposed method results in an improved convergence speed when compared to the standard simulated annealing method. A couple of examples are included to show the applicability of the proposed method in the surface model reconstruction directly from point cloud data.

주복수기 냉각해수배관의 직각 엘보 내부유동특성에 관한 연구 (Experimental study of internal flow field about 90degree elbow for cooling seawater pipe at the main condenser)

  • 오승진;조대환;봉태근;김옥석
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2012년도 전기공동학술대회 논문집
    • /
    • pp.152-153
    • /
    • 2012
  • While engine room arranging pipe which is used from the vessel, It measured the internal flow of 90 degree elbow which is used from the main condenser. Fluid flow in elbow of 90 degree is measured by PIV and Dewetron system. The Reynolds number adopts 50000 and experimental study of flow field in the elbow.

  • PDF

다양한 온도 환경에서의 RC-LFS 기반 수경성 복합 재료의 수화발열 특성 (Hydration Heat Property of RC-LFS based Hydraulic Composite according to Various Ambient Temperature)

  • 이무;김진만;최선미
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.24-25
    • /
    • 2017
  • Ambient temperature has a direct impact on the hydraulic process. Though -any experiments have been processed in order to investigate the hydration properties under the various ambient temperature of OPC, there are not reported about aluminate-based composite. This presentation is composed of contents on the experimental investigation of the hydration heat of pulverized rapid cooling ladle furnace slag based composite. Based on the experimental outcomes, gypsum can decrease the hydration heat dramatically and lower ambient temperature has a negative effect on accelerated the hydraulic process.

  • PDF