• Title/Summary/Keyword: absorption rates

Search Result 478, Processing Time 0.021 seconds

Dynamic Simulation of Transient Operations of a Solar Power-Assisted Absorption Chiller (태양열 보조열원을 이용한 흡수식 시스템의 동적 시뮬레이션에 의한 과도운전 특성 평가)

  • Shin, Young-Gy;Seo, Jung-A;Woo, Sung-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.2
    • /
    • pp.78-85
    • /
    • 2010
  • A dynamic model has been developed to investigate the operability of a single and double-effect solar energy assisted parallel type absorption chiller. In the study, main components and fluid transport mechanism were modeled. And solar radiation and the solar collector were also modeled along with its control design. The model was run for the single mode with solar energy supply only and the solar/gas driving double effect mode. From the simulation results, it was found that the present configuration of the chiller is not capable of regulating solution flow rates according to variable solar energy input. And the issues of the excessive circulation flow rate and the mismatch between available solar power and cooling load discourages the use of the single mode, but the dual use of gas and solar power is recommendable in view of controllability and enhanced COP.

A Study on Dynamic Simulation of a Hybrid Parallel Absorption Chiller (병렬식 하이브리드 흡수식 냉온수기 동특성 시뮬레이션 연구)

  • Shin, Young-Gy;Seo, Jung-A;Woo, Sung-Min;Kim, Hyo-Sang
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.630-635
    • /
    • 2008
  • A dynamic model has been developed to investigate the operability of a single and double-effect solar energy assisted parallel type absorption chiller. In the study, main components and fluid transport mechanism have been modeled. Flow discharge coefficients of the valves and the pumps were optimized for the double-effect mode with solar-heated water circulated. The model was run for the single mode with solar energy supply only and the solar/gas driving double effect mode. And the cases of the double mode with and without the solar energy were compared. From the simulation results, it was found that the present configuration of the chiller is not capable of regulating solution flow rates according to variable solar energy input. And the single mode utilizing the solar energy only is not practical. It is suggested to operate the system in the double mode and the flow rate control system adaptive to variable solar energy input has to be developed.

  • PDF

Biopharmaceutical studies on copper(II) chelates of sulfanilamide derivatives (Sulfanilamide유도체의 동(II)착화합물에 대한 생물약제학적 연구)

  • 김재백
    • YAKHAK HOEJI
    • /
    • v.15 no.2
    • /
    • pp.41-52
    • /
    • 1971
  • Cu(II) chelates of several sulfanilamide derivatives (Sulfa-Cu) were prepared and their effects on solubility, absorptivity in intestinal lumen, biding tendency with serum protein and erythrocytes, concentration in rabbit blood, and acetylation rate were studied in comparison with their free ligand forms. For solubility concerned, the partition coefficients of Sulfa-Cu are decreased as following order: Sulfadimethoxine Copper chelate (SDM-Cu), Sulfamethoxypyridazine Copper chelate (SD-Cu), Sulfamerazine Copper chelate (SM-Cu), Sulfaisoxazole Copper chelate (SIX-Cu). The partition coefficients of SDM-Cu and ST-Cu were much greater than those of ligands. this phenomenone acounts for the rapid absorption of SDM-Cu and ST-Cu in the rat small intestine (in situ). The Sulfa-Cu were absorbed at the intestinal lumen of a rat in the rate of first order and there was no difference between long acting sulfa drugs and their Cu0chelates in biological half lives. In binding experiments, sulfa-Cu binded with serum protein in lower ratio than their ligands except SIX-Cu. On other hand, acetylation rates of sulfa-Cu were higher than those of free sulfa drugs and the acetylation rate were higher than those of free sulfa drugs and powder. In a experiment on Sulfa-Cu concentration in rabbit blood, the half lives of SD-Cu, SIX-cu, ST-Cu, and SM-Cu were longer than those of their ligands. Above all, the half life of SD-Cu appeared to be approximately 3.5 times logner than that of corresponding ligand, SD. When absorption of sulfa drugs or sulfa-Cu at the small intestinal lumen of a rat and the concentration in rabbit blood after absorption were compared, it was found that there was not always conrrelated.

  • PDF

Dyeing of PTT Fiber(1) - Effect of Heat Setting on Dyeing and Physical Properties of PTT Fiber - (PTT 섬유의 염색성 (1) - 열처리한 PTT 섬유의 염색성 및 물성 -)

  • 이두환;정동석;이문철
    • Textile Coloration and Finishing
    • /
    • v.14 no.5
    • /
    • pp.268-276
    • /
    • 2002
  • Poly(trimethylene terephthalate)(PTT) and Poly(ethylene terephthalate)(PET) fibers were annealed at various temperatures ranging from $100^\circ{C}$ to $230^\circ{C}$ for 10 min under tension and tension free. Dyeing rates and absorption isotherms of both fibers were obtained with C.I. Disperse Red 60 at 100, 120 and $130^\circ{C}$ in water system. Also X-ray diffraction pattern, moisture regain and water absorption were investigated. The dyeing rate of PTT fiber is faster than PET fiber, and dyeing of PTT fiber begin at lower temperature compared to PET fiber. The absorption isotherms from both fibers with disperse dye we nearly linear up to the saturation dye uptake, which increase with dyeing temperature. Equilibrium dye uptake of PTT fiber annealed under tension above $180^\circ{C}$ was remarkably decreased because of a changes in the fine structure of fiber. The intensities of X-ray diffraction peaks of both annealed fibers were increased with increasing in annealed temperature. The reflections observed at $2\theta$=$15.8^\circ$, $24^\circ$ and $25.2^\circ$ were assigned reflection of crystal at the planes of (010), $(1\bar02,\;\bar112),\;and\;(\bar13,\; \bar113)$ respectively, and the peak became sharp with heat setting temperature.

Decolorization of Rhodamine B Using UV/$TiO_2$ System (UV/$TiO_2$ 시스템을 이용한 Rhodamine B의 색도 제거)

  • 박영식;나영수;안갑환
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.5
    • /
    • pp.59-64
    • /
    • 2002
  • The photocatalytic decolorization of the Rhodamine B (RhB) was studied using a UV/TiO$_2$ reactor. Yakuri titanium dioxide(anatase) was used as the suspended photocatalyst and proved to be effective for decolorization irradiated with UV light (254 mm). The photocatalyzed dioxide concentrations, light intensity and air flow rates. In 0.01 mM RhB, color could be completely photodegraded after 3 hours. Absorption spectrum of an aqueous solution containing RhB showed a continued diminution of the RhB concentration in the solution bulk : concomitantly, no new absorption peaks appeared. This confirmed the decolorization of RhB, i.e., the break up of the chromopore. The optimum loaded titanium dioxide for the decolorization was 0.75 g/(equation omitted). The light intensity showed exponential decay with distance. The decay of light intensity of RhB solution showed different tendency from TiO$_2$. These results suggested that the photocatalytic decolorization of dyes may be available method for decolorizing in wastewater.

Optical Properties of Sea Water ( IV ) - Coastal Waters of Southern Part of Korea - (해수의 광학적 성질에 관한 연구 ( IV ) - 한국남해안 -)

  • 양용림
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.14 no.1
    • /
    • pp.37-41
    • /
    • 1978
  • Optical properties were studied in the costal waters of the southern part of Korea based on twenty oceanographic stations from 1 st to 9 th February, 1977. Submarine daylight intensity was measured by using an underwater luxmeter (Toshiba No.9). Daylight intensity in the upper 30m depth layer was measured at 1 m depth interval. The absorption coefficient of the sea water in the area ranged from 0.101 to 2.539 (mean 0.578). The Secchi-disc depth in the area ranged from 0.8 to 13 meters (mean 5.33 meters). The relationship between absorption coefficient (K) and transparency (D) was k= 1. 704/ D. The mean water color in the area was 5. 75 (3-9) in Forel scales. The rates of light penetration for daylight at 1m layer in the area ranged from 13.18 to 82. 05% and the mean was 59.56%, while the rate at 5m layer ranged from 0.007 to 46.1% and the mean was 18.47%.

  • PDF

Treatment of Animal Wastewater with Absorbent Oxidation (축산폐수의 흡착산화 처리)

  • 오인환;박정현;이명규;전병태;김형화
    • Journal of Bio-Environment Control
    • /
    • v.3 no.2
    • /
    • pp.136-144
    • /
    • 1994
  • A long- time aeration method was developed for purification of animal wastewater. Under repeated aereations of 4 hours on and 4 hours off, the higher removal rates were obtained which were in average of 99%, 96%, 92% and 50% for BOD, SS, total nitrogen and phosporous, respectively. In detail, the measured BOD concentrations of the influent and effluent were 2,700ppm and 40ppm while the SS concentrations in the primary chamber and of the effluent were about 3,000 and 110 ppm, respectively. Zeolite and activated carbon, applied for removing the nitrogen and phosphorous, showed a good absorption, especially zeolite for NH$_4$-N and activated carbon for NO$_3$-N and PO$_4$-P. The treatment cost per head by this method amounts to 1,923 won and it comes to 1.6% in the whole production cost. Therefore, this method is economically available with the half cost of the conventional activated sludge process.

  • PDF

Effect of Suppository Bases on Absorption of Lithium Carbonate (좌제기제가 탄산리튬의 흡수에 미치는 영향)

  • Kim, Yong-Hyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.16 no.4
    • /
    • pp.148-151
    • /
    • 1986
  • This paper was designed to investigate the influence of different suppository bases on both the rectal absorption and dissolution rate of lithium carbonate, and to compare bioavailability from rectal administration with that from oral administration. The dissolution rates were in such order as PEG 4000, surfactant A (Witepsol 15+sodium lauryl sulfate), surfactant B (Witepsol 15+cholic acid), Witepsol 15 and cacao butter. Among various suppository bases, the blood level of lithium carbonate after rectal administration was increased in the following order: surfactant A>surfactant B>PEG 4000>Witepsol 15>cacao butter. When it comes to compare oral with rectal administration in AUC values, surfactants and PEG 4000 showed similar blood levels to oral administration, but lipophilic bases such as Witepsol 15 and cacao butter showed far lower blood level than oral administration. Peak time in oral administration was 2 hrs, but those in rectal administration using various suppository bases were $6{\sim}8$ hrs.

  • PDF

International Logistics and Standardization with Strategies (국제물류 및 표준화의 국제적 대응방안 - 물류 및 표준화 정책 중심으로 -)

  • Lee Sun-Cheol;Mun Dae-Seop;Kim Yeong-Sin
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.397-404
    • /
    • 2004
  • The higher costs of logistics in Korea than those of other developed countries have been considered as a main factor to reduce national competitiveness. In addition, the international logistics has become more important than before as trade across countries have increased with globalization. This study measured the rate of international logistics absorption as total trade volume compared total domestic consumption expenditure. The measure showed that USA($26\%$), japan($31\%$), and China($l12\%$) are important countries for Korea to cooperate for the international logistics and its standardization. However, for these countries, Korea is not important country in terms of the international logistics because the absorption rates of these countries to Korea are relatively very low as they shows $0.8\%$, $8\%$, $1.85\%$ in USA, China, and japan, respectively. Thus, we need international strategies in logistics fields to cooperate with these countries.

  • PDF

Heat and mass transfer characteristics of generator combined rectification system of the GAX ammonia absorption heat pump (GAX 암모니아 흡수식 열폄프의 발생기 일체형 정류기의 열 및 물질전달 해석)

  • 윤상국
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.431-439
    • /
    • 1999
  • A generator-GAX combined rectification system of an ammonia absorption heat pump was investigated to get the optimum design values. The mass and heat transfer phenomena of the rectification system were analysed. The number of column plates, equilibrium temperature of solution on each plate and flow rates of solution and vapor generated were predicted. The characteristics of mass and heat transfer of the generator-GAX combined rectification system, i.e. concentration difference of leaving solution and vapor on each column plate, were found to be mainly governed by the pressure of generator, reflex ratio and temperature difference of analyser coolant. The number of rectification column plates for each different pressure in generator was obtained. The optimum locations for installing the feeder from solution-cooled absorber and GAX desorber in generator were predicted. The improvement of COP was followed by the increase of the rectifier efficiency and the number of column plate, and the decrease of reflex ratio.

  • PDF