• 제목/요약/키워드: absorption type

검색결과 1,415건 처리시간 0.026초

고효율 흡수식 냉동기의 특허기술 분석연구 (An Analysis of the Patent for Highly Efficient Absorption Refrigeration System)

  • 심윤희;박윤철;배영문
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.332-339
    • /
    • 2004
  • A technical analysis was conducted to predict the development trend for the highly efficient absorption type refrigeration system. The study was based on a submitted patent during January 1981 and December 2000 in Korea, Japan and America. The total number of extruded patents from the registered database was 24,822 and the filtering process makes the reduction of the data number to 3,510. Technical development of Japan for the absorption type refrigeration system is prominent compared to the other country due to approximately 75% of the patents coming from Japan. When the patent is divided into two categories, the patent for component technology for the refrigeration system makes up 75% and the refrigerating type technology 25% of the patents. This shows technical development for the system component is advanced compared to the technology development for the system type. When the patents are classified by nationality of patent applicants, foreigners contribute up to 33% of the patents in Korea. However, Japan's case shows the 99% of the patents are invented by the Japanese. If the patents are classified to the International Patent Classification, most of the data for the absorption type refrigeration system belongs to IPC F25B.

유기 다공성 소재의 흡유 효과 (Oil Absorption Effects of Organic Porous Materials)

  • 강영구;한상범
    • 한국안전학회지
    • /
    • 제21권1호
    • /
    • pp.86-91
    • /
    • 2006
  • Oil spills caused by the accidents have been occurred from house and factory waste, grounded tanker, the rupture of storage tank and oil pipelines, the deterioration of various industrial facilities, etc. Many oil spills result in contamination of shorelines and workplace. Fire and explosion may happen from these spills. There are several technologies used for clean-up application, which include use of oil dispersing agents, absorbents, solidifiers, booms and skimmers by physical, chemical, and biological methods. Methods for oil spill clean-up operation are classified into the absorption type, gel type and self-swelling type. Porous materials with oil absorptive properties are classified into micropore, mesopore, and macropore depending on their pore sizes. Recently, new porous materials with smaller size have been developed, but the selective oil absorption in water-in-oil interface demonstrates the macro pore size. In this study oil absorption effects were evaluated using the organic porous materials with a complex function of gel type and swelling type. Samples were subjected to analysis by FT-IR spectroscopy and were characterized in terms of gel formation and morphologies. Oil sorption capacity, pressure retention force and gel strength were also measured. From these results, the physicochemical reactivity before and after gelation was verified and the industrial applications of clean-up operation were suggested.

공랭형 병렬방식 2중효용 흡수식 냉방시스템의 사이클 해석 (Cycle Analysis of Air-Cooled Double-Effect Absorption Cooling System with Parallel Flow Type)

  • 오명도;김선창;김영인;이홍원
    • 대한기계학회논문집
    • /
    • 제17권8호
    • /
    • pp.2099-2109
    • /
    • 1993
  • A gas-fired 4RT absorption heat pump was designed as an air-conditioner for domestic use during the summer. The absorption heat pump is air-cooled. double-effect, $LiBr-H_{2}O$ system with parallel flow type. The performance of the absorption heat pump in the cooling mode of operation was investigated through cycle modeling and simulation to obtain the system characteristics with parameter changes. System parameters considered in this analysis were the inlet temperature of cooling air to the absorber, the working solution concentrations, the ratio of the amount of the weak solution from the absorber, and the LTD's of each heat exchange component. The optimum designs and operating conditions were determined based on the operating constraints and the coefficient of performance.

플레이트-휜형 흡수기의 흡수성능에 대한 연구 (The Study on Absorption Performance of a Plate-Fin Type Absorber)

  • 강인석;김남진;김종보
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.557-563
    • /
    • 2001
  • Small capacity gas absorption systems for cooling and heating have been favorably considered to reduce the seasonal imbalance of electrical loads and LNG consumption recently. A multifunctional plate-fin heat exchanger was adopted as an absorber and the performance was tested and analyzed to reduce the size and weight of the absorption heat pump. The test was performed using breadboard type ammonia absorption machine. The performance was compared with the plate type absorber and there was little difference in heat and mass transfer characteristics. The heat and mass transfer performance was a function of poor solution and vapor flow rates and the mass transfer was dependent on vapor flow rate more than heat transfer.

  • PDF

직렬 갭 피뢰기의 흡습시 전극표면의 변화 및 특성 (Characteristics and Change of Electrode Surface in Moisture Absorption on the Series Gap Surge Arrester)

  • 조한구;김향숙
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1172-1175
    • /
    • 2003
  • The characteristics and change of electrode surface about Gap type surge arrester for protect DC subway rail were investigated with moisture absorption. Compared that tested about DC/AC discharge commencement voltage, residual voltage, Impulse, square wave impulse for DC rail surge arrester about Gap type surge arrester of moisture absorption state. The AC discharge commencement voltage acted greatly effect of moisture absorption than the DC discharge commencement voltage test.

  • PDF

Organic Solvent Absorption characteristics of Split-type micro fiber fabrics

  • Lee, Kwang-Ju;Kim, Seong-Hun
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 2003년도 The Korea-Japan Joint Symposium
    • /
    • pp.95-95
    • /
    • 2003
  • In this study, the influences of organic solvent viscosity on absorption properties of split-type micro fiber fabrics is examined with real time absorption measurement device built by our research group recently. And the absorption behavior of these fabrics is analyzed by material, fineness, construction, weight, thickness, and density of fabrics.

  • PDF

하수처리수이용 흡수식냉동사이클의 해석 (Analysis of Absorption Refrigeration Cycles to Utilize Treated Sewage)

  • 이용화
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.288-298
    • /
    • 1996
  • The gas-fired absorption refrigeration system to utilize treated sewage is available for environmental protection and energy conservation. Simulation analysis on the double-effect absorption refrigeration cycles with parallel or series flow type has been performed. The working fluid is Lithium Bromide and water solution. The main purpose of this study is evaluating the possibilities of effective utilization of treated sewage as a cooling water for the absorber and condenser. The efficiency of a couple of cycles has been studied and simulation results show that higher coefficient of performance could be obtained for parallel flow type. The other purpose of the present study is to determine the optimum designs and operating conditions based on the operating constraints and the coefficent of performance in the paralledl flow type.

  • PDF

삼중효용 흡수사이클의 성능특성 평가 (evaluation of Performance Characteristic on Triple Effect Absorption Cycle)

  • 권오경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.782-791
    • /
    • 1998
  • This paper presents a computer simulation of five types of triple effect absorption cycles employ-ing the refrigerant absorbent combinations of NH3/LiNO3 low-pressure type NH3/LiNO3+H2O/LiBr binary two-stage type series flow cycle and two types of parallel flow cycle for H2O/LiBr. The absorption systems is investigated through cycle simulation to obtain the system characteristics with the cooling water inlet temperature approach temperature of absorber loss temperature of absorber and chilled water outlet temperature. The most important characteristic temperature of absorber and chilled water outlet temperature. The most important characteristic of NH3/LiNO3 low-pressure type and a NH3/LINO3+H2O/LiBr binary two-stage type is that it obtains a coefficient of performance higher than the sum of the performance coefficients of its part operating independently. As a result of this analysis the optimum designs and operating conditions were determined based on the operating conditions and the coefficient of performance.

  • PDF

박막 공명형 시스템의 흡음성능에 관한 실험적 연구 (An Experimental Study on the Sound Absorption of a Membrane Resonance Type System)

  • 양수영;제현수;홍병국;송화영;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.1036-1039
    • /
    • 2004
  • This paper is to experimentally study on the sound absorption of a membrane resonance type system. Membrane resonance type system improves the weak point of a perforated plate system. The experimental results for a membrane resonance type system are explained in comparison with those of a perforated plate system. From the experimental results, it is found that there is an influence of the membrane on the absorption performance. The sound absorbing performances of a membrane resonance system are similar to those of a perforated plate system.

  • PDF

천연염색의 매염제 흡착 및 매염조건에 관한 연구 (The Study on Mordant Absorption and Mordanting Treatment Condition of Natural Dyeing)

  • 주영주
    • 복식
    • /
    • 제55권5호
    • /
    • pp.101-107
    • /
    • 2005
  • In this article, mordant absorption rate by the Change of temperature and fabric, discharge level by water washing, mordant density and method in mordant dye are going to be handled. Besides, how treatment method will have an effect on absorption rate and color, is also going to be covered. An atom extinction photometer was used to measure the amount of mordant absorbed in fabric at each temperature and mordant type. It turned out that absorption rate differs according to the type of mordant and sample or temperature. Also it turned out that the mordant input amount has little influence on absorption rate, that is to say, if though you use more mordants, just tiny amount of mordant is going to be absorbed in cloth. It is true that the higher temperature goes up, the better mordant absorption gets. It is found that the type of mordant and sample, treatment period affects the discharge rate. Normally $15{\~}98\%$ mordant comes off the fabric by water washing, to be specific, $17{\~}47\%$ Iron by water washing and it has better performance on cotton and nylon than silk, $1\%{\~}52\%$ Aluminum by water washing and better absorption on silk, $36{\~}89\%$ Chrome by water washing and better absorption on silk, $50{\~}89\%$ copper by water washing and better absorption on silk, poor on cotton. The examination of the K/S values and colors between before and after soaping has been conducted under the circumstance that the test fabrics had been treated at $80^{\circ}C$ for 30 minutes with $0.2\%$ soaping solution. In case of pre-mordanted fabrics, the K/S value nosedived after soaping, meanwhile densely mordanted fabric's K/S value soared but after soaping, it dropped sharply. It turned out that soaping treatment deteriorates absorption much more than water washing. It's considered that $0.1 \%$ (W/V) of mordant density is appropriate.