• Title/Summary/Keyword: absorption line

Search Result 402, Processing Time 0.031 seconds

Comparison of absorption based on the location of seam of cloth diaper

  • Lee, Heeran;Lee, Hyojeong;Lee, Yejin
    • Journal of Fashion Business
    • /
    • v.20 no.6
    • /
    • pp.94-110
    • /
    • 2016
  • A necessity for infants, diapers are not only used over long durations, but are also in direct contact to the infants' skin, making the choice of diaper to be of utmost importance. Current interest in cloth diapers is rapidly increasing because of issues concerning the baby's health, green environment, and economy. However, previous researches on cloth diapers are limited to simply investigating the form and material of commercial cloth diapers. There are few in-depth researches for the optimal cloth diaper development. This is therefore a fundamental research for the development of optimized cloth diapers, and analyzes the difference in absorption depending on the placement of seam line (liner, darts, and I pattern), the locations of liquid spraying (1 cm and 8 cm ahead of the center), and the amount of liquid capacity (10 and 20 ml). Currently, the development of diaper patterns considers the crotch shape of the infants and the skin length deformation. As a result, in the case of the I-pattern, the horizontal seam line prevents water from spreading to the front and back, thus reducing the absorbed area. This result was more clearly visible when water was sprayed at the center. The effect of the seam line became more obvious when there was more water (20 ml); also, when water was sprayed at the center, more leakage was observed. Using the results of this research, implementation of horizontal seam is expected to prevent the upward spread of urine.

Use of Near Infrared Spectroscopy in the Meat Industry

  • Akselsen, Thorvald M.
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2000.11a
    • /
    • pp.1-14
    • /
    • 2000
  • The Near Infrared region of the energy spectrum was first discovered by Hershel in the year 1800. The principles of NIR is based on light absorption of specific organic chemical bonds. The absorption at each wavelength is measured and a spectre is obtained. The spectre is then treated mathematically and with the absorption data is converted to absolute units via a calibration. In the last two decades it has developed dramatically. With the invention of computers and the ability to treat a large amount of data in a very short time the use of NIR for many different purposes has developed very fast. During the last decade with the aid of very powerful PC's the application of NIR technology has become even more widespread. Now or days development of very robust calibrations can be done in a relatively short time with a minimum of resources. The use of Near Infrared Spectroscopy (NIR) in the Meat industry is relatively new. The first installations were taken into operation in the 80ties. The Meat Industry in often referred to as rather conservative and slow to embrace new technologies, they stay with the old and proven methods. The first NIR instruments used by the Meat Industry, and most other industries, were multipurpose build, which means that the sample presentation was not well suited to this particular application, or many other applications for that sake. As the Meat Industry grows and develops to meet the demands of the modern markets, they realise the need for better control of processes and final products. From the early 90 ties and onward the demand for 'rear time' rapid results starts growing, and some suppliers of NIR instruments (and instruments based on other technologies, like X-ray) start to develop and manufacture instrumentation dedicated to the particular needs of the Meat Industry. Today it is estimated that there are approximately 2000 rapid instruments placed in the Meat industry world-wide. By far most of these are used as at-line or laboratory installations, but the trend and need is moving towards real on-line or in-line solutions. NIR is the most cost effective and reproducible analytical procedure available for the twenty first century.

  • PDF

Saturated absorption spectroscopy of 13C2H2 in the 1550 nm region (1550 nm 영역에서 아세틸렌 분자의 포화흡수분광)

  • 문한섭;이원규;서호성
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.2
    • /
    • pp.177-182
    • /
    • 2004
  • We have observed the saturated absorption spectrum of the P(16) line of the V$_1$+V$_3$ band of $^{13}$ C$_2$H$_2$ molecule by using the external cavity spectroscopy method. The frequency of laser has been stabilized to the saturated absorption spectrum. The relative contrast of the saturation spectrum is about 7 % with respect to the linear absorption and the linewidth is about 1.8 MHz. The frequency fluctuation of the stabilized LD is about $\pm$20 KHz during the sampling time 100 S.

Line-profile Formula in the Carbon Nanotubes by Electron Spin Resonance

  • Park, Jung-Il;Lee, Haeng-Ki
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.16 no.1
    • /
    • pp.11-21
    • /
    • 2012
  • The line-width of carbon nanotubes (CNTs) was studied as a function of the temperature at a frequency of 9.49 GHz in the presence of external electromagnetic radiation. The relative frequency dependence of the absorption power is obtained with the projection operator technique (POT) proposed by Kawabata. The line-width increased as the temperature increased in the high-temperature region (T>200 K). The scattering is little affected in the low-temperature region (T<200 K) because there is no correlation between the resonance field and the Fermi-Dirac distribution function. Thus, the present technique is considered to be more convenient to explain the resonant system as in the case of other optical transition problems.

A Preliminary Study on the In-line Concentration Measurement of Absorbent Solution (흡수용액의 In-line 농도측정을 위한 기초연구)

  • 민병혁;황덕용;정시영;구기갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.152-158
    • /
    • 2003
  • Titration method is one of the widely used methods for the concentration measurement of absorbent ammonia/water. However, this method is inconvenient because the solution should be extracted for the measurement. Moreover, significant error can be introduced by the evaporation of ammonia during the sampling and measuring procedure. In this study a reliable in-line concentration measurement method was proposed. To prove the validity of the concept, a measuring apparatus was designed, built, and tested with water. It is found that the location of flow inlet and exit is important in the measurement accuracy. The flow inlet and exit located in the middle of the test cell showed the best result. By the error analysis, it is expected that the ammonia concentration can be measured within the error of $\pm$0.18% assuming the error of 0.1 K in temperature measurement and 0.1 g in weight measurement.

Complex Permittivity Measurement of Simulated Brain Tissue for the Evaluation of Specific Absorption Rate(SAR) (전자파 비흡수율(SAR) 측정용 인체 두뇌 모의 용액의 복소 비유전율 측정)

  • 김정호;김윤명
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.310-313
    • /
    • 2003
  • Complex permittivities of human head simulating liquids were measured by a sample holder of terminated slotted coaxial line with a movable probe at mobile communication frequencies. The validity of the liquid measurement system was checked by experiments with the reference liquids. Liquids of ingredients for human brain suggested in IEEE draft and those made by the authors were measured by this slotted line system.

  • PDF

The Experimental Study on Simultaneous Measurements of $O_2$ Concentration and Temperature of Flue Gas Using a Single Diode Laser (다이오드 레이저를 이용한 배기가스 $O_2$ 농도 및 온도 동시 측정에 관한 실험적 연구)

  • Kim, Se-Won;Shin, Myoung-Chul;Lee, Chang-Yeop;Youn, Sung-Woon;Kim, Young-Il
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.1
    • /
    • pp.12-21
    • /
    • 2012
  • Simultaneous measurements of oxygen concentration and temperature using diode laser in the combustion environment are successfully accomplished. A single DFB type diode laser of 760 nm line centre frequency is used and the scanned-wavelength direct absorption spectroscopy method and wavelength modulation spectroscopy method are applied to measure absorption signals below 793 K temperature region. The experimental results show that oxygen concentration are measured within 1% accuracy and temperature are measured within 5% accuracy. This new method of simultaneous measurements of concentration and temperature with a single diode laser shows a great promise.

A Study of the Effect of Flight Attendants' Transformational Leadership on Their Job Satisfaction and Loyalty (항공사 객실승무원의 변혁적 리더십이 직무만족 및 조직몰입과 조직충성도에 미치는 영향)

  • Park, In-Seop;Hong, Yeong-Sik;Park, Ji-Yeong
    • 한국항공운항학회:학술대회논문집
    • /
    • 2015.11a
    • /
    • pp.212-223
    • /
    • 2015
  • This paper tries to provide and apply implications to line operation based on the analysis results by using empirical research methods. This paper has focused on the relationship among transformational leadership, job satisfaction, job absorption and loyalty. Following previous researches, the variables and hypothesis were defined and quantitatively measured in my research in order to analyze the effect of flight attendants' transformational leadership on their job satisfaction and loyalty. The managerial implications could be suggested as follows. Job absorption should be increased to improve flight attendants' loyalty to organization by increasing job satisfaction. Flight attendants' job satisfaction is related to transformational leadership which could be classified into Charisma, inspirational motivation and intellectual stimulus. Therefore flight attendants could be motivated by airline's controlling their charisma, inspirational motivation and intellectual stimulus. Solutions below are suggested to increase job satisfaction, absorption and loyalty.

  • PDF

Temperature measurement of the spray flame using micro scale absorption bands and line strength (마이크로 스케일의 흡수선과 흡수강도를 이용한 분무화염의 온도측정)

  • Choi, G.M.
    • Journal of ILASS-Korea
    • /
    • v.7 no.2
    • /
    • pp.1-6
    • /
    • 2002
  • It is necessary to develope a high frequency diode laser sensor system based on the absorption spectroscopy for the measurement of temperature of the spray flame. DFB diode laser operating near $2.0{\mu}m$ was used to scan over selected $H_2O$ transitions near $1.9{\mu}m\;and\;2.2{\mu}m$, respectively. The measurement sensitivity at wide range of sweep frequency was evaluated using multi-pass cell containing $CO_2$ gas. This diode laser absorption sensor with high temporal resolution up to 10kHz was applied to measure the gas temperature in the spray flame region of liquid-gas 2-phase counter flow flame. The successful demonstration of time series temperature measurement in the spray flame gives us motivation of trying to establish non-intrusive temperature measurement method in the practical spray flame.

  • PDF

2 - 5 μm Spectroscopy of Red Point Sources in the Galactic Center

  • Jang, DaJeong;An, Deokkeun;Sellgren, Kris;Ramirez, Solange V.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.67.4-67.4
    • /
    • 2019
  • We present preliminary results of our long-term (2009-2017) observing campaign using the NASA IRTF at Mauna Kea, to obtain $2-5{\mu}m$ spectroscopy of ~200 red point sources in the line of sight to the Galactic center. Point sources in our sample were selected from the mid-infrared images of the Spitzer Space telescope, and include candidate massive young stellar objects, which have previously been identified from our Spitzer/IRS spectroscopy. We show high foreground extinction of these sources from deep $3.1{\mu}m$ H2O ice and aliphatic hydrocarbon absorption features, suggesting that they are likely located in the central 300 pc region of the Galactic center. While many sources reveal photospheric $2.3{\mu}m$ gas CO absorption, few of them clearly indicate $3.54{\mu}m$ CH3OH ice absorption, possibly indicating a large dust column density intrinsic to a massive young stellar object.

  • PDF